PDF User Manual

  1. Home
  2. Manuals
  3. Eximia Srl ORCA-50 Manual

Eximia Srl ORCA-50 Manual

Made by: Eximia Srl
Type: Manual
Category: Touch terminals
Pages: 20
Size: 7.33 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

1                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 
 
 
 

ORCA-50 Handheld Data Terminal 

UHF Demo Manual V1.0 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Eximia Srl. 

www.eximia.it

 - www.rfidstore.it 

mario.difloriano@eximia.it

 

 

   

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

2                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

 

 

 

 

 

 

Catelogue 

 

 

1.

 

UHF software operation and configuration.................................................................................... 

        1.1 Start the UHF Demo software................................................................................................. 

1.2 Inventory ISO-18000-6C tag..................................................................................................... 
    1.2.1 Ordinary inventory............................................................................................................ 
    1.2.2 Advanced options............................................................................................................. 
1.3 Access ISO-18000-6C tags....................................................................................................... 
    1.3.1 Read the tag operation.................................................................................................... 
    1.3.2 Write the tag operation................................................................................................... 

            1.3.3 Lock the tag operation ................................................................................................... 

    1.3.4 Inactivation the tag operation.........................................................................................                 
    1.3.5 Select the tag operation................................................................................................... 
    1.3.6 Access the label may return an error message................................................................ 
    1.4 Inventory and access ISO-18000-6B tags............................................................................ 
    1.4.1 Inventory ISO-18000-6B tag............................................................................................ 
    1.4.2 Access ISO-18000-6B tags................................................................................................ 
1.5 RF parameter settings............................................................................................................. 
    1.5.1 Set the RF output power................................................................................................... 
    1.5.2 Set the radio frequency spectrum specification.............................................................. 
    1.5.3 Set the antenna connection to receive............................................................................ 
    1.5.4 Measure the return loss of the current antenna port ..................................................... 
1.6 Other settings of the reader.................................................................................................... 
    1.6.1 Monitor the operating temperature................................................................................ 
    1.6.2 Set the buzzer status........................................................................................................ 
 
 

2.      Develop your own RFID applications........................................................................................... 

 
 

 

 
 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

3                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

©

2017 RodinBell reserves all rights reserved for this document 

 
 

1.

 

UHF software operation and configuration 

 

1.1      Start the UHF Demo software 

Click  the  UHF  Demo  icon  to  enter  the  connection  interface,  select  ttyS1  (rk_serial)  serial  port,  click  on  the 
immediate connection to enter the main interface

 

 

 

 
The main interface for the ISO-18000-6C tag inventory interface

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

4                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

1.2      Inventory ISO-18000-6C label 

Inventory label, which is to identify multiple labels at the same time EPC number, which is the core function of 
UHF RFID reader, its performance directly determines the merits of the reader

   

 

1.2.1 Ordinary inventory 

Click the Start Stock button or trigger the trigger of the handset handle. If the label is within the signal 

range, the EPC data of the label will be uploaded immediately and updated in real time. If you do not click on 
the end of the inventory or release the trigger, the reader will keep the inventory label, as shown below

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

5                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

   

 

The meaning of the data display is as follows

 

Inventoried Quantity  There are a number of different tags that have been archived since the 

start of the inventory butto 

Speed 

Identify the speed of the label in units per second 

Total tag 

A label EPC record as a data, where real-time statistics to return a total 
of  the  number  of  data,  which  contains  repeated  read  the  same  label 
data 

CMD exec time 

The time spent by each inventory command. The unit is milliseconds 

Total duration 

The  total  amount  of  time  since  the  start  of  the  inventory  button  was 
clicked. The unit is milliseconds 

 
The  list  of  tags  in  the  EPC  number  list  (do  not  repeat)  the  meaning  of  the  fields  in  the  list  box  is  as 

follows

 

ID 

The serial number of the data 

EPC 

The EPC number of the label 

PC 

Label protocol control word 

ID CNT 

The number of times the tag was identified 

RSSI 

The signal strength of the label is identified the last time 

Carrier frequency 

Carrier frequency of the label is identified the last time 

 
1.2.2 Advanced options   

Click the Advanced Options checkbox next to the Start Stock button. The following interface appears

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

6                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

 

The number of times each command is stored: 

The meaning of this parameter is the number of times the 

command is repeated. For example, set to 1, each inventory command to perform an anti-collision algorithm. 
Set to 2, then each disk command to repeat the implementation of two anti-collision algorithm, and so on

 

Custom Session parameters: 

Click the Custom Session parameter check box, Session ID and Inventoried Flag 

will become optional, then click the Start button, the reader will be a custom Session and Target inventory

   

 
 

 

1.3    Access ISO-18000-6C tags   

Click the "Access Tag" check box to access the interface of the access label, as shown below

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

7                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

 

The following will be one by one on how to carry out the label access operation

 

 
1.3.1    Read the label operation 

The parameters of the read tag are entered in the interface shown below

 

 

The read tag needs to enter three parameters: the label area to be read, the start address and the data 

length. Note that here the starting address and 

The data length units are WORD, which is 16 bit double bytes. When the parameter is set, click the Read 

tab button. 

It should be noted that the input parameters to meet the specifications of the label, otherwise there will 

be an error

 

 
When the operation completes successfully, the feedback shown below appears

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

8                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

How many tags are displayed and how many pieces of data are displayed in the tag list

 

 

1.3.2    Write the label operation 

Write the interface of the label operation and read operations in the same area, the difference is that 

the write operation also need to provide access to passwords and write data to this information

 

The  password  area  is  part  of  the  electronic  tag  that  stores  the  password  (password).  Including 

inactivation  passwords  and  access  passwords.  The  inactivation  password  and  the  access  password  are  4 
bytes.  Where:  the  address  of  the  inactivation  password  is  00H-03H  (in  bytes);  the  address  of  the  access 
password is 04H-07H

 

 

 
After the operation is successful, the feedback shown below will appear

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

9                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

How many tags have been successfully operated, and how many pieces of data will be displayed in the 

list. Unlike the read tags, there is no content in the data column on the map above. The user can read the 
same area of the tag again to verify that the data is written correctly

 

 

Note that the maximum write length is 32 Word

64 bytes

512bits

)。

 

 

1.3.3    Lock the label operation 

The operation interface of the lock label is shown in the following figure

 

 

The lock tag must be provided with an access password to proceed. 
Note: The original password lock is invalid, it is recommended that users first modify the access password 
and then lock the label

 

 
After the operation is successful, the following information will be returned

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

10                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

Similarly, how many tags are displayed in the list, and how many pieces of data are displayed in the list

 

 

1.3.4    Kill the label operation 

The operation interface of the deactivation tag is shown in the following figure

 

 

The deactivation tag must provide an inactivation password and the inactivation password can not be 00 
00 00 00. Therefore, to destroy a label, first change the contents of the password inactivation password 
by writing a tag command

 

 
After killing tag is successful, the following information is returned

 

 

How many tags are displayed in the list, as with all access to the tag, how many records are displayed in 

the list

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

11                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

1.3.5    Select the label operation 

In many cases, we hope that no matter how many labels in the RF area, only for a known EPC number of 

labels  to  access  operations,  this  time,  you  need  to  use  the  selected  operation  of  the  label  function  (EPC 
matching function)

 

In the accompanying demo software, operate as follows

 

First save the label, get all the EPC number

 

And then go to the interface to access the tag, select the EPC number to match. As shown below

 

 

When the selection is complete, click the selected tab, as shown below

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

12                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

Next, all access label operations will only be performed for labels with this EPC number

 

 

If you want to cancel the EPC match, just click Cancel in the drop-down menu and click the Select button. 

As shown below

 

   

 

 

1.3.6    Access the label may return an error message 

In the process of access to the label operation, if the operation is not correct, there will be an error message, 

then we listed some common operational problems. 

Successful inventory but failed to access

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

13                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

The process of accessing a tag is actually divided into two steps, first by disk, and then accessed. The 

above prompt indicates that the label is successful, but the access operation is not possible

 

In general, there are two reasons for this problem, one is the parameter settings are wrong, such as 

reading does not exist in the storage area, another reason is that the RF energy is not enough, access to the 
operating distance of the label is about the disk operating distance 60% to 70%, so if this is the case, please 
move the label closer to the antenna

 

 

Access password is wrong

 

 

The cause of this problem, as described in the prompt, is that the access password is set incorrectly

 

 

There is no operational label error

 

 

There are no labels available for operation in the RF area

 

 
The meaning of the other return information, the user can refer to the document

UHF_RFID serial interface 

communication protocol _V2.38.pdf

 

 

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

14                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

1.4

盘存和存取

ISO-18000-6B

标签

   

 

1.4.1 

Access ISO-18000-6B tags 

 

ISO-18000-6B label operation and ISO-18000-6C label operation similar to the following figure

 

 

 
Every  time  you  read  the  UID  of  the  label  once,  the  buzzer  will  be  short.  If  the  buzzer  sounds  slightly 

longer, then the reader starts the anti-collision function and simultaneously identifies multiple tags

 

 
 

1.4.2 Access ISO-18000-6B tags 

Access to the leaflet ISO-18000-6B label can only be accessed. Click the Access tab button to select the 

label to be operated in the UID list, as shown in the following figure

   

 

The next operation is relatively simple, the user can operate on their own. Note the following points

 

The access operation must operate the label of the currently selected UID

 

Can read multi-byte tag data at the same time, the length is not limited

 

                 

You can write multi-byte tag data at the same time, the length is not limited. If an error occurs, the 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

15                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

reader stops writing but has already written 

The incoming data will not be changed, and the reader will return the number of bytes successfully 

written

 

Only one byte of card data can be locked at a time

 

Only one byte of data can be queried at a time

 

Locked byte operations are permanent and irreversible

 

 
 

1.5 RF parameter settings 

After successfully connecting the reader, we need to set some of the most basic RF parameters, the output 
power and spectral range

 

The  setting  of  the  RF  parameters  is  set  in  the  reader  settings  ->  RF  parameters  page,  as  shown  in  the 
following figure

 

   

 

1.5.1 Set the RF output power 

RF output power refers to the antenna signal output RF signal strength. The unit is dBm

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

16                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

The output power range is 0dBm - 33dBm. The default value is 30dBm (1 W). After this value is set, it will 
be automatically saved inside the machine, the machine is not lost after power failure

 

 

1.5.2Set the radio frequency spectrum specification 

In different areas, there are different requirements for radio frequency spectrum. 
There are two ways to set the reader's spectrum. 
Method 1: Use the default frequency of the reader. 
The default frequency of the reader can refer to the frequency parameter correspondence table in the 
communication protocol. 
The reader supports a frequency range of 865MHz - 868MHz, 902MHz - 928MHz. 
Use the drop-down boxes and buttons shown below to set the desired operating frequency range

 

 

 

When setting the spectrum range, please note the following points

 

  The starting frequency and end frequency can not exceed the range of RF specifications. 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

17                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

  The starting frequency must be less than or equal to the end frequency. 

  Set the starting frequency and end frequency to the same frequency. The reader will work at constant 

frequency. 
This  parameter  is  set,  the  reader's  RF  carrier  will  be  in  the  restricted  frequency  range  of  random 
frequency hopping. 
The default RF spectrum specification is FCC (902MHz - 928MHz)

 

 
Method 2: user-defined reader spectrum. 
The user uses three parameters to define the spectrum: the starting frequency, the frequency interval, 
the number of frequency points

 

 

Note:  In  order  to  improve  the  anti-jamming  performance,  American  Standard  and  European  standard 
frequency  band  equipment  selected  hardware  is  different,  it  can  not  meet  the  compatible  American 
standard, the European standard two bands

 

 

1.5.3    Set the antenna connection to receive 

Antenna connection to receive the function is: read and write tags before checking whether the port is 

connected to the antenna, if not connected, then notify the user antenna is not connected. 

Before  using  the  user  to  open  this  function,  through  the  interface  shown  below  to  view,  set  the 

interface of this function as shown below

 

 

The sensitivity of the antenna detection is set by the user. Antenna detection sensitivity is the antenna 

port return loss value (Return Loss), the unit is dB. The greater the value, the better the impedance matching 
between the antenna and the port. In general, a normal antenna can set this threshold to 3 - 6 dB. Ceramic 
antenna or handset antenna can reduce the sensitivity lower. If the return loss threshold is set to 0, it means 
that this function is disabled and the status of the antenna connection will not be detected before reading 
and writing the tag. 

If the antenna is not connected, read and write tags when the operation will return to the antenna is 

not connected to the error message

 

 

1.5.4    Measure the return loss of the current antenna port 

The return loss of the antenna port is detected at the interface shown below

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

18                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

 

 

1.6Other settings of the reader 

 

 

1.6.1Monitor the operating temperature 

In the high-intensity continuous use of the reader, it will produce heat, the user can through the built-in 

temperature sensor to monitor the reader internal operating temperature, to avoid overheating (operating 
temperature  of  more  than  65  degrees  Celsius).  If  the  temperature  is  too  hot,  you  can  stop  reading  and 
writing labels for a period of time

 

 

The operating interface for monitoring the temperature is as follows

 

 

 

1.6.2    Set the buzzer status 

The buzzer provides the user with the sound information of the reader's use status. 
The user can turn the buzzer off or set it to sound every time the label is saved. 
It can also be set to sound every time a label is read, but this will result in a reduction in the efficiency of 

multi-tag recognition. This feature is more 

Is applied in the test label or reader occasion

 

 

The operation interface is as follows

 

 

It  should  be  noted  that  the  success  of  the  self-test  after  the  buzzer  sound  is  not  controlled  by  this 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

19                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

setting. 

After setting, the state of the buzzer will keep the FLASH inside and outside the reader, after the power 

is not lost

 

 
 
 
 
 
 

2.

 

Develop your own RFID application 

 

Users  can  use  the  demo  program  to  operate  most  of  the  functions  of  the  reader,  but  in  the  actual 

application environment, it is necessary to develop the user's own program

 

The  accompanying  documentation:  UHF_RFID  serial  interface  communication  protocol  _V2.38.pdf 

provides a complete interface for operating the reader. 

This interface is based on serial communication, so regardless of the user's physical interface is RS - 232 

or TCP / IP, the reader is to follow the definition of this interface

 

Demonstration program provides an important function is the serial port transmission records, the user 

with the communication protocol documentation and demo program operation process of the actual serial 
data to compare, you can quickly grasp the contents of the communication protocol

 

Select the lower right corner of the open serial port monitoring check box, all the uplink and downlink 

serial data will be recorded, as shown below (open the serial port monitoring, the software response speed 
will slow down, so usually should close the serial port monitoring.

 

 


background image

ORCA-50 UHF Demo Manual V1.0 

 

 

 

 

 

 

20                Eximia Srl 

 

www.eximia.it

 - www.rfidstore.it

                                   

 

   

 

Red information for the software to send the data, black information for the UHF module to return to 

the software data. 

Which manually send data function, for users to debug serial port command to use, it has automatically 

calculated check sum function. 

In  addition,  the  accompanying  documentation  also  includes  the  complete  source  code  for  this  demo 

program for user reference, so that applications based on this handheld device can be quickly developed