background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

1

 

 

 

 

 

 

 

I

I

N

N

S

S

T

T

A

A

L

L

L

L

A

A

T

T

I

I

O

O

N

N

,

,

 

 

O

O

P

P

E

E

R

R

A

A

T

T

I

I

O

O

N

N

 

 

A

A

N

N

D

D

 

 

M

M

A

A

I

I

N

N

T

T

E

E

N

N

A

A

N

N

C

C

E

E

 

 

M

M

A

A

N

N

U

U

A

A

L

L

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TO AIR HEAT RECOVERY UNIT WITH BUILT-IN 

INVERTER DRIVEN COMPRESSOR HEAT PUMP 

 
 
 
 
 
 
 

SERIES  

HPH-HPR-HPS

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

Dear Customer, 
 
Thank you for having purchased an LMF product. It is the result of many years of experience, research and has been 
made with top quality materials and highly advanced technologies. The CE mark guarantees that the machine meets the 
European Standards regarding safety. 
The  qualitative  level  is  kept  under  constant  surveillance.  LMF  products  therefore  offer  S
RELIABILITY. 
 
Thank you once again for your preference.
 

The manufacturer declines all responsibility for any i
The manufacturer reserves the right to modify the products contents in this catalogue without previous notice.

 
 
 
 
 
 

DECLARATION OF CONFORMITY

 
 
 
 
 
The Legal Representative of LMF S.p.A
the unit belonging to 

HPH, HPR 

and

 HPS

Voltage  Directive  2006/95/CE,  EMC  Directive  2004/108/CE
(Pressure Equipment Directive - Module A)
The unit belonging to the above series is designed according to the following main safety prescriptions:

 
- principals of safety integration; 
- used materials free from risk; 
- safety while transportation, handling and installation;
- protection against mechanical risks; 
- protection against electrical risks; 
- protection against fire risks; 
- design and construction done so that noise emission is reduced to mi
- protection against the risk to remain trapped inside the machine;
- CE indelible marking complete with the needed indications;
- supply of an “User manual” 

 
 
 
 
 
Meledo di Sarego (VI) 
10/12/2014 

 

 

Thank you for having purchased an LMF product. It is the result of many years of experience, research and has been 
made with top quality materials and highly advanced technologies. The CE mark guarantees that the machine meets the 

The  qualitative  level  is  kept  under  constant  surveillance.  LMF  products  therefore  offer  S

Thank you once again for your preference. 

The manufacturer declines all responsibility for any inaccuracies in this manual due to printing or typing errors. 
The manufacturer reserves the right to modify the products contents in this catalogue without previous notice.

DECLARATION OF CONFORMITY

 

The Legal Representative of LMF S.p.A., located in Meledo di Sarego, via Paradiso 33 (Vicenza

HPS

 series complies to the prescriptions of the Machine Directive 2006/42/CE, L

Voltage  Directive  2006/95/CE,  EMC  Directive  2004/108/CE,  Ecodesign  Directive  2009/125/CE

Module A). 

The unit belonging to the above series is designed according to the following main safety prescriptions:

safety while transportation, handling and installation; 

design and construction done so that noise emission is reduced to minimum level; 
protection against the risk to remain trapped inside the machine; 
CE indelible marking complete with the needed indications; 

The Legal Representative

 

 

Ferraro Mauro

2

 

Thank you for having purchased an LMF product. It is the result of many years of experience, research and has been 
made with top quality materials and highly advanced technologies. The CE mark guarantees that the machine meets the 

The  qualitative  level  is  kept  under  constant  surveillance.  LMF  products  therefore  offer  SAFETY,  QUALITY  and 

naccuracies in this manual due to printing or typing errors. 

The manufacturer reserves the right to modify the products contents in this catalogue without previous notice. 

 

., located in Meledo di Sarego, via Paradiso 33 (Vicenza- ITALY), declares that 

series complies to the prescriptions of the Machine Directive 2006/42/CE, Low 

Ecodesign  Directive  2009/125/CE  and  Directive  97/23/CE 

The unit belonging to the above series is designed according to the following main safety prescriptions: 

The Legal Representative 

 

Ferraro Mauro 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

3

 

 

 
SYMBOLOGY 
 

 

 
ATTENTION 
 

 

 
DANGER 
 

 

 
HIGH

 

RISK

 

OF

 

ELECTRIC

 

SHOCK 

 

 

 
ATTENTION:

 

AUTHORIZED

 

PERSONNEL

 

ONLY 

 

 
 
 
 
 

1

 

 

I

NTRODUCTION

 

 

 

 

 

 

pag. 4 

 

2

 

-

  

D

IMENSIONS AND 

W

EIGHTS

 

 

 

 

 

 

pag. 5 

 

3

 

 

T

RANSPORTATION

,

 

H

ANDLING AND 

S

TORAGE

 

 

 

 

 

 

pag. 8 

 

4

 

 

I

NSTALLATION 

&

 

C

ONNECTION

 

 

 

 

 

 

pag. 10 

 

5

 

 

W

IRING 

D

IAGRAMS

 

 

 

 

 

 

pag. 13 

6

 

 

E

LECTRONIC 

C

ONTROL

 

 

 

 

 

 

pag. 13 

 

7

 

 

S

CHEDULED 

M

AINTENANCE

 

 

 

 

 

 

pag. 13 

 

8

 

 

T

ROUBLESHOOTING

 

 

 

 

 

 

pag. 16 

 

9

 

 

M

ATERIAL 

D

ISPOSAL

 

 

 

 

 

 

pag. 16 

 
 

 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

4

 

1

 

-

 

I

NTRODUCTION

 

 
Dear Customer, 
 
this heat recovery unit with built-in heat pump is designed and developed for civil, commercial and industrial applications 
and both allows the room air renewal and supplies tempered air with a sure energy saving. Unit must be used only for 
this purpose, LMF will not respond in case of different use of the unit. 
 
 
In its basic working principle, it consists in : 
1 – fans (supply and exhaust air) 
2 – high efficiency heat recovery (crossflow for HPH, counterflow for HPS and thermal wheel type for HPR) 
3 – high efficiency inverter driven air-to-air reversible heat pump 
4 – filter sections (on fresh air and return air intakes) 
5 – electrical board complete with electronic control 
 
This unit may be integrated with traditional heating and cooling systems, but they can operate also autonomously.

 

 
• This manual together with separate wiring diagram and control instructions (supplied with the unit) must be kept in a dry 
place and ready to hand for future consultation when required. 
•  This  manual  has  been  compiled  to  ensure  that  the  unit  is  installed  in  the  correct  way  and  to  supply  comprehensive 
information  about  how  to  correctly  use  and  service  the  appliance. 

Before  proceeding  with  the  installation  phase, 

please  carefully  read  all  the  information  in  this  manual,  which  describes  the  procedures  required  to  correctly 
install and use the unit. 

• Strictly comply with the instructions in this manual and conform to the current safety standards. 
• The appliance must be installed in accordance with the laws in force in the country in which the unit is installed. 
• Unauthorized tampering with the electrical and mechanical equipment will 

VOID THE WARRANTY. 

•  Check  the  electrical  specifications  on  the  identification  plate  before  making  the  electrical  connections.  Read  the 
instructions in the specific section where the electrical connections are described. 
• If the unit must be repaired for any reason, this must only be done by a specialized assistance center recognized by the 
manufacturer and using genuine spare parts. 
• The manufacturer also declines all liability for any damage to persons or property deriving from failure of the information 
in this manual to correspond to the actual machine in your possession. 

• Proper uses: this series of air to air heat recovery unit is designed to air renewal/conditioning purposes. Any 
use  differing  from  this proper  use  or  beyond  the  operating  limits  indicated  in  this manual  is  forbidden  unless 
previously agreed with the manufacturer. 
• The prevention of the risk of fire/injury at the installation site is the 
responsibility of the end user and/or installer. 

 
 
 
Verify,  upon  acquisition,  that  the  apparatus  is  complete  and  supplied  as 
described. 
Any eventual disputes must be presented in writing within 8 days from the 
reception of the goods. 
 
 
Each unit is provided with identification plate listing the following: 

 
 

-

 

Address of Manufacturer 

-

 

“CE” Mark 

-

 

Model 

-

 

Serial Number 

-

 

Power supply (V - ph - Hz) 

-

 

Maximum current (A)

 

 

-

 

Manufacturing date 

-

 

Refrigerant type 

-

 

Compressor nominal power input (kW) 

-

 

Refrigerant quantity (kg) 

-

 

PED category 

-

 

Min/max refrigerant pressure (bar) 

-

 

Input power “kW” of electric heater (if present) 

-

 

Input current “A” of electric heater (if present) 

 
 
 

 

 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

5

 

2

 

 

D

IMENSIONS AND 

W

EIGHTS

 

 

Packing dimensions 

 
The following table, referred to the 

figure

, shows the characteristic dimensions of the series HPH and its accessories. 

 

 
 
 
 

S = Supply, E = Exhaust, R = Return F = Fresh air 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

S = Supply, E = Exhaust, R = Return F = Fresh air 

 

HPH 

 

14 

20 

26 

50 

92 

144 

205 

mm 

2185 

2185 

2515 

2845 

3175 

3505 

3835 

1030 

1195 

1360 

1690 

2020 

2350 

2350 

1190 

1190 

1190 

1520 

1850 

2180 

2510 

620 

785 

950 

1280 

1610 

1940 

1940 

475 

475 

475 

640 

805 

970 

1135 

L1 

150 

L2 

100 

L3 

635 

635 

635 

800 

965 

965 

965 

L4 

535 

W1 

620 

785 

950 

1280 

1610 

1940 

1940 

H1 

455 

455 

455 

620 

785 

950 

1115 

Weight 

kg 

550 

650 

800 

1000 

1200 

1550 

1850 

16

0

H

40

H

40

40

L

370

C

B

A

R

S

E

F

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

6

 

Packing dimensions 

 
The following table, referred to the 

figure

, shows the characteristic dimensions of the series HPR and its accessories. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

S = Supply, E = Exhaust, R = Return F = Fresh air 

 

HPR 

 

14 

20 

26 

50 

92 

144 

205 

mm 

2185 

2185 

2185 

2185 

2350 

2350 

2515 

1030 

1195 

1360 

1690 

2020 

2350 

2350 

1190 

1190 

1190 

1520 

1850 

2180 

2510 

620 

785 

950 

1280 

1610 

1940 

1940 

475 

475 

475 

640 

805 

970 

1135 

L1 

150 

L2 

100 

L3 

635 

635 

635 

800 

965 

965 

965 

L4 

535 

W1 

620 

785 

950 

1280 

1610 

1940 

1940 

H1 

455 

455 

455 

620 

785 

950 

1115 

Weight 

kg 

470 

560 

640 

890 

1120 

1360 

1630 

R

S

F

E

40

L

370

40

H

40

H

16

0

C

B

A

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

7

 

 

Packing dimensions 

 
The following table, referred to the 

figure

, shows the characteristic dimensions of the series HPS and its accessories. 

 

 
 
 
 

S = Supply, E = Exhaust, R = Return F = Fresh air 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

S = Supply, E = Exhaust, R = Return F = Fresh air 

 

HPS 

 

14 

20 

26 

50 

92 

144 

205 

mm 

2185 

2185 

2515 

2845 

3175 

3505 

3835 

1030 

1195 

1360 

1690 

2020 

2350 

2350 

1190 

1190 

1190 

1520 

1850 

2180 

2510 

620 

785 

950 

1280 

1610 

1940 

1940 

475 

475 

475 

640 

805 

970 

1135 

L1 

150 

L2 

100 

L3 

635 

635 

635 

800 

965 

965 

965 

L4 

535 

W1 

620 

785 

950 

1280 

1610 

1940 

1940 

H1 

455 

455 

455 

620 

785 

950 

1115 

Weight 

kg 

470 

560 

640 

890 

1120 

1360 

1630 

R

S

E

F

16

0

H

40

H

40

40

L

370

C

B

A

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

8

 

 
 

3

 

 

T

RANSPORTATION

,

 

H

ANDLING AND 

S

TORAGE

 

 

 

 

 

Packaging 

 
Each  unit  is  put  on  bench  and  protected  with  cellophane  film;  the  protection  must  remain  intact  until  the  moment  of 
installation. 
The materials that are not mounted for technical motives are supplied in fitted packing fixed externally or internally to the 
unit. 
Recycle and dispose of packing material in conformity with local regulations, be extremely careful not to damage the unit. 
 

 

 

Handling 

 
Comply with the current safety regulations concerning the equipment to use when handling the unit or the required ways 
of operating. Use single protection devices as goggles, gloves, helmets when handling the unit to avoid risk of injuries. 
 
For  the  lifting  and  transportation  of  the  unit,  use  adequate  equipment,  according  to  the  89/391/CEE  regulations  and 
further  modifications.  For  lifting,  use round  bars  crossing  the  baseframe  in  the prearranged  holes and  robust  ropes as 
shown on the below figure. 
Each individual unit weight is listed in this manual. 
While moving, try to avoid rotation without control. 
 

 

 
 

 

Check the weight of the unit before proceeding with the moving and handling operations. Make sure that the appliance is 
handled with care and without jolting as rough treatment could damage the functional parts 
of  the  machine.  To  safeguard  persons  and  property,  read  the  information  on  the  packing  that  covers  the  unit  before 
handling. 
Also make sure to: 
• Handle the machine with care 
• Do not stack other objects on top of the unit 
 
 
 
 
 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

9

 

Before positioning please consider the overall dimensions and the technical space requirements of the system and the 
unit, electric and hydraulic connections and any air pipes/ducts or free passages. 
Neglecting these aspects may decrease performance and operational life of the unit and therefore increase the operating 
costs and maintenance. 
Units are designed to be installed 

INSIDE

 or 

PARTIALLY OUTSIDE

 (roof cover needed) and in fixed positions. 

 
Before placing the unit be sure that: 
• the location is in a safe accessible place 
• the framework or the floor or ceiling is adequate to support the weight of the unit, please refer to weight paragraph 
• support points are leveled and aligned 
• the place can not be subject to flooding 
• the maximum level of the snow does not obstruct the airflow to the unit 
 
To ensure the best air circulation to the unit and thus ensure a smooth operation it is recommended to: 
• avoid obstructions to air flow near or above the unit 
• protect the unit from high winds that can favor or not the airflow 
• protect the unit from heat sources or pollutants (chimneys, extractors…) 
• protect the unit from air stratification or recirculation (avoid bad ducting of the fans, containment structure, high walls or 
corners next to the unit) 
These advises if not respected can lead to a lower efficiency of the unit and possible failures. 
 

Checklist 

 
Upon reception of the unit, we suggest that a complete control is carried out, to verify that the unit is intact and complete, 
and  no  damage  has  been  sustained  during  transport.  Any  eventual  damage  revealed  must  be  communicated  to  the 
carrier, demonstrating the reserve clause within the transport documents, specifying the type of damage. 
 

 
Storage 

 
The units must be stored in a dry place, sheltered from the sun, rain, sand and wind. 
Comply with the storage conditions given below: 
• Do not stack the units 
• Maximum temperature = 60°C 
• Minimum temperature = -20°C 
 

The Manufacturer declines any responsibility for any damage as a result of negligence or lack of protection from 
atmospheric agents. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

10

 

4

 

 

I

NSTALLATION 

&

 

C

ONNECTIONS

 

 
 

 

Definitions 

 

CUSTOMER

 – The Customer is the person, activity or the society, that has bought or hired the unit, and intends to utilize 

the machinery for its intended use.  
 

USER / OPERATOR

 – The User or Operator is the actual person that has been authorized by the Customer to utilize the 

unit. 
 

QUALIFIED PERSONNEL

 - Defined as the person who has followed a relevant specific course of study, and so is able 

to understand the dangers derived from the use of the machinery, and in turn, due to this, are capable of solving major 
dilemmas. 
 

 

Safety regulations 

 

 

 

Qualified personnel must carry out the installation. 

 

During  the  installation  operation,  use  protective  clothing,  for  example:  glasses,  gloves,  etc.  as  indicated  by 
686/89/CEE and successive regulations. 

 

During the installation operate in absolute security, pollution free air and in an area free of obstructions. 

 

Respect the regulations in force in the country in which the apparatus is being installed. Specifically relative to 
its use, and to the disposal of packing and products used for the cleaning and maintenance of the unit. Respect 
the recommendations given by the producers of such products. 

 

Before  placing  in  function  the  unit,  check  the  perfect  connection  of  the  various  components  and  the  internal 
parts of the system. 

 

Avoid at all costs human contact with moving parts and contact with the parts themselves.

 

 

Do not commence with servicing or cleaning of the unit, before the unit has been disconnected from the 
main supply. 

 

The maintenance and the substitution of damaged or consumed parts must be carried out only by specialized 
personnel, following the indications found within this manual. 

 

Spare parts must correspond to the requirements specified by Manufacturer. 

 

In case of dismantling of the unit

respect the anti-pollution regulations in force. 

 

N.B.

 The installer and the user of the apparatus must take into account, and solve problems, connected with any other 

type of risk that may occur to the unit. For example, risks derived from the entrance of foreign bodies, or risks due to the 
presence of flammable or toxic gas. 

 

 

The Manufacturer declines any responsibility for failure to respect the Safety Regulations and the prevention 
as described below. 
Furthermore,  the  Manufacturer  declines  any  responsibility  for  damage  caused  by  the  improper  use  of  the 
unit and/or modifications carried out without proper authorisation.

 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

11

 

 

Preliminary operations 

 

 

Check the perfect condition of the various components of the unit.

 

 

Control that contained within the packing, there are the installation accessories, and documentation. 

 

Transport the packed section as close as is possible to the intended place of installation. 

 

Do not place tools or weight on top of the packed unit. 

 

 

Choosing place of installation 

 

 

Position the unit on a solid structure, capable supporting the weight of the machine; on each support point install 
vibration damper device in order to reduce vibration transmission. 

 

Position  the  unit  in  a  point  where  the  condensation  discharge  may  occur  easily;  tilt  the  machine  towards  the 
water discharge connection (3° min) 

 

Do not position the unit in an area in which flammable gases, acidic or corrosive substances are present. They 
may damage various components in an irreparable manner. 

 

Allow a minimum amount of free space as indicated in the following 

figure

. This permits ease of installation and 

both scheduled and special maintenance (where B is the unit width). 

 
 
 

 

 

 

 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

12

 

Air duct connections 

 

 

 

 

The ducts must be correctly sized, in order to match unit external static pressure at duty airflow rate. 

 

To prevent the water condensation and cut down the sound level it is suggested to install insulated air ducts or 
provide a duct insulation. 

 

Between  unit  and  air  ducts  always  install  suitable  flexible  joints;  anyway,  the  electrical  continuity  must  be 
ensured between air ducts (if metal type) and unit by a ground cable. 

 

Water connections 

 
The installation and connecting of the piping is an operation that must be done correctly, otherwise it may compromise 
the performance of the system. At worst it may cause irreversible damage to the machine. These operations are to be 
effectuated by 

qualified personnel.

 

 

Condensation outlet connection 

 

Condensation outlet connections are on the opposite side to that of compressor and electric box. 

 

The system of drainage must provide, for each outlet,  an adequate trap able to allow the condensation run off 
on underpressure conditions. 

 

The trap must be designed as shown on the following 

figure

, where H shall be > 50 mm  

 

The trap must have a tap for correct cleaning of the lower part, and must allow an easy disassembly. 

 

The path of the condensation drainage tube must always have a gradient toward external. 

 

Insure that the condensation run-off tube does not interfere with discharge of the unit. 

 

 

Liv e llo  c ond en s a 

Co n d e ns a te  le v el  

 

 

Water coil connection (optional CCS section) 

 

The water heating or cooling coil (CCS) is supplied with GAS “male” threaded headers. 

 

The tightening must be carried out with extreme care to avoid damage to the copper collectors of the coil. 

 

The path of the tubes must be studied in a way to avoid obstacles should it be necessary to extract the unit coil. 

 

Inlet and outlet water must consent the thermal exchange against the current. Follow instructions found on the 
WATER INLET and WATER OUTLET plate. 

 

Provide an air valve at the top of the unit, and a water discharge valve at the bottom. 

 

Reinforce sufficiently the units external tubes to avoid offloading the weight onto the coil. 

 

Once connection has been effectuated, fix the external seal flush against the control panel, in this way avoiding 
the passing of air. 

 

The insulation must not rest against the paneling, as this may provoke burning. 

 

For  control  purposes,  organize  the  interception  of  the  tube  side  coil  when  the  fan  is  off,  to  avoid  internal 
overheating and possible damage to internal components. 

 

Provide an anti-freeze system. 

 

Provide a cut out switch to isolate the coil from the rest of the circuit in case of extensive maintenance needs. 

 

Should the unit be installed in particularly cold areas, drain completely before plant shut-off long periods. 
 

IMPORTANT: IT IS IMPORTANT NOT TO PLACE IN OPERATION THE UNIT IF THE FAN OUTLETS ARE NOT 
DUCTED OR NOT PROTECTED BY A SAFETY NET ACCORDING TO THE ACTUAL REGULATION. 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

13

 

 

Electrical connections 

 

Qualified personnel according to the supplied schemes must carry out the electrical connections at the control panel. 

 

 

Insure  that  the  voltage  and  the  frequency  shown  on  the  technical  plate  correspond  to  the  connecting  power 
supply. 

 

 

For  the  main  power  supply  of  the  unit  and  its  possible  accessories,  the  use  of  adapters,  multiple  plugs  and 
extension leads shall be avoided. 

 

It is the responsibility of the installer to insure that the installation of the unit is as close as possible to 
the main power supply, or sufficiently close to protect the electrical parts.  

 

Connect  the  unit  to  an  efficient  power  point,  by  using  the  glands  near  the  electric  box  panel;  power  supply 
terminals are screw type. 
 

 

5

 

 

W

IRING 

D

IAGRAMS

 

 

Follow wiring diagram attached to every unit inside the electrical board. 

Unit model

 

Series / Document code 

HPH & HPS 

HPR 

14-20-26 

AMF0007823 

AMF0007818-AMF0008055-AMF0008055 

50 

AMF0007473 

AMF0007819 

92 

AMF0007824 

AMF0007820 

144 

AMF0007825 

AMF0007821 

205 

AMF0007826 

AMF0007822 

 
 

6

 

 

E

LECTRONIC 

C

ONTROL

 

 

Follow instructions on HP user manual attached to every unit and contained inside the electrical board (document code 
MC00005, valid for all sizes). 
 
 

7

 

 

S

CHEDULED 

M

AINTENANCE

 

 

 

 

It is the responsibility of the User to carry out all types of maintenance operations. 

 

Only personnel previously trained and qualified may carry out maintenance operations. 

 

Should the unit require disassembly, hand and body protections are required 

 
Maintenance  keeps  unit  efficiency,  reduce  the  speed  of  deterioration  over  time  and  collect  information  and  data  to 
understand  the  efficiency  of  the  unit  and  prevent  failures.  We  suggest  to  prepare  a  booklet  of  installation  according 
European legislation. Provide a machine book that allows you to track of the actions taken on the unit, so it will be easier 
to cadence adequately the various interventions and will facilitate a possible troubleshooting. 
Please  take note  of:  date,  type  of action,  description of  action, measurements performed,  anomalies  identified,  alarms 
registered in the alarm history, etc.  

Before starting any operation, insure that the general power supply has been isolated. 
All the electrical connections must be protected at the source by the installer. 

Follow  the  connection  of  the  unit  and  its  accessories  using  adequate  cabling  for  the  power  used,  and 
respecting  the  country  regulations.  The  dimensions  of  the  cabling  must  be  sufficient  to  support  a  voltage 
drop in start up phase inferior to 3% of the nominal. 

BEFORE SERVICING THE UNIT, SWITCH OFF THE MAIN POWER SUPPLY. 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

14

 

 

Monthly maintenance 

 

Air filters 

 
Each filter section can be entered through hinged side panel, provided with handle; once entered, filter can be removed 
by side after removing the vertical filter frame by an Allen key (1).

 

This unit is equipped with soft bag filters; since they are not cleanable, check them monthly and replace them when dirty. 
For an automatic pressure drop limit control, installation of filter pressure switches is recommended. 
 

 

 

 
 
 
 
 

Yearly maintenance 

 
Check that all the electrical equipment, in particular the fixing of the electrical connections. 
Check the tightness of all nuts, bolts, flanges and hydraulic connections; tighten if loose. 
 

Heat recovery 

 
It generally requires no maintenance; just for checking cleaning of heat exchange surface and by-pass device for HPH 
and HPS units or wheel driver (motor, pulley and belt) for HPR units, unscrew the fixing panels on the opposite side of 
that of compressor. 
 
 
 
 
 
 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

15

 

 

Refrigerant circuit 

 
Check the whole circuit in order to find possible gas leakage. In case of leakage, previously empty the circuit and recover 
the refrigerant. Remove the lower panel with built-in handles, fixed by panel locks, to enter compressor compartment. 

 

 
 
 

Fans 

 
Each fan section can be entered through hinged side panel, provided with handle. Check that each impeller is clean and 
free to rotate.  

 

 
 
 
 

 


background image

 

MIUM0014_REV01_ HP_20151009-MIUM-ENG 

16

 

 

Water coil (optional CCS section) 

 
By unscrewing and removing the panel on the opposite side to that of water connection, check that the heat exchange 
surface is clean and fins are in perfect condition. 
 
 
 

8

 

 

T

ROUBLESHOOTING

 

 

 

Failure searching and problem solving schedule 

 

The following table is for possible failures of  air plant system; for errors and alarms displayed by the control panel, see 
control user manual. 

Founded failure

 

Probable cause 

Possible solution

 

Fans are not running 

 

Power supply is switched off

 

 

Wrong 

or 

loose 

electrical 

connections 

 

Motors on thermal protection mode 

 

Fan signal missing 

 

Switch on the power supply

 

 

Restore the right connections 

 

Check motor current 

 

Check signal connections 

Compressor is not running 

 

Thermal protection on 

 

Too high or too low freon pressure 

 

Check 

compressor 

working 

conditions 

Air performance decreasing 

 

Air filter dirty 

 

Air duct blocked 

 

Clean or replace filter

 

 

Check  air  system  (are  dampers 
open ?) 

Insufficient 

heating 

or 

cooling 

performance  

 

Temperature setpoint not correct 

 

Refrigerant filling not correct 

 

Refrigerant leakage 

 

Required  performance  not  met  by 
compressor capacity 

 

Unit on defrost mode 

 

Compressor 

cooling 

capacity 

reduced 

because 

of 

too 

high 

condensing pressure 

 

Adjust 

the 

right 

temperature 

setpoint,  compatibly  with  outdoor 
and 

indoor 

condition 

and 

compressor capacity limit 

 

Check possible leakage points 

 

Refill refrigerant 

Too high defrost cycle frequency  

 

Too cold outdoor air and/or indoor air 

 

Too low return airflow 

 

Preheat air 

 

Start  the  unit  after  room  is 
preheated 

 

Check 

return 

air 

filter 

and 

return/exhaust air circuit 

Condensate  water  stays  inside  the 
unit 

 

Condensate drainage blocked 

 

Missing or not adequate trap 

 

Clean or free the drainage 

 

Install a right trap 

 

 

 

9

 

 

M

ATERIAL 

D

ISPOSAL

 

 

At the end of unit’s lifetime, its components must be dismantled and disposed of respecting the operational regulations 
present in its country of installation. 
The materials that the unit is constructed of are: 
 

-

 

Precoated galvanized steel sheet metal 

-

 

Galvanized steel sheet metal 

-

 

Aluminum 

-

 

Copper 

-

 

Polyester 

-

 

Polyethylene 

-

 

Glass wool 

-

 

Plastic 

 
During disconnection of the unit, avoid gas leakage or liquid spillage on environment, especially if the water has additives 
like glycol. For dismissing and disposal, deliver the units to specialized centers according to your national laws.