Full Text Searchable PDF User Manual

page 1
Genquip Gi3300 DSP Inverter Generator
Genquip Gi3300 DSP Inverter Generator
Owners Manual

page 2
Genquip Gi3300 DSP Inverter Generator

page 3
Genquip Gi3300 DSP Inverter Generator
Control Function
4
Pre Operation Checklist
5
• Fuel System
• Refueling & Fuel Level Gauge
• Engine Oil
Control Function Continued
6
• Oil Warning System
• Engine Switch
• DC Protector
Operation
7
Starting The Engine
Periodic Maintenance
8
Spark Plug Inspection &
Oil Replacement
9
Engine Oil Replacement
10
Fuel Filter
11
Fuel Tank Filter
11
Air Filter Maintainence
11
Valve Adjustment
12
Genquip Safety
13, 14, 15
Operating Procedure
16
• Visual Inspection
• Start Up
• Shutdown
Maintaining your Generator 17
• Cleaning
• Storing or Transporting
• Servicing
Specifications & Dimentions 18
Wiring Diagram
19
Troubleshooting
20, 21
• Engine Won’t Start
• Generator Won’t Produce Power
• Storage : Drain The Fuel
• Storage : Engine
Warranty
22
Notes
23
Table of Contents

page 4
Genquip Gi3300 DSP Inverter Generator
Control Function
Description and Control Panel Key
1. Carrying Handles
2. Fuel Level Gauge
3. Fuel Cap and Vent
4. Fuel On/Off Switch
5. AC Ready Pilot Light
6. Oil Warning Light
7. Ground (Earth) Terminal
8. 240 Volt Sockets
9. Engine On/Off Switch
10. Choke Knob
11. Recoil Starter
ON
C HO K E
DIGITA L
TECH
DC 12V 8A
O N OFF
(PUSH)
PRO T EC TO
R
ON
STO P
ECON
ON
OFF
A C
TO R ESET A C
RESTART EN G
INE
1
2
3
1
9
10
11
12
13
4
5
6
7
8

page 5
Genquip Gi3300 DSP Inverter Generator
Pre Operation Checklist
Note:
Pre-operation checks should be made each time the generator is used.
Fuel System
Make sure there is sufficient fuel in the tank. The engine must use regular unleaded
petrol only and the fuel tank capacity is 7 litres.
Refueling And Fuel Level Gauge
To refuel, remove cap and fuel slowly until fuel gauge indicates full. Apply fuel cap and
turn fuel vent to the ON position.
WARNING:
Fuel is high flammable and poisonous.
DO NOT fill above the top of fuel filler or it may
overflow when the fuel heats up and expands.
Wipe up any spilled fuel immediately.
After refueling, make sure the tank cap is tightened.
Engine Oil
Make sure the engine oil is at the upper level of the oil filler hole. Add oil as necessary.
Recommended oil for most climates is 10W30. Engine oil quantity is 600 millilitres.
Fuel Cap and Vent
Fuel Level Gauge
“F”
Full
“E”
Empty

page 6
Genquip Gi3300 DSP Inverter Generator
Control Function Continued
Oil Warning System
If the oil level falls below the safe operating level, the engine will stop automatically.
Unless you refill with oil, the engine will not start again.
Note:
If the engine stalls or does not start, turn the engine switch to “ON” position and
then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil
is low. Add oil and restart.
Engine Switch
The engine switch controls the ignition system.
A. Ignition circuit is switched on.
The engine can be started.
B. Ignition circuit is switched off.
The engine will not run.
DC Protector
The DC Protector turns of automatically when the loads exceeds the generator rated
output.
Note:
If the DC Protector trips to the OFF position, press to reset. Reduce the load to
the specified generator output if the DC protector turns off. If it turns off again, consult
the authorized dealer.
A
B
ON
STOP
ON
(PUSH)
PROTECTOR
OFF

page 7
Genquip Gi3300 DSP Inverter Generator
Operation
Starting The Engine
Note:
Before starting the engine, do not connect any electric devices.
1. Turn the fuel switch lever to the “ON” position.
2. Turn the engine switch to the “ON” position.
Note:
Sometimes the choke is required to start a warm engine.
3. Hold the choke knob fully out.
4. Pull slowly on the recoil starter until it is engaged, then pull it briskly.
5. After the engine starts, warm up the engine until the engine does not stop when the
choke knob is returned to the original position.
6. Push the choke knob back to the original position.
Note:
When starting in cold conditions (below 5˚C) run the engine with choke applied
for two to three minutes to warm up motor.
ON
OFF
A
B
ON
STOP
1.
2.
CHOKE
CHOKE
3.
6.

page 8
Genquip Gi3300 DSP Inverter Generator
Periodic
Maintenance
Spark Plug
1. Clean Adjust
2. Replace
1
2
Valve Clearance
Check Adjust
4
Engine Oil
1. Check
2. Replace
1
2*
2*
*
*
Air Cleaner
1. Check
2. Replace
1
1
2
Fuel Filter
Replace
4
Clean Spark
Arrester-Screen
4
Recoil Starter
Check operation
4
Choke Handle
Check operation
4
Fuel System
Check hose condition
look for leaks
4
4
Fittings Fasteners
Check and Tighten
4
4
Cooling System (Air)
Check for obstructions
4
4
Exhaust System
Check for obstructions
4
Item
* First 20 hours & then every 50 hours
Attention
1 Month or 20 hours
Pre-operation (Daily)
3 Months or 50 hours
6 Months or 100 hours
12 Months or 300 hours

page 9
Genquip Gi3300 DSP Inverter Generator
Spark Plug Inspection & Oil Replacement
You should periodically remove and inspect the spark plug.
1. Check for discoloration and remove the carbon.
2. Check the spark plug type and gap.
• Standard electrode color: Tan Color
• Standard Spark Plug: BPR4ES(NGK)(F7RTC)
• Gap: (0.028-0.031 inches)
3. Install the spark plug.
• Spark Plug Torque:14 lbs. -Ft.
(0.028-0.031 inch)

page 10
Genquip Gi3300 DSP Inverter Generator
Engine Oil Replacement
1. Place the machine on a level surface and warm up the engine. Then stop the
engine.
2. Remove the rubber cap on the bottom..
3. Place an oil pan under the engine. Remove the drain bolt
4. Open the oil filler cover as shown and remove the oil filler cap so that the oil can be
completely drained.
5. Check the drain bolt, gasket, oil filler gap and O-ring.
6. Reinstall the oil drain bolt.-Drain Bolt Torque:12 Ft. lbs.
7. Add engine oil to the upper level.
• Recommended oil for most climastes: 10W30
• Engine Oil Quantity: 600 millilitres
CAUTION:
Be sure no foreign material enters the crankcase.
8. Install the oil filler cap.
9. Install the rubber cap on the bottom.
CAUTION:
Be sure to install securely to prevent from falling off
during operation.
10. Close the oil filler cover.

page 11
Genquip Gi3300 DSP Inverter Generator
Fuel Filter
Do not smoke or have an open flame in the vicinity of the fuel and solvent.
1. Stop the engine:
2
Clamp the fuel line with the clip.
3
Replace the fuel filter.
Fuel Tank Filter
1. Remove the fuel tank cap and filter.
2. Clean the filter with solvent, if damaged, replace.
3. Wipe the filter and insert it.
WARNING:
Be sure the tank cap is securely tightened.
Air Filter Maintainence
1. Remove black side cover
(4 screws, opposite exhaust outlet side)
2. Unscrew bolts
3. Remove cover
4. Remove foam air filter
5. Clean filter in foam filter
cleaner and dry
6. Re-oil with filter oil
7. Squeeze out excess oil
Do not wring out
8. Reit to machine and reassemble.

page 12
Genquip Gi3300 DSP Inverter Generator
Valve Adjustment
Note:
Valve adjustment should only be
performed on a cool engine.
1. Remove back case, then take off valve
cover.
2. Pull the starter rope gently and set the
piston in top dead center (Use a stick
in the spark plug hole measure the
depth).
3. Insert a feeler gauge into the gap
between rocker and valve to measure
the valve clearance.
Valve Clearance
Intake:
0.1mm
(0.004 in)
Exhaust:
0.1mm
(0.004in)
4. If adjustment is necessary, proceed as
follows:
a. Hold rocker axis using the wrench and
loosen the lock nut.
b. Loosen the lock nut of rocker axis to
gain the specified intake and exhaust
valve clearance.
c. Hold rocker axis using a wrench and
tighten the lock nut.
d. Check the clearance of valve after
adjustment.

page 13
Genquip Gi3300 DSP Inverter Generator
Genquip Safety
“Genquip values your safety and the safety of others
when using your Genquip generator”
General safety
It is important to read and understand your owner’s manual before operating your
Genquip generator.
Safety tips for safe operation
• Know where the controls are and how they operate, for the startup and shut off
procedure.
• Know the location of the fuel shutoff and how it operates.
• Genquip generators must always be used in a well ventilated area.
• Your Genquip generator is not weatherproof.
• To prevent electrical shock, make sure your generator is properly grounded.
• Operate the generator on a level surface.
• Never refuel your Genquip generator whilst the engine is running.
• Always allow sufficient time for the generator to cool down before refueling.
• Always refuel the generator in a well-ventilated area.
• Keep all flammable materials and fuel away from the operating generator.
• Caution of the hot exhaust must be observed as a generator can easily start a fire;
always locates your generator where its exhaust will vent safely.
• Avoid getting burned. Many generator parts radiate heat that is sufficient to burn you
during operation.
• Only a licensed electrician should hard wire your Genquip generator.
• Turn off all equipment powered by the generator before shutting down your generator.
• Never over load your Genquip Generator, if unsure about the power requirements
consult a licensed electrician.
• Generators can be noisy, so when working around the generator it may be advisable
to wear appropriate ear protection.
• Keep children away from your Genquip generator at all times.
• Never permit anyone to operate a Genquip generator without proper instructions.
DANGER:
Only competent and qualified electricians should
connect wiring to this equipment; all connections
must comply with all applicable Australian Standards
and electrical codes.

page 14
Genquip Gi3300 DSP Inverter Generator
Activity/Procedure
If you do this ...
Potential Hazards
This could happen ...
Risk
Corrective Action
You can prevent by ...
Operating generator in
unventilated or enclosed
area.
Generator may over heat.
Carbon Monoxide (CO)
poisoning from the toxic
engine exhaust.
2
1
Operate generator in a
well-ventilated area. Do
not operate in an enclosed
location.
Operate the generator
in a careless/reckless
manner.
Unsafe operation could
lead to serious injUry to
you & others.
2
Review and understand all
the operating instructions
and warnings supplied by
manufacture
Refueling the generator
while engine IS running.
Petrol vapors are highly
flammable & could cause
a fire or explosion, which
can cause serious injury.
2
Always shut down engine
and allow engine to cool
sufficiently. Open fuel
cap slowly and have an
appropriate fire extinguisher
present.
Over filling with fuel
or fuel spillage while
refueling.
Fuel that is spilled whilst
refueling can cause fire
or explosion.
2
Open fuel cap slowly. Do
not over fill fuel tank. If
fuel spillage has occurred
during refueling, clean the
spillage completely and allow
sufficient time for any fuel
vapors to dissipate.
Tampering with the
factory preset engine
settings.
Generator could over heat
and engine could over
speed, which may result
in a fire causing injury.
2
Never attempt to tamper with
factory settings, if in doubt
contact Genquip.
Failure to use the
generator grounding point
and correctly ground the
generator.
Generator unit could
become electrically
charged and could cause
electrocution.
1
Make sure the generator
is connected /grounded
correctly.
Exceeding the load
capacity of the generator
by attaching to many
items, or items with very
high load ratings.
Could overheat some
items or their attached
wiring causing fire or
electrical shock.
1
2
Understand load ratings.
Make sure that the total
of electrical loads for all
attachments does not
exceed the load rating of the
generator. Refer to a licensed
electrician if in doubt.
Operating generator
with guards or protective
covers removed.
Exposed moving parts
and hot surfaces could
cause injury.
2
Never operate the generator
without the factory fitted
guards or protective covers.

page 15
Genquip Gi3300 DSP Inverter Generator
Activity/Procedure
If you do this ...
Potential Hazards
This could happen ...
Risk
Corrective Action
You can prevent by ...
Contact with hot
surfaces such as
engine, exhaust
components.
Could result in serious burns.
2
During operation, touch only
the control surfaces. Shutting
the generator down and
letting it cool sufficiently.
Keep children away from
generator during and
immediately after operation.
Operating generator
to close to buildings
or placing objects
close to the muffler
exhaust can cause.
Heat buildup that could
cause generator to overheat
and the possibility of fire.
Objects close to generator
may be damaged due to close
proximity.
2
Ensure that the generator
is sufficient distance from
buildings or objects allowing
heat and exhaust emissions
to dissipate freely.
Smoking around the
generator.
Fire. Explosion.
Serious Injury.
2
Do not smoke around
the generator under any
circumstances.
Operating whilst
wet or Cleaning the
generator when in
operation can cause.
Electrocutionasdfa
1
Never operate the generator
whilst wet or expose to
damp conditions. Clean the
generator only when shut
down and cooled down
completely. Do not spray
water directly on or near any
electrical items. Use a damp
cloth to Wipe over generator
to keep clean.
Operating generator
on an uneven surface
may cause.
Engine to seize and over heat
due to improper lubrication.
Fuel spillage, which may
cause fire or explosion
resulting in serious injury.
2
Always operate generator on a
level & hard surface.
Moving the generator
whilst in operation.
Fuel spillage, which may
cause fire or explosion
resulting in serious injury.
2
Always shut down generator
and allow it to cool completely
before moving.
Transporting
generator.
Fuel spillage, which may
cause fire or explosion
resulting in serious injury. Oil
spillage, which may cause
slippage.
2
Ensure fuel tap is switched
off and the fuel cap is affixed
firmly. Always transport
the generator in an upright
position. If transporting over a
long distance drain fuel from
tanks.
Using the incorrect
fuel &/or oil type.
Misfiring of engine, which
may result in engine parts
separating from main body
resulting in serious injury.
2
Ensure you check that you
are using correct oil and fuel
types.

page 16
Genquip Gi3300 DSP Inverter Generator
Genquip Operating Procedure
Visual Inspection
Carefully inspect the generator set before you first use it, look for the following
discrepancies:
• General appearance and cleanliness
• Loose or broken wires and defective connections
• No oil or fuel pooling around generator
• Check fuel filter
• Missing covers
• Oil level
• Fuel level
• Air filter is not dusted and is free of debris
• Generator grounded
• Fuel cap on
Start up
• Disconnect any electrical devices from the generator.
• Generator is on a level surface.
• Exhaust is free from obstructions.
• Fuel shut tap is on.
• Always use fresh fuel.
• Engine switch is in the on position.
• Choke is in the open position.
• Return choke to the closed position once running (petrol model only).
Shutdown
• Make sure all electrical devices, are disconnected from generator.
• Turn the fuel tap to the off position.
• Allow the generator to cool sufficiently before moving or storing.

page 17
Genquip Gi3300 DSP Inverter Generator
Maintaining your Generator
Cleaning
Keep the generator set clean and free of foreign material. Clean generator at least once
monthly. A soft brush may be used to loosen caked-on dirt. Use a soft, damp cloth to
wipe away loosened dirt. To clean dirt from hidden or remote areas of the unit, use dry,
filtered, low pressure air or vacuum system.
CAUTION:
DO NOT
use a forceful spray of water to clean the
generator. Water can penetrate generator’s electrical
system, which could reduce insulation resistance.
Possible generator failure may result.
Storing or Transporting
•
Turn fuel tap off.
•
Storage Petrol models - drain carburetor and fuel tank.
Servicing
•
First service 20 hours
•
Service intervals thereafter 50 hours
If operating in hot dusty conditions oil and air filters must be checked daily and service
intervals should be every 10 hours initially and every 25 hours thereafter.

page 18
Genquip Gi3300 DSP Inverter Generator
Specifications & Dimentions
GENERAL
OVERALL LENGTH 585 mm
OVERALL WIDTH 420 mm
OVERALL HEIGHT 470 mm
DRY WEIGHT 30 kg.
GROSS WEIGHT 32 kg.
FUEL TANK CAPACITY
7 litres
NOISE LEVEL 53-58 dB (at 7 metres)
GENERATOR
TYPE
AC OUTPUT,
Multistage permanent-magnet generator
RATED OUTPUT 3000 Watts
MAX OUTPUT 3300 Watts
FULL TANK OUTPUT 13500 Watts
RUN TIME AT 1/2 RATED LOAD 8.5 hours
RUN TIME AT RATED LOAD 4.5 hours
POWER CONVERSION RATE 85-92%
RATED VOLTAGE 240 V
RATED FREQUENCY 50 Hz
RATED CURRENT 13A
DC OUTPUT
12V/8A
ENGINE
TYPE 166F, OHV, AIR-COOLED,
4 - STROKE
STARTING SYSTEM RECOIL START
CYLINDER ARRANGEMENT INCLINED, SINGLE CYLINDER
BORE X STROKE 66mm X 50mm
IGNITION SYSTEM CDI
SPARK PLUG TYPE BPR4ES (NGK) / F7RTC
GAP 0.8 (0.028 - 0.031) inches
DISPLACEMENT 171cc
RATED OUTPUT 4.9HP at 3600 r/min
FUEL Unleaded Petrol
ENGINE OIL QUANTITY
600 ml

page 19
Genquip Gi3300 DSP Inverter Generator
B Black
Br Brown
G Green
L Blue
O Orange
R Red
W White
Y Yellow
P Pink
B/W Black/White
G/Y Green/Yellow
W/L White/Blue
1/ Main coil
2/ Sub coil
3/ Control unit
20/ AC indicator light
5/ AC receptacle
6/ Ground (Earth) terminal
7/ Economy Control Switch
8/ Accelerator controller
9/ Engine switch
10/ Oil warning light
11/ Oil warning unit
12/ Oil level gauge
13/ Ignition coil
14/ Spark plug
15/ AC-CDI unit
16/ Pulsar coil
17/ Stepping motor
18/ Charge coil
19/ DC receptacle
20/ Overload indicator light
21/ Ballast
Color code
Wiring Diagram
18
2
1
2
G/Y
R
G/Y
R
G/Y
R
G/Y
R
B
B B
L
L L
L
L L
B
B B
3
16
17
G/Y
G
G
Y
R
L
O
R
O
Y
P
L
Y
Y
W
8
G/Y
G/Y
B/W
W
R G/Y B/W
R G/Y
G
G/Y
G/Y
B/W
G
W/L
W
13
14
12
B
L
R
Y
L
G
11
Y
L
Y
L
10
R
R
R
R
9
15
R
R
R
R
W
G
Y
7
6
G/Y
R
R
B
B
R
R
5 R
B
5
G/Y
19
B
20
R
21
Y
Y
R
B
R
R
G
Y

page 20
Genquip Gi3300 DSP Inverter Generator
Troubleshooting
Engine Won’t Start
Carefully inspect the generator set before you first use it, look for the following
discrepancies:
1. Fuel system, engine is not getting fuel.
• No fuel in tank... Supply fuel.
• Clogged fuel line... Clean fuel line.
• Foreign matter in fuel filter... Replace fuel filter.
• Clogged carburetor... Clean carburetor.
2. Engine oil light flashes
• Oil level is low... Add engine oil.
3. Electrical system
• Engine switch to “ON”. Poor or no spark.
• Spark plug is dirty... Replace sparkplug.
• Faulty ignition system... Consult dealer.
4. Compression Insufficient
• Worn out piston and cylinder... Consult dealer.
Generator Won’t Produce Power
Stop the engine, then restart. If A/C lights continue to flash consult your dealer.
Storage
Long term storage of your machine will require some preventive procedures to guard
against deterioration.
Drain The Fuel
1. Remove the fuel tank cap. Drain the fuel tank into an approved gasoline container
using a commercially available hand siphon. Then, install the fuel tank cap.
WARNING:
Fuel is highly flammable and poisonous.
Wipe up any spilled fuel immediately.
2. Drain fuel from the carburetor by loosening the drain screw on the carburetor float
chamber.
3. Turn the fuel cock lever to “OFF”. Start the engine and leave it run until it stops. This
will burn any remaining fuel in the carburetor.

page 21
Genquip Gi3300 DSP Inverter Generator
Engine
1. Remove the spark plug, pour about one tablespoon of SAE 10W30 or 20W40 motor
oil into the spark plug hole and reinstall the spark plug. Turn over engine several
times (with ignition off) to coat the cylinder walls with oil.
2. Pull the recoil starter until you feel compression. The stop pulling. (This prevents the
cylinder and valves from rusting).
3. Clean exterior of the generator.
4. Store the generator in a dry, well- ventilated place, with the cover placed over it.
5. The generator must remain in a vertical position when stored, carried or operated.

page 23
Genquip Gi3300 DSP Inverter Generator
Notes

page 24
Genquip Gi3300 DSP Inverter Generator
www.genquip.com.au
Genquip Warehouse
45 Riverside Road
Chipping Norton NSW
Call 1300 730 716