TABLE OF CONTENTS 

 

 

1. Safety 

Instruction 

 
 

2. Technical 

Specification 

 
 

3.  How To Set The Unit 

 
 

4.  How To Control The Unit 

 
 

5. Troubleshooting 

 
 

6. Fixture 

Cleaning 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

2- 

  1. Safety Instruction 

 

 

 

WARNING

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

y

  Unpack and check carefully there is no transportation damage before using the unit. 

y

  Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

y

 It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

 The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

y

  Disconnect main power before replacement or servicing.   

y

  Make sure there is no flammable materials close to the unit while operating as it is fire 

hazard.  

y

  Use safety cable when fixes this unit. Don’t handle the unit by taking its head only, but 

always by taking its base.     

y

 Maximum ambient temperature is ta: 40

. Don’t operate it where the temperature is 

higher than this. 

y

  Unit surface temperature may reach up to 85

. Don’t touch the housing bare-hand during 

its operation. Turn off the power and allow about 15 minutes for the unit to cool down 

before replacing or serving. 

y

  In the event of serious operating problem, stop using the unit immediately. Never try to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or 

malfunction. Please contact the nearest authorized technical assistance center. Always 

use the same type spare parts. 

y

 

Do not touch any wire during operation as high voltage might be causing electric shock.

 

Warning 

y

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

y

  Do not open the unit within five minutes after switching off. 

Please read carefully the instruction, which includes important information 

about the installation, usage and maintenance. 

 

3- 

y

 The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly 

damaged. 

Caution 

There are no user serviceable parts inside the unit. Do not open the housing or attempt 

any repairs yourself. In the unlikely event your unit may require service, please contact 

your nearest dealer.

 

Installation 

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit 

is firmly fixed to avoid vibration and slipping while operating. And make sure that the 

structure to which you are attaching the unit is secure and is able to support a weight of 10 

times of the unit’s weight. Also always use a safety cable that can hold 12 times of the 

weight of the unit when installing the fixture.   

The equipment must be fixed by professionals. And it must be fixed at a place where is out 

of the touch of people and has no one pass by or under it. 

 

 

  2. Technical Specification   

 

The unit is DMX 512 fixture. It features full DMX 512 control. It can be also linked together 

in master/slave connection, as many as required and run by built-in program chase 

sequences automatically or by sound activation through an internal microphone to create 

an intelligent effect. 

 It can be operated by DMX 512 control or can be used as an individual unit without a 

controller. 

 Features different preprogrammed chase patterns. 

 Please use a cable when connecting units together. 

 Accurate focusable optics system and ultra smooth stepping motors, Fan cooled. 

 Pan: 540 deg. Tilt: 270 deg. 

 

 Voltage

AC 120V~60Hz/230V~50Hz 

 Power consumption: 55W 

 Dimension: 248x 228 x 330 mm 

 

Light Source: 1×20W LED 

 Weight: 5.6 kg 

     

 


background image

 

4- 

  3. How To Set The Unit   
 
3.1 Main Function   

To select any of the given functions, press the 

MENU

 button up to when the required one is 

showing on the display. Select the function by 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the mode. Once the required mode has been selected, 

press the 

ENTER

 button to setup or it will automatically return to the main functions without 

any change after idling 8 seconds. To go back to the functions without any change press the

 

MENU

 button. The main functions are showing below: 

 

  DMX 512 Address Setting 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press the 

ENTER

 button to setup or automatically 

return to the main functions without any change after 8 seconds. To go back to the functions 

without any change press the

 MENU

 button again. 

 

5- 

    Show Mode 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (show 1) 

or 

 (show 2) or 

 (show 3) or 

  (show 4) mode. Once the mode has 

been selected, press the 

ENTER

 button to setup or automatically return to the main 

functions without any change after 8 seconds. To go back to the functions without any 

change press the

 MENU

 button again. 

   

Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°. 

    Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°. 

    Show 3 mode - Fixture is placed on the speaker, The spot is always projecting 

to the audience’s direction; i.e in front of the stage. Pan movement angel (left to right to 

left): 160°.  Tilt movement angel:  90° (60° above horizon; 30° below horizon.) 

    Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in   

front of the stage. Pan movement angel (left to right to left):160°.    Tilt movement angel: 

90° (vertically, front 75°; back 15°) 

  Slave Mode 

Press the 

MENU

 button up to when the 

 is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 

(normal) or 

 (2 light show) mode. Once the mode has been selected, press the 

ENTER

 button to setup or automatically return to the main functions without any change 

after 8 seconds. To go back to the functions without any change press the

 MENU

 button 

again. 

 Sound Mode 

Press the 

MENU

 button until the 

  is showing on the display. Pressing 

ENTER

 button 

and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

  (sound on) or 

  (sound off) mode. Once the mode has been selected, press the 

ENTER

 button to 

setup or automatically return to the main functions without any change after 8 seconds. To 

go back to the functions without any change press the

 MENU

 button again. 

  Blackout Mode 

Press the 

MENU

 button up to when the 

 is showing on the display. Pressing 

 


background image

 

6- 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 

(yes blackout) or 

  (no blackout) mode. Once the mode has been selected, press the 

ENTER

 button to setup or automatically return to the main functions without any change 

after 8 seconds. To go back to the functions without any change press the

 MENU

 button 

again. 

  Pan Inversion 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) 

or 

 (pan inversion) mode. Once the mode has been selected, press the 

ENTER

 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

 Tilt Inversion 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) 

or 

 (tilt inversion) mode. Once the mode has been selected, press the 

ENTER

 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

  Led Display 

Press the 

MENU

 button up to when the 

 is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 

(Led on) or 

  (Led off) mode. Once the mode has been selected, press the 

ENTER 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

 Display Inversion 

It is good for you to install the unit on the floor or under ceiling. Press the 

MENU

 button up to 

when the 

 

is blinking on the display. Use the 

ENTER

 button to change to the mode   

  (display normal), It will automatically store after 8 seconds. Or press the 

ENTER

 

button again return to the mode 

  (display inversion). To go back to the functions 

press the

 MENU

 button. 

 

Display normal mode for the fixture putting on the floor. 

 

7- 

 

Display inversion mode for the fixture fixing under ceiling. 

  Focus Adjust 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

button to change orientation of the light, then you can turn the plastic lens manually to adjust 

the focus of the unit. To go back to the functions press the

 MENU

 button again. 

    Self-Test

 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

button and the unit will run self-test by built-in program. To go back to the functions press the

 

MENU

 button again. 

 

Temperature Test

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the display will show the temperature of the unit. To go back to the functions 

press the

 MENU

 button again. 

  Fixture Hours 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

button and the display will show the number of working hours of the unit. To go back to the 

functions press the

 MENU

 button again. 

 

Software version

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and the display will show the version of software of the unit. To go back to the 

functions press the

 MENU

 button again. 

    Reset 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 

button and all channels of the unit will return to their standard position. To go back to the 

functions without any change press the

 MENU

 button again. 

 

 

 

 


background image

 

8- 

3.2 Home Position Adjust   
 

 

 

In the main functions, hold 

Enter 

button for at least 3 seconds into offset mode, use 

DOWN

 

and 

UP

 button up to chose 

 or 

, pressing 

ENTER

 button and the display will 

blink. Use 

DOWN

 and 

UP

 button to adjust the home position of the tilt or gobo. Once the 

position has been selected, press the 

ENTER

 button to setup, hold the 

MENU

 button for 

about 3 seconds or wait for 8 seconds to back to the main functions without any change.

 

 

 

  4. How To Control The Unit   

You can operate the unit in three ways: 

 

1. By master/slave built-in preprogram function 

  2. By easy controller 

3. By universal DMX controller 

No need to turn the unit off when you change the DMX address, as new DMX address 

setting will be effected at once. Every time you turn the unit on, it will show 

 on the 

display and move all the motors to their ‘home’ position and you may hear some noises for 

about 20 seconds. After that the unit will be ready to receive DMX signal or run the built in 

programs. 

 

4.1 Master/Slave Built In Preprogrammed Function   

By linking the units in master/slave connection, the first unit will control the other units to 

give an automatic, sound activated, synchronized light show. This function is good when you 

want an instant show. You have to set the first unit in master mode 

 and select 

 (show 1) or 

 (show 2) or 

 (show 3) or 

 (show 4) mode. Its 

DMX input jack will have nothing plugged into it, and Its master LED will be constantly on 

and sound LED will flash to the music. The other units will have to set in slave mode 

 

 

9- 

and select 

 (normal) or 

  (2 light show) mode, Their DMX cables plugged into 

the DMX input jacks (daisy chain) and the slave led lights will constantly on. 

2-light show 

In 

 (slave  mode), 

 means the unit works normally and 

 means 

2-light show. In order to create a great light show, you can set 

  on the second unit to 

get contrast movement to each other, even if you have two units only. 

 

4.2 Easy Controller   

The easy remote control is used only in master/slave mode. By connecting to the 1/4” 

microphone jack of the first unit, you will find that the remote control on the first unit will 

control all the other units functions press the MENU button again. 

 

Stand By 

Blackout the unit 

Function 

1. Sync. Strobe 

2. Async strobe 

3. Sound Strobe 

Show 

1-4 

1. Press to select color

2. Hold to select gobo

Mode 

Sound (LED OFF) 

Show (LED 

Slow Blinking)

LED ON 

 
4.3 DMX Controller   

 

An universal DMX controller to control the units, you have to set DMX address from 1 to 512 

channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the 

DMX512 address. Once the address has been selected, press and keep 

ENTER

 

button pressed up to when the display stops blinking or storing automatically 8 

seconds later. To go back to the functions without any change press the

 MENU

 

button again. If you use please refer to the following diagram to address your 

DMX512 channel for the first 4 units

 

 

 

 

 


background image

 

10- 

4.4 DMX 512 Configuration   

 

 

 

 

4.5 DMX512 Connection   

 

The DMX 512 is widely used in intelligent lighting control, with a maximum of 512 channels. 

 

 

 

11-

1.  If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin 

adapter-cable. 

2.  At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 

1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it 

in the DMX-output of the last unit. 

3.  Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to 

the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is 

a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded 

connectors can easily distort the signal and shut down the system. 

4.  The DMX output and input connectors are pass-through to maintain the DMX circuit, 

when one of the units’ power is disconnected. 

5.  Each lighting unit needs to have an address set to receive the data sent by the 

controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 

6.  The end of the DMX 512 system should be terminated to reduce signal errors. 

7.  3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

 

 

 5. Troubleshooting  

 

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A. The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

 


background image

 

12- 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

C. Some units don’t respond to the easy controller   

1.  You may have a break in the DMX cabling. Check the LED for the response of the 

master/ slave mode signal. 

2.  Wrong DMX address in the unit. Set the proper address. 

D. No response to the sound 

1.  Make sure the unit does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone 

E. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition 

 

 

  6. Fixture Cleaning   

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 

accumulation of dirt on the unit’s optics. 

y

  Clean with soft cloth using normal glass cleaning fluid. 

y

  Always dry the parts carefully. 

y

  Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 

 

 

 

 

 

 

 

 

 

 

13-

 

 

 

 

EC Declaration of Conformity 

 

We declare that our products (lighting equipments) comply with the 

following specification and bears CE mark in accordance with the 

provision of the Electromagnetic Compatibility (EMC) Directive 

89/336/EEC. 

 

EN55014-2: 1997 A1: 2001, EN61000-4-2: 1995; EN61000-4-3: 2002; 

EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6: 1996, 

EN61000-4-11: 1994. 

Harmonized Standard 

 

EN60598-1: 2000+ALL: 2000+A12: 2002 

Safety of household and similar electrical appliances 

Part 1: General requirements 

 

 

 

 

 

 

 

 

 

 

 

Innovation, Quality, Performance