PDF User Manual

  1. Home
  2. Manuals
  3. GERATHERM GT-101 Instruction Manual

GERATHERM GT-101 Instruction Manual

Made by: GERATHERM
Type: Instruction Manual
Category: Thermometer
Pages: 15
Size: 0.27 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

NL

P

E

I

F

GB

D

AR

17

INSTRUCTION MANUAL

Contactless Infrared 

Thermometer

GT-101


background image

D

GB

F

I

E

P

NL

AR

18

A

Dear customer,

Thank you for your con

fi

 dence in Geratherm

®

 

and congratulations on your purchase!
By purchasing the Geratherm

®

 non contact ther-

mometer you have acquired a quality product by 
Geratherm

®

.

This thermometer has been clinically tested and 
proven to be safe and accurate when used in ac-
cordance with its operating instruction manual.
Please read through these instructions carefully 
so that you understand all functions and safety 
information.

Best regards,
The Geratherm

®

 Team


background image

R

NL

P

E

I

F

GB

D

AR

19

CONTENTS

Descriptions of Parts  

19

Advantages of the Thermometer 

20 

Safety Precautions 

21 

Important Information about 
Temperature Measurement 

21

Technical Data  

22

Battery Replacement  

23

Alternating between Body and 
Object Mode  

23

Measuring Body Temperature  

24

Measuring the Temperature of 
an Object  

26

Alternating between Celsius 
and Fahrenheit  

27

Recalling Stored Data  

27

Error Messages  

28

Cleaning and Disinfection  

29

Disposal  

29

Warranty  

30

Certi

fi

 cate of guarantee 

31

DESCRIPTION OF PARTS

Tracking light

ON/OFF button

Battery 
compartment 
cover

Display

Measuring 
probe

START button

MODE button  

(for changing between body 
and object temperature 
measurement)


background image

D

GB

F

I

E

P

NL

AR

20

A

Fast and contactless temperature 
measurement

The innovative infrared technology ensures safe 
and hygienic temperature measurement within 
seconds.

Multifunctions

The extended measuring range (0 °C - 100 °C; 
32 °F - 212 °F) permits the measurement of 
body temperature and of the temperature of ob-
jects or surfaces, e.g. baby bottles, bath water, 
ambient temperature.

Safe and hygienic

The avoidance of direct skin contact means re-
duced transmission of viruses and other germs.

Accurate and reliable

The unique measuring probe, which incorpo-
rates an advanced infrared sensor, ensures 
that, when applied correctly, each measurement 
is accurate and reliable.

Fever alarm indicator

10 short beeps and a red LCD backlight indi-
cated that the patient’s temperature is above 
37.5 °C (99.4 °F).

Memory

The last 30 readings can be recalled from the 
memory, enabling ef

fi

 cient tracking of tempera-

ture variations.

ADVANTAGES OF THE 
THERMOMETER


background image

R

NL

P

E

I

F

GB

D

AR

21

•  This instrument may only be used for the pur-

poses described in this booklet. 

•  The thermometer is intended for private do-

mestic use only. 

•  The unit is not waterproof. Never immerse 

this instrument in any liquids. 

•  For cleaning and disinfection, please follow 

the instructions in the section entitled “Clean-
ing and Disinfection”.

•  Do not use the instrument if you think it is 

damaged or if you notice anything unusual.

•  Never open the instrument.

•  Ensure that children do not use the instru-

ment unsupervised.

•  Protect it from:

 extreme temperatures
 impact and dropping
 contamination and dust
 direct sunlight
 heat and cold

•  If the instrument is not going to be used for 

a prolonged period, the batteries should be 
removed.

•  Use of this instrument is not intended as a 

substitute for consultation with your physi-
cian.

SAFETY PRECAUTIONS

IMPORTANT INFORMATION 
ABOUT TEMPERATURE 
MEASUREMENT

This thermometer measures infrared energy 
radiated from the forehead as well as from ob-
jects. This energy is collected through lenses 
and converted into a temperature value.
Temperature readings obtained by scanning 
above the eyebrow area will provide the great-
est accuracy.


background image

D

GB

F

I

E

P

NL

AR

22

A

measuring 
range:
body mode:
object mode:

34.0 - 42.2 °C (93.2 - 108.0 °F)
0 - 100 °C (32 - 212 °F)

Resolution:

0.1 °C oder 0.1 °F

Accuracy 
(laboratory):

36.0 °C - 39.0 °C: +/- 0.2 °C 
(96.8 °F - 102.2 °F: +/- 0.4 °F); 
other ranges +/- 2 %

Measuring 
time:

approx. 1 second

Display:

Liquid crystal display, 4 digits

Battery:

2 x 1.5 V, size AAA

Lifetime of 
battery:

approx. 1000 measurements

Fever alarm:

10 short beeps and red LCD 
backlight if the reading is equal 
to or greater than 37.5 °C 
(99.4 °F)

Memory:

Storage of up to 30 measured 
values

Dimensions:

165 mm x 40 mm x 20 mm

Weight:

approx. 81 g, including battery

Operating 
conditions:

Body mode: 16 - 40 °C 
(60.8 - 104 °F),
Object mode: 
5 - 40 °C (41 - 104°F),
Humidity: 15 - 95 % RH

Storage 
conditions:

-20 to +50 °C (-4 to +122 °F), 
Humidity: 15 - 95 % RF

Automatic 
switch-off:

approx. 3 min after last 
measurement

Quality guarantee:

The unit conforms to the Council Directive 93/42/
EEC concerningmedical devices, ASTM E1965 
“Standard Speci

fi

 cation for Infrared Thermo-

meters for Intermittent Determination of Patient 
Temperature“ and draft standard IEC 80601-2-56 
“Medical electrical equipment - Part 2-56: Par-
ticular requirements for basic safety and essential 
performance of clinical thermometers for body 
temperature measurement“. Geratherm

®

 is certi-

fi

 ed in accordance with Council Directive 93/42/

EEC, Annex II and DIN EN ISO 13485 and is enti-
tled to af

fi

 x the CE 0118 (Noti

fi

 ed Body: LMET) 

TECHNICAL DATA


background image

R

NL

P

E

I

F

GB

D

AR

23

This instrument is supplied with 2 new, longlife 
1.5 V size AAA batteries. The batteries need re-
placing when this icon “     ” is the only symbol 
shown on the display.

Slide the battery cover open and insert 2 new 
batteries, then close the battery cover again. 
When replacing the batteries, ensure correct 
polarity by referring to the symbols in the battery 
compartment.

Attention:

Keep the thermometer and batteries out of the 
reach of young children. Do not dispose of the 
batteries in a 

fi

 re. They may explode.

To switch from body to object mode (and vice 
versa), push the mode button.

BATTERY REPLACEMENT

ALTERNATING BETWEEN 
BODY AND OBJECT MODE


background image

D

GB

F

I

E

P

NL

AR

24

A

NOTES:

•  The thermometer and the patient must re-

main in a room with a stable room tempera-
ture for at least 30 minutes before measuring 
the temperature.

•  Do not take a baby’s temperature during or 

directly after breastfeeding.

•  Do not use the thermometer in a humid envi-

ronment.

•  Use of the unit under operating conditions 

outside the range indicated may result in 
false readings.

•  Patients should not drink, eat, or exercise be-

fore/while taking the measurement.

•  Do not move the measuring device away 

from the area to be measured until the termi-
nation beep has sounded.

•  10 short beeps and a red LCD backlight indi-

cate that the patient’s temperature is above 
37.5 °C (99.4°F).

•  Always take the temperature at the same 

measuring site, otherwise the temperature 
readings may vary.

•  A control measurement using a conventional 

thermometer is recommended in the follow-
ing cases:

1. In the case of new-born infants up to 

100 days old.

2. In the case of children under three 

years of age with a compromised im-
mune system, for whom the presence 
or absence of fever is critical.

3. While the user is learning how to use 

the thermometer, until such time as 
he/she has become thoroughly familiar 
with the instrument and obtains consist-
ent readings.

4. If the measurement is suspiciously low.

MEASURING BODY 
TEMPERATURE


background image

R

NL

P

E

I

F

GB

D

AR

25

USE:

1. Press the ON/OFF button   . The display 

is activated to show all segments for 2
seconds.

2.  The last measurement reading will automati-

cally be shown on the display for 2 seconds 
with the “

M

” icon.

3. The thermometer is ready for measurement 

as soon as the “

°C

” or “

°F

” icon starts flashing 

and a beep sound is heard.

4.  Press the mode button until you see a symbol 

in the form of a head on the display. Now you 
are in the body temperature measurement 
mode.

5.  Aim the thermometer at the centre of the fore-

head, holding it no more than 5 cm away from 
the skin surface. If the forehead is covered 
with hair, perspiration or dirt, please remove 
this beforehand in order to ensure accurate 
measurement.

6. Press the START button and steadily move 

the thermometer from the middle of the fore-
head to the temple area (about 1 cm above 
the eyebrow). The activated blue tracking 
light will indicate the measurement area.

7. After 3 seconds a long beep will verify the 

completion of measurement. If the temple 
area has not been reached by the time the 
long beep is heard, repeat the measurement 
as described above, but move the thermom-
eter a little faster.

8.  Read the recorded temperature from the LCD 

display.

-  If the reading is below 37.5 °C (99.4 °F), you 

will hear a long beep and the backlight of the 
display will be green.

-  If the reading is at or above 37.5 °C (99.4 °F), 

you will hear 10 short beeps, and the back-
light of the display will be red.

MEASURING BODY 
TEMPERATURE


background image

D

GB

F

I

E

P

NL

AR

26

A

NOTE:

• Readings from different measuring sites 

should not be compared, as normal body 
temperature varies depending on the meas-
uring site and the time of day.

Normal body temperature ranges:

•  In the rectum (rectal): 36.6 °C - 38.0 °C
  (97.9 °F - 100.4 °F)

•  In the mouth (oral): 35.5 °C - 37.5 °C 
  (95.9 °F - 99.5 °F)

•  In the armpit (axillary): 34.7°C - 37.3°C
  (94.5 °F - 99.1 °F)

• Geratherm

®

  non contact: 35.4 °C - 37.4 °C

  (95.7 - 99.3 °F)

1.  Follow steps 1-3 in the chapter on Measuring 

Body Temperature. 

2.  Press the mode button until you see a symbol 

in the form of a house on the display. Now 
you are in the object temperature measure-
ment mode.

3.  Aim the thermometer at the centre of the ob-

ject whose temperature you wish to measure, 
holding it no more than 5 cm away from the 
surface. Press the START button. After 3 sec-
onds a long beep will verify the completion of 
measurement.

4.  Read the recorded temperature from the LCD 

display.

MEASURING BODY 
TEMPERATURE

MEASURING THE TEMPERA-
TURE OF AN OBJECT  


background image

R

NL

P

E

I

F

GB

D

AR

27

To switch the display between °C and °F, sim-
ply turn OFF the unit, then press and hold the 
START button for 5 seconds; after 5 seconds, 
the current measurement scale (“°C” or “°F” 
icon) will be 

fl

 ashing on the display. 

Now switch the measurement scale between °C 
and °F by pressing the START button. After you 
have selected the desired measurement scale, 
wait for 5 seconds and the unit will automatically 
enter the “ready for measuring” mode.

This thermometer can recall the last 30 read-
ings.

1. Press START when the power is off. The 

memory icon “M” will flash.

2.  Press START again to recall the last reading. 

3.  Press START repeatedly to recall the last 30 

readings in succession.

ALTERNATING BETWEEN 
°C AND °F

RECALLING STORED DATA


background image

D

GB

F

I

E

P

NL

AR

28

A

Display Description

The measured temperature is 
too high 

H

 appears if the reading is 

above 42.2 °C (108 °F) in body 
mode or 100 °C (212 °F) in 
object mode.

The measured temperature 
is too low 

L

 appears if the reading is 

below 34 °C (93.2 °F) in body 
mode or 0 °C (32 °F) in object 
mode.

Ambient temperature is 
too high

H

 appears in connection with 

      if the ambient temperature 
is above 40 °C (104 °F).

Ambient temperature is 
too low

L

 appears in connection with 

      if the ambient temperature 
is below 16 °C (60.8 °F) in 
body mode or 5 °C (41 °F) in 
object mode.

Error indication on the 
display

3 short signal tone will sound.

Blank display

Check the position or polarity of 
the battery.

Flat battery indication

Insert new batteries.

ERROR MESSAGES


background image

R

NL

P

E

I

F

GB

D

AR

29

 •  Use a swab or cotton tissue moistened with 

alcohol (e.g. 70% Isopropyl) to clean the ther-
mometer casing and the measuring probe. 
Ensure that no liquid enters the interior of 
the thermometer. Never use abrasive clean-
ing agents, thinners or benzene for cleaning 
and never immerse the instrument in water or 
other cleaning liquids.

•  Take care not to scratch the surface of the 

measuring probe and the display.

•  Do not reuse the thermometer until it is com-

pletely dry.

•  Soiling on the display of the measuring sen-

sor can affect the measurement reading. 
Make sure that the display is free of contami-
nants, and if required, clean as described 
above. 

Observe the applicable regulations when dis-
posing of the device and batteries.
This product must not be disposed of together 
with domestic waste.
All users are obliged to hand in all electrical or 
electronic devices, regardless of whether or not 
they contain toxic substances, at a municipal or 
commercial collection point so that they can be 
disposed of in an environmentally acceptable 
manner.
Please remove the batteries before disposing of 
the device/unit. Do not dispose of old batteries 
with your household waste, but at a bat-
tery collection station at a recycling site 
or in a shop.

CLEANING AND 
DISINFECTION

DISPOSAL


background image

D

GB

F

I

E

P

NL

AR

30

A

This thermometer is guaranteed for 2 years from 
the date of purchase against any manufactur-
ing defect, conditional upon normal household 
use. If your unit does not work owing to defec-
tive parts or assembly, we undertake to repair it 
without charge. Apart from the battery, all parts 
of the unit are subject to this warranty. Damage 
to the unit caused by improper use is not cov-
ered by this warranty. 
We recommend that the accuracy of the unit 
be checked annually by an authorised labora-
tory (mandatory in Germany). This checking 
procedure is not a service provided under the 
warranty. 

 

Manufacturer: 

Geratherm Medical AG
Fahrenheitstraße 1
D-98716 Geschwenda
Germany

WARRANTY


background image

R

NL

P

E

I

F

GB

D

AR

31

Geratherm

®

 guarantees the non contact ther-

mometer against any manufacturing defect 
for two years from the date of purchase if it is 
returned to the dealer from whom it was pur-
chased. During this period the unit will be re-
paired or replaced free of charge if the fault is 
due to defective design or assembly.
This guarantee does not cover any damage or 
defect caused by improper handling resulting 
from use that is not in compliance with these in-
structions, or caused by unauthorised attempts 
to repair it. Your local dealer cannot declare this 
manufacturer’s guarantee invalid, but may ex-
pand it by additional guarantees at his discretion 
and at his own expense.

Model No.:

 ........................................................

Serial No.:

  ........................................................

Date of purchase:

 ............................................

Dealer’s signature:

 ..........................................

Invoice No. / Receipt No.:

 ...............................

Name and 
address of dealer: 

...........................................

           ..........................................

Manufacturer:

Geratherm Medical AG
Fahrenheitstraße 1
D-98716 Geschwenda
Germany

CONTACTLESS INFRARED 
THERMOMETER
Geratherm

®

non Contact 
GEF-101

CERTIFICATE OF 
GUARANTEE