GPB-7000 

 

Gerber Prime Boiler Control Panel 

 

 

 

 

 
 
 
 
 
 
 
 

 

 

Note: The power cord must meet 1.25mm簡 or 16AWG or better 

 

 

This Gerber Prime Boiler GPB-7000 is a security enabled wireless device, based on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturers Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  switch  is  possible  with  other  manufacturers  wireless  Controller.  GPB-7000  is 
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that 
the signal is received by its intended destination by routing the signal around obstacles 
and radio dead spots. Because GPB-7000 supports Security Command Class, it can 
learn  with  Secured  controller.  Its  functionality  and  supported  command  classes  is 
identical when included as a secure and non-secure device.

 

 

GPB-7000 is able to detect instance wattage (3840/EU, 1920/US) and overload current 

(16A) of connected lights or appliances. When detecting overload state, the switch will 
be  turned  off  and  its  On/Off  function  will  be  lockout  of  which  LED  will  flash  quickly.   
However,  disconnect  and  re-connect  the  switch  will  reset  its  overload  condition  to 
normal status.

 

 

Safety Precautions and Installation 

 

 

Avoid installing the unit in storming or raining weather. 

 

 

Be sure to isolate or switch off power source before installing or 
maintenance. 

 

 

Do ensure that the power supply circuit protected by a 16A circuit breaker or 
suitable equivalent fuse. 

 

IMPORTANT

 

 

Installation must be performed by skilled technicians who are informed about 
the standards and technical requirements of the appliance and its proper 
installation. 

 

 

Check your local codes as they apply to your situation. If the house wiring is 
of aluminum, consult with an electrician about proper wiring methods. 

 

Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING 
CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL 
SHOCK.   

 

 

Adding to Z-Wave

TM

 Network

 

 

In the front casing, there are thee touch buttons with LED indicator, 

, which 

is used to toggle switch on and off or carry out inclusion, exclusion, reset. When first 
power  is  applied,  its  LED  flashes  on  and  off  alternately  and  repeatedly  at  2  second 
intervals. It implies that it has not been assigned a node ID. 

 

 

Smart Start

 

 

Before adding GPB-7000 into the Z-wave network, the controller should scan its QR

 

code. Then connect the AC power to GPB-7000, the learning procedure will progress

 

automatically.

 

 

Note:

    Unlike inclusion function as shown in the table below, the execution of 

smart start is free from pressing the On/Off button on the Switch.

 

 

The table below lists an operation summary of basic Z-Wave functions. Please refer 
to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to Add/Remove/associate devices

 

 


background image

 

 
 

Function 

Description 

Annotation 

No node ID 

The Z-Wave Controller does not 
allocate a node ID to the Switch. 

LED 2-second on, 2-
second off 

Add

 

1.Put your Z-Wave controller into 

 

inclusion mode by following the 

 

instructions provided by the 

 

controller manufacturer. 

 

 
 
 
 
 
 
 
 
 
  

LED blink three times.

 

 

2. Press and hold 

 button first,

 

        then press 

 button three times

 

      within 2 seconds will enter inclusion

 

      mode.

 

Remove

 

1.Put your Z-Wave controller into 

 

exclusion mode by following the 

 

instructions provided by the 

 

controller manufacturer.

 

 
 
 
 
 
 
 
 
 

LED blink three times.

 

2. Press and hold 

 button first,

 

        then press 

 button three times

 

        within 2 seconds will enter exclusion

 

        mode.

 

3. Node ID has been excluded.

 

 

Reset

 

1. Press and hold 

 button first,

 

        then press 

 button three times

 

        within 2 seconds will enter inclusion

 

        mode.

 

Use this procedure only in 

 

the event that the primary 

 

controller is lost or 

 

otherwise inoperable.

 

2.Within 1 second, press 

 button 

again and hold for 5 seconds.

 

3. IDs are excluded.

 

LED 2-second on, 2-second 
off

 

Adding a node ID allocated by Z-Wave Controller means inclusion.    Removing a node

 

ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 
 
LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification.

 

 

State Type

 

LED Indication

 

Normal

 

Under normal operation, short pressing 

  

 button will turn On 

and Off. When switch turns on, green LED lights up, whereas turns 
off, red LED is lights up.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the 

  

 LED flashes on and off alternately at 2-second 

intervals. 

 

Learning

 

When GPB-7000 enter include or exclude mode by pressing the 
combination of 

  

 button and 

 button 

 LED will flashes 

three times 0.5 second intervals.

 

Overload

 

When overload state occurs, the switch is disabled of which 

 

LED flashes on and off alternately at 0.2 second intervals. Overload 
state can be cleared by disconnecting and reconnecting the Switch 
to the wall outlet.

 

 

 

 
Overview   
 
 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 


background image

 

 
 
Installation and Operation

 

 

1.  Plug this switch into a wall box near the load to be controlled. 

2.  Connects the load to the switch. Make sure the load to be controlled cannot exceed 

16A (Resistive Load). 

3.  Press the button or switch on the load to the ON position. 

4.  To manually turn ON the switch, short press the 

 button. The green 

 LED will 

turn ON, and the blue timer LEDs will also turn ON. Every passed 10 minutes will 

change one blue LED as a green LED. When all the blue LEDs changes, all the 

green LEDs will blink twice and turn off. Then the switch turns off and green 

 

LED changes to red 

 LED. 

5.  To manually turn OFF the Switch, short press the 

 button. The red LED will turn 

ON and the load connected to the switch will also turn OFF. 

6.  Every short press 

 button, there will be increasing one more blue LED. When 

arrives to the intended timer, stop pressing and all the blue LEDs will blink twice. 

Or you can press and hold 

 button, there will be increasing one more blue LED 

every half second. Every blue LED represents 10 minutes working time of switch. 

The maximum time is 110 minutes, and the default is 60 minutes.   

7.  Every short press 

 button, there will be decreasing one blue LED. This means 

the working time of switch decrease 10 minutes. The minimum time is 10 minutes. 

Or you can press and hold 

 button, there will be decreasing one blue LED every 

half second.

 

8.  After switch is turned on for a while, you can still decrease (or increase) the working 

time by pressing 

 button (or 

 button). When all the blue LEDs decreases to 

off, the switch will turn off.

 

 

Programming

 

 

1.    Basic Command Class / Binary Switch Command Class

 

GPB-7000 will respond to BASIC and BINARY commands that are part of the Z-
Wave system.

 

 

1-1 BASIC_GET / BINARY_SWITCH_GET

 

        Upon receipt of the following commands from a Z-Wave Controller, GPB-7000 will 

report its On/Off state to the node asked.

 

 

Basic Get Command: [Command Class Basic, Basic Get]

 

Basic Report Command:

 

Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]

 

Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get]

 

Binary Switch Report Command:

 

Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 
=0(0x00)]

 

Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 
255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET

 

        Upon  receipt  of  the  following  commands  from  a  Z-Wave  Controller,  the  load 

attached to GPB-7000will turn on or off.

 

 

[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]: the load attached 
to the switch turns on.

 

[Command  Class  Basic,  Basic  Set,  Value  =  0(0x00)]:  the  load  attached  to  the 
switch turns off.

 

[Command Class Switch Binary, Switch Binary Set, Value = 1~99, (255)0xFF]: the 
load attached to the switch turns on. 
[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  0(0x00)]:  the  load 
attached to the switch turns off. 

 
1.  Z-Waves Groups (Association Command Class Version 2) 
 

The Switch can be set to send reports to associated Z-Wave devices.    It supports one 

association group with one node support for Grouping 1. For group 1, the Switch will 

report its latest status to Z-Wave Controller.   
 
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, 
ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION. 
 

2-1 Auto report to Grouping 1 (Maximum Node 5) 

 


background image

 

 
2-1-1 On/Off Event Report   

      When on or off  state has been changed, it will send Binary Switch Report to the 

node of Grouping 1.   

       
Binary Switch Report 
 

ON:[Command Class Switch Binary, Switch Binary Report, Value =255(0xFF)] 
OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] 

 

2-1-2 Instant Power Consumption vary over 5% report 

When the power consumption of load vary over 5%, it will send Meter report to the 

nodes of Grouping 1. 
 

Meter  Report  Command:  [Command  Class  Meter

Meter  Report

Rate  Type  = 

0x01

Meter  Type  =  0x01

Precision  =  1

  Scale  =  0x02

  Size  =  4

Meter 

Value(W) 

 

  2-1-3 Overload alarm report 

When GPB-7000detects the current is more than 16A, it will send Alarm Report to 

Group 1 node. After detecting overload state and sending this alarm report, GPB-

7000 will turn off the relay automatically and lockout the 

 button. The only thing to 

do is disconnecting GPB-7000 and reduce the load. Then reconnect GPB-7000 and 

it will work again.

 

The content of Alarm Report 

 

Alarm report command:

    [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

Alarm Level = 0xFF]

Alarm Level = 0xFF]

Alarm Level = 0xFF]

Alarm Level = 0xFF] 

 
2-2 Response to Meter Get Command

 

      The switch will report its (1) instant Power Consumption (Watt) or (2) accumulated 

power consumption(KWH) or (3)

 

AC load Voltage (V) or (4)

 

AC load current ( I ) (5)

 

load power factor (PF) to Z-Wave Controller after receive the Meter Get Command 

from Z-Wave Controller.

 

 

2-2-1 Instant Power Consumption (Watt) of load

 

        When receiving Meter Get Command, it will report Meter Report Command to the 

node asked.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]

 

Meter Report Command:

 

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type = 

0x01

Precision = 1

Scale = 2

Size = 4

Meter Value(W)]

 

 

Example:

 

            Scale = 0x02 (W)

 

            Precision = 1

 

            Size = 4 Bytes (W)

 

Meter Value 1 = 0x00 (W)

 

Meter Value 2 = 0x00 (W)

 

Meter Value 3 = 0x03 (W)

 

Meter Value 4 = 0xEA (W)

 

Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W

 

 

2-2-2 Accumulated Power Consumption (KW/h)

 

When receiving Meter Get Command, it will report Meter Report Command to

 

the node.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]

 

Meter Report Command: [Command Class Meter

Meter Report

Rate Type = 

0x01

Meter Type = 0x01

Precision = 2

Scale = 0

Size = 4

Meter 

Value(KWh)]

 

       

 

          Example:

 

          Scale = 0x00 (KWh)

 

          Precision = 2

 

          Size = 4 Bytes (KW/h)

 

          Meter Value 1 = 0x00(KWh)

 

          Meter Value 2 = 0x01(KWh)

 

 


background image

 

          Meter Value 3 = 0x38(KWh)

 

          Meter Value 4 = 0xA3(KWh)

 

 
          Accumulated  power  consumption  (KW/h)  =  (Meter  Value  2*65536)  +  (Meter 

Value 3*256) + (Meter Value 4) = 800.35 (KW/h)

 

 
2-2-3 Clearing accumulated power consumption

 

     

 

Meter Reset Command: [Command Class Meter, Meter Reset]

 

 

2-2-4 AC load Voltage (V)

 

When receiving Meter Get Command, it will report Meter Report Command to the 
node.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)] 

 

 

 

Meter Report Command:

 

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type = 0x01

Precision = 1

Scale = 4

Size = 2

Meter Value(V)]

 

 
Example:

 

Scale = 0x04 (V)

 

Precision = 1 

 

Size = 2 Bytes (V)

 

Meter Value 1 =    0x09(V)

 

Meter Value 2 =    0x01(V)

 

AC load Voltage =    (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)

 

 
2-2-5 AC load current ( 

I

 )

 

        When receiving Meter Get Command, it will report Meter Report Command to the 
node.

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]

 

Meter Report Command:

 

[Command Class Meter

Meter Report

Rate Type  =  0x01

Meter Type  = 0x01

Precision = 2

Scale = 5

Size = 2

Meter Value(

I

)]

 

 
Example:

 

Scale = 0x05 (

I

)

 

Precision = 2 

 

Size = 2 Bytes (

I

)

 

Meter Value 1 = 0x01(

I

)

 

Meter Value 2 = 0x21(

I

)

 

AC load current = (Meter Value 1*256) +(Meter Value 2) = 2.89 (A)

 

 
2-2-6 load power factor (PF)

 

    When receiving Meter Get Command, it will report Meter Report Command to the 

node.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]

 

Meter Report Command:

 

[Command Class Meter

Meter Report

Rate Type  =  0x01

Meter Type  = 0x01

Precision = 2

Scale = 6

Size = 1

Meter Value(PF)

 

 
Example:

 

Scale = 0x06 (PF)

 

Precision = 2

 

Size = 1 (PF)

 

Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)

 

 
3.    Z-Waves Configuration

 

 

Configuration

 

Parameter

 

Function

 

Size

 

(Byte)

 

Value

 

Unit

 

Default

 

Description

 

1

 

Manual Switch 

Report mode

 

1

 

0-1

 

 

1

 

0 : Disable

 

1 : Enable

 

2

 

switch Working 

Timer

 

1

 

1-11

 

10min

 

6

 

6*10min=1 hour

 

3

 

Watt Meter 

Report Period

 

2

 

0x01-

 

0x7FFF

 

5s

 

720

 

720*5s=3600s=1 hour

 

4

 

KWH Meter 

Report Period

 

2

 

0x01-

 

0x7FFF

 

10min

 

6

 

6*10min=1 hour

 

5

 

Threshold of

 

current for Load

 

caution

 

2

 

10-1500

 

0.01A

 

1500

 

1500*0.01A = 15A

 

6

 

Threshold of

 

KWh for Load

 

caution

 

2

 

1-10000

 

1KWh

 

10000

 

10000*1KWh= 

10000KWh

 

7

 

Watt differential 
report mode

 

1

 

0-1

 

 

 

1

 

0: Disable

 

1: Enable

 

 


background image

 

 

3-1 Manual switch report mode

 

When GPB-7000 is turned on or turned off, it will send a Switch_Binary_report to the 

nodes of group1. If the setting value is 0, it will disable sending the report. 

 

3-2 switch Working Timer

 

This is a working time for the switch from turn to turn off. The maximum setting

 

value is from 11(11*10min=110min), and the default value is 6.

 

3-3 W

att 

Meter Report Period:

 

    If the setting is configured for 1hour (set value =720), the GPB-7000 will report its 

instant power consumption every 1 hour to Group1 node.    The maximum interval 

to report its instant power consumption is 45 hours (5s*32767/3600=45hr).

 

3-4 KWH Meter Report Period:

 

      If  the  setting  is  configured  for  1hour  (set  value  =6),  the  GPB-7000  will  report  its 

Accumulated  Power  Consumption  (KW/h)  every  1  hour  to  Group1  node.    The 

maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 

days (10min*32767/1440=227.55 days).

 

3-5 Threshold of current for Load Caution

 

This is a warning when the current of load over the preset threshold value, if the

 

setting value is 1500, when the load current of Relay1 over this value, GPB-7000

 

will send current meter report to warn the Group1 node, the Range of the setting

 

value is from 10 to 1500, and the default value is 1500.

 

3-6 Threshold of KWh for Load Caution

 

This is a warning when the KWh of load over the preset threshold value, If the

 

setting value is 10000, when the Accumulated Power Consumption of Relay1 over 

 

this value, GPB-7000 will send KWH meter report to warn the Group1 node,

 

minimum value is 1KWh and default value is 10000 kWh.

 

3-7 Watt differential report mode:

 

  Whenever the instant power consumption varies over 5%, it will report its instant 

power consumption to Group1 node. If the setting value is 0, it will disable sending 

the report.

 

 

4. Firmware update over the air (OTA)

 

GPB-7000 is based on 500 series SoC and supports Firmware Update Command 

Class, it can receives the updated firmware image sent by controller via the Z-wave 

RF media. It is a helpful and convenient way to improve some function if needed.

 

 

5. Command Classes

 

The Switch supports Command Classes including

 

* COMMAND_CLASS_ZWAVEPLUS_INFO

 

* COMMAND_CLASS_VERSION

 

* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

 

* COMMAND_CLASS_SECURITY0

 

* COMMAND_CLASS_SECURITY2

 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY

 

* COMMAND_CLASS_ASSOCIATION_V2

 

* COMMAND_CLASS_ASSOCIATION_GRP_INFO

 

* COMMAND_CLASS_POWERLEVEL

 

* COMMAND_CLASS_SWITCH_BINARY

 

* COMMAND_CLASS_BASIC

 

* COMMAND_CLASS_METER_V3

 

* COMMAND_CLASS_CONFIGURATION 

 

* COMMAND_CLASS_ALARM

 

* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

 

 
 
 
 
 
 
 

 


background image

 

 

Troubleshooting

                                 

 

Symptom

 

Cause of Failure

 

Recommendation

 

The switch does not 
work and the LED is off

 

1.

 

The Switch is not 
plugged into the 
electrical outlet 
properly

 

2.

 

The Switch break 
down

 

1. 

Check power connections

 

2. Dont open up the Switch and 

send it for repair.

 

The LED illuminates, but 
cannot turn ON or OFF 
the

 

switch

 

1. Check if the load 

plugged into the 
Switch has its own 
ON/OFF switch

 

2. Not carry out 

association

 

3. Same frequency 

interference

 

1. Set the ON/OFF switch of the load 

attached to ON

 

2. Carry out association

 

3.Wait for a while to re-try

 

LED keep flashing, but 
cannot control

 

Overload occurs

 

Remove the load attached or check 
max. load cannot exceed 16.0A

 

 

Specification

 

Operating Voltage

 

100-240VAC 50/60Hz 16A

 

Rated Voltage 

 

220-240Vac 50Hz (EU), 120Vac 60Hz (US), 230Vac 50Hz (IL), 

 

100Vac 50/60Hz (JP)

 

Maximum Load

 

16A (Resistive Load)

 

Range

 

Minimum 40M in door and 100M in outdoor line of sight

 

Operating Temperature

 

0簞C ~ 40簞C (85% humidity)

 

Storage Temperature 

-20 C ~ 60簞C

 

Location 

 

Indoor use only

 

Frequency Range

 

868.40MHz; 869.85MHz(EU) 

 

908.40MHz; 916.00MHz(USA/Canada)

 

916MHz (Israel)

 

 

 

** Specifications are subject to change and improvement without notice.                           

 

FCC ID :

 

2AQO4GPB-7000

 

 

 

Warning:

 

1.Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating

 

 

Choosing a Suitable Location

 

 

1. 

Do not locate the switch facing direct sunlight, humid or dusty place.

 

2. 

The suitable ambient temperature for the Switch is 0簞C~40簞C.

 

3. 

Do not locate the Switch where exists combustible substances or any source of 

heat, e.g. fires, radiators, switch etc.

 

4. 

After putting it into use, the body of switch will become a little bit hot of which 

phenomenon is normal.

 

 
 

 

DANGER

   

Danger of electrocution!

 

All works on the device may be performed only by a qualified and licensed 

electrician. Observe national regulations. 

 

Any works introducing changes into the configuration must be always performed with 

disconnected voltage. 

 

 
 
 
 
 

 


background image

 

Disposal   

 

This marking indicates that this product should not be disposed with other 
household wastes throughout the EU. To prevent possible harm to the 
environment or human health from uncontrolled waste disposal, recycle it 
responsibly to promote the sustainable reuse of material resources. To return 
your used device, please use the return and collection systems or contact the 
retailer where the product was purchased. They can take this product for 
environmental safe recycling

 

 

FCC Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules.   

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation.   

This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio 

communications.   

However, there is no guarantee that interference will not occur in a particular installation.   

If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one of the following measures: 

 Reorient or relocate the receiving antenna. 

 Increase the separation between the equipment and receiver. 

 Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

 Consult the dealer or an experienced radio/TV technician for help. 

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) This device must accept any interference received, including interference that may cause 

undesired operation. 

FCC Caution: Any changes or modifications not expressly approved by the party responsible 

for compliance could void the user's authority to operate this equipment. 

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter.