PDF User Manual

  1. Home
  2. Manuals
  3. GENI OBY-3 User Manual

GENI OBY-3 User Manual

Made by: GENI
Type: User Manual
Category: Flood Light
Pages: 18
Size: 3.07 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

TM

MOVING HEAD

OBY-3

User manual

CAUTION!

 


background image

 contents

Congratulations!

Thank you for purchasing OBY Series that elaborate manufactured 
by Geni abundant experience of stage-lights. Hereafter you can get 
high quality and low breakdown products on the market from 

Geni 

Electronics Co., Ltd.

; OBY Series concentrated unexpectedly 

lighting effects for animating stages.
If any question or suggestion you have, please offer the precious 
recommendation for improving our products and designs better; 
and create perspective and expectancy about future lighting.

Inspection

.

Description of the appearance

Features

Safety instructions

Lamp Installation

Rigging

Linking

Instruction for gobo replacement

DMX Channel Chart

Control Board

Maintenance

Replacing the Fuse

Appendix A  

Product Specifications

Connection with the mains

1

2

3

4

5

6

7

7

8

9

13

14

15

15

16

 


background image

1

Features

Ideal & powerful effects

Attractively smooth design

Simple and easy operation

Smooth and silent revolving of a big range of  570-degree in X axis and 

270-degree in Y axis, automatic electronic sensor to zero.

11 sharp dichroic colors + white.

6+1 easily replaceable rotating gobos.

Various kinds of glass gobos are available for clients' choices.

Rotating three facet prism.

1-7Hz fast flashing and 0-100% linear dimmer.

Remote-controlled focus.

Remote-controlled lamp switch ON/OFF.

Stylish, high impact resistant polymer shell, which is lighter than any 

one else of the same class in the market.

Solid square base is convenient set on the TRUSS, or directly stand on 

the ground or stage for uses.

Systematic modular construction design has all inner function wheels 

and PCBs modularized, which allows version update or customization

more convenient.

Sophisticated optical system makes light output more bright and sharp.

Standard USITT DMX512 protocol, 13 or 11 DMX Channel.

High-torque stepper motors, smooth and precise micro-stepping 

control.

LED screen controls DMX coding and built-in functions' election, as 

well as also display  lamp's time usage.

 


background image

Description of the appearance

2

 


background image

3

Inspection

Carefully unpack the carton, and make sure if any damage or loss 
caused by transportation.

Contact your Geni dealer to assure your right by telephone or 
facsimile immediately if damage has occurred or if something is 
missing.

Packing List:

A. OBY-3 Moving Head
B.Operating Manual
C.
D.GOBO
E. Lamps (

Optional

)

Bracket

 


background image

Safety instructions

This appliance must be earthed (grounded).

Disconnect power before removing covers or servicing.

Keep case closed while operating.

OBY-3 contains no user serviceable parts. Refer servicing to 
qualified technicians only.

Lamp and components become hot during operation. Allow time to 
cool before handling.

Keep flammable material at least one meter away from unit.

Do not operate in wet conditions or near liquids.

Keep air vents clear to avoid overheating.

Lamp produces hazardous UV light. Do not look directly at lamp 
when lit.

Replace any blown or damaged fuses only with those of identical 
values.

4

 


background image

  Lamp Installation

Warning

    Remove the power cord before installing the lamp.

5

Please glove your hand to remove the lamp from 
the package in order to keep the lamp life. Insert 
the lamp in the lampholder securely and then put 
back B and A for the complete installation.

Remove the power cord and set the unit as to the 
figure. Loosen the screws with appropriate tools and 
extract A. (See the figure.)

A

B

Loosen the screws with appropriate tools then 
extract B.

If you want to change the lamp, please 
extract the used lamp firstly, then execute 
the above-mentioned processes.

 


background image

a

a

d

Oby-3 can be set on the flat stage floor directly or use clamp to mount on 
any kinds of trusses for fitting the mobility of various venues.

Mount two attached brackets(a) on the bottom (See Figure ), and 
collocate the appropriate clamps(b) to rig with trusses. Must use the 
safety ropes that can hold the ten times as heavy as the fixture through 
the eye bolts(c) on the bottom of the base and trusses; then join the 
safety ropes with screw-on carabines(d).

Rigging:

6

 


background image

Linking

Use 3-pin XLR data cables to link the controller to DMX lighting 
equipment.

3-pin XLR connectors are follows:

Building a serial DMX-chain:

Connect the DMX output of the first fixture with the DMX input of the 
next fixture. And execute all the setups following the above-
mentioned instruction.
Flip the DIP SWITCH #3 of last fixture to  ON  position for terminal 
confirmation.

1

2

3

1

2

3

1:Ground 
2:Signal(-) 
3.Signal(+)

1:Ground 
2:Signal(-) 
3.Signal(+)

DMX-output 

XLR mounting-socket:

DMX-input 

XLR mounting-plug:

7

Connection with the mains

Connect the device to the mains with the power-plug.

The occupation of the connection-cables is as follows:

Cable 

Pin 

International 

Brown 

Live 

Blue 

Neutral 

Yellow/Green 

Earth 

 

 

The earth has to be connected! In general, lighting effects should not
 be connected to dimming-packs.

 


background image

Instructions for  gobo replacement

Please choose the suitable gobo dimensions of this fixture. (Appendix A)

3.Push GOBO & the spring ring out with the 
   fingers carefully.  (*Caution: Avoid falling 
   the spring ring into the fixture.)

Rotating GOBO wheel

4.Insert the new GOBO and the spring ring (*Press the spring ring 
   tight with the appropriate tools in order to keep GOBO compact), 
    screw up the top cover.

DANGER!
Install the gobos with the device switched
off only.

 

Unplug from mains before!

!

8

1.

Loosen the arrow-indicated screws in order with appropriate tools.

2.

Open the top cover.

 


background image

DMX Channel chart

0-255

Gradual adjustment of the dimmer intensity from 0 to 100 %

Channel 1 - Dimmer intensity

Shutter closed

0-7
8-255

Strobe-effect from slow to fast (max. 7 flashes/second)

Channel 2 - Shutter, Strobe

Open/white
Steel Blue
Orange
Green Blue
Bright Blue
Bright Pink
Red
Deep Blue
Yellow
Dark Pink
Moss Green
Light Blue
Color wheel rotation slow to fast

13   
27   
41   
55   
69   
83   
97   
111   
125   
139   
153   
167   
255   

0

14
28
42
56
70
84
98

112
126
140
154
168

Channel 3 - Color wheel 1

Function of the control channels - 16 bit protocol

9

 


background image

10

Channel 4 - Rotating gobo wheel 

Channel 5 - indexing &  Rotating gobo  rotation

Rotating gobo angle 

zero to 360 degrees.  

adjustment from 

 

Forwards gobo rotation from fast to slow
Backwards gobo rotation from slow to fast

127   
191   
255   

0

128
192

4

Channel 6- Prism-wheel

Open position
Triple prism static 
Triple prism  f

orwards rotation from fast to slow

Triple prism  b

ackwards rotation from slow to fast

Triple prism static 

1  
7   
132  
253   
255 

0
2
8

133
254

Channel 7- Focus

Focus adjustment from near to far

255 

0

Channel 8- Pan reguration

CH-11 

 

 The 

head

 of the unit is allowed to turn horizontally from 

             zero to 570 degrees.

5

6

7

8

 


background image

11

Channel 9 Tilt reguration

The 

head

 of the unit is allowed to turn vertically from 

zero to 270 degrees

9

Channel 10 Pan fine-tune  

While rotating horizontally the 

head

 is allowed to be 

fine tuned from zero to 2.2 degrees.

10

Channel 11 Tilt fine-tune  

While rotating vertically the 

head

 is allowed to be

 fine tuned from zero to 1 degree.

11

Channel 12- Reset

Normal state

127 

0

Mechanical reset and re-start after 3 seconds

255 

127

12

Channel 13- Lamp switch

Standby
Lamp "on" 3 seconds later
Standby
Lamp "off" 3 seconds later
Standby

47 
95 
159 
207
255 

0

48
96

160
208

13

 


background image

12

Function of the control channels - 8 bit protocol

DMX 

Channel 

Function 

DIMMER 

SHUT 

COLOR 

GOBO 

GOBO    ROTATE 

PRISM AND ROTATE 

FOCUS 

PAN COARSE 

TILT COARSE 

10 

AUTO RESET 

11 

LAMP ON/OFF 

 

 


background image

Control Board

13

 


background image

Maintenance

Refer maintenance to qualified technicians. Please disconnect power 
and signal wire before maintaining fixtures.

In order to preserve OBY-3 in good condition, keep the routine 
maintenance by following date.

The Steps are as follows:

The dichroic colour-filters, the metal gobo-wheel, the internal lenses 
and cooling fans should be cleaned with soft brush monthly.

The interior of the fixture should be cleaned at least half-yearly using 
a vacuum-cleaner or an air-jet.

Caution:

 Be careful not to damage the interior mechanical structures 

or circuits when using the air-jet.

To ensure a proper function and smooth rotation of the gobo-wheel, 
we recommend lubrication in six-month intervals.

Caution:

 Avoid the damage of interior structures when fixtures 

rotated, do not use excess lubrication.

Due to emit fog frequently, the optical lens and gobos would be oily; 
thus luminosity would be weak. We recommend using moist cloth or a 
trace of detergents to wipe them every two weeks. (Prohibit using the 
detergents consisted of alcohol and solvents.)

14

 


background image

Replacing the Fuse

If the fixture does not function, that may be the fuse was burned out. It 
may be time to replace the fuse of same type and specification for 
eliminating this fault.

Remove the electric power and flip the switch to " off "  position before 
replacing the fuse.

Replace the fuse as follows:

Step 1: Unscrew the screw of the fuse holder on the housing  

counterclockwise with appropriate tools.

Step 2: Remove the broken fuse and then replace the new fuse.

Step 3: Reinsert and tighten the screw on the fuse-holder.

Step 4: Turn the power on for test.

Please contact with the dealer if the fixture still cannot work or the fuse 
burns out again.

Appendix A  

31 mm

31 mm

24 mm

GOBO Size

15

 


background image

Product Specifications

16

 

  
 

  
 

  
 

120V: 8A.   230V: 5A

350VA