Full Text Searchable PDF User Manual

Instruction Manual
from software version 1.02
(Instruction version 1.01)
e-mail: service@glp.de
Internet: http://www.glp.de

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
2
Notes:

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
3
Table of contents
1
Description of Device.............................................................................................. 4
1.1
Safety Instructions ............................................................................................ 5
2
Preparation and Installation ................................................................................... 6
2.1
Mounting ........................................................................................................... 6
2.1.1
Mounting on the floor (upright) ............................................................. 7
2.1.1
Mounting in hanging position (Head down) .......................................... 8
2.1.2
Mounting in sideways position ............................................................. 8
2.2
Securing the device .......................................................................................... 9
2.3
Connections ...................................................................................................... 9
2.3.1
Power Supply....................................................................................... 9
2.3.2
DMX ..................................................................................................... 9
3
The Menu Field ...................................................................................................... 10
4
4
Maintaining and Cleaning the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e ......................................... 18
4.1
Safety regulations ........................................................................................... 18
4.2
Maintenance Intervals (rule-of-thumb) ............................................................ 18
5
Technical Specifications ...................................................................................... 19
6
Index ....................................................................................................................... 20

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
4
1 Description of Device
1. Moving Head
2. Arm with various cooling vents
3. Tilt-lock to secure and lock the
tilt movement
4. Backlight LCD graphical menu
(data entry)
5. Base with various connectors
and Camlock mounting
system
6. DMX- Output (5 Pin)
7. DMX- Output (3 Pin)
8. Micro-fuse 6.3x32mm, T8A
9. Power Switch
10. 2x Safety wire points
11. Neutrik Powercon (Mains power
input)
12. Blank panel (primed for Ethernet)
13. DMX- Input (3 Pin)
14. DMX- Input (5 Pin)
Note: Only connect one cable to the
DMX Input / Output at the same time!
Base Side 1
10
6
7
8
9
10
Base Side 2
11 12
13
14
1
2
3
4
5

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
5
1.1
Safety Instructions
The
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e
is an advanced technology product.
To guarantee smooth operation, it is necessary to follow the
following instructions.
The manufacturer of this device will not take responsibility of
damages through any disregard of the information in this user
manual. Warranty claims will also be cancelled in the event of
the system casing being opened.
1. Make sure that before powering up the fixture, the fans and air inlets are
clean and not blocked by anything.
2. Before powering up the fixture, ensure that the moving head part of the
fixture can rotate unhindered through its full range of movement.
3. A safety distance of at least 0.5 m to any easily flammable material (e.g.
decoration material) must be adhered to.
4. Attention! Don’t touch the device during operation. Parts of the fixture can
become hot and can cause injuries and / or damages.
5. Use only one DMX Input / Output at the same time.
6. Never look directly into the beam of light or one of the LEDs. Never use
optical apertures with a distance less than 0.5 m to observe the beam of
light. LED Class 2M. Not following these precautions can result in serious
injury to your eyes and in particular, your retina.
Attention: LED Class 2M can cause injuries of your eyes even
without optical instruments in front of them or within a distance
of less than 0.5m and short exposure time.
Avoid direct radiation to your eyes!
7. To ensure proper operation, you must also follow the installation guide
described in chapter 2 of this manual. Operating the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e
without suitable mounting devices can increase the risk of an accident.
8. The
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e features a unique small and lightweight design
with no specific carrying handles. Care needs to be shown when handling
the fixture to ensure that no unnecessary damage should occur. Fragile
areas include the LCD display and cover on one side arm and the front
bezel. Pressure in these areas could result in damages which will not be
covered by the standard warranty.
9. Repair, maintenance and installation work should only be performed by
qualified or GLP certified staff. You need to pay attention to the common

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
6
rules of technology that are not explicitly mentioned in this manual.
10. Use only original spare parts. Any structural modification on the system will
terminate all warranty claims.
11. Please keep this instruction manual for future reference.
2 Preparation and Installation
2.1 Mounting
The
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e is fully operational whether it hangs or is mounted
to a wall. It can also be operated while standing on the floor. Keep a safety
distance of 0.5 m from any easily inflammable materials (decoration etc.).

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
7
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified personal only.
For the various mounting positions of the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e (standing on
the floor, sideways or hanging) different accessories kits are available. Using
any required kits, along with the standard mounting connectors on the base of
the fixture, will ensure a safe and firm installation.
2.1.1 Mounting on the floor (upright)
To operate the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e in an upright position, please use
the dedicated floor-stand which is shipped with all original fixtures. The
floor stand is mounted to the base of the
fixture using the two Camlock quarter turn
fasteners. Line up and engage the camlock
connectors from the floor stand into the base
of the fixture and turn the two fasteners 90°
to lock them. Do the opposite to release
them again. On both sides you'll find eyelets
to pull though a ratchet strap. This allows
additional bracing of the floor-stand during
upright operation.
M10
Gewinde
Camlock
Camlock
thread

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
8
2.1.1 Mounting in hanging position (Head down)
To operate the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e in a hanging position, two omega
brackets can be mounted directly to the bottom of the base using the
four Camlock connectors.
2.1.2 Mounting in sideways position
To operate the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e in a sideways position, please
use an additional mounting bar, available from GLP or one of their
agents. This mounting bar is fixed via the four camlock quick-release
connectors. Two half-couplers or clamps are then used to hang fixture.
This technique is necessary to cope with the additional torque in this
mounting position. Never use the "Mounting in hanging position"
technique described above to secure the fixture in a sideway position, as
Camlock
Eyelet

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
9
the fixtures base can become damaged, and a secure installation cannot
be assured.
2.2 Securing the device
Regardless of the mounting method of the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e you'll have to
use a secondary safety wire. This safety wire can be attached to the fixture by
threading it through one of the two holes provided on the base of the fixture.
Ensure that the safety wire is securely fastened through the fixture and the
fixtures mounting support. Install a safety wire that can hold at least 10 times
the weight of the fixture.
2.3 Connections
2.3.1 Power Supply
Autosensing ~100-240 Volt AC, 50-60 Hz, earth contact type plug via
Powercon
Connected load 450 VA (W)
<=>
T8A (micro-fuse 6.3x32mm)
Disconnect from the mains supply before changing the fuse and
use only the above described micro-fuse type.
2.3.2 DMX
USITT DMX-512 Standard input/output via 3 pin and 5 pin connectors.
3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+]
5 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] / Pin 4/5 n.c.
Ethernet (Artnet II compatible, ACN ready)
Neutrik RJ-45 plug (for Neutrik EtherCon connector with body)

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
10
3
The Menu Field
You’ll find the control board on the side of the arm. It allows you to make all necessary
adjustments of the
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
W
W
a
a
s
s
h
h
O
O
n
n
e
e
.
. With the Menu-key you get into the main
menu. Afterwards you can navigate through the menu with the Touchwheel. Push the
Enter-key to get to the next menu level or to confirm your settings. Select ON/ OFF function
settings with the Touchwheel. Confirm and save with the Enter-key. Push the Back-key to
cancel the entry and go back to the main menu.
Back - Enter
Layer 1
Layer 2
Layer 3
Layer 4
Notes
DMX Start
Address
Set the DMX start address
Personality Pan/Tilt
Pan/Tilt settings
Pan invert
Selects Inverse Pan, on or off
Tilt invert
Selects Inverse Tilt, on or off
Feedback
Automatic position feedback selection for
pan/tilt movement
Color
Dimmer
Curve
Set the Dimmer Curve
DMX
Address
Set the DMX start address
Mode
Allows selection of the desired DMX Mode
Compressed
Fixture works in "Compressed" mode
see
also section 4
Normal
Fixture works in "Normal" mode
see also
section 4
High-
Resolution
Fixture works in "High Resolution" mode
see also section 4
Hold Values
Defines whether the last DMX signal is
stored, or the lamp is switched OFF in case
of signal interruption
Manual
Manual control of all system functions
Pan
Manual control
Tilt
Manual control
Color
Manual control
Impression wash.one
1
V1.02

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
11
Red
Manual control
Green
Manual control
Blue
Manual control
Shutter
Manual control
Dimmer
Manual control
Color temp.
Manual control
Special
Manual control
Movement
Manual control
Movement
Speed
Manual control
Zoom
Manual control
Focus
Manual control
Beam
Shaper
Manual control
Beam
Shaper Size
Manual control
Display
Adjustments for the Display
Blackout
Sets the display On or Off
Auto-Rot
Display will rotate automatically
Display Inv
Display will rotate manual
Brightness
Display backlight
Set Default
Resetting all functions to original values
Status
Version
Shows the current software version
Reset
Hardware
Hardware reset adjust
All
Reset all boards
Head
Reset only headboard
FZE
Reset only Focus Zoom
Pan
Reset only Pan
Tilt
Reset only Tilt
Temperatures
Display all temperatures
LED Info
Display the values for the LED´s
Red
Current value for red
Green
Current value for green
Blue
Current value for blue
Error Status
Shows the error status (N/A)
Timer
Shows the life time
DMX Input
Shows the current DMX signal per DMX
channel
Pan
Instantaneous value for pan
Tilt
Instantaneous value for tilt

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
12
Color
Instantaneous value for color
Red
Instantaneous value for red
Green
Instantaneous value for green
Blue
Instantaneous value for blue
Shutter
Instantaneous value for shutter
Dimmer
Instantaneous value for dimmer
Colortemp.
Instantaneous value for color temp.
Special
Instantaneous value for special
Movement
Instantaneous value for movement
Movement
Speed
Instantaneous value for movement speed
Zoom
Instantaneous value for zoom
Focus
Instantaneous value for focus
Beam
Shaper
Instantaneous value for shaper size
Beam
Shaper Size
Instantaneous value for beam shaper
DMX Quality
Shows the DMX Quality
Service
Adjust
Enter Code
Adjustments for all functions. Use code to
enter calibration. (only for authorized
persons with code)
Pan
Adjust for pan
Tilt
Adjust for tilt
Beam Shape
Arm
Adjust for Beam Shaper arm
Beam Shape
Rot
Adjust for Beam Shaper rotation
Beam Shape
Size
Adjust for Beam Shaper size
Super Beam
Adjust for Super Beam
Zoom
Adjust for zoom
Focus
Adjust for focus
Adjust
Default set
Set all adjustments to default
Factory
Adjust
Factory internal adjustments
Testmode
Test mode(N/A)
Diagnose
Diagnose functions (N/A)
Error Log
Shows all errors in lifetime (N/A)

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
13
DMX Channels
Normal-Mode 18 DMX Channels
Channel
Function
Time and Value
DMX
HEX
%
1) PAN- coarse
0 .. 540°
0..255
00..FF
0..100
2) PAN-fine
High- Pos ... High- Pos +
2,6° (16 Bit)
0..255
00..FF
0..100
3) Tilt- coarse
0 .. 280°
0..255
00..FF
0..100
4) Tilt-fine
High- Pos … High- Pos +
1,2° (16 Bit)
0..255
00..FF
0..100
5) Color
Colors adjustable via RGB
0..7
00..07
0..2,5
(fixed)
Color 01 - Red
8..15
08..0F
3..5,5
Color 02 - Amber
16..23
10..17
6..8,5
Color 03 – Yellow warm
24..31
18..1F
9..12,5
Color 04 - Yellow
32..39
20..27
13..15,5
Color 05 – Green
40..47
28..2F
16..18,5
Color 06 – Turquoise
48..55
30..37
19..21,5
Color 07 – Cyan
56..63
38..3F
22..24,5
Color 08 - Blue
64..71
40..47
25..27,5
Color 09 - Lavender
72..79
48..4F
28..30,5
Color 10 - Malve
80..87
50..57
31..34,5
Color 11 – Magenta
88..95
58..5F
35..37,5
Color 12 - Pink
96..103
60..67
38..40,5
White - CTO
Color temp.
3200K
104..111
68..6F
41..43,5
White
Color temp.
5600K
112..119
70..77
44..46,5
White – CTB
Color temp.
7200K
120..127
78..7F
47..49,5
Rainbow Effect Stop
128
80
50
Rainbow Effect
slow - fast
129..223
81..DF
51..88
6) Red
Color mixing system - Red
0 - 100%
0..255
00..FF
0..100
7) Green
Color mixing system -
Green
0 - 100%
0..255
00..FF
0..100
8) Blue
Color mixing system - Blue
0 - 100%
0..255
00..FF
0..100
9) Shutter
Shutter closed
0..15
00..0F
0..5,5
Shutter pulse random
slow – fast
16..47
10..2F
6..18,5
Shutter ramp up
slow – fast
48..79
30..4F
19..31
Shutter ramp down
slow – fast
80..111
50..6F
32..43
Shutter ramp up/down
slow – fast
112..143
70..8F
44..56
Random strobe
slow – fast
144..159
90..9F
57..62
Strobe effect pause
5s …0,1s
160..199
A0..C7
63..77
Strobe effect slow - fast
1 Hz .. 25 Hz
200..241
C8..F1
78..95
Shutter open
242..255
F2..FF
96..100
10) Dimmer
Dimmer
0% - 100%
0..255
0..FF
0..100
11) Color temp.
No color temperature
correction
0..7
0..07
0..2,5
Continuous color
temperature correction
between 7200k - 3200k
Applicable for ALL
colors
5)
8..255
08..FF
3..100
12) Special
RESET 1
250..253
FA..FC
98..99
RESET 2
254..255
FD..FF
100

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
14
13) Movement
No movement
0
0
0
Movement
Size
Phase
PAN
1
0°
01..01
1
90°
02..03
1
180°
04..05
1
270°
06..07
PAN
2
0°
08..09
2
90°
10..11
2
180°
12..13
2
270°
14..15
PAN
3
0°
16..17
3
90°
18..19
3
180°
20..21
3
270°
22..23
PAN
4
0°
24..25
4
90°
26..27
4
180°
28..29
4
270°
30..31
TILT
size / phase see also
PAN
32..63
20..3F
13..25
PAN / TILT
size / phase see also
PAN
64..95
40..5F
26..37
PAN / TILT (inverse)
size / phase see also
PAN
96..127
60..7F
38..50
Circle
size / phase see also
PAN
128..159
80..9F
51..62
Circle (inverse)
size / phase see also
PAN
160..191
A0..BF
63..75
Lying eight
size / phase see also
PAN
192..223
C0..DF
76..87
Random movement
size see also PAN
224..255
E0..FF
88..100
14) Speed
Pan/Tilt relative movement
0..1
00..01
0..0,5
Pan/Tilt
Pan/Tilt slow – fast
Use this channel 14) also
for the speed of the
movements (channel 13).
Pan Min. 540°
Pan Max. 540°
Tilt Min. 280°
Tilt Max. 280°
2..255
02..FF
1..100
15) Zoom
Super Beam
3°
0 .. 4
00..04
0..1
Spot - Flood
7° - 60°
5 .. 255
05..255
2..100
16) Focus
Hard - Soft
0 – 100%
0 .. 255
0..FF
0..100
17) Shaper Size
Open - Close
0 - 100%
0..255
00..FF
0..100
18) Beam Shaper Rotate
0° - 200°
0..255
00..FF
00..100

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
15
Compress-Mode 14 DMX Channels
Channel
Function
Time and Value
DMX
HEX
%
1) PAN- coarse
0 .. 540°
0..255
00..FF
0..100
2) PAN-fine
High- Pos ... High- Pos +(16
Bit)
0..255
00..FF
0..100
3) Tilt- coarse
0 .. 280°
0..255
00..FF
0..100
4) Tilt-fine
High- Pos … High- Pos +
(16 Bit)
0..255
00..FF
0..100
5) Color
Colors adjustable via RGB
0..7
00..07
0..2,5
(fixed)
Color 01 - Red
8..15
08..0F
3..5,5
Color 02 - Amber
16..23
10..17
6..8,5
Color 03 – Yellow warm
24..31
18..1F
9..12,5
Color 04 - Yellow
32..39
20..27
13..15,5
Color 05 – Green
40..47
28..2F
16..18,5
Color 06 – Turquoise
48..55
30..37
19..21,5
Color 07 – Cyan
56..63
38..3F
22..24,5
Color 08 - Blue
64..71
40..47
25..27,5
Color 09 - Lavender
72..79
48..4F
28..30,5
Color 10 - Malve
80..87
50..57
31..34,5
Color 11 – Magenta
88..95
58..5F
35..37,5
Color 12 - Pink
96..103
60..67
38..40,5
White - CTO
Color temp. 3200K
104..111 68..6F
41..43,5
White
Color temp. 5600K
112..119
70..77
44..46,5
White – CTB
Color temp. 7200K
120..127 78..7F
47..49,5
Rainbow Effect Stop
128
80
50
Rainbow Effect
slow - fast
129..223 81..DF
51..88
6) Red
Color mixing system - Red
0 - 100%
0..255
00..FF
0..100
7) Green
Color mixing system -Green 0 - 100%
0..255
00..FF
0..100
8) Blue
Color mixing system - Blue
0 - 100%
0..255
00..FF
0..100
9) Shutter
Shutter closed
0..15
00..0F
0..5,5
Shutter pulse random
slow – fast
16..47
10..2F
6..18,5
Shutter ramp up
slow – fast
48..79
30..4F
19..31
Shutter ramp down
slow – fast
80..111
50..6F
32..43
Shutter ramp up/down
slow – fast
112..143 70..8F
44..56
Random strobe
slow – fast
144..159 90..9F
57..62
Strobe effect pause
5s …0,1s
160..199 A0..C7
63..77
Strobe effect slow - fast
1 Hz .. 25 Hz
200..241 C8..F1
78..95
Shutter open
242..249 F2..F9 95,5..96,5
RESET 1
Only Head
250
FA
97
RESET 2
All Funktions
251
FB
98
Shutter open
252..255 FC..FF
99..100
10) Dimmer
Dimmer
0% - 100%
0..255
0..FF
0..100
11) Zoom
Super Beam
3°
0 .. 4
00..04
0..1
Spot - Flood
7° - 60°
5 .. 255
05..255
2..100
12) Focus
Hard - Soft
0 – 100%
0 .. 255
0..FF
0..100
13) Shaper Size
Open - Close
0 - 100%
0..255
00..FF
0..100
14) Beam Shaper Rotate
0° - 200°
0..255
00..FF
00..100

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
16
High Resolution (Extended)-Mode 24 DMX Channels
Channel
Function
Time and Value
DMX
HEX
%
1) PAN- coarse
0 .. 540°
0..255
00..FF
0..100
2) PAN-fine
High- Pos ... High- Pos + (16
Bit)
0..255
00..FF
0..100
3) Tilt- coarse
0 .. 280°
0..255
00..FF
0..100
4) Tilt-fine
High- Pos … High- Pos + (16
Bit)
0..255
00..FF
0..100
5) Color
Colors adjustable via RGB
0..7
00..07
0..2,5
(fixed)
Color 01 - Red
8..15
08..0F
3..5,5
Color 02 - Amber
16..23
10..17
6..8,5
Color 03 – Yellow warm
24..31
18..1F
9..12,5
Color 04 - Yellow
32..39
20..27 13..15,5
Color 05 – Green
40..47
28..2F 16..18,5
Color 06 – Turquoise
48..55
30..37 19..21,5
Color 07 – Cyan
56..63
38..3F 22..24,5
Color 08 - Blue
64..71
40..47 25..27,5
Color 09 - Lavender
72..79
48..4F 28..30,5
Color 10 - Malve
80..87
50..57 31..34,5
Color 11 – Magenta
88..95
58..5F 35..37,5
Color 12 - Pink
96..103
60..67 38..40,5
White - CTO
Color temp.
3200K
104..111 68..6F 41..43,5
White
Color temp.
5600K
112..119 70..77 44..46,5
White – CTB
Color temp.
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop
128
80
50
Rainbow Effect
slow - fast
129..223 81..DF
51..88
6) Red- coarse
Color mixing system – Red
0 - 100%
0..255
00..FF
0..100
7) Red-fine
Color mixing system – Red-
low
0..255
00..FF
0..100
8) Green- coarse
Color mixing system – Green 0 - 100%
0..255
00..FF
0..100
9) Green- fine
Color mixing system –
Green-low
0..255
00..FF
0..100
10) Blue- coarse
Color mixing system – Blue
0 - 100%
0..255
00..FF
0..100
11) Blue-fine
Color mixing system – Blue-
low
0..255
00..FF
0..100
12) Shutter
Shutter closed
0..15
00..0F
0..5,5
Shutter pulse random
slow – fast
16..47
10..2F
6..18,5
Shutter ramp up
slow – fast
48..79
30..4F
19..31
Shutter ramp down
slow – fast
80..111
50..6F
32..43
Shutter ramp up/down
slow – fast
112..143 70..8F
44..56
Random strobe
slow – fast
144..159 90..9F
57..62
Strobe effect pause
5s …0,1s
160..199 A0..C7
63..77
Strobe effect slow - fast
1 Hz .. 25 Hz
200..241 C8..F1
78..95
Shutter open
242..255 F2..FF 96..100
13) Dimmer-
coarse
Dimmer
0% - 100%
0..255
0..FF
0..100
14) Dimmer- fine
Dimmer low
0..255
0..FF
0..100
15) Color temp.
No color temperature
correction
0..7
0..07
0..2,5
Continuous color temperature
correction between 7200k -
3200k
Applicable for ALL
colors
5)
8..255
08..FF
3..100

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
17
16) Special
RESET 1
250..253 FA..FC
98..99
RESET 2
254..255 FD..FF
100
17) Zoom coarse
Super Beam
3°
0 .. 4
00..04
0..1
Spot - Flood
7° - 60°
5 .. 255 05..255
2..100
18) Zoom fine
Zoom low
(0% - 100%)
0..255
0..FF
0..100
19) Focus coarse
Hard - Soft
0% – 100%
0 .. 255
0..FF
0..100
20) Focus fine
Focus low
(0% - 100%)
0..255
0..FF
0..100
21) Shaper Size
coarse
Open - Close
0 - 100%
0..255
00..FF
0..100
22) Shaper Size
fine
Shaper low
(0% - 100%)
0..255
00..FF
00..100
23) Beam Shaper
coarse
Rotate
0° - 200°
0..255
00..FF
00..100
24) Beam Shaper
fine
Iris low
(0% - 100%)
0..127
00..7F
00..50
Locking and unlocking the Control Panel
The Display will auto look automatically if the Touch Panel will not use for 10s. To unlook the Touch
Panel you have to press one of the menu buttons for 2s..
1)
Colors
The predefined colors can be used as start colors for the Rainbow effect. First select a desired start
color, then activate the rainbow effect. All
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
O
O
n
n
e
e
will then begin from that color
and execute the rainbow effect synchronously. Different
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
O
O
n
n
e
e
can have
different start colors but will still execute the rainbow effect synchronously. If you choose a color
different from the ones marked with
1)
in the tables above the rainbow start-color will be red.
2)
Rainbow-effect Stop
will pause this function. After resuming the rainbow-effect will be continued with the current color.
3)
The Rainbow-effect
will run synchronously only if it is started from one of the predefined colors (see also
1)
before).
4)
Attention:
Please note that shutter frequencies over 10 Hz are prohibited in some countries. Especially
frequencies in the range of 5 - 12 Hz can possibly cause epileptic seizures
continuous blink
irritation with a latency period of min. 70 ms. Please also refer to the relevant legislation of each
country (For Germany for example: BGI 810-4 (Anhang 2) "Sicherheit bei Produktionen und
Veranstaltungen - Scheinwerfer").
5)
Color Temperature
At anytime the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
O
O
n
n
e
e
can be used the color correction for every RGB color.

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
18
4
4
Maintaining and Cleaning the
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e
The
I
I
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
W
W
a
a
s
s
h
h
o
o
n
n
e
e
is a low maintenance fixture. It is only necessary to clean
the lenses, air inlets and outlets from time to time. For safe operation it is absolutely
essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues
must not build up on, or within, the fixture. If they do, the fixture's light output will be
significantly reduced, and damages to the fixture may occur. Regular cleaning will not
only ensure the maximum light output, but will also allow the fixture to operate
reliably throughout its entire life. Under no circumstances should alcohol or
solvents be used to clean the fixture or its lenses!
4.1 Safety regulations
•
Disconnect the fixture from the mains power before commencing any
maintenance work!
•
Wait minimum 15 minutes after removing the power to allow the fixture to
cool down.
4.2 Maintenance Intervals (rule-of-thumb)
The maintenance schedule of any given fixture depends on the installation
environment. Hence no specific guidelines can be given. The cleaning intervals
given below are suggestions, based on practical experience. We suggest that
you start with these and develop your own maintenance schedule as you see
the fixtures performance in your specific environment.
Maintenance Task
Interval
How
Outside optic
weekly
soft cloth and glass cleaning fluid
Inside lens
yearly
soft cloth no glass cleaning fluid
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Moveable parts
yearly
suitable fatty oil
Attention:
•
Never let optical parts come into contact with oil or fat.
•
Before running the fixture wait until all parts are touch dry.
•
Never touch lenses with bare fingers.

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
19
5 Technical Specifications
Power supply
Power consumption
700 VA (Watt)
Power input
Auto sensing 100-240 V AC, 50-60 Hz
Fuse protection
Micro-fuse 6.3x32 mm, T8A
Operational Parameters
Max. ambient temp.
45°C / 113°F (integrated overheating switch)
Mounting position
Any (See Mounting chapter)
Lighting System - Additive Color mixing
LED type
400W RGB LED Chipset
Lifetime
20.000 h
Shutter / Dimmer (8/16 Bit)
Strobe Effect with variable speed between 1 & 50 flashes per second, Random strobe,
Pulse effects
Continuous dimmer 0 - 100%
Zoom (8/16 Bit)
Zoom range 3° - 60°
Focus (8/16 Bit)
Motor driven focus from near (2 mtr.) to infinity
DMX Control
Standard USITT DMX-512, 3/5 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
Pan / Tilt (8/16 Bit) - 3 phase stepper motor
Pan- movement
540° (Position Feedback)
Tilt- movement
280° (Position Feedback)
Weights and Measures
Width of the base
472 mm / 18.6 inch.
Length of the base
230mm / 9 inch.
Height (head vertical)
615mm / 24,2 inch.
Fixture weight
22 kg / 48.5 lbs.
Floor stand weight
2 kg / 4.4 lbs.

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
20
6 Index
A
Anleitung Version ............................................ 1
B
BGV C1............................................................ 7
C
Circumference ............................................... 18
Cleaning......................................................... 18
D
Description of Device ....................................... 4
DIN VDE 0711-217 .......................................... 7
DMX ................................................................. 9
E
e-mail ............................................................... 1
Enter-key ....................................................... 10
Eyelets ............................................................. 7
G
Geräteübersicht ............................................. 4
H
Half-couplers (clamps) ..................................... 8
I
Internet............................................................. 1
L
LED Class 2M ................................................. 5
M
Maintenance .................................................. 18
Menu Field ..................................................... 10
Menüfeld ...................................................... 10
Micro-fuse ....................................................... 9
Mode-key ...................................................... 10
Mounting ........................................................ 6
Mounting in hanging Position .......................... 8
Mounting on the Floor ..................................... 7
O
Optical parts ................................................ 18
P
Pan- Movement ............................................. 19
Power Supply ................................................ 9
Powercon (Netzanschluss .............................. 4
S
Safety distance ............................................... 6
Safety Instructions .......................................... 5
Secure the Device ......................................... 9
Software Version ............................................. 1
T
Tilt- Movement .............................................. 19
U
Up/Down-keys .............................................. 10
V
VBG 70 ........................................................... 7
W
Warranty claims .............................................. 6
Weights and Measures ................................. 19

GLP
German Light Products GmbH
(Instruction version 1.01) / from software version 1.02
21