GV- DFR1352 Card Reader 

The GV-DFR1352 is a card reader designed to recognize identification cards. Featured with 
the Wiegand and RS-485 outputs, the unit can be connected to any standard access control 
panel. GV-DFR1352 comes with a weather sealed and IP66 compliant housing for outdoor 
use.  

 

1.  Packing List 

 

 

1. 

GV-DFR1352 Card Reader 

2. 

Screw x 2 

3. 

Screw Anchor x 2 

4. 

Front Cover Plate x 2 

5. 

GV-DFR1352 Software CD 

 

Front View 

 

2.  Installation 

Install the GV-DFR1352 to the door frame using the supplied screws and screw anchors. 
Before placing and sticking the front cover plate to the GV-DFR1352, remove the Plastic 
Cover to prevent scratches to the cover after installed.  

 

April 24, 2014 

 

1

 


background image

 

 

3.  Electric Wire 

 

 

Wire Color 

Function 

Red DC 

12V 

Black GND 
Yellow Beeper 
Orange Green 

LED 

Light Red 

Red LED 

Green 

Wiegand Data 0 

White 

Wiegand Data 1 

Blue RS-485 

Light Blue 

RS-485 - 

Gray N/A 
Purple N/A 
Brown N/A 

 

Rear View

 

 

4.  LED Indicator and Beeper 

In standby mode, the LED is blue. When a card is read, the LED flashes green and the 
beeper beeps once.  
 
GV-DFR1352 comes with external control wires for Green LED, Red LED and Beeper. You 
can connect these control wires to a GV-AS400 / 410 / 810 to allow the status of LED and 
Beeper to be defined by the GV-AS400 / 410 / 810. For details on how to configure the 
settings, refer to 

7. Enabling External Control of the Beeper and LED

 later in this installation 

guide. 
 

5.  Connecting GV-DFR1352 to GV-AS Controller 

GV-DFR1352 can be connected to GV-AS100 / 110 / 120 / 210 / 400 / 410 / 810. To see how 
many readers can be connected to a GV-AS Controller, refer to 

The number of GV-DFR1352 

supported by GV-AS Controllers

 table at the end of this installation guide. 

 
The connection between GV-DFR1352 and the controller varies with different controller 
models. The following diagrams illustrate 

how to connect GV-DFR1352 to GV-AS810 

Controller

 through Wiegand or RS-485 interface.  

April 24, 2014 

 

2

 

 


background image

 

5.1  Connecting through Wiegand Interface 

Up to eight GV-DFR1352 readers can be connected to GV-AS810 Controller through the 
controller’s Wiegand interface. 

Wire Color

 

Function

 

Black GND 
White  

Wiegand Data 1 

Green 

Wiegand Data 0 

 

Red DC 

12V 

 

5.2  Connecting through RS-485 Interface 

Up to eight GV-DFR1352 readers can be connected together to the RS-485 interface on GV-
AS810 Controller.  
 

 

Connecting four or less readers to GV-AS810 Controller:  

Wire Color

 

Function

Black GND 
Light Blue 

RS-485 -

Blue RS-485 

+

Red DC 

12V 

RS

485

   

 

 

April 24, 2014 

 

3

 

Connecting five or more readers to GV-AS810 Controller:  

For readers five to eight, connect the RS-485 cable to the RS-485 interface on GV-
AS810 and then connect the 12V power output and GND of the reader to a 12V power 
output on the controller.   

RS4

8

5

12

V

 O

U

TP

U

T

  

 


background image

 

 

5.2.1  Defining Readers on GV-AS Controller Web Interface  

Since multiple readers can connect to GV-AS Controller using one RS-485 interface, you 
need to specify which door each reader controls. This section explains how to define readers 
on the Web interface of GV-AS Controller using 

GV-AS210 Controller 

as an example.  

 

1.  On the GV-AS210 Web interface, click 

Extended Reader

. This dialog box appears. 

 

2.  In the GV-Reader/CR420/GF1921/GF1922 section, select the

 RS485

 checkbox in front of 

the ID number and type the 

Serial Number

 on the rear panel of the reader. The ID 

number will be assigned to the reader. 

 

3.  Select a door/gate for the reader from the

 Function 

drop-down list. Click 

Submit

 

April 24, 2014 

 

4

Note: 

When you click 

Submit

 on the Extended Reader page of a GV-AS210 / 410 / 810,

 

all GV-RK1352 / R1352 / DFR1352 connected through RS-485 interface will reboot. 

 


background image

 

6.  Overlaying Card Numbers on GV-System Live View 

You can overlay card numbers recognized at the GV-DFR1352 onto a camera channel on 
GV-System. To overlay card numbers on GV-System channel, the reader needs to be 
connected to a GV-System through GV-COM, GV-Hub or GV-NET/IO Card V3.1.

 

GV-DFR1352

RS-485

GV-HUB / GV-COM /

GV-NET/IO Card

RS-232

GV-System

(Light Blue)  RS-485 -

(Blue)          RS-485 +

USB

 

 

Note: 

GV-DFR1352 is not compatible with GV-NET Card and GV-NET/IO Card of versions 

earlier than V3. 

 

6.1  Defining the ID Number and Setting the Reader to Slave 

After the reader is connected to the computer of the GV-System, use the 

GV-Reader Config 

AP

 in the software CD to define the ID number of the reader and set the reader to Slave. 

 

1.  Insert the software CD. The Install Program window will pop up automatically.  

2. Select

 Install GeoVision USB Devices Driver

3.  In the GeoVision USB Driver Installer window that appears, select 

Install

.  

April 24, 2014 

 

5

4.  Go back to the Install Program window, and select 

Run GV-Reader Config Utility

.  

 

 


background image

 

 

5.  Select the COM port that is connected to GV-DFR1352 and click 

Open COM

. The serial 

number and firmware version of the reader will be automatically detected. The red square 
next to the COM port box should change to blue to indicate the COM port is correct. 

6. Under 

Master / Slave

, set the reader to

 Slave

7. Select an 

ID Number

 for the reader. The ID number ranges from 0 to 7.  

8. Click 

Setup

. The settings are sent to GV-DFR1352. 

 
If you want to connect multiple readers to the GV-System, you need to set up a unique ID 
number for each reader. For this you need to connect each reader to the computer one 
reader at a time, and follow the instructions above to set up an ID number. 

 

Note:  

1.  If the COM port is incorrect, an “

Error opening serial port

 

message will appear. To 

verify the COM port that is connected to GV-DFR1352, go to Windows Device 
Manager. In the Ports (COM & LPT) field, you should see the entry for 

Prolific USB-to-

Serial Comm Port

 and the COM number currently in use. 

 

2.  If you are using an older version of the GV-Reader Config AP, you will have to 

manually type the serial number of GV-DFR1352. The serial number is on the rear 
panel of GV-DFR1352. 

April 24, 2014 

 

6

 

 


background image

 

6.2  Adding the Reader to GV-System 

1.  In GV-System, click the 

Configure

 button, select 

Accessories

, and select 

GV Wiegand 

Capture Device Setting

. This dialog box appears. 

 

2. Click the 

New

 button. This dialog box appears. 

 

 

Type: 

Select GV-Wiegand Capture. 

 

Device:

 Type a number and name to help you identify the reader. 

 

COM: 

Select the COM port connected to the reader. 

 

Address:

 Select the ID of the connected reader you set in GV-Reader Config AP. 

 

Camera:

 Assign the reader to a channel to overlay card numbers on the live view. 

April 24, 2014 

 

7

3. Click the 

Add

 button.  

 


background image

 

 

7.  Enabling External Control the Beeper and LED 

You can change the default settings of the LED and the beeper by enabling a GV-AS400 / 
410 / 810 to externally control the LED and Beeper. The GV-AS Controller and the reader 
need to be connected through Wiegand interface. You will have to: 
 

1.  Enable external control of the GV-DFR1352’s Beeper and LED by using the 

GV-Reader 

Config AP

. Refer to

 7.1  Setting up Beeper and LED on GV-Reader Config AP

2.  Wire the Beeper, Red LED and Green LED from GV-DFR1352 to GV-AS400 / 410 / 810.  

3.  Specify the Beeper and LED settings for each door through the Web interface of GV-

AS400 / 410 / 810. 

 

 

7.1  Setting up Beeper and LED on GV-Reader Config AP 

To enable the external controls of the Beeper and LED on GV-Reader Config AP, the reader 
needs to be connected to a computer through GV-COM, GV-Hub or GV-NET/IO Card V3.1. 
 

 

 

1. Install 

GV-Reader Config AP

 from the Software CD. 

2. Start the 

GV-Reader Config AP

 and select the COM port that is connected to GV-

DFR1352.  

 

Note: 

To see how to install the GV-Reader Config AP and how to identify the COM port of 

the reader, refer to 

6.1 Defining the ID Number and Setting the Reader to Slave

 earlier in 

this installation guide

 

 

April 24, 2014 

 

8

 

 


background image

 

3. Click 

Open COM

. The serial number and the firmware version of the reader will be 

automatically detected.  

 

 

4.  To enable external control of Beeper or LED, select 

Beeper

Green LED

 or 

Red LED

.  

 

Beeper:

 Enables the external control of Beeper. 

 

Green LED: 

Changes the standby color from blue to green. 

 

Red LED:

 Changes the standby color from blue to red. 

5. Select 

Master

 from the Master / Slave drop-down list. 

6.  Select an ID number for the reader. Make sure the ID number on the GV-Reader Config 

AP matches the ID number set on the Extended Reader page of the GV-AS400 / 410 / 
810 Web interface. 

7. Click 

Setup

. The settings are sent to GV-DFR1352. 

 
If you want to set up multiple readers to be controlled by the controller, you need to connect 
each reader to the computer one reader at a time, and follow the above instructions to 
enable external control. 
 
After the above settings, connect the Beeper, Red LED and Green LED wires from GV-
DFR1352 to GV-AS400 / 410 / 810. 

April 24, 2014 

 

9

 

 


background image

 

 

7.2  Wiring the Beeper and LED to GV-AS400 / 410 / 810 

To wire the beeper and LED to GV-AS400 / 410 / 810, connect the control wires of GV-
DFR1352’s Beeper, Red LED or Green LED to any of outputs 9 ~ 16 on GV-AS Controller.  
 

Wiring LED to GV-AS Controller 

The diagram below shows the connection for wiring Green LED on GV-AS810. For Red LED, 
use the light red wire instead. 

 

 

Wire Color

 

Function

 

Black GND 
Orange Green 

LED

Light Red 

Red LED 

 

 

 

 

Wiring Beeper to GV-AS Controller 

The diagram below shows the connection for wiring the beeper on GV-AS810.

 

 

 

Wire Color

 

Function

 

Black GND 
Yellow  

Beeper 

 

 

 

 

 
After wiring, you also need to go to GV-ASManager to select the alarm conditions that will set 
off the reader’s beeper. In GV-ASManager, right-click the GV-AS Controller in the device list, 
click 

Settings

, and click the 

Door / Gate 

tab to select the alarm conditions. 

April 24, 2014 

 

10

 

 


background image

 

7.3  Configuring the Beeper and LED Settings for Each Door/Gate 

After connecting the wires for Beeper or LED, specify the Beeper or LED settings for each 
door/gate on the GV-AS400 / 410 / 810 Web interface.  
 

1.  On the controller Web interface, click 

Output Setting

. The page below appears. 

2.  From outputs 9~12, select a door and select 

Beeper

Green LED

Red LED

 or 

Invert 

Red LED

. Click 

Submit

 

 

 

Beeper: 

Enables the external control of Beeper. 

 

Green LED: 

Changes the standby color to blue.

 

When a card is read, the LED 

flashes green. 

 

RED LED: 

Changes the standby color to red. When a card is read, the LED flashes 

blue.  

 

Invert Red LED: 

Changes the standby color to blue. When a card is read, the LED 

flashes red.  

April 24, 2014 

 

11

 

 


background image

 

 

8.  Firmware Upgrade 

GeoVision will periodically release the updated firmware on the website. You can also find 
the latest firmware from the Firmware folder in the Software CD. The new firmware can be 
simply loaded into GV-DFR1352 by using 

Update Utility

 

included in the Software CD. 

 

Important Notes before You Start  

Before you start updating the firmware, please read these important notes:  

1.  While the firmware is being updated, the power supply must not be interrupted. 

2.  Do not turn the power off within 10 minutes after the firmware is updated.   

 

WARNING:

 The interruption of power supply during updating causes not only update 

failures but also damages to the device. In this case, please contact your sales 
representative and send your device back to GeoVision for repair. 

 
To upgrade firmware: 

1.  Insert the Software CD, and select

 Run Firmware Update Utility

. This dialog box 

appears. 

 

2.  Select the COM port of GV-DFR1352. 

3. Click the 

Browse 

button to locate the firmware file (.img) saved at your local computer. 

4. Click 

Update

April 24, 2014 

 

12

5.  The LED indicator should flash purple during the process of firmware upgrading. When 

the process is complete, GV-DFR1352 will be sounded twice and the LED indicator will 
change to green. 

 


background image

 

April 24, 2014 

 

13

9.  Specifications  

CPU 

8-bit microprocessor 

Frequency 

13.56 MHz for ISO14443A (Mifare DESFire, Mifare 
Plus and Mifare Class) 

Wiegand Interface 

Wiegand 26 / 34 bits, distance 30 m / 98.43 ft 

RS-485 

9,600 bps, connect up to 8 GV-DFR1352 units 

Power 

DC 7.5V – 12V 

LED 

Red, Green and Blue LED 

Beeper 

Buzzer 

Reader Color 

Black 

Operating Temperature 

-30 °C ~ 65 °C / -22 °F ~ 149 °F 

Operating Humidity  

10% ~ 90% (no condensation) 

Dimensions (W x H x D) 

20.9 x 105.6 x 20.5 mm / 0.8 x 4.2 x 0.8 in 

Weight 

80 g / 0.17 lb 

Ingress Protection 

IP66 

Certification 

CE, FCC, RoHS 

 

10.  The number of GV-DFR1352 supported by GV-AS 

Controllers  

GV-DFR1352 Interface 

GV-AS Controller Model 

Wiegand 

RS-485 

GV-AS100

 

1

 

GV-AS110 / 120 

Not supported 

GV-AS100 / 110 / 120 with GV-ASBox

 

2

 

4

 

GV-AS100 / 110 / 120 with GV-ASNet 

Not supported 

GV-AS210 4 

GV-AS400

 

8

 

8

 

GV-AS410 / 810