17

GB

Fully automatic blood pressure 

monitor for the upper arm

Instruction manual

GT-868UF

 


background image

18

GB

Information You Should Know 
Before Operating the Unit 

 ......................................   19

About the Unit 

  Explanation of Displays .........................................   21

Preparation for Use

  Installing/Replacing Batteries ................................   21
  Attaching the Pressure Cuff  ..................................   22
  Posture during Measurement ................................   23

Operations

  Setting the Time and Date  ....................................   24 
  Measuring Blood Pressure ....................................   24

Storing Data 

 Recalling 

Data 

.......................................................  

25

 Erasing 

Data 

..........................................................  

26

Care and Maintenance 

 ............................................   26

Speci

fi

 cations

  ..........................................................   28

Error Messages 

 .......................................................   29

Quality Standard 

 .....................................................   29

Caution

1. Consult your physician to verify your blood pressure 

range before measuring it at home with this unit.

2. If the cuff causes any discomfort during measurement, 

press the start/stop button to turn off the 

 unit 

immediately.

3. If the pressure is over 300mmHg and the cuff does not 

de

fl

 ate automatically, pull off the velcro strap to detach 

the arm cuff.

Blood pressure measurements obtained with this unit 

are equivalent to those obtained by a trained

person using the cuff/ stethoscope auscultation method.

Geratherm easy med is not intended for professional 
use.

WARRANTY:

 3 years from the date of purchase.

Contents

 


background image

19

GB

Information You Should Know Before 
Operating the Unit

What is blood pressure?

A force is created by the heart as the ventricle forcibly 
ejects blood into the blood vessels and through the vas-
cular system. Another force is created by the arteries as 

they resist the blood 

fl

 ow. Blood pressure is the result of 

these two forces.

Is my blood pressure normal?

See the following blood pressure classi

fi

 cation chart re-

leased by the WHO (World Health Organization) for eva-
luation of your blood pressure level.

Severe hypertension (Grade 3)

Moderate Hypertension (Grade 2)

Mild Hypertension (Grade 1)

Optimal

Normal

Boarderline

Classi

fi

 cation of 

blood pressure 
monitor

Systolic 

mmHg

Diastolic 

mmHg

Color 

indicator

Optimal 

< 120

< 80

green

Normal

120 - 129

80 - 84

green

High - Normal

130 - 139

85 - 89

yellow

Phase 1 
Hypertension

140 - 159

90 - 99

red

Phase 2 
Hypertension

160 - 179

100 - 109

red

Phase 3 Hyper-
tension 

>= 180

>= 110

red

 


background image

20

GB

LCD DISPLAY

SET BUTTON

RECALL MEMORY BUTTON

MODE BUTTON

START/STOP BUTTON

Cuff connection

ARM CUFF

(AA) 1,5 V x 4

Alkaline Batteries

What about low blood pressure?

In general, a lower blood pressure reading is better un-

less it causes unpleasant symptoms such as fainting and/

or lightheadedness.

What are systolic and diastolic pressures?

Systolic pressure is the highest pressure at the height of 
the heart’s contraction. Diastolic pressure is the lowest 
pressure when the heart is resting.

Fluctuation and variation in blood pressure 

The following factors will in

fl

 uence blood pressure measure-

ment results and cause variations.

Bathing, Breathing, Conversation, Drinking alcohol, 

Exercise, Moving, Mental tension, Eating, Temperature 

changes, Thoughts, Smoking etc.

About the unit

Information You Should Know Before Ope-
rating the Unit

The cuff is designed to 

fi

 t arm diameters between 

23 and 33 cm / 8.7 - 12.6 inches.

 


background image

21

GB

About the unit

Explanation of the display

Preparation for Use

Installing/Replacing Batteries

1. Insert the batteries into the battery compartment mat-

ching correct polarities “+” and “-”.

2. Replace all batteries if the low battery indicator ap-

pears        .

3. Remove the batteries if the unit will not be used for a 

long period of time.

4. REMOVE all of the BATTERIES when utilizing an AC 

adapter.

Note: 

It is recommended that the same type of alkaline batteries 

be used to avoid incompatibility.

Systolic
rate

Diastolic
rate

Puls rate

Low 
battery
Error 
icon

Icon for 
users 
1, 2, 3

Pulse symbol

WHO pressure 
bar indicator

Number of 
memory space

Irregular 
heartbeat 
detector

Hour:Minute

Day/Month

 


background image

22

GB

Please dispose of defective appliances and used batte-
ries in compliance with statutory regulations
(disposal in general household waste is prohibited!).

Attaching the Pressure Cuff

1.  Wrap the cuff around the left arm. The arm should be 

bare.

2. Fasten the cuff. Don’t pull it too strongly or make the 

cuff too tight. The edge of the cuff should be approxi-

mately 1 inch from the crease of your elbow.

3. Attach the cuff on the right arm as shown in the 

fi

 gure 

if it is not possible to measure on the left arm.

Preparation for Use

 


background image

23

GB

Preparation for Use

Posture during Measurement

1. Sit upright and ensure that the measuring site is at 

heart level. Relax and retain a natural posture during 
measurement.

2. Measure and record blood pressure at the same time 

every day to establish your blood pressure pattern.

AC Adapter 

It is possible to use a stabilized AC adapter (output 6 V 
DC/800 mA) to operate the device.

Note:

1.  No power is taken from the batteries while the AC ad-

apter is connected to the device.

2. If AC adapter power is interrupted during measure-

ment, the device must be reset by disconnecting the 

AC adapter from the device.

3.  Please consult an appropriate dealer if you have ques-

tions relating to the adapter.

Power Source

4 alkaline “AA” type batteries (1.5 V)
or stabilized AC/DC adapter

6 V DC 800 mA

 


background image

24

GB

Operations

Setting the time and date

1. Press “SET” button to select memory store 1, 2,

or 3. 

2. Press “MODE” button (“month” starts 

fl

 ashing). Press 

“SET” button to set the correct month. 

3.  Press “MODE” button again (“date” starts 

fl

 ashing). 

  Press “SET” button to set the correct date.

4.  Press “MODE” button again (“hour” starts 

fl

 ashing).

  Press “SET” button to set the correct hour in 12-hour 

format. 

5. Press “MODE” button again (“minute” starts 

fl

 ashing).

  Press “SET” button to set the correct minute.

6. Press “MODE” button again to con

fi

 rm the time and 

date. 

Measuring Blood Pressure

1.  Wrap the cuff around the arm (refer to „Attaching the 

Pressure Cuff“).

2.  Sit upright on a chair (refer to „Posture during Measure-

ment“). 

3.  Press “SET” button to select a particular memory store 

number. 

4.  Then press “START/STOP” to start automatic measure-

ment. 

When taking repeat measurements, be sure to select the 
same memory store number before pressing „START/
STOP“.

5. The cuff is in

fl

 ated. When the pulse is detected, the 

PULSE symbol will start 

fl

 ashing.

6. After the measuring procedure has been completed, 

the blood pressure values (systolic pressure and di-

astolic pressure) along with the pulse rate and WHO 
classi

fi

 cation indicator will be shown on the display for 

1 minute. After approx. 1 minute without being used, 

the unit will automatically switch off. 

 


background image

25

GB

Operations

Arrhythmia-Detection:  

If the symbol        appears, it means the unit has detected 
an irregular pulse during measurement. If the symbol 
appears regularly please consult a quali

fi

 ed physician for 

professional advice.

Storing data

After each blood pressure measurement, the blood pres-
sure values, pulse rate, time and date will be automati-
cally stored. Each of the three memory stores saves the 

latest 30 measurements. If more than 30 measurements 

are saved, the memory will automatically delete the ear-

liest values. 

Recalling data: 

1. Press the “MEMORY” button. A particular memory 

store will appear on the display.

2. Press “SET” to 

fi

 nd the correct memory store.

3.  Press “MEMORY”. The average value of the last three 

measurements is shown by the following symbol:     . 
If no values have been stored, nothing will appear on 
the display. The most recently measured value will be 

displayed 

fi

 rst.

4. By pressing the “MEMORY” button again you can 

view each of the saved values in the selected memory 
store.

5.  After viewing the saved measurements, press “MEMO-

RY” again to switch back to the initial display.  

6. You can also switch back to the initial display by pres-

sing the “START/STOP” button. 

 


background image

26

GB

 

 

Storing data, 
Care and Maintenance

Erasing data: 

1.  To erase the stored values, remove all 4 batteries from 

the device and then put them in again, taking care to 

ensure correct polarity. 

2. To check that the data has been erased, press the 

“MEMORY” button. No values should show up on the 

screen.

Care and Maintenance

Do not drop the unit. It is not 
shock-proof.

Do not modify or disassemb-
le the unit or the arm cuff.

Do not twist the arm cuff.

Use a cloth moistened with 
water or neutral detergent to 
clean the body of the unit 
and then wipe it dry.

 


background image

27

GB

Care and Maintenance

Avoid thinner, benzine, 
and other harsh
cleaners.

Keep the unit in a 
suitable place.
Avoid high temperature, 
direct sunlight, 
high moisture, and dust.

Remove the batteries if 
the unit will not be 
used for a long time.

Do not press the 
POWER button if the cuff 
has not been 
properly wrapped around 
the arm.

 


background image

28

GB

Speci

fi

 cations

Display System

Liquid Crystal Display

Measuring 
Method

Oscillometric

Power Source

4 alkaline “AA” type batteries
(1.5V) or AC/DC adapter

Measuring 
Range

0 - 300 mmHg 

 

40 - 199 pulse beats per minute

Accuracy

±3mmHg
±5% pulse rate

In

fl

 ation

Micro centrifugal pump

De

fl

 ation

Electromagnetic valve 

Memory

3 memory stores with 30 storage 
spaces each = total 90 stored 
values

Display

LCD (year/date/time, pressure and 
pulse rate)

Low Battery 
Indicator

yes

Automatic 
switch-off

after approx. 1 minute

Battery Life

around 300 operations

Operating Envi-
ronment

+10°C – +40°C; RH

85%

(+50°F – +104°F)

Storage Envi-
ronment

-20°C – +70°C; RH

85%

(-4°F – +158°F)

Dimensions

150 x 100 x 65 mm 

Weight approx. 

265g 

(including batteries)

Speci

fi

 cations are subject to change without notice for 

purposes of product improvement.
 
It is recommended that the unit be calibrated by an aut-
horised laboratory every two years.

 


background image

29

GB

 

 

Error Message,
Quality Standard

Replace batteries: 

Replace all 4 batteries 

with new ones. Insert the batteries in correct 
polarities.

EE

Appears when measurement error oc-
curs or blood pressure value is displayed 
excessively low or high: 

Measure again. 

Wrap the cuff correctly and keep the arm still 
during measurement.

E1

Cuff tube may not be plugged into mo-
nitor correctly: 

Check cuff connection. 

Measure again.

E2

Pressure exceeds 300 mmHg: 

Turn the unit 

off to clear, then measure again.

E3

Measurement data that result in an 
error message: 

Measure again.

Quality Standard

Geratherm

®

 is certi

fi

 ed in accordance with Council Direc-

tive 93/42/EEC, Annex II and DIN EN ISO 13485 and 
is entitled to af

fi

 x the CE-mark CE 0118 (Noti

fi

 ed  Body: 

LMET).

The blood pressure monitor conforms to EN 1060-1 
(Non invasive sphygmomanometers part 1: General 
requirements) and EN 1060-3 (Non invasive sphyg-
momanometers part 3: Supplementary requirements 
for electromechanical blood pressure measuring 
systems).

Manufacturer:

Geratherm Medical AG
Fahrenheitstr. 1
98716 Geschwenda
Germany