Full Text Searchable PDF User Manual

250 ELC
Instruction Manual
From Version 1.1
email: service@glp.de
Internet: http://www.glp.de

GLP
German Light Production
(V2.1)
2

GLP
German Light Production
(V2.1)
3
Contents
1
Introduction ............................................................................................................. 4
1.1
Safety rules ....................................................................................................... 5
2
Installation ............................................................................................................... 6
2.1
Mounting ........................................................................................................... 6
2.2
Secure the Max ................................................................................................. 6
2.3
Connectors ....................................................................................................... 6
2.3.1
AC Connector ......................................................................................... 6
2.3.2
DMX ....................................................................................................... 6
2.4
Fuses ................................................................................................................ 6
3
Selecting Address/Basic Functions ...................................................................... 7
3.1
Adjust the DMX-Address .................................................................................. 7
3.2
Special Function ............................................................................................... 8
3.2.1
Sound function ....................................................................................... 8
3.2.2
Standalone Function .............................................................................. 8
3.2.3
Reset ...................................................................................................... 8
3.2.4
Switch off Lamp ...................................................................................... 8
4
Channel selection ( Overview table ) ..................................................................... 9
5
Change the Lamp .................................................................................................. 12
5.1
Safety rules ..................................................................................................... 12
5.2
How to change the lamp ................................................................................. 12
6
Maintenance the MAX ........................................................................................... 13
6.1
Optical System ................................................................................................ 13
6.2
Cleaning the Fans ........................................................................................... 13
7
Technical Data /Overview ..................................................................................... 14

GLP
German Light Production
(V2.1)
4
1
Introduction
Illustration 1-1

GLP
German Light Production
(V2.1)
5
1.1 Safety rules
The
M
M
a
a
x
x
is a High-Tech Product. To guarantee a smooth operation, it is
necessary to keep following rules.
1. Make sure that Head and Arm of the
M
M
a
a
x
x, can rotate without any mechanical
problems and that all fan openings are clean and not blocked by anything.
2. Touching the head while moving can cause serious injuries.
3. Unplug the
M
M
a
a
x
x
from the AC outlet before any service.
4. Wait at least 30 minutes after disconnecting the AC before you open the
M
M
a
a
x
x.
Please do not touch the Bulb unless you are absolutely sure it is cold. -Danger
of BURNING-.
5. For safe operation, follow the Installation guide described in chapter 2.
Operating the
M
M
a
a
x
x without Safety cables or clamps/hooks can increase the risk
of an accident.
6. The installation should be done by qualified personal only. You need to pay
attention to the common rules of technology that are not explicitly mentioned in
this manual.

GLP
German Light Production
(V2.1)
6
2
Installation
2.1 Mounting
Mount clamps and/or hooks directly to the base plate.
Please make sure to use right sized clamps and hooks and fit them securely.
The
M
M
a
a
x
x is fully operational whether it stands, hangs or is mounted to the wall.
Using the
M
M
a
a
x
x standing on the ground requires a rough but even surface. Make
sure that the fan openings are not blocked in any circumstance.
2.2 Secure the Max
Use always safety wires to secure the
M
M
a
a
x
x, connect them with the base plate (see
Drawing 1-1 Chapter 1) and check for tight fit!
2.3 Connectors
2.3.1 AC Connector
230/120 Volt, 50/60 Hz
Please see printing on the case for the right Power supply
2.3.2 DMX
DMX 512 Standard input/output
Please see printing on the case for the right Pin usage.
2.4 Fuses
The
M
M
a
a
x
x
electronic system is protected by 5x20 T3.15A fuse 250V, or 5x20 6.3AT
fuse 120V. Please see the printing on the
M
M
a
a
x
x
for more details look at the
Drawing 1-1 at Chapter 1.
Disconnect AC outlet before changing a fuse !!!

GLP
German Light Production
(V2.1)
7
3
Selecting
Address/Basic Functions
Adjust DMX-Address and basic functions before connecting the
M
M
a
a
x
x to AC Power !!!
3.1 Adjust the DMX-Address
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
9
9
9
9
9
9
9
9
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Address
max 1
max 2
max 3
max 4
max 5
max 6
max 7
max 8
DMX Address
0
DMX Address
8
DMX Address
16
DMX Address
24
DMX Address
32
DMX Address
40
DMX Address
48
DMX Address
56

GLP
German Light Production
(V2.1)
8
3.2 Special Function
3.2.1 Sound function
Sound controlled run of factory stored programs is possible by switching the
DMX Address at first
M
M
a
a
x
x as seen in the picture below. Set the Dip
switches of any other connected
M
M
a
a
x
x to OFF.
1 2 3 4 5 6 7
9
8
10
ON
OFF
Address
3.2.2 Standalone Function
Automatically Runs factory stored program. If you want to use this setting
while connecting more than one
M
M
a
a
x
x in a line, set the Dip switches of all
others connected units to OFF.
1 2 3 4 5 6 7
9
8
10
ON
OFF
Address
3.2.3 Reset
All functions will Reset and move to zero position.
1 2 3 4 5 6 7
9
8
10
ON
OFF
Address
3.2.4 Switch off Lamp
If the channels 3 (Speed Arm), 4 (Speed Head) and 8 (Shutter) on
M
M
a
a
x
x
zero at the same time, the lamp of the
M
M
a
a
x
x will switch off immediately. Any
change of channel 8 (Shutter) will start the lamp again.
If there is no signal on channel 8 (Shutter) for more than 2 min. on DMX
zero, the lamp will switch off automatically. Any signal of channel 8
(Shutter) will start the lamp again.

GLP
German Light Production
(V2.1)
9
4
Channel selection ( Overview table )
Channel
Description
DMX-Value
Hex- Value Value in %
1) Pan
Armposition
0 - 255
0 - FF
0 – 100
2) Tilt
Headposition
0 - 255
0 - FF
0 – 100
3) Speed
(Arm)
Armspeed 1/8min-2/sec
0 - 255
0 - FF
0 – 100
4) Speed
(Head)
Headspeed 1/8min-2/sec
0 - 255
0 - FF
0 – 100
5) Movements
Head
Arm
Pos min
Pos min
0 - 15
0 - F
0 – 5
Pos min
Pos Max
16 - 31
10 - 1F
6 – 12
Pos Max
Pos min
32 - 47
20 - 2F
13 – 18
Pos Max
Pos Max
48 - 63
30 - 3F
19 – 24
Rotation left
Pos min
64 - 79
40 - 4F
25 – 31
Rotation left
Pos Max
80 - 95
50 - 5F
32 – 37
Rotation right
Pos min
96 - 111
60 - 6F
38 – 43
Rotation right
Pos Max
112 - 127
70 - 7F
44 – 50
Pos min
Rotation left
128 - 143
80 - 8F
51 – 56
Pos Max
Rotation left
144 - 159
90 - 9F
57 – 62
Pos min
Rotation right
160 - 175
A0 - AF
63 – 68
Pos Max
Rotation right
176 - 191
B0 - BF
69 – 75
Rotation left
Rotation left
192 - 207
C0 - CF
76 – 81
Rotation right
Rotation right
208 - 215
D0 - D7
82 – 84
Rotation left
Rotation right
216 - 231
DA - E7
85 – 90
Rotation right
Rotation left
232 - 254
E8 - FE
91 – 99
Reset all functions
255
FF
100
6) Color
Color correction filter 5600K
0 -3
0 - 3
1
Halfcolor 1
4 - 7
4 - 7
2
blue 107
8 - 11
8 - B
3
Halfcolor 2
12 - 15
C - F
5
blue110
16 - 19
10 - 13
7
Halfcolor 3
20 - 23
14 - 17
8
blue101
24 - 27
18 - 1B
10
Halfcolor 4
28 - 31
1C - 1F
11
cyan 401
32 - 35
20 - 23
13
Halfcolor 5
36 - 39
24 - 27
15
green 201
40 - 43
28 - 2B
16
Halfcolor 6
44 - 47
2C - 2F
18
green 204
48 - 51
30 - 33
19
Halfcolor 7
52 - 55
34 - 37
21
yellow 601
56 - 59
38 - 3B
22
Halfcolor 8
60 - 63
3C - 3F
24

GLP
German Light Production
(V2.1)
10
Channel
Description
DMX-Value
Hex- Value Value in %
orange 306
64 - 67
40 - 43
25
Halfcolor 9
68 - 71
44 - 47
27
red 304
72 - 75
48 - 4B
29
Halfcolor 10
76 - 79
4C - 4F
30
pink 303
80 - 83
50 - 53
32
Halfcolor 11
84 - 87
54 - 57
33
magenta 501
88 - 91
58 - 5B
35
Halfcolor 12
92 - 95
5C - 5F
36
magenta 507
96 - 99
60 - 63
38
Halfcolor 13
100 - 103
64 - 67
40
cyan 104
104 - 107
68 - 6B
41
Halfcolor 14
108 - 111
6C - 6F
43
orange 302
112 - 115
70 - 73
44
Halfcolor 15
116 - 119
74 - 77
46
türkis 208
120 - 123
78 - 7B
47
Halfcolor 16
124 - 127
7C - 7F
49
pink 310
128 - 131
80 - 83
50
Halfcolor 17
132 - 135
84 - 87
52
yellow 603
136 - 139
88 - 8B
54
Halfcolor 18
140 - 143
8C - 8F
55
UV blue 108
144 - 147
90 - 93
57
Halfcolor 19
148 - 151
94 - 97
58
red 301
152 - 155
98 - 9B
60
Halfcolor 20
156 - 159
9C - 9F
61
open (no filter)
160 - 175
A0 - AF
62 – 68
Rotation 1 fast-slow
176 - 208
B0 - D0
69 – 81
Rotation stop
209 - 221
D1 - DF
82 – 86
Rotation 2 slow-fast
222 - 255
E0 - FF
87 – 100
7) Gobos
Gobo 1
0 - 7
0 - 7
2
Gobo 2
8 15
8 - F
5
Gobo 3
16 - 23
10 - 17
8
Gobo 4
24 - 31
18 - 1F
11
Gobo 5
32 - 39
20 - 27
15
Gobo 6
40 - 47
28 - 2F
18
Gobo 7
48 - 55
30 - 37
21
Gobo 8
56 - 63
38 - 3F
24
Gobo 9
64 - 71
40 - 47
27
Gobo 10
72 - 79
48 - 4F
30
Gobo 11
80 - 87
50 - 57
33
Gobo 12
88 - 95
58 - 5F
36
Gobo 13
96 - 103
60 - 67
40
Gobo 14
104 - 111
68 - 6F
43

GLP
German Light Production
(V2.1)
11
Channel
Description
DMX-Value
Hex- Value Value in %
Gobo 15
112 - 119
70 - 77
46
Gobo 16
120 - 127
78 - 7F
49
Gobo 17
128 - 135
80 - 87
52
Gobo 18
136 - 143
88 - 8F
55
Gobo 19
144 - 151
90 - 97
58
Gobo 20
152 - 159
98 - 9F
61
Gobo 21
160 - 175
A0 - A7
68
Rotation fast-slow
176 - 208
B0 - D0
69 – 81
Rotation stop
209 - 255
D1 - FF
82 – 100
8) Shutter
Shutter closed 1
0 - 7
0 - 7
2
Shutter open
8 - 15
8 - F
5
Shutter closed 2
16 - 23
10 - 17
8
Shutter frequency, high/low
24 - 127
18 - 7F
9 – 50
Shutter open, color/gobo speed slow - fast
128 - 255
80 - FF
51 – 100
Lamp off
After 2 min. if:
Shutter close or Shutter close 2
0 – 7
or
16 – 23
0 – 7
or
10 – 17
0 – 2
or
5 – 8
Lamp off
Immediately if:
Shutter close 1 and Speed Pan/Tilt = 0
Shutter
0 – 7 and
Speed=0
Shutter
0 – 7 and
Speed=0
Shutter=2
and
Speed=0
Lamp on
If Shutter not closed
Shutter
≠
0
Shutter
≠
0
Shutter
≠
0

GLP
German Light Production
(V2.1)
12
5
Change the Lamp
For a hassle free change of the Light bulb, it is absolutely necessary to follow all
descriptions in this chapter step by step.
5.1 Safety rules
Unplug AC power connection
Allow to cool (over 30 minutes)
Don’t touch lamp with bare fingers.
Close the
M
M
a
a
x
x before you connect the AC power!
5.2 How to change the lamp
Please look at Picture1-1
1. Unscrew knurled knob on the Head Cover
2. Remove Head Cover and put it aside
3. Remove Lamp carefully from its holder and disconnect lamp socket
4. Mount new lamp and close case using step 1-3 in reverse order
Attention: Make sure that the lamp and the connectors fit in the right
position and place !!!

GLP
German Light Production
(V2.1)
13
6
Maintenance the MAX
The cleaning of the inner optical System, color filters and color correction filter should
be done by qualified person only! Contact your local GLP Dealer for details.
ATTENTION:Use no strong detergents, acid etc. for cleaning the case !!!
6.1 Optical System
Clean the
M
M
a
a
x
x
optical system with a moistened cloth and a little cleaner.
Remove the Lens holder to clean the lens
ATTENTION: Let everything dry carefully before connect AC Power!
6.2 Cleaning the Fans
It is necessary to clean the fan openings, air channels and fan gratings on a
regular basis (depending on the local environment).
ATTENTION: If using the Max on the floor requires a continuously flow of air
into the base fan opening !!!

GLP
German Light Production
(V2.1)
14
7
Technical Data /Overview
♦
Supply data 230/120 Volt 5x20 3.15AT/6.3AT
♦
Lamp: 24V 250W ELC GX 5,3
♦
DMX 512 Standard
♦
Weight 13.5 kg
♦
Dimensions: 240 x 335 x 430 mm
♦
21 gobos
♦
20 dichroitic colors
♦
High speed Shutter
♦
Stand alone
♦
Music controlled
♦
Base: 1U/12 min – 120U/min
♦
Head: 1U/4min – 60U/min

GLP
German Light Production
(V2.1)
15