background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

 

 

 

Wall Mount Booster LG 

Installation 

Instructions

  

 

FCC ID: NTAWMLG 

IC: 4732A-WMLG

  

 

 

14-Nov-11 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

CAUTION

 

The

 

User

 

and

 

the

 

Installer

 

should

 

be

 

aware

 

that

 

changes

 

and

 

modifications

 

to

 

the

 

equipment

 

not

 

expressly

 

approved

 

by

 

Master

 

Meter

 

could

 

void

 

warranty

 

and

 

the

 

user's

 

authority

 

to

 

operate

 

the

 

equipment.

  

Professionally

 

trained

 

personnel

 

should

 

install

 

the

 

equipment.

 

 

The

 

antenna

 

used

 

for

 

this

 

transmitter

 

must

 

be

 

installed

 

to

 

normally

 

provide

 

minimum

 

separation

 

distance

 

of

 

at

 

least

 

20

 

cm

 

from

 

all

 

persons

 

and

 

must

 

not

 

be

 

co

located

 

or

 

operating

 

in

 

conjunction

 

with

 

any

 

other

 

antenna

 

or

 

transmitter

 

 

ATTENTION

 

The

 

digital

 

portion

 

of

 

the

 

transceiver

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

part

 

15

 

of

 

the

 

FCC

 

Rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

 

This

 

equipment

 

generates

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

  

1.)

  

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

 

2.)

  

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

 

3.)

 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

 

4.)

 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

 

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

FCC

 

Rules

 

and

 

with

 

Industry

 

Canada

 

licence

exempt

 

RSS

 

standard(s).

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

This

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

This

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux 
appareils radio exempts de licence. L'exploitation est autorisée aux deux 
conditions suivantes :  
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil 
doit accepter tout brouillage radioélectrique subi, même si le brouillage est 
susceptible d'en compromettre le fonctionnement. 
 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

 

INTRODUCTION

 

 

The

 

2WM

LG

 

end

 

unit

 

for

 

water

 

meters

 

provides

 

two

way

 

communication

 

capabilities

 

over

 

the

 

Landis

 

&

 

Gyr

 

Gridstream

 

TM

 

RF

 

Network.

  

 

The

 

2WM

LG

 

is

 

battery

 

operated

 

unit

 

in

 

the

 

unlicensed

 

902

928MHz

 

band.

 

The

 

unit

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

rules

  

 

Following

 

are

 

the

 

main

 

features

 

of

 

the

 

2WM

LG

 

unit:

  

 



Periodically

 

transmission

 

of

 

the

 

water

 

meter

 

readings

 

(1

4

 

times

 

per

 

day)

  



On

 

request

 

reads

 

for

 

last

time

 

meter

 

reads

  



Alarm

 

report

 

&

 

data

 

logging

  



Remote,

 

over

the

air

 

firmware

 

upgrades

  



Remote

 

unit

 

configurations

  



Confirmation

 

of

 

network

 

connectivity

  

 

The

 

2WM

LG

 

may

 

be

 

connected

 

to

 

the

 

following

 

meters

 

(but

 

not

 

limited

 

to):

  

 



Segentia

 

TM

  



Invensys

 

TM

  



Hersey

 

5/8"

 

TM

  



ABB

 

TM

  



Neptune

 

ARB_V

 

TM

  



Neptune

 

ARB

 ‐

2

 

TM

  



Sensus

 

TM

  



Schlumberger

 

ARB_V

 

TM

  



3G

 

LCD

 

(Arad

 

technologies)

 

TM

  

 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

 

1

 ‐ 

Place

 

Setting

  

 

The

 

2WM

LG

 

unit

 

can

 

be

 

wall

 

mounted

 

in

 

an

 

external

 

open

 

site

 

or

 

within

 

buildings

 

 

 

Note:

 

 

The

 

2WM

LG

 

data

 

transmission

 

may

 

be

 

adversely

 

affected

 

if

 

it

 

is

 

installed

 

close

 

to

 

RF

 

or

 

EM

 

noise

 

generators,

 

for

 

example:

 

air

 

conditioner

 

units,

 

electric

 

generator,

 

radio

 

transmitter,

 

car

 

parking

 

and

 

others.

 

 

If

 

you

 

encounter

 

such

 

problems,

 

please

 

consult

 

Master

 

Meter

 

Service

 

representative

 

for

 

technical

 

assistance.

 

 
 
 
 
 

 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

 

 

2

 

 

Kit

 

Contents

 

 

Quantity

  

Name

  

1

 

1

 

1

 

2

 

2

 

1

 

2WM

LG

 

unit

 

Seal

 

Cover

 

Wall

 

Mount

 

Clip

 

Tapping

 

screw

  

Plastic

 

masonry

 

insert

  

ID

 

label

 

sticker

 

for

 

meter

 

identity

  

 

 

 

 

 

 

 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

 

 

2WM

LG

 

unit

 

 

Profile

 

#1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

3

 

 

Installation

 

Procedure

 

 

The

 

2WM

LG

 

is

 

intended

 

for

 

wall

 

installation

 

in

 

open

 

sites

 

and

 

buildings.

  

 

1.

 

Mark

 

the

 

locations

 

of

 

the

 

two

 

screws

 

on

 

the

 

wall,

 

according

 

to

 

the

 

holes

 

in

 

the

 

wall

 

mount

 

clip

 

of

 

the

 

unit.

  

 

 

 

 

 

2.

 

Drill

 

2

 

holes

 

and

 

insert

 

the

 

Plastic

 

masonry

 

inserts.

  

3.

 

Connect

 

the

 

wall

 

mount

 

clip

 

with

 

the

 

two

 

screw

 

supplied.

  

 

 

 

 

 

 

 

 

 

Mark

 

Location

Insert

 

screws

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

 

4.

 

Attached

 

the

 

2WMB

LG

 

unit

 

to

 

the

 

clip.

 

 
 
 
 
 
 
 
 
 

5.

 

Seal

 

the

 

cable

 

hole

 

with

 

the

 

supplied

 

seal

 

cover.

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

2WM

‐ 

LG

 

on

 

the

 

wall

Seal

 

Cover

 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

6.

 

Connect

 

the

 

wire

 

of

 

the

 

unit

 

according

 

to

 

the

 

connection

 

guide

 

on

 

the

 

water

 

unit,

 

pay

 

attention

 

to

 

connect

 

it

 

right.

  

 

 
 
 

 


background image

 
 

 
 
 
 
 
 

 
101 REGENCY PARKWAY
MANSFIELD, TX 76063 
817-842-8000 
FAX 817-842-8100 

 

 

 

4

 

 

Unit

 

Activation

 

 

1.

 

Face

 

the

 

Magnet

 

on

 

the

 

2WMB

LG

 

case.

 

2.

   

Remove

 

the

 

magnet

 

after

 

5

 

seconds.