PDF User Manual

  1. Home
  2. Manuals
  3. Genie DirectLift 2060 Operation And Maintenance Manual

Genie DirectLift 2060 Operation And Maintenance Manual

DirectLift 3060 DirectLift Directlift 2060 Directlift plus 3060

Made by: Genie
Type: Operation And Maintenance Manual
Category: Garage Door Opener
Pages: 14
Size: 1.63 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

C

omplete

 

with

 i

ntelliCode

 

R

emote

 C

ontRol

 

and

 SeRieS ii 

e

leCtRoniCS

t

able

 

of

 C

ontentS

Warranty Information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Safety Information    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Safety Features   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Important Installation Instructions  .  .  .  .  .  .  . 3
Pre-Installation Checklist  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4-6
Adjustments  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7-8
Programming the Remote Control   .  .  .  .  .  . 9
Installing lightbulb and lens  .  .  .  .  .  .  .  .  .  .  .  .  . 9
Scheduled Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Troubleshooting Guide   .  .  .  .  .  .  .  .  .  .  .  .  .10-11
Wiring Diagram  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Parts Lists and Exploded Views  .  .  .  .  .  .12-13
Accessories  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14

For up to 7’-6” tall Doors.  (Extension Kit available for 8’ 

Doors)
Included Wall Control MUST be installed prior to Operation  of 

this Garage Door Operator.
Safe-T-Beam® Safety Reverse System Must be Installed and  

the Force Controls MUST be Properly Set to close door.
This Equipment meets or exceeds all Federal, State and UL 

325 Safety Requirements.

SA

VE

 TH

IS

 M

AN

UA

L F

OR 

FUTURE 

REFERENCE

Having Difficulty? Need Help?

Please call us: 1-800-35-GENIE (354-3643) 

 

 

 

 

www.geniecompany.com
Please have Model information  

 

 

 

 

ready when calling

.

3622836177

®

AC POWERED SCREW DRIVE OPENERS

2060

3060

Operation and 
Maintenance Manual

 


background image

2

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Model Number and 
Serial Number are 
located on front panel 
inside the lens .

INCLUDED IN THIS PACKAGE
   Manual  1) Warranty Information
 

2) Pre Installation Checklist to be reviewed prior  

 

    to any assembly or installation

 

3) Necessary Adjustments

 

4) Programming Remote Devices

 

5) Maintenance and Troubleshooting

 

6) Parts Explosions

 

7) Accessory Order Form

 

8) Door Opener Association Safety and  

 

 

     Maintenance Brochure (DASMA)

 

9) Entrapment Warning Label - To be Adhered in  

 

     close proximity to wall control

   Poster  1) Pictorial and step by step opener assembly    
 

     instructions

 

2) Pictorial and step by step opener installation  

 

     instructions

IT IS CRITICAL THAT ALL SAFETY WARNINGS 

MARKED CLEARLY IN BOTH THE MANUAL 

AND POSTER ARE READ, UNDERSTOOD AND 

FOLLOWED.

t

he

 G

enie

 C

ompany

 l

imited

 w

aRRanty

What is covered?
 Any defect in material and product workmanship from personal, normal 

household use in accordance with the Owner’s Manual .
For how long? 

 

 

 

 

MODEL 2060L-07  .  .  . 15 years on motor, 3 years all other parts . 

 

MODEL 3060L-07  .  .  . Lifetime*  on motor, 3 years all other parts . 

 

*Lifetime = For as long as you own your home .
Who gets the warranty? 
This warranty is  limited to the consumer who originally  purchased the prod-

uct .
Geographic scope: 
This warranty applies only to units installed and operated within the country 

where they were purchased .
Limitations:  

 

 

 

 

IMPLIED WARRANTIES, I N CLUDING THOSE OF FITNESS FOR A PAR   TICULAR 

PURPOSE AND MERCHANT  ABILITY (AN UNWRITTEN WARRANTY THAT THE 

PRODUCT IS FIT FOR ORDINARY USE), ARE LIMITED TO ONE YEAR FROM 

THE DATE OF PURCHASE . GENIE WILL NOT PAY FOR: LOSS OF TIME; 

INCONVENIENCE; LOSS OF USE OF YOUR GENIE PRODUCT OR PROPERTY 

DAMAGE CAUSED BY YOUR GENIE  PRODUCT OR ITS FAILURE TO WORK; ANY 

SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES; OR ANY DAMAGES 

RESULTING FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT .
Some states and provinces do not allow  limitations on how long an implied  

warranty lasts or the exclusion of incidental or consequential damages, so the 

above limitations or exclusions may not apply to you .
This warranty is the only one we will give on your Genie product, and it sets 

forth all our responsibilities regarding your Genie product . There are no other 

express  warranties .
State and province rights: This warranty gives you specific legal rights, and 

you may also have other rights which vary from state to state and province to 

province .
How to get warranty service: 
To obtain warranty service for your Genie product, you must provide proof of 

the date and place of purchase of the product .
1. Do-It-Yourself-Service

.

 

 Call the Genie Customer Service toll free at 1 .800 .354 .3643 to speak in  

person to a trained Genie representative for assistance in diagnosing the 

problem and arranging to supply you with the required parts for do-it-

yourself repairs . Trained service representatives are available Monday-Friday, 

8:00 a .m . - 11:00 p .m ., Eastern Time, and on Saturday, 10:00 a .m . to 8:00 p .m ., 

Eastern Time (subject to  holidays) You may also get the information you 

need at 

www.geniecompany.com

 . 

2. Service From Authorized Dealers

.

  

 

 

You also may obtain warranty service from Genie authorized dealers by calling the 

Genie Customer Service at 1 .800 .354 .3643 or by visiting 

www.geniecompany.com

 

before scheduling warranty service . If warranty service is provided by an authorized 

dealer, Genie will provide all required parts under  war ranty at no charge to you, but 

the  dealers are  independent business  people and may render a bench or  ser vice call 

charge for their services . Genie will not reimburse you or  other wise be responsible for 

those charges .

  We suggest that you retain your original packing material in the event we choose to 

repair or replaqce your Genie Product and request that you ship it to us . Be sure to 

include your name, address, telephone number, proof of date and place of purchase 

and a description of the operating problem . After repairing or replacing, your Genie 

product, we will ship it to your home at no cost to you for parts and labor, but you will 

have to pay a  minimum of $5 .00 for shipping and  handling charges .

  Your choice of either one of the above-described service options is your exclusive 

remedy under this warranty .

What this warranty does not cover: 

This  warranty does not cover batteries (which are considered replaceable parts), 

 installation, commercial use, defects resulting from  accidents, damage while in transit 

to our  service location or damage resulting from alterations, misuse or abuse, lack of 

proper maintenance,  unauthorized repair or modification of the product, affixing of 

any attachment not provided with the product,  programming of the Remote Control 

Devices, Safe-T-Beam® adjustment/cleaning, staples through wiring, pinched or broken 

wires, Carriage disengaged, Force Control adjustments,  door out of balance,  broken 

springs or cables, power outages, use of extension cords, missing or damaged parts on 

discounted, clearanced, final sale or taped cartons, phantom operations (labor is not 

covered if Opener is functioning properly while technician is in garage),fire, flood, or 

acts of God, or other failure to follow the Owner’s Manual .

   

SAVE THESE INSTRUCTIONS

Visit Our Website at: 

www.geniecompany.com

FOR ANSWERS: CALL 1.800.354.3643

  Please note the following information,so it is available if you  

 

  need to call us.
  Date Purchased  

__________/_________/__________   

  Serial Number    

______________________________   

  Operator Model  

______________________________

  Remote Control Model  ______________________________
  Dealer Name    

______________________________

  Dealer Address   

______________________________

  City    

 

______________________________

  State / Zip  

 

______________________________ 

 NOTE

Please keep original or photocopy of your sales receipt 

with this manual for future reference should service 

ever be required.

 


background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

3

oVeRView of potential haZaRdS

Overhead doors are large, heavy objects that move with the help of springs under high tension and  electric motors .  Since moving objects, springs 
under tension, and electric motors can cause injuries,  your safety and the safety of others depend on you  reading the  information in this manual .  If you 
have questions or do not understand the information  presented,  call The Genie Company .  or your local Genie Distributor . 

POTENTIAL HAZARD

EFFECT

PREVENTION

• Keep people clear of  opening while door is  moving.
• Do Not allow children to play with the door  operator .
• Do Not operate a door that jams or one that has a  broken spring .

MOVING DOOR

WARNING:

Could result in death 

or serious injury .

• Turn off power before removing operator cover.
• When replacing cover, make sure wires are not pinched or near   

                   

  moving parts .
• Operator must be properly grounded.

ELECTRICAL SHOCK

• Do Not try to remove, repair or adjust springs or anything to   

  which door spring parts are  fastened, such as, wood blocks,  

  steel brackets, cables or other like items .
• Repairs and adjustments must be made by a trained door    

  system technician using  proper tools and  instructions .

HIGH SPRING TENSION

WARNING:

Could result in death 

or serious injury .

WARNING:

Could result in death 

or serious injury .

In this section, and those that follow, the words DangerWarning and Caution are used to emphasize important safety   
information .  The word:
 

indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury .

 

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .

 

indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage .

The word NOTE is used to indicate important steps to be followed or important considerations .

DANGER:

CAUTION:

WARNING:

Safe-T-Beam®  (STB) Non-Contact Reversing System 
Places an invisible beam across door opening, that reverses 
the door during down travel to the fully open position if 
anything passes through beam .  

Safe-T-Reverse®  Contact Reversing System 

 

 

Automatically stops and reverses a closing door  within 2 
seconds of contact with an object .

Safe-T-Stop®  Timed Reversed System   

 

 

Automatically opens a closing door, if door does not close 
within 30 seconds .

ForceGuard®  Control   

 

 

 

 

Used to set the force required for opening and closing 
door . For maximum safety, set the minimum force required 
to fully open and close door .

Automatic Lighting System 

 

 

 

 

Light bulbs up to 60 Watts max . , used for safer entries and 
exits . The lights turn on when door is activated and  
automatically turn off 4 .5  minutes later .

Manual Emergency Release 

 

 

 

 

Allows the garage door to be opened or closed manually 
for emergencies or maintenance .

 

 

IMPORTANT  INSTALLATION

INSTRUCTIONS

  1   READ AND FOLLOW ALL SAFETY, INSTALL ATION AND  

      OPERATION  INSTRUCTIONS . If you have any  

 

      questions or do not understand an instruction, call    

      your authorized Genie installation professional .

  2    Do Not install operator on an improperly  balanced    

      door .  An improperly balanced door could cause    

      severe injury .  Repairs and  adjustments to cables,     

      spring  assembly, and  other hardware must be made  

      by a trained service person using proper tools and    

       instructions .

  3   Remove all ropes, and disable all locks connected to  

      the door before installing operator .

  4   Install door operator 7 feet or more above the floor .   

      Mount the emergency release knob 6 feet above    

      the floor .

  5   Do Not connect the operator to the source of power  

      until instructed to do so .

  6    Locate the control button:   

 

 

 

      •  Within sight of door. 

 

 

 

 

      •   At a minimum height of 5 feet, so small  children    

        cannot reach it .   

 

 

 

 

      •   Away from all moving parts of the door.

  7   Install the entrapment WARNING label next to the    

      wall button or console . Install the emergency release  

      tag on, or next to, the emergency release

  8   The operator must reverse when the door  contacts a  

      1-1/2 inch high object on the floor at the  center of    

      the doorway . This is about the size of a 2” x 4” board  

      laid flat .

  t

o

 

ReduCe

 

the

 

RiSk

 

of

 

SeVeRe

 

injuRy

 

oR

 

death

:

          

  

       

WARNING:

S

afety

 f

eatuReS

 


background image

4

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Figure 2   Note Door Type

 

 

 

 

          

m

eaSuRe

 G

aRaGe

 d

ooR

 h

eiGht

A  Measure door height (floor to top of door) using a tape measure .
B  This new Garage Door Opener is designed for doors up to and 

including 7’ 6” tall . If door height is 7’ 6” or less continue to Check Step 4 . 
C 

If door height is 8’-0”, you need a Rail Extension Kit . (Figure 3) .

(See Accessories Order Form, Page 14) .
D  If the door height is taller than 8’-0”,  the opener you purchased is 

the wrong version . Contact your Customer Service Representative  

 

at 1-800-354-3643 .

 Check Step 3:

p

Re

-i

nStallation

 C

heCkliSt

This Opener includes parts and supplies needed to install in most 

garages and connect to most garage doors .  There are many variations 

of garages and garage doors .  A few additional parts and supplies may 

be needed to install Opener into your garage and connect to your 

garage door .   While checking items listed below, note any additional 

items you will need .

 Tools used in this section:

 12’+ Tape Measure        Pencil        Ladder       Level

Check following items before assembling Opener: 

 

 

 

 

 

C

heCk

 d

ooR

 C

ondition

 

and

    

         

t

hiCkneSS

 Check Step 1:

 

 

 

 

 

C

heCk

 G

aRaGe

 d

ooR

    

 

         

a

liGnment

, o

peRation

,  

 

         

and

 b

alanCe

 Check Step 2:

          

   

  WARNING:

If your door sticks, binds, or is out of balance, have it adjusted 

by a Genie Factory Authorized Dealer .  Door springs, cables,  

pulleys, brackets and associated hardware are under extreme 

tension and can cause serious injury or death .

KEEP FEET CLEAR OF DOOR

3’ - 4’

Sectional 

Door

3’ - 4’

Figure 1  Checking door balance

One-Piece 

Door

Torsion 
Springs

Extension 
Springs

Center

Stile

Center Stile

Header Area

Figure 3   Rail Extension Kit

Rail Extension for 

8’ door

Check condition of vertical stile in center of door, and its connection to 

door’s top and bottom beams . (Figure 2)
A  If door frame is nailed together and not a solid connection, door 

frame must be braced or reinforced before installing Opener .
B  If door is “lightweight” (made with frame and skin - not solid), 

door (including door frame) must be braced or reinforced before 

installing Opener . 
C   A door opener reinforcement bracket may also be needed to  

connect garage door to Opener’s Door Bracket .  This Opener is 

designed for installation on a properly braced sectional door or  

solidly braced one-piece door . 
D  Contact your Genie Factory Authorized Dealer or dealer of your 

garage door for any necessary bracing and a door opener    

reinforcement bracket (if needed) before proceeding .
E 

If you have a wooden door, measure door’s thickness . If your door  

is less than 2” thick,  brace door or use shorter Door Bracket Lag Screws 

(1/4” x 1-1/4” – not included)

A  Raise door, check alignment and see if it moves freely (Figure 1) .  

If door appears out of alignment, binds, or does not move smoothly,  

contact a Genie Factory Authorized Dealer or dealer of your garage 

door for repairs and adjustments to door mechanism . 
B  Raise door to 3’ – 4’ above ground and carefully let go .  Door 

should stay stationary .  Slight movement is acceptable .  More than 

slight movement means door is out of balance .  Contact a Genie 

Factory Authorized Dealer or dealer of your garage  

 

 

door for repairs and adjustments to door  mechanism . 

C 

Check door type .  Make a note of whether it is a sectional or a one-

piece door for reference later (Figure 2) .

B  Find Header Bracket mounting height  (Figure 4):  (Do not attach 

Header Bracket) .
 

 

Raise door, watching top edge of door and stop door  

 

 

 

when its edge reaches its highest point .

 

 

Measure distance (“H”) from top edge of door to floor .

 

 

– 

For sectional doors, add 1” to “H” .   Mark a point  

 

 

 

 

on center line .  Bottom of Header Bracket will be 

 

 

 

 

installed here .

 

 

– 

For one-piece doors, add 7” to “H” .  Mark this point on     

 

 

 

center line .  Bottom of Header Bracket will be  

 

 

 

 

installed here .

 

 

 

 

 

C

heCk

 d

ooR

 h

eadeR

 a

Rea

A  Find vertical center line of door and header:   

 

 

 

 

Close door . 

   

 

 

 

 

 

 

Measure door width at top .   

 

 

 

 

 

Mark a point at center of door and on header directly  

 

 

 

above door .  Draw a center line to connect points . 

 Check Step 4:

          

                NOTE

The header is a heavily reinforced section of the wall just 

above the top of the garage door opening . 

Figure 4  Find Highest Point of Travel

SECTIONAL DOOR

ONE-PIECE DOOR

HEADER

HEADER

 


background image

C 

Check wall for a stud or a solid header at your mark:  (If checking a  

finished wall, a stud finder may be helpful) .
 

 

If location is above Header, a 2” x 6” board must be  

 

 

 

screwed to studs beside your mark with at least two Lag    

 

 

Screws and Flat Washers (not provided) .

 

 

Transfer your mark to new mounting board .

Check ceiling or space above where Opener Power Head will be 
mounted (Figure 5):  There must be a 120 Volt grounded outlet or 
wiring box within 3 feet of Power Head .

A  The measurements above are taken from the garage door  
centerline toward the rear of the garage .
B  Find location of ceiling joist or truss above where Opener Power 
Head will be and estimate type and quantity of materials needed for 
your installation (Figure 6A & B) .

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

5

          

           

  WARNING:

Door springs are under extremely high tension and 

should be handled ONLY by a trained professional . 

          

                NOTE

  For all types and styles of doors: 

  

 

    – If the ceiling in your garage is so low that there is  

      not at least a 3” space above the Header Bracket  

      mounting point, contact a Genie Factory    

      Authorized Dealer . 

 

 

 

•  If a door spring is in the way, place the Header Bracket  

  above the spring . Do Not move the door spring .

 

 

 

 

 

 

        

C

heCk

 p

oweR

 h

ead

  

 

 

 

 

 

         m

ountinG

 a

Rea

 Check Step 5:

Door Center Line

Figure 5  Check Power Head location

11’

Figure 6B   

FINISHED CEILINGS 

 

Locate ceiling joists or trusses using 

a stud finder or similar device . 
Attach angle iron(not included) to 

joists or trusses through finish  

material using Lag Screws .

MOUNTING EXAMPLES

Perforated Straps

Conduit

Perforated Angle Iron

Wood

 

 

 

 

 

 

         

C

heCk

 C

eilinG

 

foR

 G

Rounded

    

 

 

 

 

 

p

oweR

 S

ouRCe

 

 Check Step 6:

          

            NOTE

Permanent wiring must be installed by a Licensed 

Electrician .  Not all Genie Factory Authorized Dealers 

are Licensed Electrician’s .  Contact someone who is a 

Licensed Electrician .

       

WARNING:

Do Not use an extension cord!  Extension cords can 

cause dangerous overheating conditions .

Do Not use portable generator!  This product is 

designed to operate using standard house current . Do 

Not use alternate power supplies, 

A  Check that there is a 15 Amp 120 Volt grounded electrical  

outlet or grounded permanent wiring box (per building code)  

within 3’ of Opener Power Head: Figure 5 

 

 

 

 

If not, an outlet or wiring box must be installed .  Contact  

 

 

a licensed electrician for installation . 

 

 

If building codes require permanent wiring, Power Head  

 

 

must be partially disassembled to install appropriate  

 

 

wiring in place of Power Cord .  (See Assembly and  

 

 

Installation Poster .)

 

 

 

 

 

 

 

         

C

heCk

 S

afe

-t-b

eam

®    

 

 

 

 

 

m

ountinG

 b

RaCket

 l

oCation

 Check Step 7:

Check for wood garage frame, jamb, or masonry at mounting 
location (6” above floor) with attachment tabs facing away 
from garage door (Figure 7) . 

A  If you cannot mount Safe-T-Beam® Mounting Bracket to      
wood frame:
 

 

Concrete screws and concrete anchors (not included)  

 

 

must be used to mount Brackets on masonry with  

 

 

attachment tabs facing away from garage door . 

 

Source

Sensor

Safe-T-Beam®

Mounting Bracket

Top of 

Bracket 

6” above 

floor

Figure 7  Mounting 

                 Safe-T-Beam® 

                 Components

Grounded 

outlet

10’

(7’-6” door)

(8’ door)

Figure 6A

OPEN CEILINGS Straps and angle iron may attach directly to joists  

or trusses .

 


background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

6

Figure 8  Recommended Tools

Go to Assembly and Installation Poster for full 
Installation Instructions.

 

 

 

 

 

 

 

         

R

eCommended

 

toolS

A  Tools (Figure 8):
B  Additional tools to make installation easier: 

 

 

 

Slotted and phillips screw-driver bits 

 

 

 

Stud finder 

   

 

 

 

 

 

Sheet-metal cutting snips

 Check Step 8:

 

 

 

 D 

         

R

emoVe

 e

xiStinG

 G

aRaGe

 

         

d

ooR

 l

oCkS

Check that the garage door locks, rope, and T-Handles are 
removed from the garage door before starting the installation .
A  If your garage does not have a separate entry door, it is 
highly recommended to install a Genie Emergency Release 
Kit (GER-2) .   Emergency Release Kit lets you open the garage 
door from outside if there is a ppower failure .  (Please see 
Accessories Order  Form on page 14 .)

 Check Step 9:

Before going further, get any items and tools if needed 
for your installation

p

 

Garage door frame reinforcement brackets, screws, bracing  

 

 

or reinforcement kits (dealer)

p

  Lag Screws (1-1/4”) for a wood door less than 2” thick (store)

p

  Electrical outlet and/or wiring (supplied by a licensed electrician)

p

  Sufficient angle iron or strapping for hanging Power Head (store)

p

  60 Watt light bulbs (Rough service bulbs recommended)(store)

p

  GER-2 Emergency Release Kit for entry during power failure (store)

p

  Wood for header, ceiling, and/or door braces (store)

p

  Masonry fasteners for Safe-T-Beam® Bracket installation (store)

p

  Safe-T-Beam® Bracket Extensions (dealer)

p

  Masonry drill bit (store)

p

  Extension Kit (for 8’ Garage Doors)(dealer)

      

WARNING:

TO REDUCE THE RISK OF 

SEVERE INJURY OR DEATH

IMPORTANT 

SAFETY INSTRUCTIONS

 

1  READ AND FOLLOW ALL INSTRUCTIONS .
2  Never let children operate or play with the Door Controls .  Keep  

 

the Remote Control away from children .

3  Always keep the moving door in sight and away from people and  

 

objects until the door is completely closed .    

 

 

 

NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR .

4  NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR . 
5  Test Opener monthly .  The door MUST reverse on contact with   

 

a 1-1/2” high object (or a 2” x 4” board laid flat) at the center of the  

 

doorway on the floor .  After adjusting either the Force or the Limit  

 

of travel, retest the Door Opener .  Failure to adjust the  Opener   

 

properly may cause severe injury or death .

6  When possible use the Emergency Release only when the door  

 

is closed .  Use caution when using this Release with door open .   

 

Weak or broken springs are capable of increasing the rate of door  

 

closure and increasing the risk of severe injury or death .

7  KEEP GARAGE DOORS PROPERLY BALANCED .  See Owner’s    

 

Manual .  An improperly balanced door increases the risk of  severe  

 

injury or death .  Have a Genie Factory Authorized Dealer make   

 

repairs to cables, spring assemblies, and other hardware .

8 

SAVE THESE INSTRUCTIONS.

noteS, RemindeRS

 


background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

7

 

 

 

 

 

 

        

C

h

     a

djuStinG

 l

imit

 S

witCheS

 

         

        

and

 f

oRCe

 C

ontRolS

  Adjustment 1:

A  CLOSE ADJUSTMENT 

 

 

 

 

 

• 

On front panel of Power Head find adjusting screw   

 

 

marked “CLOSE” (Figure MA-1) .     

 

 

 

 

Gently turn screw counterclockwise until it stops .   

 

 

– 

Very little force is required to turn adjusting screw . 

         

Press Wall Console to close garage door .   

 

 

 

– 

Observe if door stops at “CLOSE” limit switch .    

 

 

 

(Figure MA-2) . If door is fully closed—adjustment is  

 

 

 

finished . Go to “OPEN” Adjustment . 

 

 

 

 

– 

If door stops but is not fully closed, 

 

 

 

 

 

a .  Measure distance between bottom of door  

 

 

 

 

and floor .  

 

 

 

 

 

 

 

b .  Move “CLOSE” Limit Switch that same distance  

 

 

 

 

toward door . 

 

 

 

 

 

 

– 

If door stops and/or reverses before reaching the  

 

 

 

“CLOSE” Limit Switch  

 

 

 

 

 

 

a .  Slightly increase CLOSE Force setting (clockwise) . 

 

 

– 

If door reverses after contacting floor, move Limit  

 

 

 

Switch toward Power Head .   

 

 

 

 

– 

If door fails to move, check Safe-T-Beam® System .  

 

 

 

See Troubleshooting Section, pages 10-11 .

 

 

Tighten Limit Switch Set Screw . Do not over-tighten  

 

 

(strip) Limit Switch Set Screw .

B  OPEN ADJUSTMENT  

 

 

 

 

 

• 

On front panel of Power Head find adjusting screw   

 

 

marked “OPEN” (Figure MA-1) .     

 

 

 

 

Gently turn screw counterclockwise until it stops .   

 

 

– 

Very little force is required to turn adjusting screw . 

      

Press Wall Console to close garage door .   

 

 

 

– 

Observe if door stops at “OPEN” limit switch .   

 

 

 

(Figure MA-2) . If door is fully open—adjustment  

 

 

 

is finished .    

 

 

 

 

 

 

– 

If door stops but is not fully open, 

 

 

 

 

 

a .  Measure distance between bottom of door  

 

 

 

 

top of door opening .  

 

 

 

 

 

 

b .  Move “OPEN” Limit Switch that same distance  

 

 

 

 

toward Power Head . 

 

 

 

 

 

– 

If door stops before reaching the “OPEN”  

 

 

 

 

Limit Switch  

 

 

 

 

 

 

 

a .  Slightly increase OPEN Force setting (clockwise) . 

 

 

– 

If door fails to move, see Troubleshooting Section,  

 

 

 

pages 10-11 .  

 

 

 

 

 

 

Tighten Limit Switch Set Screw . Do not over-tighten  

 

 

(strip) Limit Switch Set Screw .

C  Run Door Opener     

 

 

 

 

 

• 

Cycle opener a few times to double check settings .   

 

 

 

Repeat adjustment steps as necessary . 

          

             

   WARNING:

•  A moving garage door can cause serious injury or death.
•  Keep the path clear.
•  Position the ladder to the side of the Power Head so it is  

 

clear of all moving parts of the Opener and the door .

•  Set the door Opener to use the minimum force needed  

 

to open the door .

 NOTE

  Little effort is required to turn the Force              

 

Adjusting Knobs .

  If the door stops moving while opening or    

 

closing, adjust the Open Force or Close Force   

 

Controls slightly clockwise (to slightly  

 

 

increase the force) and retry  the step .

  The Open Force and Close Force Controls are  to  

 

be set to the minimum force necessary to    

 

ensure the door smoothly opens and  

 

 

closes completely .

  Ensure the Carriage Assembly is engaged and is  

 

between the two Limit Switches before  

 

 

operating the Opener .

Figure MA-1  Making Force Adjustments

OPEN

CLOS

E

OPEN

CLOSE

FORCE

CONTROLS

m

aintenanCe

 

and

 a

djuStmentS

Figure MA-2  Making Force Adjustments

OPEN

CLOSE

OPEN

CLOSE

 


background image

8

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

A  To program one Button of a Remote Control (Figure MA-4): 
 

 

Locate Learn Button and Learn Indicator Light  

 

 

 

on left side of Power Head (Figure MA-5) .

 

• 

Press and release Learn Button .  Red Learn   

 

 

 

Indicator Light will blink 2 times per second .

 

• 

Press Remote Control Button once within 30  

 

 

 

seconds . Red Learn Indicator Light will stay lit .

 

• 

Press Remote Control Button again .  Red Learn  

 

 

 

Indicator Light will go out, indicating that    

 

 

 

memory is stored . 

B  Program each additional Remote using step A above  

 

 

(up to seven) .

 NOTE

  Each Remote Control must be programmed    

 

separately .

  The Remote Controls will not cause the door    

 

Opener to close the garage door if the Safe-T-  

 

Beam® System is malfunctioning .

  When programming the Remote Controls, they  

 

must be at least 24” from the Antenna Wire .

  If the red Learn Indicator Light blinks   

 

 

approximately 4 times per second,    

 

 

programming has stopped .   If programming   

 

has stopped, repeat the above steps .

  Each Button on a 2 or 3 Button Remote Control  

 

is for a different Opener .  You cannot use more  

 

than one Button per Remote, per Opener .

  A maximum of seven Remote Controls or  

 

 

Wireless  Keypads can be stored into the  

 

 

Receiver at one time .  If a Remote Control  

 

 

becomes lost, or if you want to delete a Remote  

 

Control or Wireless Keypad, see “To Erase All    

 

Receiver Memory .”

 

 

 

 

 

 

 

 

        

C   

p

RoGRamminG

 

the

          

     R

emote

 C

ontRolS

 Programming 1:

a

CCeSSoRieS

To Erase All Remotes from Power Head Memory

A  Press and hold Learn Button on Power Head for 10  

 

 

seconds or until Learn Indicator Light goes out .    

 

 

Memory is erased:

 

 

Program Transmitter/Receiver again as needed .

To Replace Remote Control Battery

A  FOR NON-FLASHLIGHT MODELS 

 

 

 

 

 

Pop off the back of the transmitter . 

 

 

 

 

– 

Use coin, pen, screwdriver or any similar device .  

 

 

– 

Replace old Battery with new coin type battery .   

 

• 

Replace back of remote.

B  FOR FLASHLIGHT MODELS 

 

 

 

 

 

 

Slide open battery cover .   

 

 

 

 

 

– 

Replace old Battery with new AAA  battery . 

 

 

• 

Replace battery cover.

A  Open garage door using  

 

 

 

 

 

Wall Console .

B  Lay a 2” x 4” board flat in center  

 

 

 

 

of doorway .

C  Close door using Wall Console .
D  Check that door stops and reverses    

 

 

 

within 2 seconds after it  

 

 

 

 

 

contacts board:

 

 

If door does not reverse, decrease    

 

 

 

 

Close Force until door reverses .

 

 

If door still does not reverse,  

 

 

 

 

 

move Limit Switch toward door .

E  Check Safe-T-Beam® System    

 

 

 

 

operation: 

 

 

 If beam is blocked, door will  

 

 

 

 

 

not close .

 NOTE

The door must contact the 2” x 4” board before the Carriage activates 

the Close Limit Switch .  If not, readjust the Close Limit Switch .

 

 

 

      

 

 

 

 

        

C

h

        

S

ettinG

 C

ontaCt

  

 

         

           R

eVeRSe

 f

unCtion

 Adjustment 2:

 NOTE

Limit Switch and Force Adjustments must be completed 

before checking the contact reverse function (Figure MA-3) .

2” x 4” board

laid flat

Figure MA-3

Transmitter Compliance Statement

 


background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

9

Remote Control Operation

A  Press Button on Remote Control .  Garage door will move .
B  Press Button again .  Garage door will stop: 

 

 

 

 

The door automatically stops at the end of the open or    

 

 

close cycle .

C  Press Button again .  Garage door will reverse .

          

                

WARNING:

A moving garage door may cause serious injury or death .
  Keep people clear of opening while door is moving .
  Do not allow children to play with the Remote Controls .
If the Safety Reverse does not work properly:
  Close the door and disconnect the Opener using the  

 

 

Emergency Release Cord .

  Do not use the door Opener, Remote Controls, or  

 

 

Wireless Keypad .

  Refer to the door and door Opener Owner’s Manuals  

 

 

before attempting any repairs .

1 2 3 4

Figure 13 Learn Code Button and Indicator Light

Figure MA-5  Learn Code Button and Indicator Light

1 Button Compact Remote

w/Docking Station

Figure MA-4  Genie Remote Controls

3 Button Compact Remote

w/Docking Station

A  Install two 60 Watt light bulbs (not included) into Light 
Sockets (Figure MA-6):
 

  Rough service, 130 Volt bulbs are recommended .

B  Hold the lens, with the bottom hinges pointing up, against 
the power head metal front cover (Figure MA-7) . 

 

 

    Insert (2) #8-32 x 3/8” Phillips Hex Head Screws    

 

    through the Bottom hinges and into holes provided 

 

    in metal front cover of Power Head (Figure MA-7) .   

 

    Tighten screws . 

 

 

 

 

 

    Flip Lens up and fasten with (2) #8-32 x 3/8” Phillips Pan  

 

    Head Screws where indicated .

Figure MA-7 

Figure MA-6 

i

nStall

 l

iGht

 b

ulbS

 

and

 l

enS

     

 WARNING:

Use the Wall Console included with Opener .  Any 

other wall console can cause the Opener to operate 

unexpectedly and the light to stop working .

To program a Homelink® or Car2U Device:
(This GDO is Homelink® and Car2U compatible)

 

  Follow the Homelink® or Car2U instructions in your car  

 

  owner’s manual .

 


background image

10

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

A  Monthly:   

   

 

 

 

 

 

  Door springs and door hardware:  

 

 

 

  –  Oil door roller, bearings, and hinges using silicone  

 

   

lubricant or light oil .

    Balance Door .
   

–  Close door . 

 

 

 

 

 

   

–  Release Carriage Assembly from Rail  Assembly by pulling  

   

 

the Emergency Release Knob towards the door . 

 

   

–  Raise door manually 3’- 4’ and verify that door stays at   

   

 

that position . See Check Step 2 on page 4 .

   

–  Reattach Carriage Assembly to Rail Assembly:  

 

   

 

a .    Pull the Emergency Release Knob toward    

 

   

 

 

Power Head .   

 

 

 

 

   

 

b .    Close door .

  •  Contact Reverse Test. 

 

 

 

 

   

–  Perform Adjustment 2 on page 8 .

 NOTE

When the door is 3’ - 4’  above the ground, the door 

should stay open .   Slight movement is acceptable .  If 

the door moves too much, contact a Genie Factory 

Authorized Dealer for service or call Customer Service at 

1-800-35-GENIE.

          

            

WARNING:

Do not operate door automatically or manually if springs 

are broken .  Contact a Genie Factory Authorized Dealer for 

service or call Customer Service at 1-800-35-GENIE .

If the door fails to reverse on contact with the board, 

adjust the Close Force Control as specified in Set Limit 

Switches and Force Controls on page 7 & 8 .  If the Opener 

still fails, contact a Genie Factory Authorized Dealer for 

service or call Customer Service at 1-800-35-GENIE .

 NOTE

Use ONLY Genie Lubricant (GLU-3) .  Other lubricants 

may damage the Opener . 

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCC Rules . 

Operation is subject to the following two conditions: (1) 

this device may not cause harmful interference, and (2) 

this device must accept any interference received, includ-

ing interference that may cause undesired operation . 

GLU-3
Lubricant

  

MAINTENANCE

B  Yearly:
    Wipe off old excess lubricant from Drive Screw .   

 

    Lubricate Drive Screw with Genie Lubricant (GLU-3)

C  As needed
  •  Replace lightbulbs. (See page 9)

Safe-T-Beam® System Self-Diagnostic Troubleshooting

    Source (Red LED) 

 Sensor (Green LED) 

 

Possible Problem 

 

Solution

  ON 

 

ON 

 

Normal operation 

None required

  OFF 

 

OFF

 

 

•  Power Head not powered 

•  Check breakers, fuses, plugs

   

 

 

 

•  Wiring from Power Head bad 

•  Check wiring for obvious shorts 

 
  OFF 

 

ON 

 

•  Wiring to Source missing or bad  •  Check wiring

   

 

 

 

•  Power has been interrupted 

•  Remove power and reapply

  2 BLINKS, Pause 

 

 

•  Beam not aligned 

•  Check Source, Sensor alignment 

  (Repeat)   

ON 

 

•  Beam obstructed 

•  Check for obstruction

   

 

 

 

•  Sensor defective 

•  Contact Customer Service

  2 BLINKS, Pause 

 

 

•  Wire to Sensor missing or bad 

•  Check wiring 

  (Repeat)   

OFF 

 

•  Sensor defective 

•  Contact Customer Service

  3 BLINKS, Pause 

 

 

•  Sensor receiving interference 

•  Determine source of interference 

  (Repeat)   

ON 

 

 

 

•  Check for interference from sun- 

   

 

 

 

 

 

   light or a source unit on an  

 

   

 

 

 

 

 

   adjacent door  

   

 

 

 

 

 

•  Contact Customer Service

  4 BLINKS, Pause 

 

 

•  Source not sending pulses 

•  Contact Customer Service 

  (Repeat)   

ON 

 

•  Source defective 

•  Contact Customer Service 

 

 

  

TROUBLESHOOTING

          

            

WARNING:

 


background image

11

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

General Troubleshooting 

   

   

Problem 

   

What To Do

  Opener does not run  

1 .  Check Lock switch on Wall Control (see Wall Console section on Installation Poster) . 

 

 

  from Wall Control 

2 .  Check Power Source: 

 

 

 

 

 

 

 

   

 

 

  For Grounded Plug Connection . 

 

 

 

 

 

 

 

   

 

 

 

–  Plug a lamp into the electrical outlet used for the door opener .    

 

 

 

   

 

 

 

 

a .  If lamp lights, power source is good .   

 

 

 

 

 

 

   

 

 

 

 

b .  If lamp does not light, check fuse or circuit breaker .   

 

 

 

 

   

 

 

  For Permanent Wiring Connection . 

 

 

 

 

 

 

 

   

 

 

 

–  Check fuse or circuit breaker . 

 

 

 

 

 

 

   

 

3 .  Check connections (see Wall Console section on Installation Poster): 

 

 

 

 

   

 

 

   At Power Head Terminals and Wall Control .  

  Door Opener starts 

1 .  Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires) 

 

 

  for no apparent reason 

 

Replace any shorting Staples and shorted Wires . 

 

 

 

 

 

 

   

 

2 .  Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory  

 

   

 

 

and reprogram for remaining remote controls .  (See Erase All Receiver Memory on page 11) .  

 

   

 

3 .  Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls .

  Door starts down, then 

1 .  Check Close Limit Switch setting (page 7 and Installation Poster) .  Adjust as needed . 

 

 

  stops before it is  

2 .  Check Force Setting (page 7 & 8) . Adjust as needed .   

 

 

 

 

 

  completely closed 

3 .  Check for shorted wires .

  Door starts down, then 

1 .  If a new installation, check Door Arm position .   

 

 

 

 

 

 

  stops and goes back up 

2 .  Check operation of Contact Reverse function . 

 

 

 

 

 

 

 

   

 

3 .  Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses . 

 

 

 

   

 

4 .  Check Safe-T-Beam® System diagnostic code . 

 

 

 

 

 

 

 

   

 

5 .  Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7 ) .   Adjust as needed .   

   

 

6 .  Check garage door for binding .

  Door will only run closed 

1 .  Check Open Limit Switch for a short circuit and for proper wiring .   

 

 

 

 

   

 

2 .  Check Open Force  adjustment (see Set Limit Switches and Force Controls on page 7 & 8) .  Adjust as needed . 

   

 

3 .  Check condition of garage door and door spring(s) . 

 

 

 

 

 

 

   

 

4 .  WARNING:  If you suspect a problem with the garage door hardware or springs, contact a Genie  

 

   

 

 

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE .  

 

 

   

 

5 .  Check position of Lock Switch on Console .

  Door will only run open 

1 .  Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart  

   

 

 

(page 10) .   

 

 

 

 

 

 

 

   

 

2 .  Check Close Limit Switch for a short circuit and for proper wiring .   

 

 

 

 

   

 

3 .  Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7 & 8) .  Adjust as needed . 

  Lights will not turn off 

1 .  Disconnect Wires connecting Wall Console to Power Head (see “Wall Console Installation”- on Installation post-

er) .   

 

 

Check their condition and either replace or reconnect .     

 

 

 

 

 

   

 

2 .  Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls   

   

 

 

or Wireless Keypad to operate Opener .  

 

 

 

 

 

 

 

   

 

3 .  Check for non-compatible wall control .

  Door starts up, but stops 

1 .  Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly 

 

  before it is    

 

balanced as detailed in Maintenance Section .   

 

 

 

 

 

 

  completely open 

2 .  WARNING:  If you suspect a problem with the garage door hardware or springs, contact a Genie Factory  

   

 

 

Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE .    

 

 

   

 

3 .  Check Open Limit Switch for a short circuit and for proper wiring .   

 

 

 

 

   

 

4 .  Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7 & 8) .  Adjust as needed .

  Operator runs, but door  

1 .   Ensure Carriage Assembly is engaged to Rail Drive Screw (see Install Carriage Assembly -INSTALLATION POSTER) .  

  does not move  

2 .  Check Force adjustment (see Set Limit Switches and Force Controls on page 7) .  Adjust as needed . 

 

   

 

3 .  Check that all sections of Rail Drive Screw are turning when Motor runs .  If not:  

 

 

 

   

 

 

•     Check condition (not cracked, split, or broken) and placement of Coupler.  Replace as needed. 

 

   

 

 

•  Check condition (not cracked, split, or broken) and placement of Collar and Clip.  Replace them                 

   

 

 

 

as needed .

  Wall Console Vacation  

1 .  Ensure Carriage Assembly is in contact with Close Limit Switch . 

 

 

 

 

 

  Lock function does  

2 .  Check when door is fully closed, that Carriage activates Close Limit Switch .  If not, adjust position of Close    

  not work 

 

 

Limit Switch (See page7) .

  Noisy Operation 

1 .  Be sure all fasteners are tight . 

 

 

 

 

 

 

 

   

 

2 .  Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly 

 

   

 

 

balanced as described in Maintenance Section (page 10) . 

 

 


background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

12

Opening Cover May Cause Electric Shock

w

iRinG

 d

iaGRam

1

2

3

4

5

6

7

8

9

10 11 12

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17

1

2

3

1

1

2

3

2

3

4

1

2

BLACK

ORANGE

ORANGE

ORANGE

ORANGE

CLOSE

OPEN 

YELLOW

YELLOW

WHITE

WHITE

WHITE

WHITE

WHITE

STRIPED

STRIPED

BLACK

BLACK

PURPLE

GREEN

BLUE

BLUE

RED / WHITE

RED

RED

GREY

GREY

BROW

N

ORANGE

GREEN

GREEN

GREEN

GREEN

OPEN

CLOSE

LIGHTS

WHITE

GREEN

POWER CORD

PRIMARY

SEQUENCER

MOTOR

RPM

SENSOR

WALL 

CONTROL

RADIO CONNECTOR

STB 

SYSTEM

TERMINAL 

STRIP

MOTOR

CAPACITOR

THERMAL 

PROTECTOR

PRIMARY

SECONDARY

TRANSFORMER

SEQUENCER 

HOUSING

(Vcc)

(SIGNAL)

(Vcc)

(TRIP)

(STB SYSTEM

)

(COMMAND)

)

(

1

%

&

/

0

.

+

1

-

$

'

*

3

5

Power Head Assembly

[1]

p

aRtS

 i

dentifiCation

 Item  Part Name
  1  Power Head Assembly 

1

  A  Cover (by Series Model) 

1

  B   Front Plate Assembly 

1

  C  Light Socket 

1

  D  Motor Parts 

2

  E  Receiver Assembly 

1

  F  Capacitor (By Series/Model) 

1

  G  Opto Wheel 

1

  H  Opto-Luctor Assembly 

1

 

J  Sequencer Assembly 

1

  K  Circuit Board Bracket 

  L  Transformer 

1

  M  Terminal Strip 

1

  N  No . 8-32 x 1/2” Hex Head Screw
 

  w/Lockwasher 

1

  P  No . 8-32 x 3/8” Slot Hex Head 
 

  Screw w/Lockwasher 

  R  Capacitor Isolator 

1

  4  1/4-20 Shoulder Bolt 

2

  5  1/4” Flange Nut 

2

  39  Coupler 

1

  41  No . 8-32 x 3/8” Phillips  

 

 

 

  Hex Head Screw 

4

  42  No . 8-32 x 3/8” Phillips 
 

  Pan Head Screw 

2

  48  Mounting Straps 

2

  49  Light Lens 

1

Power Head Parts List 

p

oweR

 h

ead

Number

Included

          

            

WARNING:

 


background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

13

15B

9

7

12

16

6

1

44

22

9

22

24

28

26

23

9

10

25

17

18

27

46

15A

4

39

5

47

25

24

8

11

3A

3B

3C

13

20

21

R

ail

p

aRtS

 i

dentifiCation

 

 Item  Part Name
  1  Power Head Assembly (see page 5) 

1

  3  Rail Assembly (3-piece) 

1

  3A  First Rail Section 

1

  3B  Middle Rail Section 

1

  3C  End Rail Section 

1

  4  1/4”-20 Hex Head Shoulder Bolt 

2

  5  1/4”-20 Hex Flange Nut 

2

  6  Carriage Stop 

1

  7  Rail Clamps 

4

  8  5/16” Hex Head Shoulder Bolt 

8

  9  5/16” Hex Flange Nut 

13

  10  Carriage Assembly 

1

  11  Collar 

2

  12  Retaining Clip 

2

  13  Rail Strap 

1

 15A  Open Limit Switch Assembly (grey) 

1

 15B  Close Limit Switch Assembly (brown) 

1

  16  #8-32 x 3/8” Hex Head Screw 

2

  17  Emergency Release Cord 

1

  18  Emergency Release Knob 

1

  19  Emergency Release Tag (not shown) 

1

  20  Header Bracket 

1

  21  Door Bracket 

1

  22  1/4” x 2” Lag Screw 

7

  23  Straight Door Arm 

1

  24  Clevis Pin 

2

  25  Cotter Pin 

2

  26  Curved Door Arm 

1

  27  3/8” x 7/8” Hex Head Bolt 

2

  28  3/8” Hex Flange Nut 

2

Parts List

 

(cont’)

Number 

Included

 Item  Part Name
  29  Wire (not shown) 

95 ft

  30  Insulated Staples (not shown) 

30

  31  Wall Button (not shown) 

varies

  33  Wall Console (not shown) 

varies

  35  Entrapment WARNING Label (not shown) 

1

  36  Safe-T-Beam (STB)Sensor (green LED) 

 

 

  (not shown 

1

  37  Safe-T-Beam Source (red LED) 

 

 

  (not shown) 

1

  38  Safe-T-Beam Bracket (not shown) 

2

  39  Coupler 

1

  40  #10 x 1-1/4” Phillips Hex Head Screw 

4

  43  Safety and Maintenance Guide  

 

 

  (not shown) 

1

  44  Wire Clip 

4

  46  5/16” x 3/4” Hex Head Bolt 

5

  47  1/4”-20 x 3/4” Self-tapping Screw 

3

  48  Mounting Straps 

2

  49  Light Lens (see page 5) 

1

  50  Remote Control (not shown) 

varies 

Number 

Included

~~

Parts List

 (cont’)

Rail Assembly

[3]

~~

 


background image

14

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

®

No C .O .D . shipments . Please include check or money 

order, made payable to The Genie Company . Do not send 

cash . Allow 3-4 weeks for delivery .  

1-800-354-3643 . Please have part number and credit 

card ready .  Mail Order Form to: Genie Company, 22790 

Lake Park Blvd, Alliance, Ohio 44601 . We accept Visa or 

Mastercard on phone orders only .

Please add local sales tax if you reside in one of the states listed .
California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, 
Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, 
Virginia, Wisconsin

  TOTAL ORDER 

$

  SHIPPING & HANDLING 

$    5 .00

  STATE SALES TAX 

$

  GRAND TOTAL  

$

Pas d’expédition contre remboursement . Veuillez inclure un chèque 

ou un  mandat bancaire, le payable fait à The Genie Company . 

N’envoyez pas d’argent comptant . Accordez de 3 à 4 semaines 

pour la livraison . 1-800-354-3643 . Ayez sous la main le numéro de la 

pièce et celui de la carte de crédit . Mettre à la poste le arrngement 

à: Genie Company, 22790 Lake Park Blvd, Alliance, Ohio 44601 . Nous 

acceptons les commandes par téléphone avec paiement par carte 

de crédit Visa ou Mastercard . 

Veuillez indiquer les taxes de vente locales si vous résidez dans l’un des états 
répertoriés ci-dessous .

  COMMANDE TOTALE 

$

  MANUTENTION ET EXPÉDITION 

$    5 .00

  TAXE DE VENTE 

$

  TOTAL GLOBAL

 

$

No se aceptan pedidos de pago contra entrega (COD) . 

Sírvase incluir su cheque o giro postal, la cuenta pagadera 

hecha aThe Genie Company . No envíe dinero en efectivo . 

Concédanos 3 a 4 semanas para la entrega . 1-800-354-3643 . 

Sírvase tener listos los números del modelo y de la tarjeta 

de crédito . Enviar hacer un pedido de mercancia a: Genie 

Company, 22790 Lake Park Blvd, Alliance, Ohio 44601 .

Aceptamos pedidos telefónicos de Visa o Mastercard .

Sírvase agregar el impuesto de ventas local si usted reside en uno de los 
 siguientes estados:

Ordering Instructions

Las Instrucciones que Ordenan

Instructions Commandant

(GI CT390-1) 

1-Button Compact Remote - Allows remote operation of garage door . 

 

Comprima el Mando de Distancia - Proporciónar operación remoto de la puerta del garaje . 

Télécommande compacte - Permettre opération éloign´´de porte de garage .

(GI CT390-3)

 3-Button Compact Remote -  Allows remote operation of 3 garage doors . 

 

 

De 3 botones Comprima el Mando de Distancia - Proporciónar operación remoto de tres las puertas del garaje . 

3-boutenner la Télécommande compacte  - Permettre opération éloign´ trois portes  

 

de garage .

(GWKPD)

 Wireless Keypad - Operates Intellicode

®

 Garage Door Openers without Remote Control or key . 

 

 

Sistema de entrada por teclado numérico inalámbrico - Acciona los abridores de puertas de garaje Intellicode

®

 sin  

 

control remoto o llave . 

 

 

 

 

 

 

 

Système d’ouvre-porte de garage à clavier sans fil - Actionne les ouvre-porte de garage avec Intellicode

®

 sans     

 

télécommande ni clé .

(GLU-3)

  3/4 oz.  Screw Drive Lubricant  - Ensures proper equipment wear protection .

3/4 once Lubricante de tornillo accionar  - Asegura componente correcto protección por deterioro .
La onza 3/4 Lubricant de la vis  - Garantir componant exact par systéme défense vers user .

(GW-2)

 Universal Wall Button - Provides additional convenient inside operation of door .

Botón de pared universal - Proporciona operación conveniente de la puerta desde el interior .
Bouton mural universel - Actionne l’ouvre-porte de l’intérieur du garage .

(GPS-5)

 Perfect Stop

®

 - Ensures perfect parking .

Stop Perfecto

®

 - Asegura el estacionamiento perfecto .

Butoir Perfect Stop

®

 - Permet de stationner à la perfection dans le garage .

 (LCGX-8)

 ChainLift Extension Kit - An Extension that increases the  travel of an Opener to accommodate an 

eight foot door .
 Juego de extensión de cadena deslizable - Una extensión para aumentar la longitud de la baranda de Chain 

Glide, para acomodar una puerta de 8 pies (2,43 m) .
Nécessaire de prolongement du coulisseau - Rallonge de prolongeant la course de l’ouvre-porte Chain Glide 

pour une porte de 2,4 m (8 pi) de hauteur .

(60 WATT

) Enhanced/Rough Service Light Bulb - Ensures proper equipment compatability .

Bombilla de 60 Vatios - Asegura componente correcto de sistema .
éclairage de 60 WATT - Garantir componant exact par systéme .

(GER-2)

 Emergency Release Kit - Provides access to garage from outside in the event of 

an electrical power failure . 

Juego de pica-porte de pestillo - Permitir entrtada desde por fuera de garaje porque corte 

de eléctrico . 

Nécessaires de Déclenchement de secours - Le nécessaire de déclenchement  

 

de secours est conçupour vous permettre d’accéder à votre garage depuis  

 

l’extérieur en cas de panne de courant et lorsqu’il .

STB

 Adapter Brackets (2) - Used in conjunction with standard STB Brackets . They provide  

 

additional clearance and mounting options .
El adaptador pone entre paréntesis (2) - Usado en unión con paréntesis uniformes de  

 

montar de STB, ellos proporcionan el espacio libre adicional junto con mortar las opciones .  

 

Crochets d’adaptateur (2) - Utilisé conjointement avec STB standard monter les crochets,  

 

ils fournissent le dégagement supplémentaire avec monter d’options .

(GSX-8)

 DirectLift Extension Kit - An Extension to increase travel of  an Operator to accommodate   

eight foot door .
Juego de extensión deslizante de Screw Drive - Una extensión para aumentar la carrera de un abridor  

deslizable, para acomodar una puerta de 8 pies (2,43 m .) .
Nécessaire de rallonge du Screw Drive - Rallonge de prolongeant la  

coursede l’ouvre-porte pour une porte de 2,4 m (8 pi) de hauteur .(GIRU-1T)  

 SHIP ORDER TO:
 ENVIAR MERCANCIA CON:
 EXPÉDIER MARCHANDISE POUR:

 NAME / NOMBRE / NOM

 ADDRESS / DIRECCIóN / ADRESSE

 CITY / CIUDAD / VILLE 

 STATE / ESTADO / ÉTAT                

 ZIP / CóDIGO POSTAL / CODE POSTAL

California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, 
Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, 
Virginia, Wisconsin

California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, 
Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, 
Virginia, Wisconsin

How many?

¿Quántos?

$36.50

$50.00

$35.00

$50.00

$5.00

$3.75

$4.00

$32.00

$32.00

$2.73

$20.00

$4.37

P/N 36248R

P/N 36223R

P/N 35661R

P/N 35691R

P/N 35218A.S

P/N 35693R

P/N 35677R

P/N 35679R

P/N 35678R

(GWC-2W)

 Deluxe Wall Console  - Operates Garage Door . Independent light control . Security vacation lock .   

Consola de lujo de pared - Acciona la puerta del garaje . Control de luz independiente . Cerradura de  

 

seguridad para vacaciones .  

 

 

 

 

 

 

La Console dse luxe de Mur - Actionne la porte de garage . Commande  d’éclairage  indépendante .    

 

Interrupteur de verrouillage de sécurité .

P/N 26210A.S

P/N 35675R

 

(Prices subject to change without notice)

 

(Valoran el cambio con sujeción a sin nota)

 

(Les prix assujettissent pour changer sans la notification)

P/N 34439R.S

 (GABX8)

 QuietLift Extension Kit - An Extension that increases the  travel of an Opener to accommodate an 

eight foot door .
 Juego de extensión de cadena deslizable - Una extensión para aumentar la longitud de la baranda de Chain 

Glide, para acomodar una puerta de 8 pies (2,43 m) .
Nécessaire de prolongement du coulisseau - Rallonge de prolongeant la course de l’ouvre-porte Chain Glide 

pour une porte de 2,4 m (8 pi) de hauteur .

$32.00

P/N 35663R

Garage Door Opener Accessories Order Form

Formulario de pedido de accesorios para abridores de puertas de garaje 

Formulaire de commande des accessoires pour ouvre-porte de garage

For additional accessories not shown . visit our website at www .geniecompany .com

Para accesorios adicionalesno mostrada, visite nuestro sitio web en www .geniecompany .com

pour les accessoires supplémentaires pas montré, visiter notré site web à www .geniecompany .com

  TOTAL DEL PEDIDO 

$

  FLETE Y MANEJO 

$    5 .00

  IMPUESTO DE VENTAS ESTATAL 

$

  GRAN TOTAL 

 

$

$45.00

P/N 35657R

(GI F  TD-1)

 1-Button Flashlight Transmitter  -  Remote Controller with a Flashlight . 

1 abrocha transmisor de linterna - Director remoto con una linterna . 

1-boutenner l’émetteur de lampe de poche  - Le contrôleur éloigné avec de lampe de poche .