PDF User Manual

  1. Home
  2. Manuals
  3. Geomatics GLOG V2 Quick Manual

Geomatics GLOG V2 Quick Manual

Made by: Geomatics
Type: Quick Guide
Category: Data Loggers
Pages: 16
Size: 1.39 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

GLOG V2 

Portable RS232 Serial Data Logger 

 

Quick Guide 

  

(c) 2015 - Geomatics USA, LLC

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

GLOG V2

 

is a battery-powered compact device that logs data from RS232 

serial devices. It records the logged bytes (in its original form) on a removable 
storage medium.

 

 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

2” 

2” 

1” 

 

 

 

 

 

 

 

 

 

 

GLOG V2 Dongle 

GLOG V2 Key Features 

1.

 

Small (2” x 2” x 1”) and light weight (< 100 gm) 

2.

 

Battery operated - internal battery lasts over 20 

hours 

3.

 

Extremely easy to operate; just connect GLOG to the 

serial device via cable and hit the button; when 

done, remove the memory card and download the 

data to the PC 

4.

 

Streams serial data conveniently on to removable 

storage medium 

5.

 

Adds more memory on the go to a serial device—up 

to 16 GB 

6.

 

Uses inexpensive and reliable removable storage 

medium 

7.

 

Adds a backup data recording means to a serial 

device for extra robustness 

8. Logs Garmin raw satellite ranges for better 

navigational accuracy 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

POWER  

LED

 

 

 

RECORD / ANNUNCIATION     

LED

 

 

 

 

 

Red indicator inside a circle 

solid red for power ON 

POWER Button 

 

Turn power on and off

 

Blue indicator inside a square 

blue blinks for annunciations and 

memory/card activities

 

Green indicator inside a triangle 

green blinks for outgoing requests

 

Orange indicator inside a triangle 

orange blinks for incoming bytes

 

 

 

 

 

 

 

DATA OUT  

LED

 

 

 

DATA IN  

LED

 

 

GLOG V2 User Interface

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

GLOG V2 Data and Battery Charging Interfaces 

 
 

 

 

 

 

 

 

 

 

 

NOTES: 

 

-

 

Use 5V USB power supply to charge the battery – full charge takes two to four hours

 

-

 

Max. charging input current 500 mA 

-

 

The USB* port is also used to update the firmware (see GLOG V2 firmware update)

 

 

Continuous groups of five slow 
blinks every 10 seconds on the 

annunciation (Blue) LED indicate 
battery voltage lower than 3.5V 

 

USB* Battery Charging Port 

DB9 Port for RS232 Serial 

Data 

Input

 

Memory Card Slot for 

Data 

Output

 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

GLOG V2 Care

 

-

 

Keep away from direct sun or rain; device is not water proof

 

-

 

Always use caution when connecting external peripherals

 

-

 

Do not connect the USB and the DB9 simultaneously

 

-

 

Do not over charge or over discharge the battery

 

-

 

Do not use input current over 500 mA

 

-

 

Do not use unit when the battery voltage drops under 3.5V; continuous groups of five slow blinks every 

10 seconds on the annunciation (Blue) LED indicate battery voltage lower than 3.5V 

 

-

 

Charge the unit battery via its USB port either by plugging the cable to into the provided AC adapter or to 
a portable USB battery 

-

 

Battery Performance (see chart)

 

 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

Logging Garmin Data 

PREPARATION:

 

 

- Garmin receiver logging operate at 9600 baud 
- Receiver interface has to be set to ‘Garmin’ under the receiver ‘system’ sub-menu 
- Do not log data before the receiver has already acquired at least 4 satellites and is in ‘navigation’ mode 

Turn the Garmin receiver ON first

 and wait until a valid 3D position is available 

 

PROCEDURES: 

1.

 

Snap a fresh memory card into the GLOG memory card slot for data recording 

2.

 

Connect the Garmin receiver to GLOG via the Garmin-provided cable  

3. Switch GLOG ON by pushing the power button down; the round red LED should shine 
 

ANNUNCIATIONS:

 

 

- 20 rapid flashes on the square blue status LED: “Hello World from GLOG”  
-  Few  flickers  on  the  green  LED  followed  by  few  flickers  on  the  orange  LED,  then  10  rapid  flashes  on  the  blue  LED:  GLOG 

interrogating the serial device to see if it is a Garmin receiver 

-  More  flickers  on  the  green  LED  followed  by  flickers  on  the  orange  LED,  then  10  rapid  blue  flashes:  GLOG  requesting 

information/logs from the receiver 

- Long flickers on the orange LED followed by three groups of 10 rapid blue flashes: Garmin receiver acknowledges raw log 

requests; GLOG is ready to log raw data 

 
LOGGING:

  

- Once the receiver acknowledges raw data requests, GLOG enters into logging mode 
- Both the orange and the blue LEDs flicker continuously and irregularly to indicate data reception and disk activities 
- When done logging, switch the GLOG unit off and remove the memory card to download the data onto your PC!  

NOTE: Logged data is stored in chronologically numbered files!

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

Garmin Raw Data to Rinex Conversion 

Gar2Rnx:

 Console application to convert acquired GLOG raw Garmin satellite ranges 

into the Rinex format 

  

 

PREPARATION: 

- Copy Gar2Rnx.exe to a folder on your PC 
- Switch to the command (DOS) prompt as shown in the opposite picture  
- Change directory to where gar2rnx.exe resides 
NOTE: it is recommended that the ‘.GAR’ data file(s) reside in the same folder as the conversion utility, but it is not necessary 
 

 

PROCEDURES: 

- On the command prompt, type in the command 
 
   > gar2rnx <GAR File path>       then hit ENTER 
where:  

<GAR File path> is the full path to the acquired binary data file 

  

-

 

Gar2Rnx creates the RINEX observation file (.OBS) in the same <GAR File path> folder  

 

NOTE: Gar2Rnx utility generates satellite navigation information (.NAV) file in RINEX format if it is recorded.  Nevertheless, the NAV information is receiver independent 

and can be independently downloaded from several online services such as 

http://geodesy.noaa.gov/CORS/standard1.shtml

 

 

  

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

Logging non-Garmin Data 

 

PREPARATION: 

- Non-Garmin devices operate by default at 9600 baud, but this can change! 
- Make sure to use the right cable for the logging operation; logging from a computer requires null modem interface 

Turn GLOG ON first 

and wait until you see long flickers on the GLOG orange LED followed by three groups of 10 rapid blue 

flashes: GLOG enters logging mode 

- Set the serial device to send data at 9600 baud 

 

ANNUNCIATIONS:

 

 

-

 

After GLOG enters logging mode, the annunciation LED stops flashing 

 

PROCEDURES: 

1.

 

Snap a fresh memory card into the GLOG memory card slot for data recording 

2.

 

Connect the serial device to GLOG via proper serial cable  

 

LOGGING:

  

- Once the serial device and GLOG are connected via serial cable, both the orange and the blue LEDs flicker continuously and 

irregularly to indicate data reception and disk activities 

- When done logging, switch the GLOG unit off and remove the memory card to download the data onto your PC!  

 

NOTE:  

-

 

Use NULL MODEM connector/adapter when logging data from a computer 

-

 

Logged data is stored in chronologically numbered files! 

 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

Logging Generic Data 

GLOG logs serial data at baud rates other than 9600 

 
PREPARATION: 

- Create a “CONFIG.TXT” text file on the root folder of the memory card; use a text editor, e.g. notepad 
- specify four values separated by comma as follows: 
 

 

<devID>, <baud rate>, <PREFIX>, <SUFFIX> 

e.g.   0,57600,ABC,DAT   then hit ENTER and save the file to the disk 
devID  - 0:Generic, 1:Garmin (.GAR), 2:NovAtel (.GPS), 3:Hemisphere (.BIN), … 

PROCEDURES: 

1.

 

Snap the memory card into the GLOG memory card slot for 

configuration

 and data recording 

2.

 

Connect the serial device to GLOG via proper serial cable  

 

ANNUNCIATIONS:

 

 

-

 

10 rapid flashes on the square blue status LED: “Hello World from GLOG” 

-

 

10 rapid blue flashes to indicate “config.txt” file found 

-

 

Long flickers on the Rx orange LED followed by three groups of 10 rapid blue flashes: GLOG is ready to log data 

 

LOGGING:

  

- Both the orange and the blue LEDs flicker continuously and irregularly to indicate data reception and card activities 
- When done logging, switch the GLOG unit off and remove the memory card to download data to PC  

NOTES: 

-

 

Long orange flickers without blue flickers are indications that the serial device and GLOG are out of synch because of wrong baud rate! 

-

 

Use NULL MODEM connector/adapter when logging data from a computer 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

GLOG V2 Firmware Update 

 

Xloader:

 Windows application to update GLOG V2 firmware

 

 

PREPARATION:

 

 

- Download and install FTDI USB VCP driver from 

http://www.ftdichip.com/Drivers/VCP.htm

 

-

 

Download the latest version of the GLOG firmware (hex file) from 

http://www.geomatics.us/products/glog/

 

 

PROCEDURES: 

Switch ON GLOG first*

 

- Connect GLOG to the computer via a USB cable; Windows will recognize GLOG and assigns it a 

COM port number (COM14 in the example) – make sure nothing is connected to the DB9 port 

- Run Xloader 
- Browse to the location of the ‘hex’ file and choose it 
- Choose “Uno(ATmega328)” from the ‘Device’ pull-down menu; the baud rate will be automatically populated with 115200 
- Under the ‘COM port’ pull-down menu, choose the Windows assigned COM port number  
- Click upload; a confirmation message shows up in the status bar after about 30 seconds*    
 

NOTES:  

-

 

Attempting to attach GLOG to the computer while it is switched OFF will result in a “Device Not Recognized” error!

 

-

 

If 60 seconds or more have elapsed without getting a confirmation message, detach and reattach GLOG and try again! 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

USB Driver Issue 

A workaround for a known issue of the FT232RL chip driver

 

 

 

SYMPTOMS: 

Windows does not recognize GLOG V2!  It may display “USB device not recognized”.  Or, 

the serial port shows up in Windows ‘Device Manager’ with exclamation mark to indicate 

a problem! 

 

SOLUTION: 

1.

 

Revert back to FTDI version 2.10.0.0 driver or older 
Or 

2.

 

Manually install the serial port and/or the serial bus.

 

 

PROCEDURES:

  

1.

 

If not already plugged, plug in GLOG V2 and open device manager under My Computer 

2.

 

Right  click  the  ‘USB  Serial  Port’  and  click  ‘Update  Driver  Software…’  from  the  speed 

menu 

3.

 

Choose "Browse my computer for driver software" 

4.

 

Click "let me pick from a list on my computer" 

5.

 

Click "have disk" 

6.

 

Browse to the installed FTDI drivers folder and select an .INF file (port/bus) 

7.

 

Install the driver for the serial converter 

8.

 

Repeat for the USB serial port device, if necessary 

NOTE: It is sometimes sufficient to install either the port or the bus! 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 
 

GLOG V2 Real-Time Clock (RTC) Reset 

 

TIME.TXT:

 A text file containing the correct date and time

 

 

PREPARATION:

 

 

- use a PC text editor to create a text file; name it TIME.TXT 

 

 

-

 

type the correct date and time in the first line of the file as follows 

YYYY/MM/DD HH:MM:SS 
e.g. 2015/05/02 03/10/00 

-

 

save the file with the correct date and time to the SD card 
  

PROCEDURES: 

- insert the card with the TIME.TXT file into GLOG V2SD card slot 
- power the unit ON and wait about 10 seconds 
- power the unit OFF then remove the SD card 
- on a PC, delete the TIME.TXT off the SD card (or just change its name to something else)  
- The RTC now is reinitialized with the new date and time and should report the correct date and time 
 

NOTE: The SD card containing TIME.TXT may contain other files 

 
 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 
NOTES 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 
 

NOTES 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

GLOG V2 Quick Guide

  

 

 

 

 

 

 

 

 

 

 

 

 

 

16