INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

IMPORTANT INSTRUCTIONS

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Fireplace System Blower

MODEL #: GFB100

Compatible Fireplace Systems:

VFF-PH(20D)(20DB)(20D-C)(CPD-2T)

VFF-PH(26D)(26D-T)(IMD-2H)

VFF-PH(32DR)(32DR-H)(FSDR-2C) 

IMGFB - 2015-04-06

WARNING: 

IF THE INFORMATION IN THIS MANUAL IS NOT FOL-

LOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING 
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

WARNING: 

THIS PRODUCT IS ONLY FOR USE WITH MODELS SPECI-

FIED IN THIS MANUAL BY THE MANFACTURER. ANY OTHER USAGE OR 
INSTALLATION NOT SPECIFIED IN THIS MANUAL IS PROHIBITED.

Questions, problems, missing parts?

 Before returning to your retailer, call 

our customer service department at 1-877-447-4768,

 

8:30 a.m. –  4:30

 

p.m., 

CST, Monday – Friday or email us at customerservice@ghpgroupinc.com.

 


background image

 


background image

2

      WARNING: This appliance is equipped with a three-prong (grounding) plug for 

your protection against shock hazard and must be plugged directly into a properly 

grounded three-prong receptacle.

1.  Read all instructions before using this appliance.
2.  If possible always unplug this appliance when not in use.
3.  Do not operate any heater with a damaged cord or plug or after the appli-

ance malfunctions, has been dropped or damaged in any manner.

4.  Under no circumstances should this appliance be modified. Parts having to 

be removed for servicing must be replaced prior to operating this appliance 

again.

5.  Do not use outdoors.
6.  This heater is not intended for use in bathrooms, laundry areas and similar 

indoor locations. Never locate this appliance where it may fall into a bath-

tub or other water container.

7.  Do not run cord under carpeting. Do not cover cord with throw rugs, run-

ners or the like. Arrange cord away from traffic areas and where it will not 

be tripped over.

8.  To disconnect this appliance, turn controls to the off position, then remove 

plug from outlet.

9.  Connect to properly grounded outlets only.
10.  This appliance, when installed must be electrically grounded in accordance 

with local codes, with the current USA installations, or in the absence of lo-

cal codes, the National Electric Code, ANSI/NFPA No. 70.

11.  Do not insert or allow foreign objects to enter any ventilation or exhaust 

opening as this may cause an electric shock, fire or damage the appliance.

12.  To prevent possible fire, do not block air intakes or exhaust in any manner.
13.  Use this appliance only as described in this manual. Any other use not 

recommended by the manufacturer may cause fire, electric shock or injury 

to persons.

14.  Installation and repair should be done by a qualified service person. The 

appliance should be inspected before use and at least annually by a pro-

fessional service person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding material, etc. It is imperative that 

control compartments, burners and circulating air passageways of the ap-

pliance be kept clean.

SAFETY INFORMATION                                      SAVE THESE INSTRUCTIONS 

 

 


background image

3

PACKAGE CONTENTS

  REF # 

PART # 

DESCRIPTION 

QUANTITY

 

A  

XB001-01  

Power Cord  

1

 

XB002-01Q  

Blower  

1

 

C  

XB003-01  

Temperature Sensor  

1

 

D  

XB004-01Q  

Connect Wire  

1

 

E  

PF06-0400-A  

Rocker Switch  

1

 

F  

M4.2×8  

Screw  

10

 

G  

VL057-03  

Cable Tie  

2

Parts List

Before beginning assembly of product, make sure all parts are present. Compare 

parts with package contents list and diagram under. If any part is missing or dam-

aged, do not attempt to assemble, install or operate the product. Contact our

Technical Service Department at 1-814-643-1775.

A

C

B

D

E

F

G

• A Phillips head screwdriver is needed for installation.

 


background image

4

ASSEMBLY INSTRUCTIONS

1.  

Remove Blower Access Panel.

FF

2.  

Mount Blower (B) onto bottom of   

 

Fireplace Top using 4 screws (F).

3.  

Attach Power Cord (A) to Blower  

 

Access Panel.

4.  

Attach Temperature Sensor (C) to 

           the Combustion Top using 2 sheet 
 

metal screws.

1

2

3

Access Panel

Screws

Power Cord

Access Panel

WARNING:

 This appliance is equipped with a three-prong (grounding) plug 

for your protection against shock hazard and must be plugged directly into a 

properly grounded three-prong receptacle. 

Firebox must be disconnected from gas supply and removed from mantel 

before installing fan accessory. Contact a qualified service person to do this.

BLOWER INSTALLATION (OPTIONAL)

4

Sheet 

Metal 

Screws

Senser 

Bracket

Combustion Top 

Mounting Holes

 


background image

5

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

5.  

Important: Insert the wires marked 

 

with AUTO, OFF and MAN into line 

 

slot on the right corner. Keep wires 

 

close to the bottom.

5

6.  

Insert two wires’ female plugs 

 

marked with T1 and T2 (black and 

 

yellow) into two male ports on 

 

Temperature Sensor.

7.  

Insert the female plug on the white 

 

power supply wire (marked with 

 

P1), into the corresponding male 

 

port (marked with P1).

6

7

8.  

Insert the female plug (marked 

 

with P2) into the corresponding 

 

male port, which is on the black 

 

power supply wire (marked 

 

with P2).

8

 


background image

6

ASSEMBLY INSTRUCTIONS

9.  

Insert the blower link (male plug) 

 

into the power link (female port).

9

10.  

Important

: Bind wires with cable 

 

ties (G), and attach cable ties (G) 

 

in holes on back of Outer Casing. 

 

Attach one in hole near the top and  

 

one in hole near the bottom.

10

11.  

Insert AUTO, OFF, MAN wires 

 

through the Rocker Switch 

 opening.

11

12

Fixed

Hole

G

E

12.   Connect AUTO, OFF, MAN wires
 

to the three corresponding male 

 

ports on the Rocker Switch (E). 

 

Match the "Auto" wire to the 

 

symbol "     " and the "Man" wire 

 

to the symbol "     " on the rocker 

 

switch (E).

 


background image

7

ASSEMBLY INSTRUCTIONS 

ASSEMBLY INSTRUCTIONS

13.   Push Rocker Switch (E) into 
 

Control Panel and secure.

13

14.   Check that all wires are secure 
 

and reattach Blower Access Panel 

 

to Outer Casing. Capture the 

 

Green Ground wire between the 

 

Access Plate and Outer Casing 

 

with the upper right screw.

E

1

1

2

2

3

3

4

4

A

A

B

B

C

C

D

D

SHEET

 1  

OF

 1 

DRAWN

CHECKED

QA

MFG

APPROVED

dandowning

4/12/2013

DWG NO

Power Cord Attachment

TITLE

SIZE

C

SCALE

REV

Green Ground

Wire

14

Screw

Outer 

Casing

Access Panel

Power Cord

 


background image

8

OPERATING INSTRUCTIONS

Using Rocker Switch, turn blower on and check for operation. Turn on Rocker 
Switch to the desired position. In the MAN position it will remain constantly on. 
AUTO position will be controlled by the Temperature Sensor. To stop the opera-
tion turn Rocker Switch to the OFF position.

t

WHITE

GREEN

BLUE

BLACK

BLA

CK

AUTO OFF MAN

1

2

3

4

5

~120V

60Hz

1. Power Cord

2. Bushing Strain Relief

3. Blower

4. Temperature Sensor

5. Rocker Switch

FAN

Electrical Wiring Diagram

NOTE: If any of the original wire as supplied with the appliance must be replaced, it 

must be replaced with a wire of at least an equal temperature rating.
       CAUTION: Label all wires prior to disconnection when servicing controls. 

Wiring errors can cause improper and dangerous operation. Verify proper operation 

after servicing.

 


background image

9

MAINTENANCE OF MOTORS

Always disconnect the appliance from the main power supply and allow it to 
cool before any servicing operation. The motor used on the flame blower is pre-
lubricated for extended bearing life and requires no further lubrication. However, 
periodic cleaning/vacuuming of the appliance around the air intake and exhaust, 
as well as the blower is recommended. For heavy or continuous use, periodic 
cleaning must be done more frequently. If the heater blows alternating cold and 
warm air, check the blower for free movement and for debris restricting air flow. 
If the blower does not move freely, the unit must be turned off and the blower 
replaced immediately in order to prevent further damage to the unit.

       WARNING

: Make sure all power to the appliance is turned OFF 

before proceeding.

Printed in China

Troubleshooting

PROBLEM 

POSSIBLE CAUSE 

CORRECTIVE ACTION

Blower is not 

spinning.

Blower is mak-

ing a loud noise.

1. There is no power to 

the blower.

2. Blower is set to 

    AUTO "     ".

3. Blower motor is bad.

1. Blower housing or 

    blades are dirty.

2. Blower rotation is  

    blocked.

3. Defective blower.

1. Clean blower and blower 

    housing.

2. Verify wiring is not in blower 

     path.

3. Replace blower.

1. Verify blower is plugged in and  

    set  to MAN "    " or 

    AUTO "     ".

2. Allow 5-10 minutes for blower

    to engage.

3. Replace blower.

 


background image

10

33

This limited warranty is extended to the original retail purchaser of this heater and warrants against any

2

2

two

two

years

years

 


background image

11

34

GHP Group, Inc.

6440 W Howard St

Niles, IL 60714-3302

Tel: (877) 447-4768

www.ghpgroupinc.com

GHP Group, Inc.

6440 W Howard St

Niles, IL 60714-3302