PDF User Manual

  1. Home
  2. Manuals
  3. Leuze IT 4715 Quick Start User Manual

Leuze IT 4715 Quick Start User Manual

Made by: Leuze
Type: Quick Start User Guide
Category: Scanner
Pages: 15
Size: 0.93 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Leuze 

electronic

IT 4715
Fix mounted 2D-code scanner

Quick start user’s guide

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

2

Content

CONTENT ...................................................................................................................................................................... 2

SCOPE OF DELIVERY ................................................................................................................................................ 3

IT 4715 

XX

-

X

-

XXX

........................................................................................................................................................ 3

INSTALLATION............................................................................................................................................................ 3

C

ONNECTING THE SCANNER

.......................................................................................................................................... 3

Connecting the cable to the IT 4715 ......................................................................................................................... 3
Reading techniques................................................................................................................................................... 4
Testing the scanner ................................................................................................................................................... 4

TECHNICAL DATA...................................................................................................................................................... 5

P

INNING OF THE CABLES

................................................................................................................................................ 5

TTL-RS 232-cable/ ext IT 4xxx   Art-No. 501 04442 ................................................................................................ 5
TTL-RS 232 cable/ PIN9 IT 4xxx   Art-No. 501 04586 ............................................................................................. 5
USB-cable IT 4xxx   Art-No. 50103404 .................................................................................................................... 5

R

EADING FIELDS

............................................................................................................................................................ 6

IT 4715 SR-1-xxx ...................................................................................................................................................... 6
IT 4715 SF-1-xxx ...................................................................................................................................................... 7

IT 4715 FACTORY SETTINGS (DEFAULT)............................................................................................................. 8

CONFIGURATION ....................................................................................................................................................... 8

IT 4715 

AT THE SERIAL 

PC-

INTERFACE

......................................................................................................................... 8

With powering over PIN 9 at TTL-RS232-cable/PIN9 IT 4xxx  Art-No. 501 04586................................................. 8
With powering over the power supply at the RS 232-cable / ext IT 4xxx   Art-No. 501 03413................................. 9
Configuration for Leuze standard protocol .............................................................................................................. 9
IT 4715 to MA 41 DP-k or MA 41 IS ...................................................................................................................... 10
IT 4715 for MA 21 .................................................................................................................................................. 11

IT 4715 

AT THE 

USB-

INTERFACE 

(

KEYBOARD

-

EMULATION

)....................................................................................... 12

IT 4715 

AT THE 

USB 

INTERFACE 

(COM-

PORT

-

EMULATION

) ...................................................................................... 13

T

RIGGERING

................................................................................................................................................................ 13

TYPE OVERVIEW ...................................................................................................................................................... 14

ACCESSORIES ............................................................................................................................................................ 14

C

ONNECTION TO 

L

EUZE MULTI

N

ET 

P

LUS

.................................................................................................................... 15

C

ONNECTION TO 

PROFIBUS ...................................................................................................................................... 15

C

ONNECTION TO 

I

NTERBUS

......................................................................................................................................... 15

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

3

Abbildung 1: Kabelanschluss IT 4715

Scope of delivery

 

IT 4715 xx-x-xxx

1.  Scanners IT 4715 xx-x-xxx

Type overview see page 14

Accessories see page 14

Installation

Connecting the scanner

The figure below shows the cable connection. In the following you will find described several steps
of the connection of the scanner to a cable.

Connecting the cable to the IT 4715

To mount the cable at the Scanner, please proceed in the following way:

1.  Plug in the RJ 41 connector in the socket, until the cable is clicked in

2.  Connect the other side of the cable to your PC

3.  If you use the RS 232-interface you have to check, if the scanner  is supported with power. Please

check it with the pinning on page 5, to find the right cable

4.  Connect the power supply to the socket (if your PC do not support the power)

5.  Check if the scanner is working, hit the trigger button and look for the red LED‘s as well as for the green

target line. Scan a code label. The scanner confirms with an acoustic signal, if the code is decoded.

Type

Trigger button,
inside

Female connector

Paper clip

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

4

Reading techniques

The imager has a view finder that projects a
bright green aiming beam that corresponds to the
imager’s horizontal field of view. The aiming
beam should be centred over the bar code, but it
can be positioned in any direction for a good
read.

The aiming beam is smaller when the imager is
closer to the code and larger when it is farther
from the code. Symbologies with smaller bars or
elements (mil size) should be read closer to the
unit. Symbologies with larger bars or elements
(mil size) should be read farther from the unit. To
read single or multiple symbols (on a page or on
an object), hold the imager at an appropriate
distance from the target, activate the trigger, and
center the aiming beam on the symbol. If the
code being scanned is highly reflective (e.g.,
laminated), it may be necessary to tilt the code
+5° to prevent unwanted reflection.

You will find the reading fields on page 5

Testing the scanner

This bar code is for testing the scanner,
the module size is 0.5 mm (20 mil)

Code 39 bar code sample

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

5

Technical Data

Please refer to the corresponding data sheet

Pinning of the cables

TTL-RS 232-cable/ ext IT 4xxx   Art-No. 501 04442

Pinning 9 pin-D-sub connector (female) at the cable 42203758-04

PIN-number

Signal

Description

1

Shield

Shield

2

TX

Transmit data (-5 to +5V)

3

RX

Receive data (-5 to +5V)

5

GND

Signal ground

7

CTS

Clear to send

8

RTS

Request to send

PIN at power connector

Signal

Description

1

VCC IN

4,5 - 12 Volt DC

2

GND

Ground

The suitable power supply for the IT 4xxx (100-240 V / 47-63 Hz) is the article number 501 03403.

TTL-RS 232 cable/ PIN9 IT 4xxx   Art-No. 501 04586

Pinning 9 pin-D-sub connector (female) at the cable 42203758-03  

PIN-number

Signal

Description

1

Shield

Shield

2

TX

Transmit data (-5 to +5V)

3

RX

Receive data (-5 to +5V)

5

GND

Signal ground

7

CTS

Clear to send

8

RTS

Request to send

9

VCC IN

4,5 - 12 Volt DC

USB-cable IT 4xxx   Art-No. 50103404

Pinning of the USB-connector at the cable 42203758-03  

USB-type A-connector

Signal

Description

1

VCC IN

5 Volt DC

2

Data -

Data -

3

 Data +

 Data +

4

GND

Signal ground

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

6

Reading fields

IT 4715 SR-1-xxx

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

7

IT 4715 SF-1-xxx

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

8

IT 4715 factory settings (default)

To set the IT 4715 back to factory default, you have to scan this bar code.

Warning: All previous settings will be reset!!!!

(115200 baud, 8 data bits, 1 stop bit, no parity)

Configuration

The IT 4715 can be configured in two different ways.
One possibility is to read bar codes. You have to select the corresponding bar code and hit the trigger-
button to read the code. The configuration will be done immediately and stored in the device.
The most important configurations will be shown in the following.

The second possibility is to configure the IT 4715 with the PC-program VisualMenu over the RS 232 or USB
interface. You can download this program from our homepage 

www.leuze.de

. With this program you can

configure the IT 4715 via the PC and transmit the configuration to the device. The configuration can also be
stored in a file on the PC.
For more informations, please see the user’s guide IT 4600/4800.

In the following the most important configurations will be shown.

IT 4715 at the serial PC-interface

With powering over PIN 9 at TTL-RS232-cable/PIN9 IT 4xxx
Art-No. 501 04586

You have to connect the IT 4715 as shown
in the fig. on the right.

Necessary parts:
1x

IT 4715 XX-1-232

1x 

501 04586

cable TTL-RS 232/ PIN 9

Pinning 9 pin-D-sub connector (female) at the cable 42203758-03  

PIN-number

Signal

Description

1

Shield

Shield

2

TX

Transmit data (-5 to +5V)

3

RX

Receive data (-5 to +5V)

5

GND

Signal ground

7

CTS

Clear to send

8

RTS

Request to send

9

VCC IN

4,5 - 12 Volt DC

!

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

9

With powering over the power supply at the RS 232-cable / ext IT 4xxx
Art-No. 501 03413

You have to connect the IT 4715 as shown.

Necessary parts:
1x

IT 4715- XX-1-232

1x 

501 04 442 

TTL-cable RS 232 / ext

1x

501 03 403

power supply

Pinning 9 pin-D-sub connector (female) at the cable 42203758-04

PIN-number

Signal

Description

1

Shield

Shield

2

TX

Transmit data (-5 to +5V)

3

RX

Receive data (-5 to +5V)

5

GND

Signal ground

7

CTS

Clear to send

8

RTS

Request to send

PIN at power connector

Signal

Description

1

VCC IN

4,5 - 12 Volt DC

2

GND

Ground

The suitable power supply for the IT 4xxx (100-240 V / 47-63 Hz) is the Article-Number 501 03403.

RS 232 data transmission with 115200 Baud, 8 databit, 1 stopbit, no parity, postfixes CR/LF.

Configuration for Leuze standard protocol

Leuze standard protocol:
RS 232 with 9600 Baud, 8 databit, 1 stopbit, no parity, prefix STX and postfixes CR/LF

Leuze standard protocol

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

10

IT 4715 to MA 41 DP-k or MA 41 IS

RS 232 data transmission with 9600 baud, 8 databit, 1 stopbit, no parity, postfixes CR/LF.

Necessary parts:
1x

IT 4715 XX-1-232

1x 

501 04 442

TTL-cable RS 232 / ext

1x

501 03 403

power supply

1x

500 35 421

KB 021 Z

1x

500 33 638

MA 41 DP-k

for  PROFIBUS

(for Interbus: 500 28 994 MA 41 IS 

or  500 30 085 MA 41 IS PDP)

Pinning KB 021 Z

colour:

Signal

Pin MA 41:

Brown / braun

(RXD)

2

White / weiss

(TXD)

1

Blue / blau

(GND)

4

Red / rot

(VCC)

3

Black / schwarz

(GND)

Shield / blank

(PE)

21

You have to connect the IT 4715 as shown below.

Configuration

Connection for MA 41 in default

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

11

IT 4715 for MA 21

RS 232 data transmission with 9600 baud, 7 databit, 1 stopbit, parity even, postfixes CR/ LF.

Necessary parts:
1x

IT 4715 XX-1-232

1x 

501 04 586

TTL-cable RS 232/ ext

1x

500 35 421

KB 021 Z

1x

500 30 481

MA 21 100

Pinning KB021 Z

colour:

Signal

Pin MA 21:

Brown / braun

(RXD)

26

White / weiss

(TXD)

27

Blue / blau

(GND)

28

Red / rot

(VCC)

30

Black / schwarz

(GND)

31

Shield / blank 

(Schirm)

(PE)

21

You have to connect the IT 4715 as shown below.

Configuration

Connection for MA21 in default

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

12

 IT 4715 at the USB-interface (keyboard-emulation)

In this chapter the operation of the IT 4715 in keyboard-wedge mode at USB interface is described. The
data is transmitted to the open window at the position of the cursor. You can use this mode in all standard-
PC-programs.

Necessary parts:
1x

IT 4715 XX-1-USB

1x 

501 03 404 

cable USB

You have to connect the IT 4715 as shown below.

1.  Plug in the cable of the IT 4715 in

a free USB-port.

2.  The scanner gives you an

acoustic signal.

3.  Scan the code.

Configuration

USB-keyboard-emulation with CR LF

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

13

IT 4715 at the USB interface (COM-port-emulation)

In this chapter the operating emulation of a COM-port over the USB-interface is described. The scanned
data is sent to an new COM-port. You can download the required driver from our homepage 

www.leuze.de

.

Necessary parts:
1x

IT 4715 XX-1-USB

1x 

501 03 404 

cable USB

You have to connect the IT 4715 as shown
on the right.

1.  Plug in the cable of the IT 4715 in a

free USB port.

2.  The scanner gives you an acoustic

signal.

3.  Scan the code.
4.  Install the USB-serial driver, if

Windows asks for it.

5.  Open a terminal program, choose the new COM-port, and use baudrate 38400, 8 databits, 1 stopbit

and no parity. As postfix (or terminator)  CR.

Configuration

COM-port-emulation at the next free COM with 38400 baud,

8 databit, 1 stopbit, no parity and CR as postfix.

Triggering

To activate a read operation, you have to send a trigger command over the RS 232- or USB-interface (only
COM-port-emulation). The command has to be transmitted with the baudrate, parity, data- and stopbits
which you have configurated.
The command to activate is:       

SYN T CR

ASCII-Decimal-Values: 022; 084; 013

The command to deactivate is

SYN U CR

ASCII-Decimal-Values: 022; 085; 013

If you want stop the reading this what you have to send. After a good read it stops automatically.

The second possibility is to trigger with the integrated trigger-button. This button is int the inside and can
only be reached with an tool (example opened paper clip or similar).

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

14

Type overview

series IT

Art-Nr.

Description

Interface

Picture

Fix-scanner for bar codes and 2D-codes

50104049 IT 4715 SR-1-RS 232

TTL RS 232

50104051 IT 4715 SR-1-USB

USB

... (Special Focus – for small codes)

50104050 IT 4715 SF-1-RS 232

TTL RS 232

50104052 IT 4715 SF-1-USB

USB

All devices are without cable. Please order separately!

Accessories

Accessories for series IT

IT

 4

7

1

5

 X

X

-1

-2

3

2

0

3

1

C

IT

 4

7

1

5

 X

X

-1

-U

S

B

Art-Nr.

Description

P/N-Nr.

Picture

50103404

USB-cable for IT 4600/ 4800/ 4715 and
ST 2020

42206161-

01E

- X

50104442

TTL-RS 232-cable/ ext for IT 4715

42203758-

04E

X -

50104586

TTL-RS 232-cable/ PIN 9 IT 4715 and ST 2020

42203758-

03E

X -

50103403

Power supply for IT4600/ 4800/ IT 4715

for RS 232 cable

  

(5 Volt DC)

      

PS5U-4 +

77900508

X -

 


background image

Leuze 

electronic

Quickstart guide IT 4715

Leuze 

electronic

Page

15

Connection to Leuze multiNet Plus

 

MA 21 100

Interface converter/ multiNet slave

Art-Nr. 500 30 481

 

KB 021 Z

cable to MA 21 for IT4xxx

Art-Nr. 500 35 421

Connection to PROFIBUS

 

MA 41 DP-k  PROFIBUS gateway
Art-Nr. 500 33 638

 

KB 021 Z

cable to MA 41 for IT4xxx

Art-Nr. 500 35 421

Connection to Interbus

 

MA 41 IS

Interbus gateway

Art-Nr. 500 28 994

 

MA 41 IS PDP

Interbus gateway with "long data protocol"

Art-Nr. 500 30 085

 

KB 021 Z

cable to MA 41 for IT4xxx

Art-Nr. 500 35 421

Leuze 

electronic  

GmbH + Co. KG

P.O. box 1111
In der Braike 1
D-73277 Owen
Tel  +49 (07021) 573-0
Fax +49 (07021) 573199
E-mail: 

info@leuze.de

http://www.leuze.de

quickstart IT4715-v6.doc
11.2007