INSECT LIGHT TRAP SYSTEM

 

 
 

 

 

 

Instruction Manual 

 

 

Covers Models: 

Genus

® 

Spectra & Genus

® 

Spectra Compact 

 

 

 

 


background image

                                                                  2/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 

 

 


background image

                                                                  3/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 

Item No. 

Description 

Front Screen 

Lamp Holder  

Control Board 

Lamp 

Lamp Clip 

Table Stand 

SPECTRA 

SPECTRA 
COMPACT 

 


background image

                                                                  4/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 

Grounding Instructions 

 
THE UNIT IS EQUIPPED WITH AN APPROPRIATE 3-CONDUCTOR 
CABLE AND 3-PRONG GROUNDING TYPE PLUG TO FIT THE 
PROPER GROUNDING TYPE RECEPTACLE.   
TO REDUCE THE RISK OF AN ELECTRIC SHOCK, THE PLUG 
MUST BE PLUGGED INTO AN APPROPRIATE OUTLET THAT IS 
PROPERLY INSTALLED AND GROUNDED [SEE DIAGRAM 
BELOW]: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
CONSULT A SUITABLY QUALIFIED ELECTRICIAN IF THE 
GROUNDING INSTRUCTIONS ARE NOT COMPLETELY 
UNDERSTOOD OR IF IN DOUBT AS TO WHETHER PROPER 
GROUNDING EXISTS. 

 

EXTENSION CABLES ARE NOT TO BE USED WITH THIS UNIT. 
 
 

SAVE THESE INSTRUCTIONS

 

 
 
 

SPECTRA 

 


background image

                                                                  5/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

Safety Instructions

 

CAUTION: 

THE UNIT IS INTENDED FOR COMMERCIAL INDOOR USE ONLY AND 
NOT TO BE USED WHERE IT MAY BE EXPOSED TO WATER, INCLUDING 
ROOFED, BUT OPEN PORCHES OR IN WET LOCATIONS [E.G. ABOVE 
COOKERS OR IN STEAM ROOMS].  
THE UNIT IS NOT CONSTRUCTED FOR USE OUTDOORS AND TO AVOID 
THE RISK OF FIRE OR ELECTRIC SHOCK IS THEREFORE NOT 
SUITABLE FOR USE IN BARNS, STABLES AND SIMILAR LOCATIONS. 
 
WARNING: SHOCK HAZARD. DO NOT OPEN WHILST CONNECTED TO 
THE ELECTRICAL SUPPLY. NO USER SERVICEABLE PARTS INSIDE.  
REPLACING THE CONTROL BOARD AND LAMPS MAY BE PERFORMED 
BY THE USER. ALL OTHER REPAIRS AND MAINTENANCE MUST BE 
PERFORMED BY QUALIFIED PERSONNEL ONLY.  
TO MAXIMISE EFFICIENCY AND SAFETY, REPLACE CONTROL BOARD 
CONTAINING INSECTS AS NEEDED. 
STORE THE UNIT INDOORS WHEN NOT IN USE

  

THE UNIT MUST BE KEPT OUT OF REACH OF CHILDREN 
THIS  UNIT  IS  NOT  INTENDED  FOR  USE  BY  PERSONS  (INCLUDING 
CHILDREN)  WITH  REDUCED  PHYSICAL,  SENSORY  OR  MENTAL 
CAPABILITIES,  OR  LACK  OF  EXPERIENCE  AND  KNOWLEDGE,  UNLESS 
THEY 

HAVE 

BEEN 

GIVEN 

SUPERVISION 

OR 

INSTRUCTION 

CONCERNING  USE  OF  THE  UNIT  BY  A  PERSON  RESPONSIBLE  FOR 
THEIR SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT 
THEY DO NOT PLAY WITH THE UNIT. 
TO MAXIMISE SAFETY DISCONNECT THE UNIT FROM THE 
ELECTRICITY SUPPLY WHEN NOT IN USE, BEFORE SERVICING, WHEN 
CHANGING LAMPS AND CLEANING. REFER TO SERVICING 
INSTRUCTIONS FOR METHOD AND FREQUENCY OF SERVICE. 
DO NOT ABUSE THE POWER CABLE - NEVER CARRY THE UNIT BY THE 
CABLE OR PULL IT FROM THE RECEPTACLE. KEEP THE CABLE FROM 
HEAT, OIL, AND SHARP EDGES. 
 IF CABLE IS DAMAGED DO NOT USE. HAVE THE CABLE REPLACED BY 
A QUALIFIED ELECTRICIAN. 
DO NOT INSERT FOREIGN OBJECTS INTO THIS UNIT. 
THE UNIT IS NOT TO BE USED IN LOCATIONS WHERE FLAMMABLE 
VAPOUR OR EXPLOSIVE DUST IS LIKELY TO EXIST. 
TO PROVIDE CONTINUED PROTECTION AGAINST THE RISK OF 
ELECTRIC SHOCK, CONNECT TO PROPERLY GROUNDED OUTLETS 
ONLY. 
 

 

 

 


background image

                                                                  6/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 

INTRODUCTION

 

Please read these instructions, follow them carefully and keep them for future 
reference. The unit, when properly installed and maintained, will operate 
safely and reliably for many years. 

 

TYPE OF UNIT 

The 

Genus

®

 Spectra

 range consists of 2 models; a 2 lamp unit, a 1 lamp unit. 

Both models use the same Control boards. Lamp types are PL36W UV-A .  

 
 

UNPACKING  

Each unit is carefully packed before leaving the production factory to ensure 
arrival in perfect working order. Please be sure to remove all packing from 
around and within the unit before installation. 

 

LOCATIONS 
1. 

The extent to which insects are attracted to 

Genus

®

 Spectra

 depends 

largely on the intensity of other light available, whether daylight, or artificial 
light, keep the unit switched on 24 hours. 

2. 

Mount the unit within 1-1.5m (3-

5’) of the floor whenever possible. 

Note. If mounting vertically, ensure lamp holders are at the top of the unit. 

3. 

To comply with current Health and Safety legislation, ensure that safe and 
appropriate access to the unit for maintenance and cleaning is available. 

4. 

Place the unit as far as possible from windows (to minimise competition 
from sunlight) and any other competing light sources. 

5. 

Do not place the unit directly over exposed foods, food preparation 
surfaces or packing lines. 

6. 

Do not hang the unit over sources of heat or steam since this may 
damage the insulation of the electric cables.  

7. 

Place the unit out of reach of children whenever possible. 

 
CONNECTION TO THE ELECTRICITY SUPPLY

 

The unit must be installed by a qualified electrician observing the following 
instructions. 

1. 

Check the input voltage on the unit label is correct for your electrical 
supply. 

2. 

Ensure that the circuit is fused at 3A maximum. 

3. 

Connect the unit to the electricity supply by the cable provided which is 
terminated in a plug connector. If this connector is incompatible with the 
installation it must be cut off, rendered unusable, and disposed of. 

4. 

Connection to the unit must be made using a cable type H05RN-F for 
European models or cable type 3x18AWG SJT for North American 
models. The cable supplied is of this type. 

5. 

Connect the cable to the electricity supply ensuring that the colour code is 
strictly followed [see table]: 

 


background image

                                                                  7/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 

 

Once connected, the cable should be mechanically secured to the wall using 
proprietary cable clips. 

 

CHANGING THE ELECTRICAL SUPPLY POWER CABLE 

If the power cable is damaged, it must be replaced by the manufacturer or its 
service agent or a similarly qualified person in order to avoid a hazard.  

 
INSTALLATION & FIXING  
       

The unit can be wall mounted horizontal, vertical and across corner. 

1. 

Temporarily fix the paper template to the selected position on the wall. 
Ensure the holes to be drilled are level. Mark holes through, then remove 
template. 

For concrete walls, drill 3/16” (4.8mm) dia mounting holes. 

Insert the four plastic anchors provided into holes and tap flush.  
Insert the self tapping screws provided to within 1/8

” (3.2mm) of the wall. 

For plasterboard walls use the aluminium anchors and machine screws 
provided. For wood panel walls, locate wall studs and use only the self 
tapping screws provided. 

2. 

Hang the unit on the keyhole slots in the wall plate. 

3. 

The unit can be table mounted using the Swivel stand located on the base 

NOTE: Ensure that unit

 

can be both switched off and electrically isolated by 

disconnection, for cleaning and maintenance. 
 

 
 

 

LIVE 

EARTH 

NEUTRAL 

BLACK OR 
BROWN 

GREEN OR 
GREEN/YELLOW 

WHITE OR BLUE 

Corner Vertical 
Wall Mount Holes 

Corner Horizontal 
Wall Mount Holes 

Plastic Anchors 

Aluminium Anchors 

Use Self Tapping Screws for Plastic Anchors. 
Machine Screws in Aluminium Anchors. 

FIXING DETAILS 

 

 


background image

                                                                  8/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 
LAMP REPLACEMENT  

Even though the amount of visible light emitted from the lamps does not 
appear to change, the output of UV light diminishes with time. To maintain 
efficiency, lamps must be replaced annually. Do not use UV-B or UV-C lamps. 
The replacement lamps are available from your local distributor. To replace 
the lamps, follow the procedure below:  

 

1. 

Isolate/disconnect the unit from the electrical supply before handling. 
Removing lamps from the unit prior to disconnection may cause the 
circuitry of the unit to switch to safety mode. See reset instructions. 
Open the front screen by lifting up and open to its full extent. 
Lamps may be warm; it is advisable to wait a few minutes until cool. 

2. 

Press the red button on the quick release lamp holder and pull the lamp 
out and away making sure to carefully disengage from the lamp clip at the 
opposite end. See diagram. 

3. 

To install new lamps, position the lamp base flush against lamp holder so 
the 4 pins are aligned with the slots and click securely into place. Push the 
lamp into the clip at the opposite end. 

4. 

Close the screen and reconnect the electrical supply.  

 

WARNING:  LAMPS  CONTAIN MERCURY.  DISPOSE  OF  ACCORDING  TO 
LOCAL, STATE OR FEDERAL LAW. SEE 

WWW.LAMPRECYCLE.ORG

 

 

 

 

 
 

Lamp Holder 

Lamp Clip 

Control Board Tabs 

Lamp 

Control Board 

 


background image

                                                                  9/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 
 
CONTROL BOARD REPLACEMENT:

 

The 

Genus

®

 Spectra

 fly trap uses the universal control board which is 

available from your local distributor.  

1.  Prepare  the  replacement  universal  control  boards  [see  following 

diagram].  

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

Genus

®

 Spectra

: Two halves of the complete universal control board are 

used.  Tear  off  and  discard  section  4.  Use  one  half  of  each  board  in  the 
upper and lower sections. 

Genus

®

  Spectra  Compact

:  Only  one  half  of  the  complete  universal 

control  board  is  used  in.  Tear  off  and  discard  section  4.  Use  one  half  of 
the board and keep the remaining half for future use. 
 

To replace the control board, follow the procedure below:  

1. 

Isolate unit from electrical supply before handling. 

2. 

Open the front screen by lifting up and open to its full extent. 

3. 

Remove the control board by gripping the tab at the base of the board, 
lifting up and off the plate. 

4. 

Take the replacement control board and refit ensuring it locates behind 
the tabs of the plate. Remove the release paper. 

5. 

Close the screen and reconnect the electrical supply. 

 

 
 

 


background image

                                                                  10/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 
 
 
IMPORTANT SERVICING INSTRUCTIONS 

For  proper  operation  the  interior  and  exterior  surfaces  of  this  unit  should  be 
cleaned once per month or as needed. Excessive grease and food particles 
will reduce its effectiveness as well as create an unsanitary condition.  

 

 

For the best results the control boards should be replaced monthly. If there 
is  high  insect  activity  control  boards  may  need  to  be  replaced  more 
frequently. 
The units are easier to clean if maintained often. 

1. 

Isolate unit from electrical supply before handling. 

2. 

Wipe the unit with a damp cloth. 

3. 

Change the control board every month or as needed. 

4. 

Change the lamps every 12 months. 

5. 

Reconnect electrical supply.  

 

NOTE:  ISOLATE/DISCONNECT  THE  UNIT  FROM  THE  ELECTRICAL 
SUPPLY BEFORE SERVICING.  
REMOVING  LAMPS  FROM  THE  UNIT  PRIOR  TO  DISCONNECTION  MAY 
CAUSE THE INTERNAL CIRCUITRY TO SWITCH TO SAFETY MODE. 

 
 
 

LAMP MAINTENANCE 

If either or both lamps glow dark purple (indicating a burned out lamp): 
Follow the procedure for replacing lamps.  

 
 

If both lamps are not glowing (no illumination at all): 
Follow the procedure for resetting the lamp circuit.  
 
The electronic circuit in the unit has a safety mode which temporarily shuts 
down the unit when an electrical surge occurs; this feature protects service 
personnel and the integrity of the unit. 
Units in shut down safety mode may appear to be defective or may give the 
false impression that the lamps are burned out. 
 
 
 
 

 


background image

                                                                  11/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

Common causes; 
 
1. Lamps are replaced without first disconnecting the unit from the electrical 
supply. 
2. Unit is exposed to extreme wet conditions. 
3. Electrical supply power surge occurred in the building. 
 
The unit must be reset to resume normal operation.

 

 
 
RESETTING THE LAMP CIRCUIT 
 

If lamps do not light after replacement, reset the circuit as follows: 
Isolate/disconnect the unit from the electrical supply.  
Wait for 15 seconds, a faint glimmer may occur in either or both lamps 
indicating the circuit has reset. 
Reconnect the unit to the electrical supply. 

 

 

 
ACTION IN CASE OF FAILURE 
 

In the unlikely event of failure, should the lamps fail to light please have the 
supply circuit and fuses checked by a qualified electrician. 
If the lamps and electrical supply are in order but the unit still does not 
function, please contact the local distributor. 
Your local distributor will be able to supply any parts and replacement UV 
lamps. 
 
 

SAFETY 
 

All 

Genus

®

 Spectra

 units are certified to European Safety Standards 

EN60335-1 and EN60335-2-59 recognised by BSI, KEMA, VDE, NEMKO, 
DEMKO and SEV, Australian Safety Standards; OCEI, and North American 
Standards; UL153, CSA C22.2-189 etc. 
These standards institutions are recognised throughout the world for setting 
the strictest controls over safety and efficiency. 
 
 
 

 
 
 

 


background image

                                                                  12/12: ACC673-044 Revision: 5.0 

 

 

Unit 29 Navigation Drive, Hurst Business Park, Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 Email: sales@b-one.com Web: www.b-one.com  

For Technical Support call the main number, fax or email: technical@b-one.com 

 
Manufactured in the UK by: 

 

 

 

29 Navigation Drive, Hurst Business Park, 

Brierley Hill, West Midlands, DY5 1UT, United Kingdom 

Tel: +44 (0)138 447 2900 Fax: +44 (0)138 447 2911 

www.b-one.com / www.biting-insects.com 

For technical support email technical@b-one.com