PDF User Manual

  1. Home
  2. Manuals
  3. GESTRA NRS 2-4 Installation Instructions Manual

GESTRA NRS 2-4 Installation Instructions Manual

Made by: GESTRA
Type: Installation Instructions
Category: Switch
Pages: 16
Size: 0.11 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

1

E N

E n g l i s h

Level Switch

NRS 2-4

Original Installation Instructions

810427-03

 


background image

2

Contents

Usage for the intended purpose  .............................................................................................................4

Safety note .............................................................................................................................................4

Danger ...................................................................................................................................................4

Attention .................................................................................................................................................4

LV (Low Voltage) Directive and EMC (Electromagnetic Compatibility) .......................................................4

ATEX (Atmosphère Explosible) .................................................................................................................4

Important Notes

Page

Explanatory Notes

Scope of supply ......................................................................................................................................5

Description .............................................................................................................................................5

Function .................................................................................................................................................5

Design ....................................................................................................................................................5

NRS 2-4c ................................................................................................................................................9

NRS 2-4d ................................................................................................................................................9

Tools .......................................................................................................................................................9

Installation

Electrical Connection

NRS 2-4................................................................................................................................................10

Wiring diagram .....................................................................................................................................10

Key .......................................................................................................................................................11

Attention ...............................................................................................................................................11

Note .....................................................................................................................................................11

Tools .....................................................................................................................................................11

NRS 2-4..................................................................................................................................................6

Dimensions .............................................................................................................................................7

Technical Data

NRS 2-4..................................................................................................................................................8

Key .........................................................................................................................................................8

Functional Elements

 


background image

3

Contents

   – continued –         

          

Page

Commissioning Procedure

Checking electrical connection .............................................................................................................12

Applying mains voltage .........................................................................................................................12

Danger .................................................................................................................................................12

Performance test ..................................................................................................................................12

Table 1 .................................................................................................................................................12

Operational Malfunctions

Danger .................................................................................................................................................13

Fault finding list for troubleshooting ......................................................................................................13

Annex

Note on the Declaration of Conformity / Declaration by the Manufacturer CE .........................................14

 


background image

4

Important Notes

Danger

The terminal strip of the NRS 2-4 is live during operation. 

This presents the danger of electric shock!
Cut off power supply before inserting or removing the 19" slide-in unit and before carrying 

out any installation or maintenance work.

Usage for the intended purpose

The level switch NRS 2-4 is used in conjunction with level electrode NRG 211 and signals a maximum 

admissible liquid level. 

Safety note

The level switch is a safety device and must only be installed, wired and commissioned by qualified and 

competent staff.
Retrofitting and maintenance work must only be performed by qualified staff who – through adequate 

training – have achieved a recognised level of competence.

Attention

The name plate specifies the technical features of the equipment. Note that any piece of 

equipment without its specific name plate must neither be commissioned nor operated.

LV (Low Voltage) Directive and EMC (Electromagnetic Compatibility)

The level switch NRS 2-4 meets the requirements of the Low Voltage Directive 2014/35/EC and the 

EMC Directive 2014/30/EC.

ATEX (Atmosphère Explosible)

According to the European Directive 2014/34/EC the level switch NRS 2-4 must 

not 

be used in 

 potentially explosive areas. 

 


background image

5

Description

The level switch NRS 2-4 is an analogue electronic amplifier for the capacitance electrode NRG 211.
In conjunction with the electrode NRG 211 it can detect high water level.  

In addition, the level switch detects possible malfunction signals coming from the electrode and 

 monitors the electrode supply cable. 

Design

NRS 2-4c:  

19 slide-in unit with guide rails and 32 pole screw-type connector for installation in 19 magazine to DIN 

41494, part 5. Front panel to DIN 41494, part 5, 6 division units*).

NRS 2-4d:  

Spare 19 slide-in unit, front panel to DIN 41494, part 5, 6 division units.

Function

The NRS 2-4 is a single-channel device equipped with a power supply unit and a voltage detector. The 

feed voltage (12 V DC) for the electrode is – depending on the operating condition – converted into a 

measuring voltage. The signal decoder allocates the measuring voltage to an operating condition which 

is indicated by the LEDs on the front panel of the NRS 2-4.
The level switch can signal the following four operating conditions:

n

  Normal operation 

n

  High level alarm

n

  Malfunction in level electrode

n

  Malfunction in connecting cable

In the event of a high level alarm or malfunction the corresponding output relay will be triggered.  

In addition to the output relays optocouplers are also available for switching.

Explanatory Notes

Scope of supply

NRS 2-4c 

1 Level switch designed as 19" slide-in unit, front panel to  DIN 41494, part 5, 6 division units*) 

2 Guide rails 

1 Screw-type connector 

1 Installation manual

NRS 2-4d 

1 Level switch designed as 19 slide-in unit, front panel to DIN 41494, part 5, 6 division units*) 

1 Installation manual

*) 1 division unit = 5.08 mm

 


background image

6

NRS 2-4

Input measuring circuit

 

1 V to 10 V DC (measuring voltage coming from level electrode)

Output measuring circuit

 

12 V DC (supply voltage for level electrode)

Output 

2 volt-free relay contacts. Max. contact rating with switching voltages of 

24 V, 115 V and 230 V AC: resistive 4 A, inductive 0.75 A at cos 

j

 0.5. 

Max. contact rating with switching voltage 24 V DC: 4 A. Contact material silver, hard gold plated. 

2 optocouplers (NPN), short-circuit protected due to current limiting, max. 70 V, 10 mA

Indicators and adjustors 

1 LED for “Alarm”, 2 LEDs for “Malfunction”, 1 LED for “Power”

Mains voltage 

18 - 36 V DC

Power consumption 

2 VA

Housing material 

NRS 2-4c: Front panel: aluminium 

NRS 2-4d: Front panel: aluminium

Weight 

NRS 2-4c/d: aprox. 0.6 kg

Technical Data

 


background image

7

Fig. 1 

Technical Data

   – continued –

Dimensions

169

128.5

30.48 

 (6 division 

units)

 


background image

8

Functional Elements

NRS 2-4

Fig. 2

A

C
B

E
D

F

A

  32-pole screw-type connector, DIN 41612, design D

B

  LED “Power”

C

  LED “Malfunction in connecting line”

C

  LED “Malfunction in level electrode”

E

  LED “High level alarm”

F

  Fixing screws

Key

 


background image

9

Installation

NRS 2-4 c

1.  Mount plastic guide rails in 19 magazine.
2.  Install screw-type connector.
3.  Insert level switch in 19 magazine and fix it with screws 

F

.

Tools

n

  Screwdriver 5.5/100

NRS 2-4 d

1.  Insert level switch in 19 magazine and fix it with screws 

F

.

 


background image

10

Electrical Connection

NRS 2-4

Note that screened four-core cable, e. g. I-Y(St)Y 2 x 2 x 0.8 or LIYCY 4 x 0.52  is required for wiring. 

Max. length: 500 m.
Wire screw-type connector according to the wiring diagram. 

Fig. 3

Wiring diagram

Fig. 3

3

2

1

NRG 211

C28

A30

A24

A28

C30

C24

DC

DC

24V DC

12V DC

M

C

16

C

18

A

18

NRS 2-4

A22

A20

C 8

A 2

C 12

C 4

A 10

A 6

C22

C20

MAX

2

3

4

5

6

1

3

2

1

12V DC

12V DC

M

M

C

16

C

16

C

18

C

18

A

18

A

18

NRG 211

NRS 2-4

NRS 2-4

7

1

7

1

2

3

4

5

6

1

 


background image

11

To protect the switching contacts fuse circuit with 2.5 A (slow-blow) or according to 

TRD regulations (1.0 A for 72 h operation).

n

  The screen must not make any other electrical contact

Attention

Electrical Connection

   – continued –

Level electrode NRG 211

Test loop for equipment

Switching output for “Alarm” (optocoupler)

Switching output for “Malfunction” (optocoupler)

Switching output for “Alarm” (relay)

Switching output for “Malfunction” (relay)

Wiring diagram for two high-level switches installed in parallel (redundancy)

Key

Note

n

  Connect screen only to terminal A18 of the level switch. 

n

  The monitoring of the level electrode and the connecting lines can be included in the 

safety circuit. For this purpose the safety circuit must also be fed to the relay output 

“Malfunction”.

n

  The rated voltage is indicated on the name plate.

n

  When switching off inductive loads, voltage spikes are produced that may impair the 

operation of control and measuring systems. Inductive loads should be provided with 

commercial arc suppressor RC combinations, e. g. 0.1 μF/100 Ω.

Tools

n

  Screwdriver for slotted screws, size 2.5, completely insulated according to VDE 0680

 


background image

12

Apply mains voltage. The green LED 

B

 is illuminated. 

Fig. 2

Commissioning Procedure

Make sure that the NRS 2-4 and the associated level electrode NRG 211 are wired in accordance with 

the wiring diagram. 

Fig. 3

Checking electrical connection

Applying mains voltage

NRS 2-4 c/d

1.  When switching on the mains voltage the green LED 

B

 must be permanently illuminated. 

Fig. 2

2.  Raise water level until it exceeds the high level mark. 

The red LED 

E

 of the level switch must light up.

3.  Lower water level until it falls below the high level mark. The red LED must go out.
4.  After detaching the connector from the level electrode the amber LED 

C

 must light up (malfunction 

in connecting line).

5.  After bridging the terminals C16 and C18 the amber LED 

D

 must light up (malfunction in equipment).

The measuring voltages for the operating conditions are listed in table 1.

Performance test

Table 1

Measuring voltage U

M

 

Decoding

≤ 1 V 

Malfunction in electrode supply cable (short circuit or interruption)

1 V – 4 V 

Electrode exposed, fluid temperature ≥ 395 °C

4 V – 7 V 

Electrode submerged, HIGH level

≥ 9 V 

Malfunction in electrode (defective insulating seal, leaky stuffing box)

Danger

The screw-type connector of the NRS 2-4 c/d is live during operation.

This presents the danger of electric shock!
Cut off power supply before inserting or removing the 19" slide-in unit and before carrying 

out any installation or maintenance work.

 

 


background image

13

Fault finding list for troubleshooting

Operational Malfunctions

Danger

The screw-type connector of the NRS 2-4 c/d is live during operation.

This presents the danger of electric shock!
Cut off power supply before inserting or removing the 19" slide-in unit and before carrying 

out any installation or maintenance work.

 

If faults occur that are not listed above or cannot be corrected, please contact our service centre or 

authorized agency in your country.

LED “Power” is not illuminated.

Fault:

  

Power failure

Remedy:

   Measure voltage across A/C 28 and A/C 30, check voltage supply and electric connection

LED “Malfunction in level electrode” and LED “High level alarm” are illuminated.

Fault:

  

The safety screw of the level electrode has not been removed

Remedy:

  Remove safety screw

Remedy:

    Level electrode (insulation, stuffing box) defective 

Remedy:

   Measure measuring voltage across C 18 / A 18 

Replace level electrode if measuring voltage 

 9 V

LED “Malfunction in connecting line” illuminated.

Fault:

 

Electrode supply line defective (short circuited or interrupted)

Remedy:

    Check electrode supply line and wiring

High water level is exceeded but only the green LED “Power” is illuminated.

Remedy:

    Level electrode not submerged

Remedy:

   Measure measuring voltage across C 18 / A 18 

If no voltage can be measured check and, if necessary, change installation of level electrode 

Fault:

  

Preamplifier in level electrode defective

Remedy:

  Replace preamplifier if the 12 V supply voltage for the electrode is present but no measuring 

voltage can be measured across C 16 / A 18

 


background image

14

Note on the Declaration of Conformity / Declaration by the Manufacturer   

Annex

For details on the conformity of our equipment according to the European Directives see our  

Declaration of Conformity or our Declaration of Manufacturer.
The current Declaration of Conformity / Declaration of Manufacturer are available in the Internet 
under www.gestra./de/documents or can be requested from us.

 


background image

15

For your notes

 


background image

16

810427-03/06-2016cm (808455-03) · GESTRA AG · Bremen · Printed in Germany

GESTRA AG

Münchener Straße 77 
28215 Bremen
Germany
Telefon  +49 421 3503-0  
Telefax   +49 421 3503-393
E-mail   info@de.gestra.com
Web www.gestra.de

Agencies all over the world: 

  

www.gestra.de