background image

 
 

Installation instruction and user 

manual 

 

KT-2 

Spatial corrector 

 

 

 

The manual has to be handed over to the end user after installation. 

ID.: 17-16-13-2960-03 | 1.2017 

 

EN 

 
 

 

 

 


background image

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

2

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Installation instruction and user manual of the spatial corrector KT-2 
 
Id: 17-16-13-2960-03 | 7.2017 
 
Printed in Slovenia, copyright: Kronoterm d.o.o. 
 
This  document  is  copyrighted.  Any  use  outside  the  provisions  of  the  copyright  law  without  the 
permission of Kronoterm d.o.o. is illegal and punishable by law. All previous versions of this document 
are void. We reserve the right to make changes and printing errors. 
 

 

 

 


background image

 

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

Spatial Corrector KT-2 

The spatial corrector KT-2 is user friendly and allows measurements and displays of room temperature, 
adjustments of desired room temperature, the status of the heat circuit, settings of the circuit, status of 
alerts, external temperature and clock. 
 

Safety alerts 

 

 

 

DANGER 

Connecting the device to the power source can only be performed by a qualified installer in a 

voltage-free 

state! 

 

 

CAUTION 

The spatial corrector must be connected properly. An incorrect connection can damage the 
device.  The  manufacturer  is  not  responsible  for  damage  caused  by  incorrect  installation 
and/or improper use. 
 

Installation 

 
The Spatial corrector KT-2 must be installed in a room where the temperature is closest to your desired 
average temperature of other rooms (hallway, living room). 

The spatial corrector KT-2 is designed for installation on a flush-mounted electrical socket 3M 
(GW 24 403 PM). 

  The spatial corrector is used for fixed installation in closed and dry rooms. 

 

  Recommended mounting height is between 

1, 2 - 1, 5 m from the ground. 

  Do not expose the spatial corrector KT-2 to 

direct sunlight, do not install it in the area of 
air  currents  or  air  heated  in  any  other  way 
(e.g.  over  electric  cookers,  refrigerators, 
etc., or in the area of direct radiation heat of 
radiators),  because  the  heat  affects  the 
control characteristics. 

  Do  not  install  the  spatial  corrector  KT-2  as 

part  of  other  electrical  equipment,  e.g. 
dimmers,  a  possible  heat  emission  could 
affect proper operation. 

 

 

Installation 

Mount the spatial corrector KT-2 in: 

  A flush-mounted electrical socket 3M, H x W x D 106 x 74 x 48 mm 

 

Connect the spatial corrector KT-2 and the TERMOTRONIC controller with a 4-wire data cable. 
 
 
 

min. 

20 cm

 

1,2 - 1,5 m 

 


background image

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

4

 

 

Connection of Spatial Corrector 

 

 

  Connect a routed 4-wire cable to the terminals 

A+

B-

GND

 and 

+12 V 

of the spatial corrector KT-2. 

 

NOTE 

Connect  the  cables  you  have  connected  to  the 
spatial corrector KT-2 at terminals A+, B-, GND and 
+ 12V to the same terminals in the electrical closet 
controller TERMOTRONICTM. 

  In the case of a prefabricated cable, connect 1, 2 to 

A+

; 3, 4 to 

B-

; 5, 6 to 

+12 V

 and 7, 8 to the 

GND connection terminal on the spatial corrector KT-2. 

 

NOTE 

In the case of a direct connection of the spatial corrector KT-2 on the process module(PLC), 
connect the cables from the spatial corrector KT-2 connected to terminals 

A+

B-

GND

 and  

+12 V

 to the RJ-45 connector. Prepare the RJ-45 connector the same way as the one in the 

wiring diagram below. Connect it to the connecting terminal TS on the PLC in electric closet 
controller TERMOTRONIC. 
 

UTP link between RJ-45 connector and KT-2 

TIA / EIA 568A connection of connector 

Cable colors 

RJ-45

A+ B- GND+12V

KT-1

1 234 5 6 78

  

 

 

KT-2 

RJ-45 

A+

 


B-

 


12 V 


GND 


 

1

 

green 

and

 

white 

2

 

green 

3

 

orange

 

and 

white 
4

 

blue 

5

 

blue 

and

 

white 

6

 

orange 

7

 

brown

 

white 

8

 

brown 

 

5.1  Binding multiple spatial correctors 

 

Management of the spatial corrector 

Key 

Function keys 

 

RETURN: 

Return from the menu and cancel 

 

MENU: 

Scroll through menus and confirm

 

 

»

+

« – set the value, move up 

 

»

-

« – set the value, move down 

 

LED indicator of set value 

 

 


background image

 

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

Initial connection 

When  connecting  the  data  cable  to  the  control 
panel  fort  the  first  time,  the  regulating  circuit 
setup screen is displayed. 

 

 

SETUP OF CONTROL LOOP 

 

Set  the  desired  heating  circuit  with  the  keys 

 and 

. Press 

 to confirm the settings. 

The control panel confirms valid settings with 
a multi-tone beep. 

 

 

SYNCHRONISATION  

 

The  device  is  synchronising,  wait  a  few 

minutes

 … 

 

After  a  successful  synchronisation,  the  control 
panel is ready for use (see Qick user guide).  

 

 

NOTE 

Only one spatial corrector can control an individual control loop. Incorrect operation occurs if 
two spatial correctors are installed on the same control loop. 

 

10  CHNGE OR RESETTING OF CONTROL LOOP 

 

 

NOTE 

The  recommended  way  to  disconnect  the  power  supply  is  by  disconnecting  the  electrical 
fuse.

 

 
 
 
 
 
 
 
 

 


background image

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

6

 

 

 

  Disconnect the device power supply. 

 

  Reconnect the device power supply. 

  Accessing  the  menu  SETUP  OF 

CONTROL LOOP. 

The  menu  “Setup  of  control  loop”  can  be  accessed  only  during  the  first  minute  of  reconnecting  the 

control panel by holding the 

 and 

 keys for 8 seconds. 

11  MAIN SCREEN 

 
 

 

 

 

 
 

12  OPERATING STATUS 

13  SETTING TARGET ROOM 

TEMPERATURE 

 
 

 

 

Operation 

of 

control loop. 

Operational 
setting for

 

control loop. 

 

The  room  temperature  currently  set  is  displayed 
when  the 

or 

arrow  is  pressed.  The 

temperature is highlighted with an orange border. 

Fast  heating  of 
tap water /

 

Fail-safe 

anti-

freeze mode

 

is active. 

Device 
maintenance of 

 

required. 

Desired  room  temperature  can  be  set  by  pressing 
the  arrow  again,  the  setting  is  confirmed  by 
pressing  the  icon,  or  is  automatically  confirmed 
after 8 seconds. 

Child safety lock 
is active. 

Multiple alarms /

 

errors active. 

 

 

 

Circulation  pump 
of the control

 

loop  is  currently 
active. 

 

8

sek

Menu / 

confirm 

External 

temperature 

Menu down / 

decrease value 

Time 

Back / 

cancel 

Room 

temperature 

Menu up / 

increase value 

Operating 

status 

8

sec 

Room temperature 

movement trend   

 


background image

 

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

14  MENU 

 

NOTE 

Contents and display of menus depend on model and configuration of device. 

 

Operational setting for  
control loop. 

 

Setting night mode: 

 

Fast heating of  
tap water. 

 

The  display  automatically  dims  in  moderate 
light. 

 

Temperature setting 
for tap water. 

 

The display automatically dims in low light. 

 

Display brightness 
*Brightness is automatically  
adjusted depending on  
Surrounding light. 

 

The display automatically dims in darkness. 

 

Night mode. 

 

Disable night mode. The display is always on. 

 

 

 

 

15  CHILD SAFETY LOCK 

 

 

The function is activated by pressing and 
holding buttons 

 and 

 simultaneously for 

2  seconds.  The  icon 

 is  displayed  in  the 

status  bar  to  indicate  an  active  child  safety 
lock function. Key operation is disabled. 
 
The function is deactivated by pressing and 
holding  buttons 

 and 

f  or  2  seconds 

simultaneously.  The  function  icon  in  status 
bar  disappears  and  normal  button  operation 
is restored. 

 

Child safety lock function prevents unauthorized access to the module. The function can also be 
used to prevent unwanted button triggering while front panel cleaning.

 

 

16  QUICK MENU 

 

 

The  “Quick  menu”  can  be  accessed  by 
pressing  the 

 button.  By  pressing  the 

 

button, we navigate between System view and 
Weather  forecast  menus.  Weather  can  be 
viewed for the next two days. By pressing  
the 

 button, we return to the Main menu. 

 

OPOMBA 

The Weather is only shown if the device is connected to the Internet and the location of the 
device is set at the web interface Home Cloud. 

 
 
 
 
 
 
 
 

2

2

sec

 

 


background image

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

8

 

 

 

 

 
 

17  SYSTEM ERRORS 

 

S01  –  Data  connection  error  between  spatial  corrector 
and device. Check if the data cable is correctly connected 
to  the  connector  on  the  device.  After  the  cause  for  the 
error is resolved, the error is automatically confirmed. 
 
If another error is displayed, please consult our technical 
assistance. 

http://www.kronoterm.com/servis/

  

 

 

18  Technical Device Information 

 

  Dimensions HxWxD: 80x80x8,6 mm 
  The resolution of the temperature sensor 0,1 °C 
  Adjustable range 17 – 27 °C 
  Modbus RS485 connection  
  Max. 4 x KT-2 units can be connected to TT3000 

 

 

 

Weather 
symbol 

Highest (day-time)  
temperature forecast 

Air 
Humidity 

Day  
of the  
week 

Lowest  
(night-time)  
temperature forecas 

Device 

current 

operation symbol 

Water temperature  
in the buffer tank 

External air 
temperature 

Time 

Temperature  
of tap water 

 


background image

 

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

 

 

 

 


background image

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

10

 

 

 

 

 

 


background image

 

 

 

 

11 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

 

 

 

 


background image

 

The headquarters of the company and place of production 

 

Kronoterm d.o.o.  
Trnava 5e 
3303 Gomilsko 

 

Tel.: (00386) 3 703 16 20 | Fax: (00386) 3 703 16 33 | Web-page: 

www.kronoterm.com

 |  

E-mail: 

info@kronoterm.com

 | 

Customer support and service.: (00386) 3 703 16 26 | 

E-mail: 

servis@kronoterm.com