PDF User Manual

  1. Home
  2. Manuals
  3. Eyra AP–17 User Manual

Eyra AP–17 User Manual

Made by: Eyra
Type: User Manual
Category: Battery Charger
Pages: 4
Size: 0.08 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

AP-17 ECS 

EYRA 

 
 
 

INSTRUCTIONS FOR USE

 

  

Inteligent battery charger  AP–17  12V 20A Pb 

 
 

 

 
 
 

Properties: 
- Charger that can "listen" to the chemistry of the battery 
- Fast, smooth and battery friendly charging 
- Battery determines charging current by itself under supervision of 
   microprocessor charging system 
- No warming up effect, which reduces battery life at overcharge 
- Regenerate cells majorly, when they were charged inproperly 
- Long life of battery 
- Ensures up to 110% level of battery default capacity 
- Safe against short circuit 
- Possible charging of starter  battery 
- Connector for attachment of outside led indicator 
- Avtomatical detection of battery attachment (yellow led) 
- Precise indicator of overcharging (green LED) 
- Working temperature range from 0º to 35ºC 
- Charging is independent from oscilations in the supply voltage (PMW technology) 

 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

AP-17 ECS 

1. CHARGING TECHNOLOGY DESCRIPTION 

 

Electrode specific Charging System is new technology of battery charging. It presents a 
small  revolution  on  this  field,  because  the  results  in  practice  are  fantastic.  With  this 
technology  very  fast  and  very  precise  charging  is  possible,  because  only 
electrochemical  position  of  battery  "dictates"  to  the  charger  way  and  current  of 
charging,  which  is  momentarily  proper  for  the  battery.  Charging  with  high  current  is 
accomplished  only  in  phases,  when  cells  can  accept  energy,  without  warming  up  or 
giving off gas. 
 
When charging with this technology is no giving off the gas from electrolyte, warming up 
or sulfatisation. All this processes disintegrates cells of acid battery, so extraordinary 
prolongation of battery life and shortening of charging time is achived. 
 
Teoretically acid battery can be charged with 2,5 time higher current then default 
current is. This means that 100Ah battery can be charged in less then half of hour, if we 
can use current source of 250A. If starter battery is empty, it is possible to start the 
engine after aproximatlly 5 minutes. 
 
We can say that charging  technology works as transformer between battery chemistry 
and signals that commands the charge. Each battery is "treated" individually and from 
here the name "Electrode specific Charging System" is coming. 
 

 
 

 

2. CHARGING INSTRUCTIONS 

 

Accumulator battery charger is suitable for charging only12V acid batteries from 
alltogether capacity of min. 20 Ah. Max. capacity of charged battery in not limited. 
 
2.1 Classical way of connection of charger AP-17  
 
A. For connection to the battery polls (connections) use 4 mm

2  

wire for distances to 1 

m, 6 mm

2

 wire for distances to 2 m, 10 mm

2

 wire for distances to 4 m and 16 mm

2

 wire 

for longer distances. 
B. RED to the + connection of the battery. 
C. BLACK to the - connection of the battery. 
D. Plug in the charger. 
E. Switch on the main supply switcher (POWER) on the side of the charger (small light 
must be on). 
F. At correct connection YELLOW led indicator lights on. 
G. When the battery is full, GREEN led indicator lights on. 
 
Option solution 
H. After 120 seconds GREEN led indicator switches off and YELLOW LED indicator 
switches on again. Battery state is checked and, if necessary, battery is recharged. 
When recharging is finished, GREEN led indicator ligths on again.  
 

 


background image

AP-17 ECS 

WRONG 

 

 

 

 

      CORRECTLY 

  

 

 
 

 

3. CONNECTION OF OUTSIDE INDICATOR 

 

- Mount the control plate and connect it with coaxial cabel as shown on picture right. 
- Connect main supply to one of the fuse on the distribution plate. 
- Interface  for connection of outside indicator is galvanicaly separeted and does not 
influence on the activity of the charger 

 

 

 
 
4.  Conection of AP-17 

 

charger 

 

 

 
 
 
 
 
 
 
 

 

 

 
 
 

 


background image

AP-17 ECS 

 

5.  TECHNICAL DATA 

 

- type of battery:  

 

 

Pb accid with fluid or gel 

- capacity of battery: 

 

 

min 20Ah, maximun is not care 

- battery voltage: 

 

 

12V 

- effective charging current: 

 

20A (pulse) 

- charging mode:  

 

 

Electrode specific Charging System  

- main voltage:    

 

 

195V – 242VAC 

- main voltage frequency: 

 

40 … 60Hz 

- max. power:   

 

 

370 VA 

- ambient temperature:    

 

0

 

°

C do +35

 

°

- short contact output:    

 

not destruction of charger  

- wrong polarity output:    

 

fuse  30A (fuse to burn) 

- main input fuse:  

 

 

T 3,15A 

- cooling of charger:  

 

 

ventilator  

- dimension: 

 

 

 

h:60mm x w: 170mm x d: 245mm

 

- weight: 

 

 

 

1,9 

Kg  

 
Service: 

Eyra elektronika d.o.o., Gabrje pri sti

č

ni 45, SI-1295 Ivan

č

na Gorica, Slovenija ,  tel.: ++386 (0)1 7869 037, 

Fax. .: ++386 (0)1 7869 038,        e-mail: info@eyra-elektronika.si