PDF User Manual

  1. Home
  2. Manuals
  3. Gooxi RMC2112-670-HSE User Manual

Gooxi RMC2112-670-HSE User Manual

RMC2112-670-HS

Made by: Gooxi
Type: User Manual
Category: Chassis
Pages: 18
Size: 0.83 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

RMC2112-670-HSE

User Manual

Version 1.0

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Content

Manual Structure

Foreword

Chapter 1 Chassis Overview

Chapter 2 Easy Installation Instruction

Chapter 3 Chassis Parameters

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Foreword

This manual is about the installation and use information of RMC2112-670-HSE

chassis that provided to professional system integrators and personal computer
technicians. The installation and maintenance should be conducted by experienced
technicians only.

Gooxi RMC2112-670-HSE the fourth generation of server chassis is designed

based on standard 2U server and can be assembled into common computing server,
storage server, Internet bar server, database server, VOD storage server, HPC server,
and so on. The server chassis is different from ordinary desktop chassis that pays
more attention to appearance design, as it focuses on the quality and content. Gooxi
RMC2112-670-HSE server chassis uses imported first-class SGCC galvanized steel,
and possessed with the characteristics of fingerprint resistance, corrosion resistance,
heat resistance, heat transfer and thermal reflectivity, formability as well as
weldability.

In addition, taking into account the higher stability requirements of the server

during usage, Gooxi RMC2112-670-HSE server chassis has excellent heat dispersion.
To be specific, the heat dissipation channel is reasonably designed, which can take
away a large amount of heat in the chassis to ensure the stable operation of the server.

The scalability is an important factor to determine whether the server chassis

design is reasonable. Gooxi RMC2112-670-HSE server chassis has stronger
scalability than ordinary chassis, such as: hard disk expander, peripheral expander,
etc.

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Chapter 1 Chassis Overview

1.1

Chassis Structure

1

Base

2

Rear window

3

Ventilation wall

4

Hard disk module

5

Top cover

6

Handle

7

Hard drive bracket

8

Fan

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

1.2 Rear Window Construction

Power site

I/O washer position

Expansion slot

1.3 Materials Package

48 pieces of #6-32*5mm countersunk screws are used for fixing hard disks.

10 pieces of active studs with the total height of 8mm are used to install the

motherboard.

16 pieces of #6-32*6mm cross recessed pan head screws are used for fastening

the motherboard and power supply.

0~11

SAS - label.

One 100 * 120 * 0.045mm PE valve bag.

1.4 Chassis View

Front view:

Rear view:

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

1.5 Related Indicators of Chassis Panel

The above picture shows the front panel buttons and LED indicators; each button

or indicator light has its own function and status description that are described in the

following table:

LED Status Description

No.

Picture

LED Appearance

Description

1

-

LOGO label (labeling or

customized acrylic label)

The green light is on

The device is on

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Reset

The button is used to restart

the server

The green light

flashes

The system is running

normally

The yellow light is

on

Alarm

indication,

including system alarm, fan

alarm, power alarm, etc.; the

specific can be viewed

through IPMI management

software

The green light is on

Internet access 1 connection

is normal

The green light is on

Internet access 2 connection

is normal

USB interface

2*USB2.0 interface

1.6 Introduction to Hard Disk Indicator

1

Act LED

2

FaultLED

3

StatusLED

4

LED description is as follows

Function

Act LED

Fault LED

Status LED

Hard disk at

site

ON

OFF

OFF

Hard disk

activity

Flash 4Hz/s

OFF

OFF

Hard disk

location

ON

Flash 4Hz/s

OFF

ActLED

Fault LED
StatusLED

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Hard disk

fault

ON

OFF

ON

RAID

reconstruction

ON

OFF

Flash 1Hz/s

1.7 Brief Introduction to Backplane

The standard configuration of Gooxi backplane model is RMC2112-BPE-12G,

and the specific description is as follows:

RMC2112-BPE-12G

Correspondin

g site

Interface / jumper /

slot

Correspondin

g site

Interface / jumper / slot

1、2、3

3 ATX power input

11

PMC PM8043 Expander chip

4、5、6、7

4 Sockets of 4PIN

temperature control fans

8

9

10

SFF-8643 12Gb SAS input

interface

1.8 Introduction to the Output Interface of Backplane Hard Disk

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Chapter 2 Easy Installation Instruction

2.1 Introduction to the Disassemble Steps of Gooxi 2112 Chassis Cover

Unscrew the top cover screws

Press the button of chassis back cover

Push the back cover

(4) Pull the back cover

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

2.2 Introduction to the Insert and Plug Steps of Gooxi2112 Chassis Hard Disk

Press the button to pull out the hard disk from the hard disk site.

(2) Install the 3.5-inch hard drive to the hard drive bracket according to screw holes,

as shown in the figure below.

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

(3) The installed hard disk is shown in the following figure:

(4) Insert hard disk to the chassis, and close the switch. As shown in the following

figure.

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

2.3 Introduction to the Installation Steps of Gooxi2108 Chassis Power Supply

(1)

Place the power supply case to the chassis according to the hole site, as shown in

the figure below

(2) Install the power to the chassis according to the correct position, and then screw

on the power supply screws at the position marked below.

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

(3) Fix the power supply bracket, and screw on the screws at the position marked in

the figure below.

(4) Insert the hot-swappable power modules PSU1 and PSU2, respectively

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

(5) The final installation effect of power supply.

2.4 Introduction to the Installation Steps of Motherboard on Gooxi 2112 Chassis

(1) Open the chassis, and place insulation pad according to the correct orientation.

Based on the hole of motherboard screw, motherboard active stud (8mm height) is

installed at the corresponding position on the insulation pad. As shown in the figure

below: Install Gooxi G1DE-4B dual circuit motherboard corresponding to the base

hole site.

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

(2) After the motherboard active stud (8mm height) is installed, place the motherboard

into the chassis and fasten motherboard screw at the hole site. As shown in the figure

below:

2.5 Introduction to the Installation Steps of Rear-built Hard Disk on Gooxi 2112

Chassis

(1) Install 2.5-inch Hot Swappable Hard Disk Module, as shown in the below

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

(2)

Install two 2.5-inch hard drives on the hard disk box, respectively.

(3) Insert two 2.5-inch hard drives into the rear hard disk module, respectively.

(4) Completed installation effect is shown as follows

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Note:

If customer selects two optional 2.5-inch hot-swappable hard drives,

then Gooxi-type CRPS power must be equipped with.

Chapter 3 Chassis Parameters

Basic Parameters

Chassis style

Rack mount

Chassis structure

2U

Applicable motherboard

EEB(12*13)/CEB(12*10.5)/ATX(12*9.5)/Micro ATX

Supported motherboard
brands

Gooxi、Intel、ASUS、SuperMicro、TYAN、MSI、GIGABYTE, etc.

Power type

Single charge and 1+1 redundant power

Number of supported
power supplies

1

SGPIO

Support

Backplane

12Gb/s SAS data backplane

Supported
hot-swappable hard
drives

Supportive, compatible with SAS and SATA drives

 


background image

Shenzhen Gooxi Hengyu Technology Co., Ltd

Supported
hot-swappable hard fans

Support

Hard driver site

12 3.5-inch (or 2.5-inch) hot-swappable hard disk sites; two optional 3.5
inch or 2.5-inch non-hot-swappable expandable sites

Hard disk shockproof
system

Hard disk bracket is designed with EMI shrapnel. The unique
shockproof fan design can reduce the resonance between the fan and
hard disk without affecting the I/O speed of hard disks.

Cooling system

Three 8038 fans are the standard configuration

Windshield

Optional configuration

Intelligent control of
temperature

Support

Expanded card site

7 half-height PCI or PCI-E expansion card sites, and 3 optional
transversal full-height expansion card sites

Supported rails

Optional

Apparent Parameters

Front panel interface

2 USB, 1 on-off key, 1 restart key, 1 hard disk indicator, 1 system failure
light, 2 network indicators

Free screws dismantle

Support

Fixed mode of cabinet

Ordinary

Configuration parameters

Product material

Imported SGCC (galvanized steel sheet), ABS panel and punching net

Chassis dimension

670*444*87.6mm(Depth * width * height)

Chassis weight

10.5kg

Package dimension

902*591*228mm(Length * width * height

Overall gross weight

16KG

Safety certification

CE

FCC

RoHS

Note: This manual is a general instruction of

RMC2112-670-HSE

series. Specific parameters of each

type please refer to the chassis detailed parameters.