PDF User Manual

  1. Home
  2. Manuals
  3. Eletrofisher Sum Manual

Eletrofisher Sum Manual

Made by: Eletrofisher
Type: Manual
Category: Fishing Equipment
Pages: 16
Size: 0.43 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

SUM 

Electro-fisher 

Manual 

 
 
 
 

 

 

 

 

Poland 

2017 

 


background image

 

WHAT IS ELECTROFISHING ? 

 

 

Scientists  use  electrofishing  to  survey  fishes  and  monitor 

the  size  of  populations  and  determine  the  species  in  a 
community. Whether using a boat or a backpack electroshocker, 
the  basic  principle  involves  generating  an  electrical  field  in  the 
water to stun fish. When fish are stunned, they often times float 
near  the  surface  of  the  water  and  can  be  removed  from  the 
electrical field. 

How Do Fish Get Stunned? 

 
 

When a fish swims into a weak electrical field, it may not be 

affected at all. There is a threshold of electrical charge that must 
be emitted into the water in order to affect the fish. 
 

When the electrical charge in the water is sufficient to allow 

transport of the charge across the nerve cells in the body, then 
the  fish's  muscles  will  undergo  involuntary  contraction.  The 
contractions will lead to increased exercise of the muscle and a 
build up of lactate in the blood stream. This process is very similar 
to what happens to the muscles of a runner or a swimmer who 
exerts a lot of exercise. The runner or swimmer may eventually 
get a cramp in the muscle and cannot move it effectively. When 
the fish cramps up, it floats to the surface and can be removed 
from the electrical field. The process to stun a fish is usually 5 - 
10 seconds. 
 

Once  the  fish  is  removed  from  the  electric  field,  the  Tidal 

Bass Survey team places the fish in a live well with good aeration. 
The aeration and cool temperatures are essential in the live well 
because the fish has an oxygen debt that needs to be paid. Like 
a  runner  or  swimmer,  the  lactate  in  the  blood  stream  and 
cramping  must  be  treated  with  rest  and  good  oxygen  supply. 
While this period of recovery may take a short time in humans, 

 


background image

 

the recovery time for fish is generally a minimum of 4 hours and 
can range up to 12 hours. 

Are you Stunning All the Fish? 

 

 

Electrofishing is a widespread tool used for surveying black 

bass  because  black  bass  are  generally  easily  stunned  by  the 
electric field. When stunned, all black bass are removed from the 
water.  However,  not  all  black  bass  are  likely  stunned  by  the 
electrofish boat. The electric field quickly weakens with distance 
from the boat and with depth, so many fish in the area are never 
affected. Some fish that have been stunned may even build up a 
tolerance  for  the  electric  field.  Many  species  also  have 
evolutionary adaptations that help them avoid the boat, such as 
a keen lateral sensory system and eyesight. The black bass may 
be able to see the boat coming and swim out of the way of the 
electrical field. Many other species of fish, such as common carp 
or longnose gar, have especially thick scales that protect them 
from the electrical fields. Small fish, such as many minnows and 
killifishes,  have  such  a  small  body  area  that  the  electrical  field 
doesn't affect them. 

What is the Recovery Time? 

 

 

Generally,  fish  recover  almost  immediately  after  they  are 

stunned by an electrofisher. They become oriented in the upright 
position and begin swimming normally within 1 - 2 minutes. To 
fully  recover  from  the  electrofishing,  it  can  take  4  -  12  hours, 
which depends on the amount of lactate in the blood (or the level 
of stress the fish experiences) and habitat conditions. It may take 
also  longer  for  the  fish  to  recover  during  late  summer  when 
dissolved oxygen in the water is low. 

 


background image

 

Connecting the electro-fisher 

 

 

 
 
 

Sockets    plus  and  minus  (see  photo)  serve  to  install  a 

loading of electrofisher. The socket "+" is connected with cable 
on the landing net. The socket "-" is connected with outer cable 
with  metal  wire  at  the  end  (mass/minus)  which  is  thrown  into 
water behind the boat or fisherman.  

 

Cables of 12 Volt power supply are connected to the battery 

"+"  to  "+"  and  "-".  When  user  connects  electrofisher  in  wrong 
order - device will not work. User should correctly connect battery 
to use electrofisher. 

 

Socket "START" designed to connect a cable of steering by 

the  means  of  which  the  electrofisher  is  turned  ON  and  OFF. 
Green indicator shows the presence of high voltage on the outer 
sockets of the electrofisher. 

 

By the 2 knobs and display fisherman regulates and controls 

parameters of the electrofisher.  

 

Knob  F  serve  to  increase  or  decrease  frequency  of  going  out 
impulses in accordance with clock direction. 

 


background image

 

Knob P serve to increase or decrease output power of going out 
impulses in accordance with clock direction. 

 

The electrofishing is quite simple, however, it may seem to 

be very complicated at the first sight. 

 

The most important is to meet all cable connections and the 

electrofishing  device  .  To  connect  correctly  device  we  should 
install first the button of steering on landing net and to connect 
the  high  voltage  cable  into  the  landing  net.  The  button  is  the 
common PRESS-REALEASE button this means that in moment 
of pressing device switches ON and makes possible fishing and 
in moment of releasing the button the electrofisher switches OFF. 

 

This  button  we  install  on  landing  net  -  we  attach  it  with 

isolation to landing net in distances 30-50 cm from end so that 
we  could  easily  operate  the  landing  net  and  switch  on  the 
electrofisher. 

 

This  button  is  connected  with  cables  of  steering  output 

power- if we press the button then the device switches ON- we 
release the button then device switches OFF. 

 

High-voltage cable - (up to 1200 Volt) we can install directly 

to the hoop and to wind its rest on stick or what more comfortable 
to  place  into  the  centre  of  plastic  telescopic  tube  (  handle  of 
landing net). 

 

To  the  socket  OUT  "+"  of  electrofisher  we  connect  outer 

cable which goes to the landing net. This must be installed on the 
plastic landing net and the bare end of a cable must be fixed to 
the metal (aluminium) ring of landing net. The other 2 cm bare 
end we place in the socket OUT"+" . 

 

To  the  outer  socket  OUT  "-"  we  connect  outer  cable  with 

metal wire at the end ( mass/minus) and the metal copper end 

 


background image

 

place  into  the  water  in  the  back  part  of  the  boat  or  we  throw  it 
behind  ourselves  while  electrofishing  in  brooks  or  streams.  To 
the socket START we insert the steering cable to the maximum 
end. 

 

When  electrofisher  is  correctly  connected  we  can  start 

fishing  dipping  the  landing  net  in  water  and  pressing  press-
release  button.  The  (-)  minus  cable  with  metal  wire  at  the  end 
must 

ALSO 

be  dipped  into  the  water.  Fishing  takes  place  by 

periodic/short pressing the button START on landing net while it 
is under water surface. The (-) minus cable with metal wire at the 
end and the cable (+) plus must be in the distance of 3 meters 
and in case of catfishing it can be greater even 20 meters. In this 
moment flow of electric current follows between electrodes and 
executes the fishing.  You should hear silent noise and blinking 
green lamp on the device as well as display showing operating 
parameters.  

 

In  the  course  of  electrofishing  negative  (-)  electrode  is 

placed in water "freely" and positive electrode (anode)(+) serves 
to  active  fishing.  Intensity  of  current  field  is  the  greatest  at 
positive electrode and ąuickly diminishes with the distance from 
it. In regard with this fishes become paralysed in the radius not 
greater  than  2-5  metres  from  anode.  Inertly  flowing  fishes  we 
should pick up ąuickly because in the course of several seconds 
they recover equilibrium and escape at random. 

 

When we catch wading in a river cathode cable we pull near 

behind so that space out between electrodes must be not greater 
than 2-3 metres. 

 

Switching  the  device  by  pressing  START  should  be  no 

longer than for 10 seconds. If the consumed current is lower than 
10 A you can hold on the START button longer and in case of 5 
A you can keep it very long. 

 


background image

 

 

It is not advised to turn the electrofisher very often as fishes 

are shy, especially large, and will escape from big distance if they 
are  outside  of  the  catching  zone.  You  should  turn  the  device 
every  5-10  meters  from  last  fishing  place.  Boating  should  be 
silent and careful in order not to frighten fish. 

 

In the previous paragraph you set the optimum parameters, 

however, in most cases depending on special water conditions, 
weather, season of the year, conductivity of water it is necessary 
to correct these parameters to obtain higher efficiency and better 
effects.  Each  species  of  fish  has  its  own  properties  and  each 
species differently behave in the electric field. 

 

Basic  parameter  which  influences  on  smooth  exit  of  fish 

from  water  is  F-  frequency.  Low  frequency  (  45-50  Hz)  makes 
fish exit to the surface quick and from greater distance. . On the 
contrary,  higher  frequency  causes  smoother  exit  of  fish  on  the 
surface.  Taking  into  consideration  this  you  should  remember  : 
increasing  of  frequency  -slows  down  move  of  the  fish,  while 
decreasing of frequency speeds up. In the summer fish is very 
quick and frequency should be increased. In cool seasons fish is 
more lazy and frequency should be decreased. In the course of 
electrofishing  in  thick  water  flora  it  is  advised  to  lower  the 
frequency in order to enable the fish to overcome all barriers on 
its way towards the landing net. 

 

Usually, frequency is set once and in the course of gaining 

experience and tries fisherman can adjust this value in desired 
direction.  Then  parameters  will  be  corrected  according  to 
changes  of  water  properties  and  other  factors  which  influence 
electrofishing. 

 

You  should  also  know  a  fact  that  changes  in  frequency 

make change in level of output power of electrofisher. Therefore, 
if  you  want  keep  the  previous  power  level  you  should 

 


background image

 

appropriately  correct  the  duration  of  impulses  increasing  their 
length. This is done by the Power knob. 

 

Power  of  output  impulses  influences  exit  of  fish  in  lesser 

level than frequency. If the power is high the fish will start flowing 
up  from  deeper  water  and  sinking  afterwards.  Too  little  power 
level  will  cause  that  fish  will  escape  immediately  if  the  electric 
field  is  not  enough  to  shock  them  and  if  you  press  the  button 
START for too short time. Between maximum and minimum there 
is an optimum level of power which allows, from the point of view 
of smooth exit of fish, to catch them as effectively as possible. 
However, this level should be closer to minimum than maximum 
to keep the battery work longer and cause less stress to fish. 

 

During electrofishing it is possible to take two ways of fixing 

output  power:  medium  power  level  and  periodic  pressing  the 
button START ( no longer than 10 seconds); low power level and 
longer  pressing  the  button  START.  In  the  shallow  waters  the 
power can easily be reduced to as low as 50. 

 

 

 


background image

 

CATFISHING 

 

 

The given model of electrofisher has an option for catching 

catfish  especially  designed  for  that  species.  This  makes 
electrofishing catfish from large distance ( up to 30 meters) and 
deep water - more than 10 meters. Catfish electrofishing is being 
effected  on  very  low  frequency  (F<20).  The  electrofisher 
automatically goes in the state of catfish option if the frequency 
is  lower  than  20  Hz.    Due  to  that  fact  steering  of  electrofisher 
changes and optimum frequency sets between 10 and 15 Hz. 

 

Catfishing  by  the  means  may  take  place  in  large  aquatic 

environments  and  enables  skillful  fisherman  to  catch  large 
quantities of catfish for commercial aims. It is advised to boat in 
the  water  where  the big water holes are present and switching 
electrofisher for up to 10 minutes observing flowing up catfish in 
the distance of 15-20 meters. 

 

After 3-4 fishing you will become experienced operators of 

that  device.  Try  to  find  the  best  parameters  for  your  waters  as 
water properties differ in various regions. 

 

High power level may only cause quick unloading even the 

high capacity battery. In electrofisher high power is required for 
ensuring high reliability only, in order to have greater reserve. 

 

Great role in electrofishing plays knowledge of a given water 

area, places of fish stocking and fish customs. 

SAFETY ISSUES 

 

 

SUM  electrofisher  is  an  absolutely  safe  and  reliable 

electrofishing  device  if  appropriate  electric  safety  issues  are 
known  for  a  user.  It  is  forbidden  to  switch  the  device  and 

 


background image

10 

 

electrofish  in  the  close  exposure  to  bathing  people  or  drinking 
farm animals.  

 

 

 

Watch integrity of isolation of wires of loading and a power 

supply. In case of infringement of a wire it is necessary to replace 
on similar on section with that that were complete with the device. 

 

Periodically check reliability of contact of cable with anode ( 

landing net) as well as power supply cables with battery bolts. 

 

Watch  integrity  of  rubber  band  on  micro-switcher  of  the 

steering  cable  and  in  case  of  damage  change  by  the  home 
means such as : finger of rubber glove or in the end condom. 

 

We guarantee free reparation or replacement of the broken 

device. Our guarantee certificates are not distributed to devices 
with obvious or unauthorised mechanical damages. 

 

 

 


background image

11 

 

 

 

 

During normal work electro-fisher LCD shows 

 
F  

- Frequency    

 

 

[Hz] 

M   - Output power  

 

 

[%] 

U  

- Output voltage  

 

 

[V] 

T  

- Temperature inside  

 

[°C] 

I  

- Battery current  

 

 

[A] 

A  

- Battery voltage  

 

 

[V] 

 
Electro-fisher is equipped with three LEDs 
 

+

-

 Battery status 

Green light  

- Connected battery is charged 

Red light  - Connected battery is discharged (voltage below 10,4 
V) 
 

1200V

 

Green LED indicates the presence of the high voltage on the 
output 
 

 


background image

12 

 

!

 

Short circuit - red LED lights up when worked electro-fisher 
protection. The number of flashes indicates the type of failure 
(error that occurred). Detailed information about problem is 
visible on LCD. 

 

Error no. 1  

Anode and cathode short circuit type 1 
(metallic no. 1) 

Error no. 2 

Temperature inside is above 90°C 

Error no. 3  

Sparks appears at battery clamp 

Error no. 4  

No High Voltage on output (contact service)  

Error no. 5  

Anode and cathode short circuit type 2 
(during switch on) 

Error no. 6  

Anode and cathode short circuit type 3 
(anode and cathode too close) 

Error no. 7  

Anode and cathode short circuit type 4 
(metallic no. 2) 

Error no. 8  

Safety problem (High Voltage present on 
electro-fisher casing) 

Error no. 9 

Processor Hung-up 

Error no. 10 

Safety problem (Water inside electro-fisher) 

Error no. 11  

Input Voltage above 15V  

Error no. 12 

No impulses on MOSFET 1 (contact service) 

Error no. 13 

No impulses on MOSFET 2 (contact service) 

Error no. 14 

Weak battery or battery sulphated 

Error no. 15 

MOSFETs conduct (contact service) 

Error no. 16 

Thyristor Conduct (contact service) 

Error no. 17 

Comparator have got wrong voltage level 
(possible water inside) 

Error no. 18 

MOSFET gate 1 problem (contact service) 

Error no. 19 

MOSFET gate 2 problem (contact service) 

 


background image

13 

 

Error no. 20 

MOSFET gate 1 and 2 problem (contact 
service) 

Error no. 21 

Safety resistor corrupted 

Error no. 22 

Battery voltage below 9V 

Error no. 23 

Sparks at High Voltage output (check anode 
and cathode connectors) 

Error no. 24 

Inside relay 12V is off 

Error no. 25 

Battery voltage between 5V and 6V (probably 
wrong type of battery) 

Error no. 26 

Thyristor conduct current 

Error no. 27 

Non symmetrical MOSFET 1 behaviour 

Error no. 28 

Non symmetrical MOSFET 2 behaviour 

Error no. 29 

Processor supply voltage above 5V 

Error no. 30 

Probably battery charger is connected. It can 
corrupt electrofisher.  

Error no. 31 

Safety resistor corrupted. 

Error no. 32 

Weak battery. High start current. 

Error no. 33 

Safety resistor have short circuit – probably 
water inside electrofisher 

 

LCD Backlight switch OFF 

Display  in  standard  is  illuminated.  If  you  want  to  disable  the 
backlight, press and hold the START button during connection of 
battery. By this you can fish in total darkness. If you want to return 
the display backlight disconnect the battery and reconnect it. 

 

LANGUAGE CHANGE 

Message language can be easily change. 

For ENGLISH 

During connecting of battery  - POWER REGULATION should 
be set at 0% level. 

 


background image

14 

 

For POLISH 

During connecting of battery  - POWER REGULATION should 
be set at 100% level. 

 

Anode examples 

 

 

 

1 - Oversized Round Anode Ring 
2 - Diamond Shaped Anode Ring 
3 - Small Round Anode Ring 
4 - Round Net Anode Ring 
5 - Standard Round Anode Ring 
 

 

 

 


background image

15 

 

SUM electrofisher features 

 
- Input voltage 12 VDC 
- Output voltage 50V-1200V with stabilization 
- Output power 15000W (peak) 
- Output current 128 A (peak) 
- Output frequency 2-100 Hz in 1 Hz step 
- Overcurrent protection 
- Overvoltage protection 
- Electrofisher automatically is switched off when fall in to a 

water 

- Catfish option 
- Soft start function 
- No passwords 
- Battery saver function 
- Automatic battery tester 
- Thermal protection 
- Battery sulfation detector 
- Spark testing protection 
 

 

 


background image

16 

 

 
 

ONE / TWO / THREE YEAR LIMITED WARRANTY 

 

Electrofisher

 

Model 

SUM 

Name 

 

Address 

 

Date of Purchase   
 

Website: www.electro-fisher.net