background image

tensio control

Manufactured by:

Geratherm Medical AG

Fahrenheitstraße 1

98716 Geschwenda

Germany

Phone: +49 (0) 36205 98-0

Fax: +49 (0) 36205 98-116

E-Mail: info@geratherm.com

www.geratherm.com

INSTRUCTION MANUAL

Model GP-6220

Fully Fuzzy Auto Digital Wrist

 Blood Pressure Monitor

GB

 


background image

CAUTION

1. Consult your physician to verify your blood pressure range before using 

  this device at home.

2. If the cuff causes any discomfort during measurement, press the power 

  key to turn off the device immediately.

3. Pull off the velcro strap to detach the cuff if the pressure is over 300 mm 

  Hg and the cuff does not deflate automatically.

Blood pressure measurements obtained with this unit are equivalent to 

those obtained by a trained person using the cuff/stethoscope ausculta-

tion method. This blood pressure monitor complies with the regulations 

set out in EU Council Guideline 93/42/EEC of 14th June 1993 concerning 

Medical Products and with the DIN EN 1060-1 standard (Non-invasive 

blood pressure monitors/part 1, general requirements) and DIN EN 1060-3 

(Non-invasive blood pressure monitors/part 3, supplementary requirements 

for electro-mechanical blood pressure monitors). A quality management 

system in compliance with EN ISO 13485 ensures that the required quality 

criteria are met.

WARRANTY:

Three years from the date of purchase.

GB

1 - GB

 


background image

INFORMATION YOU SHOULD KNOW BEFORE 

OPERATING THE DEVICE

What is blood pressure?

A force is created by the heart as the ventricle forcibly ejects blood into the 

blood vessels and through the vascular system. Another force is created 

by the arteries as they resist the blood flow. Blood pressure is the result of 

these two forces. 

What are systolic and diastolic pressures?

Systolic pressure represents the highest pressure at the height of the 

heart‘s contraction. Diastolic pressure is the lowest pressure when the 

heart is resting.

Is my blood pressure normal?

See the following blood pressure classification chart released by the WHO 

(World  Health Organization) for evaluation of your blood pressure level.

What about low blood pressure?

Generally speaking, a lower blood pressure reading is better unless it 

causes some uncomfortable symptoms such as fainting and/or lightheaded-

ness. Fluctuation and variation in blood pressure 

GB

2 - GB

 


background image

Fluctuation and variation in blood pressure

The following chart shows possible blood pressure fluctuations during a

24-hour period.

The following factors will 

influence blood pressure 

measurement results 

and cause variations:

Bathing, Breathing, 

Conversation, Meals, 

Smoking, Exercise, 

Drinking Alcohol, Mo-

ving, Thoughts, Mental 

tension, Temperature 

change, etc.

Hypertension

Boundary

Normal

Lower

GB

3 - GB

 


background image

ABOUT THE DEVICE 

The cuff is designed to fit wrist sizes between 13.6 and 19.5 cm

 (5.35 to 7.68 inch). 

Memory Botton

LCD display

Power Button

Battery Cover

GB

4 - GB

 


background image

ACHTUNG

EXPLANATION OF DISPLAYS

Date

Memory

Low 

Battery

Indicator

Pulse 

Indicator

IPD (Irregular 

Pulse Detection)  

Systolic

Diastolic

Pulse Rate

ACHTUNG

PREPARATION FOR USE

Installing/Replacing Batteries

1.  Press lightly on the arrow and slide the battery cover in

 

the direction of the arrow.

2.  Insert the batteries into the battery compartment

 

matching correct polarities “+“ and “-“.

Note:

•  Replace both batteries if the low battery indicator 

 

appears.

•  Remove the batteries if the device will

 

not be used for a long period of time.

•  It is recommended that the same 

 

type of alkaline batteries be 

 

used to avoid incompatibility.

GB

5 - GB

 


background image

Attaching the Pressure Cuff

1.   Free the left wrist of any clothing etc. and 

 

wrap the cuff directly around it. The display 

 

should be positioned on the palm side of the wrist.

2.   Fasten the cuff. Make sure it is not too tight. 

 

The cuff‘s upper edge should be approxima-

 

tely 1 cm (0.39 inch) from the palm line.

3.  If it is not possible to measure on the left 

 

wrist, attach the cuff on the right wrist as 

 

shown in the figure.

Measuring Posture

1.  Sit upright and place your forearm onthe 

 

storage case so that the device is at heart 

 

level. Relax and measure in a natural

 

position.

2.   Measure and record blood pressure at the 

      same time every day to establish your

 

blood pressure pattern.

GB

6 - GB

 


background image

ACHTUNG

HOW TO OPERATE THE DEVICE

1.  Setting the Clock

 

Enter the clock setting mode by pressing and holding the MEMORY 

 

button for over three seconds. The display will show a flashing year. 

 

Press the POWER button to adjust the year when it is flashing. Then 

 

click the MEMORY button again, a „month „ will appear and flash to be 

 

adjusted, and then „date“, „hour“, and „minute“ will follow as you press 

 

and release the MEMORY button.

 

 

To Adjust the Clock

 Press the POWER button to adjust the „month“, 

 

„date“, „hour“ and „minute“ when they are flashing.

2.  Measuring 

 

Blood Pressure

 

Press and release the 

       POWER button to start 

       measuring automatically. 

 

When the measure-

 

ment is finished, the

 

display will show the measured blood pressure and pulse rate.

 

Press the POWER button to turn off the device. Otherwise the device 

 

will automatically turn off 

after 150 seconds.

 

Note:  If the symbol         appears, it means the unit has detected 

 

irregular pulse during measurement. If the symbol appears regularly 

 

please consult a qualified physician for professional advice.

Initial

display

Pumping Measuring and

buzzer sounds

GB

7 - GB

 


background image

3.    Recalling Stored Values

3.1

  Press and release the

 

MEMORY key to recall the

 

last reading. (Example: 

 

no. 35 in the memory). The

 

display will show the stored

 

pressure and pulse rate in

 

alternation.

3.2  Press the MEMORY

 

button to go to previous stored values.

4.   Erasing Stored Values

 

You may erase one or all records in the

 

memory. 

To delete one record:

 

Step 1:

 

Press and release MEMORY button 

 

to display stored values. Press and release 

 

MEMORY button again to choose the

 

record that you wish to delete.

 

Step 2: 

Press and hold the POWER button until the display shows „dEL“. 

 

Step 3: 

Press and hold the POWER button. After three beeps are heard, 

 

the selected record is deleted. 

 

To delete all stored values:

 

 

Follow 

steps 1

 and 

above.

 

Step 3: 

Press the MEMORY button again and the display shows „dEL ALL“. 

 

Step 4:

 Press and hold the POWER button. After three beeps are 

 

heard, all records are deleted.

GB

8 - GB

 


background image

ACHTUNG

BETRIEB DES GERÄTES

ACHTUNG

CARE AND MAINTENANCE

Do not drop 

the device.

Do not twist 

the wrist cuff.

Do not modify or disas-

semble the body or the 

wrist cuff.

Use a cloth moistened 

with water or neutral 

detergent to clean the 

body of the device and 

thenwipe it dry.

Avoid thinner, 

benzene, and 

other harsh 

cleaners.

Keep the device in a sui-

table place. Avoid high 

temperatures direct sun-

light, high humidity, 

and dust.

Remove the batte-

ries if the device 

will not be used

for a long time.

Do not press the PO-

WER button if the cuff 

has not been properly 

wrapped around the 

wrist.

GB

9 - GB

 


background image

ACHTUNG

BETRIEB DES GERÄTES

ACHTUNG

ERROR MESSAGES

Message

Correction

or No display

The pressure measured was lower than 

20 mm Hg. 

Please measure again.

The pressure measured was higher than

300 mm Hg. 

Please measure again.

Pumping error.

Please check cuff and try again.

The pressure can not be measured due to 

signal noise. 

Please measure again.

The pumping pressure is higher 

than 300 mm Hg.

Please measure again.

Low battery. 

Please check and, if 

necessary, replace the 2 batteries.

GB

10 - GB

 


background image

ACHTUNG

SPECIFICATIONS

Display System

Liquid Crystal Display

Measuring Method

Oscillometric

Power Source

2 alkaline “AAA“ type batteries (1.5 V)

Measuring Range  

20 - 300 mm Hg; 40-200 beats/minute

Accuracy

± 3 mm Hg ± 5% pulse rate

Inflation Pressure 

Automatic with integrated 

electrical  pump

Exhaust

Solenoid valve

Memory

85 sets

Display

LCD (year/date/time, pressure and pulse)

Low Battery Indicator

Yes

Auto Power-Off

After 150 s  w/o any operation

Battery Life

Around 250 operations

Operating Environment

+10 - +40°C; RH < 85%

Storage Environment

-20 - +50°C; RH < 85%

Dimensions

76 x 76 x 38 mm (W x D x H)

Weight

Around 133g (includingbatteries)

GB

11 - GB

 


background image

Specifications are subject to change for improvement without notice. Calibra-

tion is recommended every two years.

GB

12 - GB