PDF User Manual

  1. Home
  2. Manuals
  3. German Light Products Max 250 ELC Instruction Manual

German Light Products Max 250 ELC Instruction Manual

Made by: German Light Products
Type: Instruction Manual
Category: Flood Light
Pages: 15
Size: 0.23 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

250 ELC 

Instruction Manual

 

 

 

 

 

 

From Version 1.1 

 

 

email: service@glp.de 

Internet: http://www.glp.de 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

 

 

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

Contents 

1

 

Introduction ............................................................................................................. 4

 

1.1

 

Safety rules ....................................................................................................... 5

 

2

 

Installation ............................................................................................................... 6

 

2.1

 

Mounting ........................................................................................................... 6

 

2.2

 

Secure the Max ................................................................................................. 6

 

2.3

 

Connectors ....................................................................................................... 6

 

2.3.1

 

AC Connector ......................................................................................... 6

 

2.3.2

 

DMX ....................................................................................................... 6

 

2.4

 

Fuses ................................................................................................................ 6

 

3

 

Selecting Address/Basic Functions ...................................................................... 7

 

3.1

 

Adjust the DMX-Address .................................................................................. 7

 

3.2

 

Special Function ............................................................................................... 8

 

3.2.1

 

Sound function ....................................................................................... 8

 

3.2.2

 

Standalone Function .............................................................................. 8

 

3.2.3

 

Reset ...................................................................................................... 8

 

3.2.4

 

Switch off Lamp ...................................................................................... 8

 

4

 

Channel selection ( Overview table ) ..................................................................... 9

 

5

 

Change the Lamp .................................................................................................. 12

 

5.1

 

Safety rules ..................................................................................................... 12

 

5.2

 

How to change the lamp ................................................................................. 12

 

6

 

Maintenance the MAX ........................................................................................... 13

 

6.1

 

Optical System ................................................................................................ 13

 

6.2

 

Cleaning the Fans ........................................................................................... 13

 

7

 

Technical Data /Overview ..................................................................................... 14

 

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

Introduction 

Illustration 1-1 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

1.1  Safety rules 

The

 

 

M

M

a

a

x

x

 

  is  a  High-Tech  Product.  To  guarantee  a  smooth  operation,  it  is 

necessary to keep following rules. 

 

1. Make  sure  that  Head  and  Arm  of  the 

M

M

a

a

x

x,  can rotate without any mechanical 

problems and that all fan openings are clean and not blocked by anything. 

2. Touching the head while moving can cause serious injuries. 

3. Unplug the 

M

M

a

a

x

x

 

 from the AC outlet before any service. 

4. Wait at least 30 minutes after disconnecting the AC before you open the 

M

M

a

a

x

x

Please do not touch the Bulb unless you are absolutely sure it is cold. -Danger 

of BURNING-. 

5. For  safe  operation,  follow  the  Installation  guide  described  in  chapter  2. 

Operating the 

M

M

a

a

x

without Safety cables or clamps/hooks can increase the risk 

of an accident. 

6. The  installation  should  be  done  by  qualified  personal  only.  You  need  to  pay 

attention to the common rules of technology that are not explicitly mentioned in 

this manual. 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

Installation 

2.1  Mounting 

Mount clamps and/or hooks directly to the base plate. 

Please make sure to use right sized clamps and hooks and fit them securely. 

The 

M

M

a

a

x

x is fully operational whether it stands, hangs or is mounted to the wall. 

Using  the 

M

M

a

a

x

x  standing  on  the  ground  requires  a  rough  but even surface. Make 

sure that the fan openings are not blocked in any circumstance. 

2.2  Secure the Max 

Use always safety wires to secure the 

M

M

a

a

x

x, connect them with the base plate (see 

Drawing 1-1 Chapter 1) and check for tight fit! 

2.3  Connectors 

2.3.1  AC Connector 

230/120 Volt, 50/60 Hz 

Please see printing on the case for the right Power supply 

2.3.2  DMX 

DMX 512 Standard input/output  

Please see printing on the case for the right Pin usage. 

2.4  Fuses 

The 

M

M

a

a

x

x

 

 electronic system is protected by 5x20 T3.15A fuse 250V, or 5x20 6.3AT 

fuse  120V.  Please  see  the  printing  on  the 

M

M

a

a

x

x

 

  for  more  details  look  at  the 

Drawing 1-1 at Chapter 1. 

 

Disconnect AC outlet before changing a fuse !!!

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

Selecting 

Address/Basic Functions 

Adjust DMX-Address and basic functions before connecting the 

M

M

a

a

x

x to AC Power !!! 

 

3.1  Adjust the DMX-Address 

 

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

5

5

5

5

5

5

5

5

6

6

6

6

6

6

6

6

7

7

7

7

7

7

7

7

9

9

9

9

9

9

9

9

8

8

8

8

8

8

8

8

10

10

10

10

10

10

10

10

ON

ON

ON

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Address

max 1

max 2

max 3

max 4

max 5

max 6

max 7

max 8

 

 

DMX Address 

 

DMX Address 

 

DMX Address 

16 

 

DMX Address 

24 

 

DMX Address 

32 

 

DMX Address 

40 

 

DMX Address 

48 

 

DMX Address 

56 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

3.2  Special Function 

3.2.1  Sound function 

Sound controlled run of factory stored programs is possible by switching the 

DMX  Address  at  first 

M

M

a

a

x

x  as  seen  in  the  picture  below.  Set  the  Dip 

switches of any other connected 

M

M

a

a

x

x to OFF. 

1 2 3 4 5 6 7

9

8

10

ON

OFF

Address

 

3.2.2  Standalone Function 

Automatically  Runs  factory  stored  program.  If  you  want  to  use  this  setting 

while  connecting  more  than  one 

M

M

a

a

x

x  in  a  line,  set  the  Dip  switches  of  all 

others connected units to OFF. 

1 2 3 4 5 6 7

9

8

10

ON

OFF

Address

 

3.2.3  Reset 

All functions will Reset and move to zero position. 

1 2 3 4 5 6 7

9

8

10

ON

OFF

Address

 

3.2.4  Switch off Lamp 

If  the  channels  3  (Speed  Arm),  4  (Speed  Head)  and  8  (Shutter)  on 

M

M

a

a

x

x 

zero at the same time, the lamp of the 

M

M

a

a

x

x will switch off immediately. Any 

change of channel 8 (Shutter) will start the lamp again.  

If  there  is  no  signal  on  channel  8  (Shutter)  for  more  than  2  min.  on  DMX 

zero,  the  lamp  will  switch  off  automatically.  Any  signal  of  channel  8 

(Shutter) will start the lamp again.  

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

Channel selection ( Overview table ) 

Channel 

Description 

DMX-Value 

Hex- Value  Value in % 

1) Pan 

Armposition 

0 - 255 

0 - FF 

0 – 100 

2) Tilt 

Headposition 

0 - 255 

0 - FF 

0 – 100 

3) Speed 

    (Arm) 

Armspeed 1/8min-2/sec 

0 - 255 

0 - FF 

0 – 100 

4) Speed 

    (Head) 

Headspeed 1/8min-2/sec 

0 - 255 

0 - FF 

0 – 100 

5) Movements 

Head 

Arm 

 

 

 

 

Pos min 

Pos min 

0 - 15 

0 - F 

0 – 5 

 

Pos min 

Pos Max 

16 - 31 

10 - 1F 

6 – 12 

 

Pos Max 

Pos min 

32 - 47 

20 - 2F 

13 – 18 

 

Pos Max 

Pos Max 

48 - 63 

30 - 3F 

19 – 24 

 

Rotation left 

Pos min 

64 - 79 

40 - 4F 

25 – 31 

 

Rotation left 

Pos Max 

80 - 95 

50 - 5F 

32 – 37 

 

Rotation right 

Pos min 

96 - 111 

60 - 6F 

38 – 43 

 

Rotation right 

Pos Max 

112 - 127 

70 - 7F 

44 – 50 

 

Pos min 

Rotation left 

128 - 143 

80 - 8F 

51 – 56 

 

Pos Max 

Rotation left 

144 - 159 

90 - 9F 

57 – 62 

 

Pos min 

Rotation right 

160 - 175 

A0 - AF 

63 – 68 

 

Pos Max 

Rotation right 

176 - 191 

B0 - BF 

69 – 75 

 

Rotation left 

Rotation left 

192 - 207 

C0 - CF 

76 – 81 

 

Rotation right 

Rotation right 

208 - 215 

D0 - D7 

82 – 84 

 

Rotation left 

Rotation right 

216 - 231 

DA - E7 

85 – 90 

 

Rotation right 

Rotation left 

232 - 254 

E8 - FE 

91 – 99 

 

Reset all functions 

255 

FF 

100 

6) Color 

Color correction filter 5600K 

0 -3 

0 - 3 

 

Halfcolor 1 

4 - 7 

4 - 7 

 

blue 107 

8 - 11 

8 - B 

 

Halfcolor 2 

12 - 15 

C - F 

 

blue110 

16 - 19 

10 - 13 

 

Halfcolor 3 

20 - 23 

14 - 17 

 

blue101 

24 - 27 

18 - 1B 

10 

 

Halfcolor 4 

28 - 31 

1C - 1F 

11 

 

cyan 401 

32 - 35 

20 - 23 

13 

 

Halfcolor 5 

36 - 39 

24 - 27 

15 

 

green 201 

40 - 43 

28 - 2B 

16 

 

Halfcolor 6 

44 - 47 

2C - 2F 

18 

 

green 204 

48 - 51 

30 - 33 

19 

 

Halfcolor 7 

52 - 55 

34 - 37 

21 

 

yellow 601 

56 - 59 

38 - 3B 

22 

 

Halfcolor 8 

60 - 63 

3C - 3F 

24 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

10 

Channel 

Description 

DMX-Value 

Hex- Value  Value in % 

 

orange 306 

64 - 67 

40 - 43 

25 

 

Halfcolor 9 

68 - 71 

44 - 47 

27 

 

red 304 

72 - 75 

48 - 4B 

29 

 

Halfcolor 10 

76 - 79 

4C - 4F 

30 

 

pink 303 

80 - 83 

50 - 53 

32 

 

Halfcolor 11 

84 - 87 

54 - 57 

33 

 

magenta 501 

88 - 91 

58 - 5B 

35 

 

Halfcolor 12 

92 - 95 

5C - 5F 

36 

 

magenta 507 

96 - 99 

60 - 63 

38 

 

Halfcolor 13 

100 - 103 

64 - 67 

40 

 

cyan 104 

104 - 107 

68 - 6B 

41 

 

Halfcolor 14 

108 - 111 

6C - 6F 

43 

 

orange 302 

112 - 115 

70 - 73 

44 

 

Halfcolor 15 

116 - 119 

74 - 77 

46 

 

türkis 208 

120 - 123 

78 - 7B 

47 

 

Halfcolor 16 

124 - 127 

7C - 7F 

49 

 

pink 310 

128 - 131 

80 - 83 

50 

 

Halfcolor 17 

132 - 135 

84 - 87 

52 

 

yellow 603 

136 - 139 

88 - 8B 

54 

 

Halfcolor 18 

140 - 143 

8C - 8F 

55 

 

UV blue 108 

144 - 147 

90 - 93 

57 

 

Halfcolor 19 

148 - 151 

94 - 97 

58 

 

red 301 

152 - 155 

98 - 9B 

60 

 

Halfcolor 20 

156 - 159 

9C - 9F 

61 

 

open (no filter) 

160 - 175 

A0 - AF 

62 – 68 

 

Rotation 1 fast-slow 

176 - 208 

B0 - D0 

69 – 81 

 

Rotation stop 

209 - 221 

D1 - DF 

82 – 86 

 

Rotation 2 slow-fast 

222 - 255 

E0 - FF 

87 – 100 

7) Gobos 

Gobo 1 

0 - 7 

0 - 7 

 

Gobo 2 

8 15 

8 - F 

 

Gobo 3 

16 - 23 

10 - 17 

 

Gobo 4 

24 - 31 

18 - 1F 

11 

 

Gobo 5 

32 - 39 

20 - 27 

15 

 

Gobo 6 

40 - 47 

28 - 2F 

18 

 

Gobo 7 

48 - 55 

30 - 37 

21 

 

Gobo 8 

56 - 63 

38 - 3F 

24 

 

Gobo 9 

64 - 71 

40 - 47 

27 

 

Gobo 10 

72 - 79 

48 - 4F 

30 

 

Gobo 11 

80 - 87 

50 - 57 

33 

 

Gobo 12 

88 - 95 

58 - 5F 

36 

 

Gobo 13 

96 - 103 

60 - 67 

40 

 

Gobo 14 

104 - 111 

68 - 6F 

43 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

11 

Channel 

Description 

DMX-Value 

Hex- Value  Value in % 

 

Gobo 15 

112 - 119 

70 - 77 

46 

 

Gobo 16 

120 - 127 

78 - 7F 

49 

 

Gobo 17 

128 - 135 

80 - 87 

52 

 

Gobo 18 

136 - 143 

88 - 8F 

55 

 

Gobo 19 

144 - 151 

90 - 97 

58 

 

Gobo 20 

152 - 159 

98 - 9F 

61 

 

Gobo 21 

160 - 175 

A0 - A7 

68 

 

Rotation fast-slow 

176 - 208 

B0 - D0 

69 – 81 

 

Rotation stop 

209 - 255 

D1 - FF 

82 – 100 

8) Shutter 

Shutter closed 1 

0 - 7 

0 - 7 

 

Shutter open 

8 - 15 

8 - F 

 

Shutter closed 2 

16 - 23 

10 - 17 

 

Shutter frequency, high/low 

24 - 127 

18 - 7F 

9 – 50 

 

Shutter open, color/gobo speed slow - fast 

128 - 255 

80 - FF 

51 – 100 

Lamp off 

After 2 min. if: 

Shutter close or Shutter close 2 

0 – 7 

or 

16 – 23 

0 – 7 

or 

10 – 17 

0 – 2  

or 

5 – 8  

Lamp off 

Immediately if: 

Shutter close 1 and Speed Pan/Tilt = 0 

Shutter 

0 – 7 and 

Speed=0 

Shutter 

0 – 7 and 

Speed=0 

Shutter=2 

and 

Speed=0 

Lamp on 

If Shutter not closed 

Shutter

Shutter

Shutter

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

12 

Change the Lamp 

For  a  hassle  free  change  of  the  Light  bulb,  it  is  absolutely  necessary  to  follow  all 

descriptions in this chapter step by step. 

 

5.1  Safety rules 

Unplug AC power connection 

Allow to cool (over 30 minutes) 

Don’t touch lamp with bare fingers. 

Close the 

M

M

a

a

x

x before you connect the AC power! 

 

5.2  How to change the lamp 

Please look at Picture1-1 

 

1. Unscrew knurled knob on the Head Cover 

2. Remove Head Cover and put it aside 

3. Remove Lamp carefully from its holder and disconnect lamp socket 

4. Mount new lamp and close case using step 1-3 in reverse order 

 

Attention: Make sure that the lamp and the connectors fit in the right 

position and place !!! 

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

13 

Maintenance the MAX 

The  cleaning  of the inner optical System, color filters and color correction filter should 

be done by qualified person only! Contact your local GLP Dealer for details. 

 

ATTENTION:Use no strong detergents, acid etc. for cleaning the case !!! 

 

6.1  Optical System 

Clean the 

M

M

a

a

x

x

 

 optical system with a moistened cloth and a little cleaner. 

Remove the Lens holder to clean the lens  

 

ATTENTION: Let everything dry carefully before connect AC Power!  

 

6.2  Cleaning the Fans 

It  is  necessary  to  clean  the  fan  openings,  air  channels  and  fan  gratings  on  a 

regular basis (depending on the local environment). 

 

ATTENTION: If using the Max on the floor requires a continuously flow of air 

into the base fan opening !!! 

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

14 

Technical Data /Overview 

 

  Supply data 230/120 Volt 5x20 3.15AT/6.3AT 

  Lamp: 24V 250W ELC GX 5,3 

  DMX 512 Standard 

  Weight 13.5 kg 

  Dimensions: 240 x 335 x 430 mm 

  21 gobos 

  20 dichroitic colors 

  High speed Shutter 

  Stand alone  

  Music controlled 

  Base: 1U/12 min – 120U/min 

  Head: 1U/4min – 60U/min 

 

 

 


background image

 

 

 

GLP 

 

German Light Production 

(V2.1) 

15