PDF User Manual

  1. Home
  2. Manuals
  3. German Light Product impression Wash One Instruction Manual

German Light Product impression Wash One Instruction Manual

Made by: German Light Product
Type: Instruction Manual
Category: Flood Light
Pages: 21
Size: 0.79 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

Instruction Manual 

 

from software version 1.02   
(Instruction version 1.01) 

 

e-mail: service@glp.de 

Internet: http://www.glp.de

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

2

 

Notes: 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

3

 

Table of contents 

1

 

Description of Device.............................................................................................. 4

 

1.1

 

Safety Instructions ............................................................................................ 5

 

2

 

Preparation and Installation ................................................................................... 6

 

2.1

 

Mounting ........................................................................................................... 6

 

2.1.1

 

Mounting on the floor (upright) ............................................................. 7

 

2.1.1

 

Mounting in hanging position (Head down) .......................................... 8

 

2.1.2

 

Mounting in sideways position ............................................................. 8

 

2.2

 

Securing the device .......................................................................................... 9

 

2.3

 

Connections ...................................................................................................... 9

 

2.3.1

 

Power Supply....................................................................................... 9

 

2.3.2

 

DMX ..................................................................................................... 9

 

3

 

The Menu Field ...................................................................................................... 10

 

4

4

 

Maintaining and Cleaning the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e ......................................... 18

 

4.1

 

Safety regulations ........................................................................................... 18

 

4.2

 

Maintenance Intervals (rule-of-thumb) ............................................................ 18

 

5

 

Technical Specifications ...................................................................................... 19

 

6

 

Index ....................................................................................................................... 20

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

4

 

1  Description of Device  

 

1.  Moving Head  

2.  Arm with various cooling vents 

3.  Tilt-lock to secure and lock the 

tilt movement  

4.  Backlight LCD graphical menu 

(data entry) 

5.  Base with various connectors 

and Camlock mounting 

system 

 

 

 

 

 

 

6.  DMX- Output (5 Pin)  

7.  DMX- Output (3 Pin) 

8.  Micro-fuse 6.3x32mm, T8A 

9.  Power Switch 

10. 2x Safety wire points 

11. Neutrik Powercon (Mains power 

input) 

12. Blank panel (primed for Ethernet) 

13. DMX- Input (3 Pin) 

14. DMX- Input (5 Pin) 

 

Note: Only connect one cable to the 

DMX Input / Output at the same time!  

Base Side 1

10

 

6

7

8

9

 

10

 

Base Side 2

11 12

13

 

14

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

5

 

1.1 

Safety Instructions  

 

 

The

 

 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e

 

 

is an advanced technology product. 

To  guarantee  smooth  operation,  it  is  necessary  to  follow  the 
following instructions. 

The  manufacturer  of  this  device  will  not  take  responsibility  of 
damages  through  any  disregard  of  the  information  in  this  user 
manual.  Warranty  claims  will  also  be  cancelled  in  the  event  of 
the system casing being opened. 

1.  Make  sure  that  before  powering  up  the  fixture,  the  fans  and  air  inlets  are 

clean and not blocked by anything. 

2.  Before  powering  up  the  fixture,  ensure  that  the  moving  head  part  of  the 

fixture can rotate unhindered through its full range of movement.  

3.  A  safety  distance  of  at  least  0.5  m  to  any  easily  flammable  material  (e.g. 

decoration material) must be adhered to.  

4.  Attention! Don’t touch the device during operation. Parts of the fixture can 

become hot and can cause injuries and / or damages.  

5.  Use only one DMX Input / Output at the same time.  

6.  Never look directly into the beam of light or one of the LEDs. Never use 

optical  apertures  with  a  distance  less  than  0.5  m  to  observe  the  beam  of 

light. LED Class 2M. Not following these precautions can result in serious 

injury to your eyes and in particular, your retina.    

 

Attention: LED Class 2M can cause injuries of your eyes even 
without optical instruments in front of them or within a distance 
of less than 0.5m and short exposure time.   

 

Avoid direct radiation to your eyes!   

7.  To  ensure  proper  operation,  you  must  also  follow  the  installation  guide 

described in chapter 2 of this manual. Operating the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e

 

 

without suitable mounting devices can increase the risk of an accident. 

8.  The 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e features a unique small and lightweight design 

with  no  specific  carrying  handles.  Care  needs  to  be  shown  when  handling 

the  fixture  to  ensure  that  no  unnecessary  damage  should  occur.  Fragile 

areas  include  the  LCD  display  and  cover  on  one  side  arm  and  the  front 

bezel.  Pressure  in  these  areas  could  result  in  damages  which  will  not  be 

covered by the standard warranty. 

9.  Repair,  maintenance  and  installation  work  should  only  be  performed  by 

qualified  or  GLP  certified  staff.  You  need  to  pay  attention  to  the  common 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

6

 

rules of technology that are not explicitly mentioned in this manual.  

10.  Use only original spare parts. Any structural modification on the system will 

terminate all warranty claims. 

11.  Please keep this instruction manual for future reference.  

 

2  Preparation and Installation 

2.1  Mounting  

The 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e is fully operational whether it hangs or is mounted 

to  a  wall.  It  can  also  be  operated  while  standing  on  the  floor.  Keep  a  safety 

distance of 0.5 m from any easily inflammable materials (decoration etc.).  

                     

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

7

 

 

 

 

Pay attention to the regulations of: BGV C1 (former VBG 70) 

and DIN VDE 0711-217. 

The installation shall be done by qualified personal only. 

For the various mounting positions of the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e (standing on 

the  floor,  sideways  or  hanging)  different  accessories  kits  are  available.  Using 

any required kits, along with the standard mounting connectors on the base of 

the fixture, will ensure a safe and firm installation.  

2.1.1  Mounting on the floor (upright) 

To operate the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e in an upright position, please use 

the  dedicated floor-stand  which  is  shipped  with  all  original  fixtures.  The 

floor  stand  is  mounted  to  the  base  of  the 

fixture  using  the  two  Camlock  quarter  turn 

fasteners.  Line  up  and  engage  the  camlock 

connectors from the floor stand into the base 

of the fixture and turn the two fasteners 90° 

to  lock  them.  Do  the  opposite  to  release 

them again. On both sides you'll find eyelets 

to  pull  though  a  ratchet  strap.  This  allows 

additional  bracing  of  the  floor-stand  during 

upright operation. 

M10

Gewinde

Camlock

Camlock

thread 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

8

 

 

 

 

 

 

 

 

 

 

 

 

2.1.1  Mounting in hanging position (Head down) 

To operate the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e in a hanging position, two omega 

brackets  can  be  mounted  directly  to  the  bottom  of  the  base  using  the 

four Camlock connectors.  

     

    

                          

2.1.2  Mounting in sideways position 

To  operate  the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e  in  a  sideways  position,  please 

use  an  additional  mounting  bar,  available  from  GLP  or  one  of  their 

agents.  This  mounting  bar  is  fixed  via  the  four  camlock  quick-release 

connectors.  Two half-couplers  or  clamps  are  then  used  to  hang  fixture. 

This  technique  is  necessary  to  cope  with  the  additional  torque  in  this 

mounting  position.  Never  use  the  "Mounting  in  hanging  position" 

technique described above to secure the fixture in a sideway position, as 

 

 

Camlock 

Eyelet 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

9

 

the fixtures base can become damaged, and a secure installation cannot 

be assured. 

 

 

 

 

 

 

 

            

2.2  Securing the device    

Regardless of the mounting method of the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e you'll have to 

use a secondary safety wire. This safety wire can be attached to the fixture by 

threading  it  through  one  of  the  two  holes  provided  on  the  base  of  the  fixture. 

Ensure  that  the  safety  wire  is  securely  fastened  through  the  fixture  and  the 

fixtures  mounting  support.  Install  a  safety  wire  that  can  hold  at  least  10  times 

the weight of the fixture.  

2.3  Connections 

2.3.1  Power Supply 

Autosensing  ~100-240  Volt  AC,  50-60  Hz,  earth  contact  type  plug  via 

Powercon  

Connected load 450 VA (W) 

<=>

 T8A (micro-fuse 6.3x32mm)  

Disconnect  from  the  mains  supply  before  changing  the  fuse  and 

use only the above described micro-fuse type.  

2.3.2  DMX 

USITT DMX-512 Standard input/output via 3 pin and 5 pin connectors.  

3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] 

5 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] / Pin 4/5 n.c. 

Ethernet (Artnet II compatible, ACN ready) 

Neutrik RJ-45 plug (for Neutrik EtherCon connector with body) 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

10

 

The Menu Field 

  

 

 

 

 

 

 

You’ll  find  the  control  board  on  the  side  of  the  arm.  It  allows  you  to  make  all  necessary 

adjustments  of  the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

W

W

a

a

s

s

h

h

 

 

O

O

n

n

e

e

.

.  With  the  Menu-key  you  get  into  the  main 

menu.  Afterwards  you  can  navigate  through  the  menu  with  the  Touchwheel.  Push  the 

Enter-key to get to the next menu level or to confirm your settings. Select ON/ OFF function 

settings with the Touchwheel. Confirm and save with the Enter-key. Push the Back-key to 

cancel the entry and go back to the main menu. 

 Back - Enter 

 

 

 

 

  

Layer 1 

Layer 2 

Layer 3 

Layer 4 

Notes 

DMX Start 
Address  

  

  

  

Set the DMX start address 

Personality  Pan/Tilt 

  

  

Pan/Tilt settings 

 

  

Pan invert 

  

Selects Inverse Pan, on or off 

 

  

Tilt invert 

  

Selects Inverse Tilt, on or off 

 

  

Feedback 

  

Automatic position feedback selection for 
pan/tilt movement  

 

Color 

Dimmer 
Curve 

 

Set the Dimmer Curve 

  

DMX 

Address 

  

Set the DMX start address 

 

  

Mode 

  

Allows selection of the desired DMX Mode 

 

 

  

Compressed  

Fixture works in "Compressed" mode 

 see 

also section 4 

 

 

  

Normal  

Fixture works in "Normal" mode 

 see also 

section 4 

 

 

  

High-
Resolution  

Fixture works in "High Resolution" mode 

 

see also section 4 

 

  

Hold Values    

Defines whether the last DMX signal is 
stored, or the lamp is switched OFF in case 
of signal interruption 

 

  

Manual 

  

Manual control of all system functions 

 

 

  

Pan 

Manual control  

 

 

  

Tilt 

Manual control  

 

 

  

Color 

Manual control  

Impression wash.one 

    

V1.02 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

11

 

 

 

  

Red 

Manual control  

 

 

 

Green 

Manual control  

 

 

 

Blue 

Manual control  

 

 

 

Shutter 

Manual control  

 

 

 

Dimmer 

Manual control  

 

 

 

Color temp. 

Manual control  

 

 

 

Special 

Manual control  

 

 

 

Movement 

Manual control  

 

 

 

Movement 
Speed 

Manual control  

 

 

 

Zoom 

Manual control  

 

 

 

Focus 

Manual control  

 

 

 

Beam 
Shaper  

Manual control  

 

 

 

Beam 
Shaper Size 

Manual control  

  

Display 

  

 

Adjustments for the Display 

 

  

Blackout 

 

Sets the display On or Off 

 

 

Auto-Rot 

  

Display will rotate automatically  

 

 

Display Inv 

  

Display will rotate manual 

 

 

Brightness 

  

Display backlight 

  

Set Default 

 

  

Resetting all functions to original values  
 

Status 

Version 

 

  

Shows the current software version 

  

Reset 
Hardware 

  

  

Hardware reset adjust 

 

  

All 

  

Reset all boards 

 

  

Head 

  

Reset only headboard 

 

 

FZE 

 

Reset only Focus Zoom 

 

  

Pan 

  

Reset only Pan 

 

  

Tilt 

  

Reset only Tilt 

  

Temperatures    

  

Display all temperatures 

  

LED Info 

  

  

Display the values for the LED´s 

 

  

Red 

  

Current value for red 

 

  

Green 

  

Current value for green 

 

  

Blue 

  

Current value for blue 

 

Error Status 

 

  

Shows the error status (N/A) 

 

Timer 

 

  

Shows the life time  

 

DMX Input 

  

Shows the current DMX signal per DMX 
channel  

 

  

Pan 

Instantaneous value for pan 

 

  

Tilt 

Instantaneous value for tilt 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

12

 

 

  

Color 

Instantaneous value for color 

 

  

Red 

Instantaneous value for red 

 

 

Green 

Instantaneous value for green 

 

 

Blue 

Instantaneous value for blue 

 

 

Shutter 

Instantaneous value for shutter 

 

 

Dimmer 

Instantaneous value for dimmer 

 

 

Colortemp. 

Instantaneous value for color temp. 

 

 

Special 

Instantaneous value for special 

 

 

Movement 

Instantaneous value for movement 

 

 

Movement 
Speed 

Instantaneous value for movement speed 

 

 

Zoom 

Instantaneous value for zoom 

 

 

Focus 

Instantaneous value for focus 

 

 

Beam 
Shaper 

Instantaneous value for shaper size 

 

 

Beam 
Shaper Size 

Instantaneous value for beam shaper 

 

DMX Quality 

 

Shows the DMX Quality 

Service 

Adjust 

 Enter Code    

Adjustments for all functions. Use code to 
enter calibration. (only for authorized 
persons with code) 

 

 

Pan 

 

Adjust for pan 

 

 

Tilt 

 

Adjust for tilt 

 

 

Beam Shape 
Arm  

 

Adjust for Beam Shaper arm 

 

 

Beam Shape 
Rot 

 

Adjust for Beam Shaper rotation 

 

 

Beam Shape 
Size 

 

Adjust for Beam Shaper size 

 

 

Super Beam 

 

Adjust for Super Beam 

 

 

Zoom 

 

Adjust for zoom 

 

 

Focus 

 

Adjust for focus 

 

 

Adjust 
Default set 

 

Set all adjustments to default 

 

 

Factory 
Adjust 

 

Factory internal adjustments 

 

Testmode 

 

  

Test mode(N/A) 

 

Diagnose 

 

  

Diagnose functions (N/A) 

 

Error Log 

 

  

Shows all errors in lifetime (N/A) 

 

 

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

13

 

DMX Channels 

Normal-Mode 18 DMX Channels 

 

 

 

 

Channel 

Function 

Time and Value 

DMX 

HEX 

1) PAN- coarse 

0 .. 540° 

  

0..255 

00..FF 

0..100 

2) PAN-fine 

High- Pos ... High- Pos + 
2,6° (16 Bit) 

  

0..255 

00..FF 

0..100 

3) Tilt- coarse 

0 .. 280°  

  

0..255 

00..FF 

0..100 

4) Tilt-fine 

High- Pos … High- Pos + 
1,2° (16 Bit) 

  

0..255 

00..FF 

0..100 

5) Color 

Colors adjustable via RGB 

  

0..7 

00..07 

0..2,5 

(fixed) 

Color 01 - Red  

  

8..15 

08..0F 

3..5,5 

  

Color 02 - Amber 

  

16..23 

10..17 

6..8,5 

  

Color 03 – Yellow warm  

  

24..31 

18..1F 

9..12,5 

  

Color 04 - Yellow  

  

32..39 

20..27 

13..15,5 

 

Color 05 – Green 

 

40..47 

28..2F 

16..18,5 

 

Color 06 – Turquoise 

 

48..55 

30..37 

19..21,5 

 

Color 07 – Cyan 

 

56..63 

38..3F 

22..24,5 

  

Color 08 - Blue  

  

64..71 

40..47 

25..27,5 

  

Color 09 - Lavender  

  

72..79 

48..4F 

28..30,5 

  

Color 10 - Malve 

   

80..87 

50..57 

31..34,5 

 

Color 11 – Magenta 

 

88..95 

58..5F 

35..37,5 

 

Color 12 - Pink 

 

96..103 

60..67 

38..40,5 

 

White - CTO 

Color temp.   
3200K 

104..111 

68..6F 

41..43,5 

 

White 

Color temp.   
5600K 

112..119 

70..77 

44..46,5 

 

White – CTB 

Color temp.   
7200K 

120..127 

78..7F 

47..49,5 

 

Rainbow Effect Stop 

 

128 

80 

50 

  

Rainbow Effect  

slow - fast 

129..223 

81..DF 

51..88 

6) Red 

Color mixing system - Red 

0 - 100% 

0..255 

00..FF 

0..100 

7) Green 

Color mixing system - 
Green 

0 - 100% 

0..255 

00..FF 

0..100 

8) Blue 

Color mixing system - Blue 

0 - 100% 

0..255 

00..FF 

0..100 

9) Shutter 

Shutter closed 

  

0..15 

00..0F 

0..5,5 

 

Shutter pulse random 

slow – fast 

16..47 

10..2F 

6..18,5 

 

Shutter ramp up 

slow – fast 

48..79 

30..4F 

19..31 

 

Shutter ramp down 

slow – fast 

80..111 

50..6F 

32..43 

 

Shutter ramp up/down 

slow – fast 

112..143 

70..8F 

44..56 

 

Random strobe 

slow – fast 

144..159 

90..9F 

57..62 

  

Strobe effect pause 

5s …0,1s 

160..199 

A0..C7 

63..77 

  

Strobe effect slow - fast 

1 Hz .. 25 Hz 

200..241 

C8..F1 

78..95 

  

Shutter open 

  

242..255 

F2..FF 

96..100 

10) Dimmer 

Dimmer  

0% - 100% 

0..255 

0..FF 

0..100 

11) Color temp. 

No color temperature 
correction 
 
 

 

0..7 

0..07 

0..2,5 

 

Continuous color 
temperature correction 
between 7200k - 3200k 

Applicable for ALL 
colors 

5)

 

8..255 

08..FF 

3..100 

12) Special 

RESET 1  

  

250..253 

FA..FC 

98..99 

  

RESET 2  
 

  

254..255 

FD..FF 

100 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

14

 

13) Movement 

No movement 

  

   

Movement 

Size 

Phase 

  

  

  

PAN 

0° 

  

01..01 

  

  

90° 

  

02..03 

  

  

180° 

  

04..05 

  

  

270° 

  

06..07 

  

PAN 

0° 

  

08..09 

  

  

90° 

  

10..11 

  

  

180° 

  

12..13 

  

  

270° 

  

14..15 

  

PAN 

0° 

  

16..17 

  

  

90° 

  

18..19 

  

  

180° 

  

20..21 

  

  

270° 

  

22..23 

  

PAN 

0° 

  

24..25 

  

  

90° 

  

26..27 

  

  

180° 

  

28..29 

  

  

270° 

  

30..31 

  

TILT 

size / phase see also 
PAN 

32..63 

20..3F 

13..25 

  

PAN / TILT 

size / phase see also 
PAN 

64..95 

40..5F 

26..37 

  

PAN / TILT (inverse) 

size / phase see also 
PAN 

96..127 

60..7F 

38..50 

  

Circle 

size / phase see also 
PAN 

128..159 

80..9F 

51..62 

  

Circle (inverse) 

size / phase see also 
PAN 

160..191 

A0..BF 

63..75 

  

Lying eight 

size / phase see also 
PAN 

192..223 

C0..DF 

76..87 

  

Random movement 

size see also PAN 

224..255 

E0..FF 

88..100 

14) Speed 

Pan/Tilt  relative movement 

  

0..1 

00..01 

0..0,5 

  Pan/Tilt 

Pan/Tilt  slow – fast 
Use this channel 14) also 
for the speed of the 
movements (channel 13). 

  
 

 

Pan Min. 540°  
Pan Max. 540° 
Tilt Min. 280°  
Tilt Max. 280° 

2..255 

02..FF 

1..100 

15) Zoom 

Super Beam   

3° 

0 .. 4 

00..04 

0..1 

 

Spot - Flood 

7° - 60° 

5 .. 255 

05..255  

2..100 

16) Focus 

Hard - Soft   

0 – 100% 

0 .. 255 

0..FF 

0..100 

17) Shaper Size 

Open - Close 

0 - 100% 

0..255 

00..FF 

0..100 

18) Beam Shaper  Rotate 

0° - 200° 

0..255 

00..FF 

00..100 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

15

 

Compress-Mode 14 DMX Channels 

Channel 

Function 

Time and Value 

DMX 

HEX 

1) PAN- coarse 

0 .. 540° 

  

0..255 

00..FF 

0..100 

2) PAN-fine 

High- Pos ... High- Pos +(16 
Bit) 

  

0..255 

00..FF 

0..100 

3) Tilt- coarse 

0 .. 280°  

  

0..255 

00..FF 

0..100 

4) Tilt-fine 

High- Pos … High- Pos + 
(16 Bit) 

  

0..255 

00..FF 

0..100 

5) Color 

Colors adjustable via RGB 

  

0..7 

00..07 

0..2,5 

(fixed) 

Color 01 - Red  

  

8..15 

08..0F 

3..5,5 

  

Color 02 - Amber 

  

16..23 

10..17 

6..8,5 

  

Color 03 – Yellow warm  

  

24..31 

18..1F 

9..12,5 

  

Color 04 - Yellow  

  

32..39 

20..27 

13..15,5 

  

Color 05 – Green 

 

40..47 

28..2F 

16..18,5 

  

Color 06 – Turquoise 

 

48..55 

30..37 

19..21,5 

  

Color 07 – Cyan 

 

56..63 

38..3F 

22..24,5 

 

Color 08 - Blue  

  

64..71 

40..47 

25..27,5 

 

Color 09 - Lavender  

  

72..79 

48..4F 

28..30,5 

 

Color 10 - Malve 

   

80..87 

50..57 

31..34,5 

 

Color 11 – Magenta 

 

88..95 

58..5F 

35..37,5 

 

Color 12 - Pink 

 

96..103 

60..67 

38..40,5 

 

White - CTO 

Color temp. 3200K 

104..111  68..6F 

41..43,5 

 

White 

Color temp. 5600K 

112..119 

70..77 

44..46,5 

 

White – CTB 

Color temp. 7200K 

120..127  78..7F 

47..49,5 

 

Rainbow Effect Stop 

 

128 

80 

50 

  

Rainbow Effect  

slow - fast 

129..223  81..DF 

51..88 

6) Red 

Color mixing system - Red 

0 - 100% 

0..255 

00..FF 

0..100 

7) Green 

Color mixing system -Green  0 - 100% 

0..255 

00..FF 

0..100 

8) Blue 

Color mixing system - Blue 

0 - 100% 

0..255 

00..FF 

0..100 

9) Shutter 

Shutter closed 

  

0..15 

00..0F 

0..5,5 

 

Shutter pulse random 

slow – fast 

16..47 

10..2F 

6..18,5 

 

Shutter ramp up 

slow – fast 

48..79 

30..4F 

19..31 

 

Shutter ramp down 

slow – fast 

80..111 

50..6F 

32..43 

 

Shutter ramp up/down 

slow – fast 

112..143  70..8F 

44..56 

 

Random strobe 

slow – fast 

144..159  90..9F 

57..62 

  

Strobe effect pause 

5s …0,1s 

160..199  A0..C7 

63..77 

  

Strobe effect slow - fast 

1 Hz .. 25 Hz 

200..241  C8..F1 

78..95 

 

Shutter open 

  

242..249  F2..F9  95,5..96,5 

 

RESET 1 

 Only Head 

250 

FA 

97 

 

RESET 2 

 All Funktions 

251 

FB 

98 

 

Shutter open  

  

252..255  FC..FF 

99..100 

10) Dimmer 

Dimmer  

0% - 100% 

0..255 

0..FF 

0..100 

11) Zoom 

Super Beam   

3° 

0 .. 4 

00..04 

0..1 

 

Spot - Flood 

7° - 60° 

5 .. 255 

05..255  

2..100 

12) Focus 

Hard - Soft   

0 – 100% 

0 .. 255 

0..FF 

0..100 

13) Shaper Size 
 

Open - Close 

0 - 100% 

0..255 

00..FF 

0..100 

14) Beam Shaper  Rotate 

0° - 200° 

0..255 

00..FF 

00..100 

 
 
 
 
 
 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

16

 

High Resolution (Extended)-Mode 24 DMX Channels 

Channel 

Function 

Time and Value 

DMX 

HEX 

1) PAN- coarse 

0 .. 540° 

  

0..255 

00..FF 

0..100 

2) PAN-fine 

High- Pos ... High- Pos + (16 
Bit) 

  

0..255 

00..FF 

0..100 

3) Tilt- coarse 

0 .. 280°  

  

0..255 

00..FF 

0..100 

4) Tilt-fine 

High- Pos … High- Pos + (16 
Bit) 

  

0..255 

00..FF 

0..100 

5) Color 

Colors adjustable via RGB 

  

0..7 

00..07 

0..2,5 

(fixed) 

Color 01 - Red  

  

8..15 

08..0F 

3..5,5 

  

Color 02 - Amber 

  

16..23 

10..17 

6..8,5 

  

Color 03 – Yellow warm  

  

24..31 

18..1F 

9..12,5 

  

Color 04 - Yellow  

  

32..39 

20..27  13..15,5 

  

Color 05 – Green 

 

40..47 

28..2F  16..18,5 

  

Color 06 – Turquoise 

 

48..55 

30..37  19..21,5 

  

Color 07 – Cyan 

 

56..63 

38..3F  22..24,5 

 

Color 08 - Blue  

  

64..71 

40..47  25..27,5 

 

Color 09 - Lavender  

  

72..79 

48..4F  28..30,5 

 

Color 10 - Malve 

   

80..87 

50..57  31..34,5 

 

Color 11 – Magenta 

 

88..95 

58..5F  35..37,5 

 

Color 12 - Pink 

 

96..103 

60..67  38..40,5 

 

White - CTO 

Color temp.  
3200K 

104..111  68..6F  41..43,5 

 

White 

Color temp.  
5600K 

112..119  70..77  44..46,5 

 

White – CTB 

Color temp. 
7200K 

120..127  78..7F  47..49,5 

 

Rainbow Effect Stop 

 

128 

80 

50 

 

Rainbow Effect  

slow - fast 

129..223  81..DF 

51..88 

6) Red- coarse 

Color mixing system – Red  

0 - 100% 

0..255 

00..FF 

0..100 

7) Red-fine 

Color mixing system – Red-
low 

  

0..255 

00..FF 

0..100 

8) Green- coarse 

Color mixing system – Green   0 - 100% 

0..255 

00..FF 

0..100 

9) Green- fine 

Color mixing system – 
Green-low 

  

0..255 

00..FF 

0..100 

10) Blue- coarse 

Color mixing system – Blue  

0 - 100% 

0..255 

00..FF 

0..100 

11) Blue-fine 

Color mixing system – Blue-
low 

  

0..255 

00..FF 

0..100 

12) Shutter 

Shutter closed 

  

0..15 

00..0F 

0..5,5 

 

Shutter pulse random 

slow – fast 

16..47 

10..2F 

6..18,5 

 

Shutter ramp up 

slow – fast 

48..79 

30..4F 

19..31 

 

Shutter ramp down 

slow – fast 

80..111 

50..6F 

32..43 

 

Shutter ramp up/down 

slow – fast 

112..143  70..8F 

44..56 

 

Random strobe 

slow – fast 

144..159  90..9F 

57..62 

  

Strobe effect pause 

5s …0,1s 

160..199  A0..C7 

63..77 

  

Strobe effect slow - fast 

1 Hz .. 25 Hz 

200..241  C8..F1 

78..95 

 

Shutter open 

  

242..255  F2..FF  96..100 

13) Dimmer- 
coarse 

Dimmer  

0% - 100% 

0..255 

0..FF 

0..100 

14) Dimmer- fine 

Dimmer low 

  

0..255 

0..FF 

0..100 

15) Color temp.  

No color temperature 
correction 

 

0..7 

0..07 

0..2,5 

 

Continuous color temperature 
correction between 7200k - 
3200k 

Applicable for ALL 
colors 

5)

 

8..255 

08..FF 

3..100 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

17

 

16) Special 

RESET 1  

  

250..253  FA..FC 

98..99 

  

RESET 2  

  

254..255  FD..FF 

100 

17) Zoom coarse 

Super Beam   

3° 

0 .. 4 

00..04 

0..1 

 

Spot - Flood 

7° - 60° 

5 .. 255  05..255  

2..100 

18) Zoom fine 

Zoom low 

(0% - 100%) 

0..255 

0..FF 

0..100 

19) Focus coarse 

Hard - Soft   

0% – 100% 

0 .. 255 

0..FF 

0..100 

20) Focus fine 

Focus low 

(0% - 100%) 

0..255 

0..FF 

0..100 

21) Shaper Size 
coarse 

Open - Close 

0 - 100% 

0..255 

00..FF 

0..100 

22) Shaper Size 
fine 

Shaper low 

(0% - 100%) 

0..255 

00..FF 

00..100 

23) Beam Shaper 
coarse 

Rotate 

0° - 200° 

0..255 

00..FF 

00..100 

24) Beam Shaper 
fine 

Iris low 

 (0% - 100%) 

0..127 

00..7F 

00..50 

 

Locking and unlocking the Control Panel 

The Display  will auto look automatically if the Touch Panel  will not use for 10s. To unlook the Touch 

Panel you have to press one of the menu buttons for 2s..  

 

1)

 Colors  

The predefined colors can be used as start colors for the Rainbow effect.  First select a desired start 

color, then activate the rainbow effect. All 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

O

O

n

n

e

e

 will then begin from that color 

and  execute  the  rainbow  effect  synchronously.  Different 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

O

O

n

n

e

e

  can  have 

different  start  colors  but  will  still  execute  the  rainbow  effect  synchronously.  If  you  choose  a  color 

different from the ones marked with 

1)

 in the tables above the rainbow start-color will be red. 

 

 

2)

 Rainbow-effect Stop  

will pause this function. After resuming the rainbow-effect will be continued with the current color.  

 

3)

 The Rainbow-effect  

will run synchronously only if it is started from one of the predefined colors (see also 

1)

 before). 

 

4)

 Attention:  

Please  note  that  shutter  frequencies  over  10  Hz  are  prohibited  in  some  countries.  Especially 

frequencies  in  the  range  of  5  -  12  Hz  can  possibly  cause  epileptic  seizures 

  continuous  blink 

irritation  with  a  latency  period  of  min.  70  ms.  Please  also  refer  to  the  relevant  legislation  of  each 

country  (For  Germany  for  example:  BGI  810-4  (Anhang  2)  "Sicherheit  bei  Produktionen  und 

Veranstaltungen - Scheinwerfer"). 

5)

 Color Temperature

    

At anytime the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

O

O

n

n

e

e

 can be used the color correction for every RGB color.   

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

18

 

4

4

 

  Maintaining and Cleaning the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e

 

 

The 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e

 

 is a low maintenance fixture. It is only necessary to clean 

the lenses, air inlets and outlets from time to time. For safe operation it is absolutely 

essential  that  the  fixture  is  kept  clean  and  that  dust,  dirt  and  smoke-fluid  residues 

must not build up on, or within, the fixture. If they do, the fixture's light output will be 

significantly reduced, and damages to the fixture may occur. Regular cleaning will not 

only  ensure  the  maximum  light  output,  but  will  also  allow  the  fixture  to  operate 

reliably  throughout  its  entire  life.  Under  no  circumstances  should  alcohol  or 

solvents be used to clean the fixture or its lenses! 

4.1  Safety regulations 

  Disconnect the fixture from the mains power before commencing any 

maintenance work! 

  Wait minimum 15 minutes after removing the power to allow the fixture to 

cool down. 

4.2  Maintenance Intervals (rule-of-thumb) 

The  maintenance  schedule  of  any  given  fixture  depends  on  the  installation 

environment. Hence no specific guidelines can be given. The cleaning intervals 

given  below  are  suggestions,  based  on  practical  experience. We  suggest  that 

you  start  with  these  and  develop  your  own  maintenance  schedule  as  you  see 

the fixtures performance in your specific environment.  

 

 

Maintenance Task 

Interval 

How 

Outside optic 

weekly 

soft cloth and glass cleaning fluid 

Inside lens 

yearly 

soft cloth no glass cleaning fluid 

Fan and air channel 

monthly 

vacuum cleaner, airbrush, etc. 

Moveable parts 

yearly 

suitable fatty oil 

 

Attention: 

  Never let optical parts come into contact with oil or fat. 

  Before running the fixture wait until all parts are touch dry. 

  Never touch lenses with bare fingers. 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

19

 

5  Technical Specifications 

Power supply 
Power consumption 

700 VA (Watt)  

Power input 

Auto sensing 100-240 V AC, 50-60 Hz 

Fuse protection 

Micro-fuse 6.3x32 mm, T8A 

Operational Parameters 
Max. ambient temp. 

45°C / 113°F (integrated overheating switch)  

Mounting position 

Any (See Mounting chapter) 

Lighting System - Additive Color mixing 
LED type 

400W RGB LED Chipset 

Lifetime 

20.000 h 

Shutter / Dimmer (8/16 Bit) 
Strobe  Effect with variable speed between 1 & 50 flashes per second, Random strobe, 
Pulse effects 
Continuous dimmer 0 - 100% 

Zoom (8/16 Bit) 

Zoom range 3° - 60° 

Focus (8/16 Bit) 
Motor driven focus from near (2 mtr.) to infinity 

DMX Control 
Standard USITT DMX-512, 3/5 pole XLR; [+] = Pin 3    [-] = Pin 2    [Ground] = Pin 1.  

Pan / Tilt (8/16 Bit) - 3 phase stepper motor 
Pan- movement 

540° (Position Feedback) 

Tilt- movement 

280° (Position Feedback) 

Weights and Measures  
Width of the base 

472 mm / 18.6 inch. 

Length of the base 

230mm / 9 inch. 

Height (head vertical) 

615mm / 24,2 inch. 

Fixture weight  

22 kg / 48.5 lbs.  

Floor stand  weight  

2 kg / 4.4 lbs. 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

20

 

6  Index 

A

 

Anleitung Version ............................................ 1 

B

 

BGV C1............................................................ 7 

C

 

Circumference ............................................... 18 
Cleaning......................................................... 18 

D

 

Description of Device ....................................... 4 
DIN VDE 0711-217 .......................................... 7 
DMX ................................................................. 9 

E

 

e-mail ............................................................... 1 
Enter-key ....................................................... 10 
Eyelets ............................................................. 7 

G

 

Geräteübersicht ............................................. 4 

H

 

Half-couplers (clamps) ..................................... 8 

I

 

Internet............................................................. 1 

L

 

LED Class 2M ................................................. 5 

M

 

Maintenance .................................................. 18 
Menu Field ..................................................... 10 

Menüfeld ...................................................... 10 
Micro-fuse ....................................................... 9 
Mode-key ...................................................... 10 
Mounting ........................................................ 6 
Mounting in hanging Position .......................... 8 
Mounting on the Floor ..................................... 7 

O

 

Optical parts ................................................ 18 

P

 

Pan- Movement ............................................. 19 
Power Supply ................................................ 9 
Powercon (Netzanschluss .............................. 4 

S

 

Safety distance ............................................... 6 
Safety Instructions .......................................... 5 
Secure the Device ......................................... 9 
Software Version ............................................. 1 

T

 

Tilt- Movement .............................................. 19 

U

 

Up/Down-keys .............................................. 10 

V

 

VBG 70 ........................................................... 7 

W

 

Warranty claims .............................................. 6 
Weights and Measures ................................. 19 

 

 

 

 

 

 

 

 

 

 


background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

21