GV- RK1352 Card Reader 

The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, 
identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be 
connected to any standard access control panel. GV-RK1352 comes with a weather sealed 
and IP66 compliant housing for outdoor use.  

 

1.  Packing List 

 

1. 

GV-RK1352 Card Reader x 1 

2. 

Screw x 2 

3. 

Screw Anchor x 2 

4. 

GV-RK1352 Software CD x 1 

5. 

GV-RK1352 Installation Guide x 1 

6. 

Front Cover Plate x 2 

 

Front View 

 

2.  Electric Wire 

Wire Color  

Function 

Red 

DC 7.5 ~ 12 V 

Black GND 
Yellow Beeper 
Orange Green 

LED 

Light Red 

Red LED 

Green 

Wiegand Data 0 

White 

Wiegand Data 1 

Blue RS-485 

Light Blue 

RS-485 - 

 

 

Rear View

 

 
 

 


background image

 

 

September 23, 2010 

 

2

3.  Keypad 

When accessing an entry, you can enter the door’s PIN code on the keypad or present the 
card and then enter the card’s PIN code on the keypad to be granted access. The access 
mode is defined on GV-ASManager. 
 

1. 

0~9 Number Keys:

 Press the number keys to enter the PIN code. 

2. 

# Key:

 Press the # key to confirm the PIN code. 

3. 

Key:

 Press the 

key to cancel the PIN code. 

 

4.  LED Indicator and Beeper 

In standby mode, the LED is blue. When a card is read, the LED flashes green and the 
beeper beeps once.  
 
GV-RK1352 comes with the external control wires of Green LED, Red LED and Beeper. 
When these control wires are connected to GV-AS Controller, the status of LED and Beeper 
can be defined by GV-AS Controller. For details on how to configure the settings, refer to 

6.Configuring the Beeper and LED Indicator

 later in this installation guide. 

 

5.  Connecting GV-RK1352 to GV-AS Controller 

The connection between GV-RK1352 and GV-AS Controller varies with different controller 
models. The following diagrams illustrate 

how to connect GV-RK1352 to GV-AS400 

Controller

 through Wiegand or RS-485 interface.  

 

Note: 

GV-RK1352 is compatible with GV-AS100/200/400 Controllers. However, to enable 

the keypad function, you can only connect GV-RK1352 to GV-AS100/200 Controllers 
through the Wiegand interface. For GV-AS400 Controller, the connection through either 
Wiegand or RS-485 interface is workable for the keypad function. 

 

 


background image

 

September 23, 2010 

 

3

5.1  Connecting through Wiegand Interface 

Up to eight GV-RK1352 readers can be connected to GV-AS400 Controller through the 
controller’s Wiegand interface.  
 

 

 

 

 

Wire Color Function 

Black GND 
Green 

Wiegand Data 0 

White 

Wiegand Data 1 

Red 

DC 12 V 

 

5.2  Connecting through RS-485 Interface 

Up to eight GV-RK1352 readers can be connected together to the RS-485 interface on GV-
AS400 Controller. When multiple readers are connected to the same RS-485 interface, you 
need to specify each reader an ID so that the controller can distinguish one reader from 
another. You will need to: 

1.  Connect GV-RK1352 readers to a computer to access the 

GV-RK1352 Config AP

2.  Define the ID number of each GV-RK1352 reader on the 

GV-RK1352 Config AP

.  

3.  Wire GV-RK1352 readers to GV-AS Controller. 

 

Note:

 If only one GV-RK1352 reader is connected to GV-AS Controller through RS-485 

interface, you can skip steps 1 and 2, and the default ID number for the reader will be 0. 

 

5.2.1  Connecting GV-RK1352 to a Computer to Access GV-RK1352 Config AP 

Using the 

GV-RK1352 Config AP

 included in the software CD, you can define the ID 

numbers of multiple readers connected through RS-485 interface.  
 

 


background image

 

 

September 23, 2010 

 

4

To start the 

GV-RK1352 Config AP

, you have to connect GV-RK1352 to a computer through 

GV-COM, GV-Hub or GV-NET/IO Card V3.1. 
 

 

 

Wire Color Function 

Blue RS-485 

Light Blue 

RS-485 - 

 

Note: 

GV-RK1352 is not compatible with GV-NET Card and  GV-NET/IO Card of versions 

earlier than V3. 

 

5.2.2  Defining ID Numbers of Readers 

After GV-RK1352 readers are connected to a computer, follow the steps below to define the 
ID number of each GV-RK1352 reader: 
 

1.  Insert the software CD and the Install Program window will pop up automatically. 

2. Select

 Install GeoVision USB Devices Driver

3.  In the GeoVision USB Driver Installer window that appears, select 

Install

.  

4.  Go back to the Install Program window, and select 

Run GV-RK1352 Config Utility

. This 

dialog box appears. 

      

 

 


background image

 

September 23, 2010 

 

5

5.  Type the barcode number of GV-RK1352 in the Serial ID box. The barcode number is on 

the rear panel of GV-RK1352. 

 

6.  Select the COM port that is connected to GV-RK1352 and click 

Open COM

. The red 

square next to the COM port box should change to blue to indicate the COM port is 
correct.  

Note:  

If the COM port is incorrect, an “

Error opening serial port

 

message will appear. 

To verify the COM port that is connected to GV-RK1352, go to Windows Device Manager. 
In the Ports (COM & LPT) field, you should see the entry for 

Prolific USB-to-Serial Comm 

Port

. The COM port showing in the entry indicates the COM number currently in use. 

         

 

 

7. Click 

Setup GO

. The settings are sent to GV-RK1352. 

 

Note: 

If you select the wrong COM port of GV-RK1352, a “

Fail. Please check Serial ID 

and comport

” message will appear when you click the 

Setup GO

 button. Go to Windows 

Device Manager to find out the COM port of GV-RK1352.  

 
 

 


background image

 

 

September 23, 2010 

 

6

5.2.3  Wiring GV-RK1352 to GV-AS Controller 

After defining the ID number of the readers, you can connect the wires of GV-RK1352 to GV-
AS Controller. Here we use 

GV-AS400 Controller

 as example to illustrate the wiring. 

z

 

Connecting four or less readers to GV-AS400 Controller:  

 

Wire Color   Function 

Black GND 
Light Blue 

RS-485 - 

Blue RS-485 

Red 

DC 12 V 

 

z

 

Connecting five or more readers to GV-AS400 Controller:  

For readers five to eight, connect the RS-485 cable to the RS-485 interface on GV-
AS400 Controller and then connect the 12V power output and GND of the reader to a 
10V to 13V DC power output on the GV-AS Power Board.   

 

Wire Color   Function 

Black GND 
Light Blue 

RS-485 - 

Blue RS-485 

Red 

DC 12 V 

 


background image

 

September 23, 2010 

 

7

 

6.  Defining Readers on GV-AS Controller Web Interface 

To define readers on the Web interface of GV-AS Controller, we use 

GV-AS400 Controller 

as example. Since GV-AS400 Controller can control up to four doors, you need to specify 
which door each reader controls. 
 

1.  On the GV-AS400 Web interface, click 

Extend Reader

. This dialog box appears. 

      

 

2.  Select the ID number of the reader and type its barcode number. The ID number should 

be the same with the one you configure through the 

GV-RK1352 Config AP

3.  Select a door/gate for the reader from the Function drop-down list. Click 

Submit

 

 

 


background image

 

 

September 23, 2010 

 

8

7.  Configuring the Beeper and LED Indicator 

You can configure the settings of the LED and the beeper by enabling the GV-AS Controller 
to externally control the LED and Beeper. You will have to: 

1.  Set up the Beeper and LED settings of the reader by using the 

GV-RK1352 Config AP

.  

2.  Wire the Beeper, Red LED and Green LED from GV-RK1352 to GV-AS Controller.  

3.  Specify the Beeper and LED settings for each door through the Web interface of GV-AS 

Controller. 

 

 

7.1  Setting up Beeper and LED on GV-RK1352 Config AP 

To enable the external controls of the Beeper and LED, start the 

GV-RK1352 Config AP

 

according to the instructions in 

Accessing the GV-RK1352 Config AP

 earlier in this 

installation guide. 
 
After 

GV-RK1352 Config AP

 is started, you have to enable the external controls and set the 

GV-RK1352 to be slave.  
 

1. Start the 

GV-RK1352 Config AP

. Type the barcode number and the COM port of GV-

RK1352. The barcode number is on the rear panel of GV-RK1352. Refer to 

Defining ID 

Numbers of Readers

 earlier in this installation guide on how to determine the COM port 

of GV-RK1352. 

      

 

 


background image

 

September 23, 2010 

 

9

2.  To enable external control of Beeper or LED, select 

Beeper

Green LED

 or 

Red LED

.  

„

 

Beeper:

 Enables the external control of Beeper. 

„

 

Green LED: 

Changes the standby color to green. 

„

 

Red LED:

 Changes the standby color to red. 

3. Select 

Slave

 from the Master / Slave drop-down list and select an ID number for the 

reader. The ID number is ranging from 0 to 7.  

4. Click 

Setup GO

. The settings are sent to GV-RK1352. 

 

After the above settings, you need to connect the Beeper, Red LED and Green LED wires 
from GV-RK1352 to GV-AS Controller 
 

7.2  Wiring the Beeper and LED to GV-AS Controller 

To wire the beeper and LED to GV-AS Controller, we use 

GV-AS400 Controller 

as example. 

Connect the control wires of GV-RK1352’s Beeper, Red LED or Green LED to any of outputs 
9 ~ 16 on GV-AS400 Controller. The following diagram is an example on connecting the 
beeper wire of GV-RK1352 to GV-AS400 Controller.  

 

 

 

Wire Color   Function 

Black GND 
Yellow  

Beeper 

 

 


background image

 

 

September 23, 2010 

 

10

7.3  Configuring the Beeper and LED Settings for Each Door/Gate 

After connecting the wires for Beeper or LED, specify the Beeper or LED settings for each 
door/gate on the GV-AS Web interface. Here we use 

GV-AS400 Controller 

as example.  

1.  On the GV-AS400 Web interface, click 

Output Setting

. The page below appears. 

2.  From the output 9~12, select a door and select 

Beeper

Green LED

Red LED

 or 

Invert 

Red LED

. Click 

Submit

      

 

       

„

 

Beeper: 

Enables the external control of Beeper. 

„

 

Green LED: 

Changes the standby color to green.

 

When a card is read, the LED 

flashes green. 

„

 

RED LED: 

Changes the standby color to red. When a card is granted access, the 

LED flashes green. When a card is failed to be granted access, the LED turns off for 
a very short time and then turns Red. 

„

 

Invert Red LED: 

Changes the standby color to no light. When a card is granted 

access, the LED flashes green. When a card is failed to be granted access, the LED 
flashes red. 

 

 


background image

 

September 23, 2010 

 

11

8.  Firmware Upgrade 

GeoVision will periodically release the updated firmware on the website. The new firmware 
can be simply loaded into GV-RK1352 by using 

Upload Application

 

included in the 

Software CD. 
 

Important Notes before You Start  

Before you start updating the firmware, please read these important notes:  

1.  While the firmware is being updated, the power supply must not be interrupted. 

2.  Do not turn the power off within 10 minutes after the firmware is updated.   

 

WARNING:

 The interruption of power supply during updating causes not only update 

failures but also damages to the device. In this case, please contact your sales 
representative and send your device back to GeoVision for repair. 

 
To upgrade firmware: 

1.  Insert the Software CD, select 

Upload Application

, and

 

follow the onscreen instructions 

to install the program. 

2. Double-click the 

Upload Application 

icon created on your desktop. This dialog box 

appears. 

      

 

3.  Select the COM port of GV-RK1352. 

4. Click the 

Browse 

button to locate the firmware file (.img) saved at your local computer. 

5. Click 

Update

6.  The LED indicator should flash purple during the process of firmware upgrading. When 

the process is complete, GV-RK1352 will be sounded twice and the LED indicator will 
change to green. 

          

 

 

 


background image

 

 

September 23, 2010 

 

12

9.  Specifications  

CPU 

8 bit microprocessor 

Frequency 

13.56 MHz for ISO14443A 

Wiegand Interface 

Wiegand 26 bit, distance 30 m / 98.43 ft 

RS-485 

9,600 bps, connect up to 8 GV-RK1352 units 

Power 

DC 7.5 V ~ 12 V 

LED 

Red, Green and Blue LED 

Beeper 

Buzzer 

Reader Color 

Black 

Operating Temperature 

-20 °C ~ 60 °C / -4 °F ~ 140 °F 

Operating Humidity  

10% ~ 90% (no condensation) 

Dimensions (W x H x D) 

95 x 108 x 23 mm / 3.74 x 4.25 x 0.91 in  

Weight 

260 g / 0.57 lb 

Certification 

IP66, CE, FCC 

 

10.  The number of GV-RK1352 supported by GV-AS 

Controllers  

GV-RK1352 Interface 

GV-AS Controller Model 

Wiegand 

RS-485 

GV-AS100

 

1

 

Not support 

GV-AS100 with GV-ASBOX

 

2

 

4

 

GV-AS200

 

4

 

8

 

GV-AS400

 

8

 

8