Introduction: 

 

 

This manual contains: 

1. 

Assembly and installation information. 

2. 

Maintenance information. 

Correct assembly, installation, use and maintenance are very important for safe operation of your 
storage rack system. 

All the users of this storage rack system should read this manual carefully! 

Keep this manual in a visible place, for future reference, retraining and orientation of new users of 
this product. 

 

Guide for the symbols used in this manual: 

 

DANGER  indicates  an  imminently  hazardous  situation  which,  if  not  avoided,  will 
result in death or serious injury. 

 

CAUTION  indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  may 
result in minor or moderate injury. 

 

 

 

Thank you for choosing a Constructor product. 

 

 

 

Read  these  instructions  before  assembling  or  using  your  storage  rack 
system
. To obtain the maximum benefit from any storage rack system, and for the 
safety  of  those  around  the  rack,  the  rack  must  be  properly  assembled  and 
maintained.  The  information  in  this  manual  will  assist  you  in  fulfilling  your 
responsibility to provide a safe, properly maintained storage rack assembly.  

 

 


background image

Issue: 28.05.2013 

P90 VERTICAL STORAGE - SHOWCASE 

|

 

Assembly Information

 

 

Storage  racks  should  be  assembled  only  by  trained  personnel,  experienced 
with proper rack assembly procedures. 

Improper rack  assembly  can  not  only  cause  poor  performance  of  your  system,  but 
can also pose a safety hazard in your facility. 

If you are unfamiliar with rack assembly, you should contact Constructor / Dexion or 
any  authorized  Distributor  for  professional  rack  assembly  services.  Constructor  or 
Dexion  cannot  provide  guarantee  or  warranty  coverage for  any  system  assembled 
by anyone other than a Constructor / Dexion approved Installation Contractor. 

 

It is very important that the rack structure be installed in a square condition. 
Please read the Installation Manual for the Vertical Storage for more details! 

 

 

The  rack  structure  should  be  assembled  and  used  only  as  shown  on 
Constructor / Dexion assembly drawing. 

 

Changing  the  configuration  can  affect  the  load  carrying  capacity  and  reduce  the 
structural  integrity  of  the  rack  system.  Before  adjusting  the  rack  configuration, 
contact  Constructor  /  Dexion  or  the  authorized  Distributor,  to  verify  the  safety  and 
the structural suitability of the new configuration. 

 

„Bolt  and  Nut”  connections  needs  to  be  tightened  to  a  snug  and  secure 
condition.  

 

Safety  locks  must  be  fully  engaged  through  the  beam  end  connector  and 
upright  face  slots.  
These  safety  pins  help  prevent  accidental  dislodgment  of  the 
beams. Beams must not be used with damaged or missing safety pins! 

 

Every frame base must be anchored to an adequate concrete floor. For position 
and number of anchors please see the Installation manual. 

The  normal  anchor  used  by  Constructor  /  Dexion  is  M10x120  Expander  Bolt.  This 
are normally included in the material list. 

Since  anchor  bolts  vary  in  strength,  if  you  are  purchasing  your  own  anchor  bolts, 
contact  Constructor  /  Dexion  or  the  authorized  Distributor  for  minimum  anchor 
specifications for your installation. 

 

 


background image

Issue: 28.05.2013 

P90 VERTICAL STORAGE - SHOWCASE 

|

 

Since  concrete  floors  vary  in  design  and  load  carrying  capacity,  Constructor  / 
Dexion  cannot  guarantee  that  a  particular  concrete  slab  is  adequate  to  support  a 
particular  rack  installation.The  characteristics  of  the  slab  should  be  obtained  from 
the  building  architect  before  the  racks  are  specified,  so  that  the  rack  supplier  can 
design the rack to suit the slab. 

Do  not  install  racks  outdoors,  unless  specifically  designed  by  Constructor  / 
Dexion for this purpose. Outdoor usage requires consideration of wind loads, snow 
loads, etc.., which are not normally considered in an indoor rack design.  

Do  not  expose  your  storage  rack  to  corrosive  or  abrasive  substances  or 
abnormal dampness. 
This may cause deterioration of the surface paint and result 
in  in premature corrosion. Do not store rack products outdoors unprotected! 

 

Be caution when mixing new and existing parts. Even components produced by 
the same manufacturer can vary in design.  

Do  not  mix  parts  from  different  manufacturers  with  Constructor  /  Dexion 
components without review by a qualified engineer.
 Mixing parts may result in a 
less  rigid  structure  that  can  decrease  rack  capacity.  Use  of  Constructor  /  Dexion 
parts  with  parts  from  different  manufacturers  will  also  void  any  warranty  from  our 
part. 

Do not cut, weld or modify rack components. Do not allow any welding or cutting 
of  rack  components  without  Constructor’s  /  Dexion’s  written  authorization.  Such 
modifications may decrease the load capability of the component and damage your 
rack structure, thereby creating a safety hazard. Any modification of any component, 
unless  performed  or  authorized  in  writing  by  Constructor  /  Dexion,  will  void  any 
warranty from our part. 

Installation  of  loading  boards  is  strongly  recommended.  These  boards  should 
identify the characteristics for which the rack was designed, such as load size, load 
weight,  and  rack  configuration.  These  boards  are  very  useful  for  showing  safe 
loading  information  to  both  present  and  future  users.  Several  signs  should  be 
noticeable  located  for  easy  visibility,  and  to  be  permanently  applied  to  the  rack 
structure. 

Never climb on racks, during or after assembly. Storage racks are not designed 
to be stepped on or climbed on. A slip or fall may result in serious injury. It is your 
responsability  to  pass  this  important  warning  to  all  who  come  into  the  proximity  of 
your  storage  rack.  This  can  be  done  by  training  and  appropriate  signage.  If  your 
rack  is  used  in  a  retail  environment,  high  visibility  warning  signs  are  especially 
helpful in preventing this misuse of a storage rack structure. 

Allow adequate aisle spacing. Aisles which are too narrow, or are reduced in size 
by  obstructions  (such  as  temporary  floor  stacking  at  rack  row  ends)  can  cause 
serious injury. 

Install  good  lighthing  in  every    rack  aisle.  Good  lighting  improves  handling 
efficiency, prevents accidents, and reduces accidental damage to the rack structure.  

  

 


background image

Issue: 28.05.2013 

P90 VERTICAL STORAGE - SHOWCASE 

|

 

Operational & Maintenance Information

 

Position  correctly  the  load  on  the  storage  rack  structure  to  prevent  serious 
injury for the users, and damages to the rack structure!
 Bellow, in green border 
is the correct way, for storing goods on this type of racking system. In red borders 
are represented some examples of wrong ways of  placing the goods on the racking 
structure. 

 

 

 

 

 

 

 

The Load must be correctly arranged inside the Tray to be safe against falling! 

For safety reason it is recommended to secure the load! This can be done by gluing 
the load to the tray. 

Perform regularly scheduled inspections (at least annually) and maintenance 
of the rack system. 

 

  Check  for  missing  or  damaged  hardware  including  bolts,  nuts,  and  beam  locking 

devices. Replace any missing or damaged items. Check that all bolts and fasteners are 
snug and tight. 

 

  Check for damage to any components, including beams and columns. Damaged items 

should be repaired or replaced. 

  Check to ensure that all racks are level and square. 

 

  Check to make sure that the rack is being used for its intended purpose. Maintain a set 

of installation drawings on site for review. Check the weight of the product being stored 
to ensure that it does not exceed original design weights. 

 

 

Maintain capacity signs in place. 

 

 

Maintain  good  housekeeping.  Clear,  clean  aisles  are  essential  to  the  safety  of  your 
facility. 

 


background image

Issue: 28.05.2013 

P90 VERTICAL STORAGE - SHOWCASE 

|

 

Replace damaged or missing beam safety pins immediately! Do not use beams 
without safety locks.  

 

Unload  damaged  racks  immediately,  and  contact  Constructor  /  Dexion  or  the 
authorized Distributor for replacement parts (damage reduces capacity, creating the 
potential for collapse and injury). 

 

Check finish, scratches to prevent corrosion.  

 

Do  not  overload  any  rack  component,  bay  or  system.  Your  storage  rack  is 
designed to support a specific load weight, in a specific configuration. If you need to 
store  different  goods  with  changed  weight  or  size,  contact  Constructor  /  Dexion 
before  starting  to  store  the  new  items.  Using  your  rack  in  any  manner  other  than 

originally designed could lead to rack collapse and injury.  

 

Establish  good  housekeeping  practices.  Keep  aisles  clear  of  rubbish  or 
obstructions, do not use aisles for storing goods. Keep aisle surface clean and free 
of ice and condensation. 

 

 

For  any  questions  regarding  assembly,  operation  or  maintenance  of  your 
Constructor  /  Dexion  storage  rack  we  are  at  your  disposal.  Please  contact 
Constructor  /  Dexion  or  the  authorized  Distributor  to  receive  all  the  needed 
assistance.

 

 

 
 
 
 
 
 
 
 
 

Last page 

 

 

SC Dexion Storage Solutions SRL 
Str. Campului nr. 1A, Rasnov 
Jud. Brasov, cod 505400 

T +40 372 683 400 
F +40 372 683 499 

office@dexion.ro 
www.dexion.ro