Safety and Installation Manual

  

 

Introduction 

This  manual  provides  safety  and  installation  instructions  for  GH  Solar  photovoltaic  (PV)  modules.    Carefully 
read the entire instruction manual before installing, wiring or operating the PV modules.  Save this 

GH  Solar

 

Safety and Installation Manual at all times. 

Disclaimer of Liability 

Failure  to  follow  these  instructions  will  invalidate  the 

GH  Solar

  Limited  Warranty  for  PV  modules.  The 

conditions  and  methods  of  installation,  operation,  use  and  maintenance  of  the  PV  modules  is  beyond 
company  control.   

GH  Solar

  is  thus  not  liable  for  any  damage  or  loss  caused  by  improper  use  or  incorrect 

installation, operation, use or maintenance. 
 
Module limited warranties are described in 

GH Solar

 warranty certificates. 

 

Safety Instructions prerequisites 

 

The installation should be done by qualified personnel only. 

 

Make sure to remove all jewellery from your hands and wrists before installing this product.  

 

PV Modules generate direct current (DC) when exposed to any amount of light. Direct current can arc 
when improperly connected or disconnected in a connected string of modules, and may cause injury 
or death. 

 

Do not connect or disconnect a PV module when current might flow through one of the modules, the 
main grid, or an external source. 

 

Make sure that the cable connections are in perfect condition and are not deformed in any way. 

 

Do not insert any electrically conducting part into one of the connectors. 

 

Do not install or connect modules when the module or one of its components, are wet. 

 

Do not install visually damaged modules (e.g. broken glass, broken junction box, broken connectors).  
Immediately contact 

GH Solar

 for disposal or replacement instructions.  

 

Do not disassemble or remove any part of the module. Do not attempt to repair any part of the module 
either. 

 

Ensure that the modules are used for their  intended  purpose only.   All installations must be done in 
accordance with regional regulations and policies. 

 

Keep away from children. 

Storing and unpacking instructions 

Modules should be unpacked  in a  dry  environment only.  Avoid  any direct contact  with rain or  other types  of 
moisture.  Leave  the  modules  packed  until  right  before  installation.  Modules  must  be  stored  in  their  original 
packing  a  dry  and  ventilated  place. While  unpacking,  make sure  the  modules  are  not  exposed  to  any  direct 
light source. 

Preparation before installation 

Always perform a visual inspection of the packaging material before unpacking. After unpacking the module, 
make sure that no irregularities or deformities are present on the panel or one of its components. Measure the 
Voc  of  every  module  while  exposed  to  direct  sunlight  (irradiance  >600W/m²),  and  make  sure  the  measured 
Voc  value does not equal  or approach  zero  Volts. If  any  of these requirements is not met, do not  install the 
module, and immediately contact 

GH Solar


background image

May 2011.  All rights reserved.  Specifications included in this manual are subject to change without prior notice                                               .

Page 

2

 of 

7

 

 

Installation and Operation 

During installation of the modules, following guidelines should be taken into account: 

 

Installation should be executed by qualified personnel only. 

 

Solely use insulated  and dry tools.  

 

Ensure that any other components used in the project are compatible with the modules. 

 

Do  not  apply  excessive  pressure  or  step  on  the  modules.  Be  aware  that  sharp  edged  objects  can 
inflict permanent damage to the module. 

 

Make  sure  the  used  support  structure  meets  the  maximal  load  requirements  of  the  modules.  In 
regions with high possibility of snow or strong wind, always make sure that the support structure and 
its mounting design are able to withstand the local environmental forces.  

 

Do not install modules during periods of strong wind or other unusual weather conditions. 

 

To  reduce  the  risk  of  electrical  shock  or  burns  while  installing  the  module,  it  is  advised  to  cover  the 
module with an opaque cloth in order to keep the module in its inactive state. 

 

Do not expose the modules to concentrated light,  excessive water exposure or submerging, sources 
of corrosive chemicals or salty environments. 

 

Provide  adequate  ventilation  to  the  back  side  of  the  modules  to  avoid  heating  of  the  module. 
Insufficient  ventilation  may  cause  significant  yield  losses,  and  eventually  cause    permanent  damage 
to the module. 

 

Always minimize shade caused by obstacles near the PV system.  Shade will dramatically affect and 
reduce  the  global  PV  system  performance,  and  may  eventually  cause  permanent  damage  to  the 
module. 

 

When installed on a roof, the roof covering should be rated for fire-resistant capabilities. Do not install 
modules on locations where flammable gas may be present at some point in time. 

 

It  is  recommended  to  position  the  module  in  a  gradient  angle  facing  the  sun  in  order  to  ensure 
maximum  irradiation  and  to  avoid  damage  caused  by  flooding  and  other  unpredictable  events,  such 
as heavy hail impacts. 

Mounting instructions 

Modules can be mounted in portrait or in landscape. Use appropriate corrosion proof fastening materials. 

Framed module mounting instructions 

 

Each module must be securely fastened, using at least 4 symmetrically chosen contact points. 

Modules  can  be  mounted  using  mounting  holes,  if  any,  or  using  pressure  clamps  that  compress  the  frame 
from the top to the mounting rail. Four M6 (1/4”) stainless steel bolts, with nuts, washers, and lock washers 
are recommended per module for long-term security. 

When  using  pressure  clamps,  mount  the  clamps  in  accordance  to  the  environmental  forces  the  module  is 
exposed to. The clamping area of the washer must cover at least 130 mm². Use a torque wrench and tighten 
at 20 Nm.  

Always respect the mounting parameters and tolerances for each module type, as shown below. 

 

 


background image

May 2011.  All rights reserved.  Specifications included in this manual are subject to change without prior notice                                               .

Page 

3

 of 

7

 

 

Module Type: 6x12 5inch cells -- typical dimensions: 1580x808x35mm 

Product types: GH175M125, GH180M125, GH185M125, GH190M125, GH195M125, GH200M125 

Mounting on long sides 

Mounting on short sides 

 
 

 

 

 

 

 

 


background image

May 2011.  All rights reserved.  Specifications included in this manual are subject to change without prior notice                                               .

Page 

4

 of 

7

 

 

Module Type: 8x12 5 inch cells -- typical dimensions: 1580x1064x46mm 

Product types: GH235M125, GH240M125, GH245M125, GH255M125, GH260M125, GH260M125 

 

M

o

u

n

ti

n

g

 o

n

 s

h

o

rt 

si

d

e

s

 

 

 

M

o

u

n

ti

n

g

 o

n

 l

o

n

g

 sid

e

s

 

 

 

 


background image

May 2011.  All rights reserved.  Specifications included in this manual are subject to change without prior notice                                               .

Page 

5

 of 

7

 

 

Module Type: 6x10 6 inch cells -- typical dimensions: 1640x992x46mm 

Product types: GH235P156, GH240P156, GH240M156, GH250M156, GH255M156 

 

M

o

u

n

ti

n

g

 o

n

 s

h

o

rt 

si

d

e

s

 

 

 

M

o

u

n

ti

n

g

 o

n

 l

o

n

g

 sid

e

s

 


background image

May 2011.  All rights reserved.  Specifications included in this manual are subject to change without prior notice                                               .

Page 

6

 of 

7

 

 

Frameless module mounting instructions 

 

Mounting  clamps  or  insertion  rails  can  be  used  for  mounting  the  module.  When  using  clamps,  at  least  2 
clamps  per  module  side  should  be  used.  For  modules  with  an  extended  width  (>800mm),  3  clamps  per 
module side must be used. The clamp area must be at least 70mm per clamp.  

Clamps  or  insertion  rails  must  be  equipped  with  rubber  to  protect  the  module  against  shock  and  dilation  of 
system components. Direct contact between the back side, the front side or the edge of the module and the 
mounting clamps or insertion rail must be avoided at all times. 

Only use mechanical fixtures for mounting the modules. Do not use adhesives or adhesive tapes for fastening 
the laminates, unless they have been explicitly approved by 

GH Solar

.  

 
Please note that the module edges are particularly sensitive to impact. When mounted in harsh environment 
conditions, supplementary protection on each side of the module should be provided. 

Mounting the modules in excessive environmental temperatures should be avoided at all times. Dilation of all 
system  materials  should  be  carefully  considered  prior  to  mounting  the  modules. 

GH  Solar

  cannot  be  held 

responsible in case of module breakage due to dilation of system components. 

In case of any doubt regarding the mounting system, 

GH Solar

 should be contacted. 

Table: module mounting instructions per module type 

 

# of 
clamps 

Typical GH Solar 
products 

Long side mounting  
and tolerance 

Short side mounting  and 
tolerance 

6x12 5inch cells 
 framed module 

GH175M125, 
GH180M125, 
GH185M125, 
GH190M125, 
GH195M125, 
GH200M125 

(260 +/-50)mm 

(180 +/-20)mm 

8x12 5inch cells  
framed module 

GH235M125, 
GH240M125, 
GH245M125, 
GH255M125, 
GH260M125, 
GH260M125 

(310 +/-50)mm 

(180 +/-20)mm 

6x10 6inch cells  
framed module 

GH235P156, 
GH240P156, 
GH240M156, 
GH250M156, 
GH255M156 

(310 +/-50)mm 

(180 +/-20)mm 

 

Wiring 

 

The  desired  electrical  output  can  be  obtained  by  connecting  modules  in  series  and/or  in  parallel. 
Make  sure  that  the  maximum  system  voltage  is  not  exceeded.  Limits  of  both  junction  box  voltage 
rating  and  maximal  DC  input  voltage  of  the  inverter  (or  other  appliance)  should  be  respected  at  all 
times. Exceeding these limits will inflict irreversible damage to the whole PV system. 

 

PV  modules  connected  in  series  should  have  similar  current.    PV  modules  connected  in  parallel 
should have similar voltage.   

 

Please note that all electrical module parameters are defined under Standard Test Conditions (STC) 
of  1.000  W/m²  irradiance  with  AM  1.5  spectrum  and  a  cell  temperature  of  25°C.    Modules  may 
produce more or less voltage and/or current than reported at STC.  Accordingly, the values of Isc and 


background image

May 2011.  All rights reserved.  Specifications included in this manual are subject to change without prior notice                                               .

Page 

7

 of 

7

 

 

Voc marked on the module should be multiplied by a factor of 1.25 when determining voltage ratings, 
conductor current ratings, fuse sizes, and size of other system components. 

 

Always respect the polarity of the connectors when stringing modules, and make sure the connectors 
are tightly connected.  Do not install or wire modules when the connectors are wet. 

 

Grounding 

 

Grounding  of  the  modules  needs  to  be  done  in  accordance  with  the  applicable  regional  regulations  about 
grounding PV arrays and mounting frames. 

 

Maintenance 
 

 

Screw  tightness  and  corrosion  at  the  mounting  points,  as  well  as  wiring  connectivity  should  be 
regularly inspected. 

 

Periodic  cleaning  of  modules  is  recommended,  but  is  not  required.    Rainfall  will  give  the  module  its 
self-cleaning  capabilities.  Please  not  that  GH  Solar  is  not  responsible  for  any  yield  losses  due  to 
pollution on the panel, caused by a too small slope. 

 

Modules  may  be  cleaned  by  potable,  non-heated  water.    Normal  water  pressure  is  sufficient.  No 
cleaning products are to be used and heavily sticking impurities are to be removed by a soft cleaning 
tool  like  a  sponge  or  cleaning  cloth.    Use  of  cleaning  chemicals  or  sharp  instruments  to  clean  the 
modules will damage the module, and therefore invalidate the product warranty.