PDF User Manual

  1. Home
  2. Manuals
  3. GeoMax Zipp20 Series Installation Manual

GeoMax Zipp20 Series Installation Manual

Made by: GeoMax
Type: Installation Guide
Category: Measuring Instruments
Pages: 16
Size: 0.74 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Zipp20 TPS Series

- 1 -

Installation Guide

GeoMax TPS

Zipp20 Series

Installation Guide

Version: 1.0
English

 


background image

Zipp20 TPS Series

- 2 -

Installation Guide

Tablet of Contents

1

I

NTRODUCTION

.............................................................................. 3

2

P

REPARATION OF THE

TPS I

NSTRUMENT

........................................... 4

2.1 Battery Charging

......................................................................................... 4

2.2 Obtaining Firmware Files

............................................................................ 4

2.3 Uploading Onboard Firmware to the Instrument

..........................................5

3

U

PLOADING

G

EO

M

AX

F

IELD

G

ENIUS

.................................................. 6

3.1 Windows Mobile Device Center

................................................................... 6

3.2 Connecting to the PC

.................................................................................. 6

3.3 Installation of GeoMax FieldGenius

............................................................. 8

3.4 Registration of GeoMax FieldGenius

........................................................... 11

3.5 Starting GeoMax FieldGenius

..................................................................... 12

4

R

E

-, U

NINSTALL OR

U

PDATE

G

EO

M

AX

F

IELD

G

ENIUS

......................... 13

4.1 Re-Install/Update GeoMax FieldGenius

...................................................... 13

4.2 Uninstall GeoMax FieldGenius

.................................................................... 14

 


background image

Zipp20 TPS Series

- 3 -

Installation Guide

1 I

NTRODUCTION

This guide provides complete step-by-step instructions for preparing the Zipp20 total
station series for measuring work.

The latest versions of GeoMax documents and software referred to in this document
are  all  available  from  the  GeoMax Partner Area  in  the  Zipp20  folder  at

http://www.geomax-positioning.com/Partner-Area-Login_1186.htm

.

Only  the  tasks  required  for  the  initial  setup  are  described  in  this  document. The
instructions  cover  all  the  required  installation  tasks  for  the Zipp20  total  station  and
the GeoMax FieldGenius onboard software.

For  further  information  regarding the  operation  of  the  Zipp20,  please  refer  to  the
respective manuals.

The  Zipp20  Quick  Guide  is  included  with  the  container  set.  The  comprehensive  user
manual is available from the included USB stick and also from GeoMax Partner Area in
the Zipp20 folder at

www.geomax-positioning.com.

The GeoMax FieldGenius manual can be downloaded from the GeoMax Partner Area at

www.geomax-positioning.com

.

 


background image

Zipp20 TPS Series

- 4 -

Installation Guide

2 P

REPARATION OF THE

TPS I

NSTRUMENT

2.1 B

ATTERY

C

HARGING

Before  using  the  instrument,  the ZBA301  battery  should  be  charged.  Insert  the
battery  into  the  ZCH301  charger  and  plug  the  adapter  into  an  AC  supply.  Do  not
disconnect  from  power  until  the  green  FULL  indicator  flashes, indicating  that  the
battery  is  fully  charged.  Once  charged, insert  the  battery  into  the side  cover  slot  of
the Zipp20 instrument and switch on.

2.2 O

BTAINING

F

IRMWARE

F

ILES

When  receiving  a  new  instrument,  it  should  be  checked  that  the  latest  firmware
version  is  installed.  The  installed  version  can  be  seen  on  the  Software  Information
page,  accessed  by  starting  the

Zipp20  application

and  pressing

(3)-Tools /  (2)-

SysInfo  /  (FNC2)-Softw

.  If  the  displayed  firmware  version  does  not  match  the  one

available from GeoMax Partner Area, then the instrument should be updated.

To  customize  the  instrument  for personal requirements,  the  firmware  file  in  the
required  language  should  be  installed.  The  respective  files  can  be  obtained  from
GeoMax Partner  Area  in  the  Zipp20/Firmware  folder  and  are  in  the  format

Zipp20_XX.fw

where  “XX”  indicates  the  specific  language. The  firmware  files  also

contain all available applications.

 


background image

Zipp20 TPS Series

- 5 -

Installation Guide

2.3 U

PLOADING

O

NBOARD

F

IRMWARE TO THE

I

NSTRUMENT

The firmware file is uploaded to the instrument directly from the USB stick. Therefore
copy the downloaded file to the

System

directory on the USB stick using a PC. Insert

the stick into the instrument and power on. To load the file onto the instrument, start
the

Zipp20  application

and  choose

(3)-Tools /  (3)-Load  FW  /  (F1)-Firmware

. The

content of the System directory are now shown. Select the firmware file and choose
(

F1)-OK

to start the upload process.

Note:

Ensure that a fully charged battery is inserted when uploading firmware. This

process  can  take  some  time  and  the  power  supply  must  NOT  be  interrupted  during
the loading process.

Your Zipp20 instrument is now ready for use.

 


background image

Zipp20 TPS Series

- 6 -

Installation Guide

3 U

PLOADING

G

EO

M

AX

F

IELD

G

ENIUS

3.1 W

INDOWS

M

OBILE

D

EVICE

C

ENTER

An upload and installation of the GeoMax FieldGenius on the Zipp20 requires a PC or
Laptop. To upload  the  field  software  to the Zipp20,  it  is  mandatory  to  install  the

Windows Mobile Device Center

on the PC or Laptop.

Windows Mobile Device Center was written as a successor to the ActiveSync program
that was previously used to synchronize Windows CE based devices with Windows
operating systems prior to Windows Vista. If the operating system is not Win7, Win8
or Vista such as Windows XP or Windows 2000, you are required to install Microsoft
ActiveSync. Both applications are free of charge and can be downloaded from various
websites (e.g. Microsoft).

3.2 C

ONNECTING TO THE

PC

If using Win8, Win7 or Vista on your PC, the Windows Mobile Device Centre needs to
be  installed.  For  earlier  versions  of  Windows,  install  Microsoft  ActiveSync. After  the
software installation, open the

Windows Mobile Device Centre

and connect the Zipp20

to your PC. Use the USB cable supplied with the Zipp20 as shown below.

 


background image

Zipp20 TPS Series

- 7 -

Installation Guide

Turn  on  the  instrument  and  the  connection  will  be  established.  After  the  initial
connection, the

Windows Mobile  Device  Centre

or

ActiveSync

will  automatically  start

and connect as soon as the powered instrument is connected to the PC.

The  contents  of  the PS336 internal  memory  can also be  seen now with  Windows
Explorer and are defined as a drive named

Zipp20_SerialNumber

.

 


background image

Zipp20 TPS Series

- 8 -

Installation Guide

3.3 I

NSTALLATION OF

G

EO

M

AX

F

IELD

G

ENIUS

The  latest version of GeoMax  FieldGenius can be downloaded from the GeoMax
website,  at

http://www.geomax-positioning.com

. Here  the latest installation version

and user manual of GeoMax FieldGenius in English is available. Download the

Devices

Installer

and  save  onto  your  PC. On  this  page,  all  the  available  languages  for

FieldGenius  are  shown.  Click  on  the  required  language  and  save  the  installation  file
onto your PC.

With  the Zipp20 connected  to  your PC,  run  the installer  file

geomax-fieldgenius7-

onboard-7.1.11.2-enu.exe

. The  PC  will  attempt  to  connect  to  the  handheld  and

install the GeoMax FieldGenius software. Follow the Windows installation wizard.

At  the  Device  Selection  window select  the  data  collector

GeoMax  Zipp20  WinCE

onboard

.

 


background image

Zipp20 TPS Series

- 9 -

Installation Guide

Please  select

“No”

when  prompt  for  Default  Installation  Path and  then  choose

“Internal Memory”

of the Total Station to install the program.

When  the application  downloading is  completed,  you  are  requested  to  check  the
Zipp20 screen. Click OK and Finish to exit the installation process on your PC.

 


background image

Zipp20 TPS Series

- 10 -

Installation Guide

Confirm the proposed installation folder for GeoMax FieldGenius on the Zipp20 screen
by clicking OK. The installation on the Zipp20 will be started.

Once  the installation  process  is  completed, the GeoMax FieldGenius  software  can be
started by selecting it from the Zipp20 Desktop.

 


background image

Zipp20 TPS Series

- 11 -

Installation Guide

3.4 R

EGISTRATION OF

G

EO

M

AX

F

IELD

G

ENIUS

When GeoMax FieldGenius  is  started,  a  registration  window with  the  Device  ID is
displayed  as  shown  below. It  is  possible  to  use GeoMax FieldGenius without
registration  by  tapping

Run  Demo  Mode

.  This  provides  full  functionality,  but  is

limited to the storage of 30 points.

To  register  your  version  of GeoMax FieldGenius,  an activation key  needs  to  be
entered. The displayed Device ID, together with the GUID (global unique identity), is
used to obtain the key. The GUID can be found in the MicroSurvey envelope that was
supplied together with Zipp20 equipment.

The  activation  key  can  be generated  by  using MicroSurvey’s web  portal, at the  link

http://microsurveylicenseserver.com/ValidateSerialNumber.aspx

. This web  portal is

 


background image

Zipp20 TPS Series

- 12 -

Installation Guide

shown in the screenshot below. At the blank serial number field, enter your GUID and
click

Submit

. At the next screen, enter the Device ID shown on the Zipp20.

Note:

Make  certain  that  the  entered  Device  ID  is  correct  the  first  time,  since  an

activation key cannot be generated again with a different ID.

The activation key will then be displayed in the password field. Enter this key into the
Zipp20 at  the provided  fields  and  click

Apply  Key

.  More  details  about  the GeoMax

FieldGenius  installation  and  registration  can  be  found  in the user  manual available
from the GeoMax Partner Area.

3.5 S

TARTING

G

EO

M

AX

F

IELD

G

ENIUS

The first screen displayed when starting GeoMax FieldGenius is the Project Manager.
Create a new project by tapping the appropriate icon and enter a project name. The
onscreen  keyboard  can  always  be  accessed  by  double  tapping on  the  editable  field.
The screens that follow are used to set the default settings for this project.

 


background image

Zipp20 TPS Series

- 13 -

Installation Guide

You  are  now  ready  to  work  with  the  Zipp20  total  station  and  GeoMax  FieldGenius.
More  details  about  the  use  of  GeoMax FieldGenius can  be  found  in  the user manual
document available from the GeoMax Partner Area.

4 R

E

-, U

NINSTALL OR

U

PDATE

G

EO

M

AX

F

IELD

G

ENIUS

4.1 R

E

-I

NSTALL

/U

PDATE

G

EO

M

AX

F

IELD

G

ENIUS

Occasionally it  may  be  necessary  to update  or  reinstall  your  GeoMax FieldGenius
software. An  update  or  re-install  of  the  GeoMax FieldGenius software  follows  mainly
the  procedure  which  was described  in this  document  in chapter

3.3  Installation  of

GeoMax FieldGenius.

To start the update or re-install please refer to chapter 3.3.

After clicking

Install

,  the  installation  file  will detect the  current  installed  GeoMax

FieldGenius software.

 


background image

Zipp20 TPS Series

- 14 -

Installation Guide

Confirm  this  message  by  clicking

Yes

.  The  installation  will  be  continued  as  known

from the very first installation.

4.2

U

NINSTALL

G

EO

M

AX

F

IELD

G

ENIUS

To  uninstall

GeoMax  FieldGenius

from  the  Zipp20,  you need to  start  the  software  at

least  one  time  after the instrument has  been  turned  on.  Exit  GeoMax  FieldGenius
again and go to the Windows program “Remove Programs”.

 


background image

Zipp20 TPS Series

- 15 -

Installation Guide

Mark

GeoMax  FieldGenius

and  click

Remove

.  The  program  will  be  removed. A

message appears as further folder and files still need to be removed.

In  order  to  complete  the  uninstall  process,  the  following  folder  and  files  need  to  be
deleted manually. Please access the Windows Explorer with

My Device

.

 


background image

Zipp20 TPS Series

- 16 -

Installation Guide

The following folder and files needs to be deleted in the

Internal Memory

drive:

Internal Memory\GeoMax FieldGenius (remove complete folder)

GeoMax FieldGenius.lnk

in Internal Memory\Documents and settings\Programs

GeoMax FieldGenius.lnk

in Internal Memory\Documents and settings\Desktop