Customer Documentation 

 
 
 
 
 
 

DEV 2161 (1:4)  
DEV 2162 (1:8)  
DEV 2165 (1:16)  

 
 
 
 
 

CFP Active L-Band Splitters 

 
 
 

 

DEV Systemtechnik GmbH

 

Grüner Weg 4A 

61169 Friedberg 

GERMANY 

Tel: +49 6031 6975 100 

Fax: +49 6031 6975 114 

support@dev-systemtechnik.com 

www.dev-systemtechnik.com 

 

Revision: 2017-12-13 

DEV 91-0094-G 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

TABLE OF CONTENTS 

1

 

REVISION HISTORY ------------------------------------------------------------------------------ 3

 

2

 

INTRODUCTION ----------------------------------------------------------------------------------- 3

 

2.1

 

Warranty ---------------------------------------------------------------------------------------------- 3

 

2.2

 

Limitation of Warranty ----------------------------------------------------------------------------- 4

 

3

 

PRODUCT DESCRIPTION ---------------------------------------------------------------------- 4

 

3.1

 

Features and Options ------------------------------------------------------------------------------ 4

 

3.1.1

 

Splitter Units ----------------------------------------------------------------------------------------- 4

 

3.1.2

 

Additional Splitter Unit Options ------------------------------------------------------------------ 5

 

3.2

 

Product Drawings ----------------------------------------------------------------------------------- 5

 

3.2.1

 

DEV 2161 with 3 * Option 30 --------------------------------------------------------------------- 5

 

3.2.2

 

DEV 2162 with 3 * Option 31 --------------------------------------------------------------------- 6

 

3.2.3

 

DEV 2165 with Option 32 ------------------------------------------------------------------------- 6

 

4

 

INSTALLATION INSTRUCTIONS ------------------------------------------------------------- 7

 

4.1

 

Scope of Delivery ----------------------------------------------------------------------------------- 7

 

4.2

 

Installation of the Product ------------------------------------------------------------------------- 7

 

4.2.1

 

Mechanical Integration of the Product in a 19" Rack --------------------------------------- 7

 

4.2.2

 

Grounding and Power Connection -------------------------------------------------------------- 7

 

4.2.3

 

Connection of RF Signal Cables ---------------------------------------------------------------- 8

 

4.3

 

Maintenance of the Product ---------------------------------------------------------------------- 8

 

5

 

OPERATION OF THE PRODUCT ------------------------------------------------------------- 9

 

5.1

 

Operation via the Device Panel ----------------------------------------------------------------- 9

 

6

 

CONNECTORS ------------------------------------------------------------------------------------- 9

 

7

 

TECHNICAL DATA AND OPTIONS ----------------------------------------------------------- 9

 

8

 

SPARE PARTS ------------------------------------------------------------------------------------- 9

 

9

 

CONFORMANCE DECLARATIONS -------------------------------------------------------- 10

 

9.1

 

Certificate of Conformance --------------------------------------------------------------------- 10

 

9.2

 

Certificate of Conformance External Power Supply -------------------------------------- 12

 

9.3

 

EU Declaration of Conformity ------------------------------------------------------------------ 13

 

10

 

GLOSSARY ---------------------------------------------------------------------------------------- 14

 

11

 

NOTES ---------------------------------------------------------------------------------------------- 14

 

 
 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 

 Copyright DEV Systemtechnik GmbH 2011-2017 

REVISION HISTORY  

Revision (Date) 

Author  Short Description 

A (11-Nov-2011)  WP 

Initial version 

B (01-Dec-2011)  WP 

Minor corrections 

C (11-Jan-2012) 

WP 

Minor corrections 

D (07-Aug-2012)  WP 

Integration of data sheet & minor corrections 

E (09-Jul-2013) 

WP 

Integration of DEV 2165 

F (11-Mar-2015) 

WP 

Documentation update 

I (13-Dec-2017) 

WP 

Minor changes 

 
 

INTRODUCTION  

Thank you for purchasing a DEV 216x Active L-Band Splitter.  
This  customer  documentation  is  intended  to  familiarize  you  with  the 
installation and operation of the device. 

The  DEV 216x  is  a  series of active 1:4, 1:8, or  1:16 L-Band splitters, which 
are  especially  developed  for  digital  television  and  broadcasting  applications 
and  which  are  designed  for  the  use  in  ground  stations  and  cable  TV  head 
end  stations  to  distribute  high  frequency  signals  to  satellite  receivers  or 
IRDs.  All  products  of  this  series  are  delivered  in  a  rack  mountable  1 RU 
chassis and are equipped with one to four splitter units.  

The DEV 216x are members of the DEV Core Function Products (CFP) line. 
Compared with DEV standard products  the Core Function Products provide 
the  same  superior  RF  transmission  quality  without  certain  features  such  as 
integrated  redundant  power  supplies,  monitoring  ports,  RF  sensing,  and 
other alarm functionality.  

DEV  Systemtechnik  GmbH  declares  that  this  equipment  meets  all  relevant 
standards and rules. The product carries a CE mark. 

Please read all instructions before installation or usage of the product!

 

2.1 

WARRANTY  

The product has a warranty against defects in material and workmanship for 
a period of two years from the date of shipment. During the warranty period 
DEV Systemtechnik will, at its option, either repair or replace the product if it 
turns out to be defective. 

For  warranty,  service,  or  repair,  the  product  must  be  returned  to  DEV 
Systemtechnik.  The  customer  has  to  pay  shipping  charges  to  DEV 
Systemtechnik  and  DEV  Systemtechnik  will  pay  shipping  charges  to  return 
the  product  to  the  customer.  However,  the  customer  is  obliged  to  pay  all 
duties,  all  taxes,  and  all  other  additional  costs  arising  from  the  shipment  of 
the product. 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

2.2 

LIMITATION OF WARRANTY  

The preceding warranty does not apply to defects resulting from:  

  improper site preparation or site maintenance;  

  improper or inadequate interfacing of the product;  

  unauthorized modification or misuse of the product;  

  improper or inadequate maintenance of the product;  

  operation beyond the environmental conditions specified for the product. 

Warning:

 

Disconnect  the  device  from  any  external  power  line  before  opening  of  the 
housing.  In  any  case,  the  device  is  to  be  opened  by  especially  trained 
people, only. 
 
 

PRODUCT DESCRIPTION  

The DEV 2161, the DEV 2162, and the DEV 2165 are active splitters for the 
frequency range 500…2300 MHz. By default, each product is equipped with 
a single splitter  unit with either 4 output ports (DEV 2161), or 8 output ports 
(DEV 2162),  or  16 output  ports  (DEV 2165).  Optionally,  the  DEV 2165  can 
be  ordered  with  one  additional  splitter  unit;  and  the  DEV 2161  and  the 
DEV 2162 can be ordered with up to three additional splitter units.  
The  splitter  units  provide  a  switchable  LNB  power  (or  bias)  supply;  i.e.  the 
DC  supply  of  LNBs  or  of  inline  amplifiers  can  be  realized  through  the  RF 
input port of the splitter unit.  

3.1 

FEATURES AND OPTIONS  

3.1.1 

Splitter Units  

B ia s

P w r

1 .C

1 .1

1 .2

1 .3

C

S P

B

1

2

3

1 .4

1 .5

1 .6

1 .7

1 .8

4

B ia s

P w r

1 .C

1 .1

1 .2

1 .3

C

S P

B

1

2

3

1 .4

1 .5

1 .6

1 .7

1 .8

4

5

6

7

8

B ia s

P w r

1 .C

1 .1

1 .2

1 .3

C

S P

B

1

2

3

1 .4

1 .5

1 .6

1 .7

1 .8

4

5

6

7

8

B ia s

P w r

2 .C

2 .1

2 .2

2 .3

2 .4

2 .5

2 .6

2 .7

2 .8

9

1 0

1 1

1 2

1 3

1 4

1 5

1 6

 

S

 

Splitter unit 1: Bias (or LNB power) push button 

P

 

Splitter unit 1: Power LED 

B

 

Splitter unit 1: Bias (or LNB power) LED 

C

 

Splitter unit 1: Common input port; 75 Ohm, precision F(f) 

1…4

 

Splitter unit 1: Output ports 1…4; 75 Ohm, precision F(f)

 

5…8

 

Splitter unit 1: Output ports 5…8; 75 Ohm, precision F(f) (DEV 2162 and DEV 2165 only)

 

9…16

 

Splitte

r unit 1: Output ports 9…16; 75 Ohm, precision F(f) (DEV 2165 only)

 

 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 

 Copyright DEV Systemtechnik GmbH 2011-2017 

A splitter unit consists of the common input port (

C

) and for the DEV 2161 of 

four  (

1…4

),  for  the  DEV 2162  of  eight  (

1…8

),  and  for  the  DEV 2165  of 

sixteen (

1…16

) output ports. A green power LED (

P

) is provided to indicate 

that the splitter unit is supplied with power. A splitter unit is capable to deliver 
LNB  power  (or  bias)  to  the  common  input  port.  The  bias  (or  LNB  power) 
push  button  (

S

)  is  used  to  turn  on or  off the  LNB power  (or  bias) supply. A 

ballpoint pen is recommended to operate the push button. If the  LNB power 
supply is turned off, the bias (or LNB power) LED (

B

) is off. If the LNB power 

supply is turned on the LED is green. 

3.1.2 

Additional Splitter Unit Options  

By default a DEV 216x is equipped with a single splitter unit.  
By  ordering  the  corresponding  number of Option 30 for  the DEV 2161 or  of 
Option 31  for  the  DEV 2162,  the  products  are  delivered  with  one  to  three 
additional splitter units.  
By  ordering  Option 32  for  the  DEV 2165,  the  product  is  delivered  with  a 
second splitter unit.  
 

3.2 

PRODUCT DRAWINGS  

The  layout  of  the  different  products  is  almost  identical.  In  the  following,  the 
DEV 2161,  the  DEV 2162,  and  the  DEV 2165  are  shown  in  their  maximum 
configuration, i.e. with four (or two) splitter units installed. The appearance of 
smaller configurations can be easily derived from these illustrations.  

3.2.1 

DEV 2161 with 3 * Option 30  

Front View: 

1 :4  A c tiv e  L -B a n d  S p litte r

D E V  2 1 6 1

 

Rear View: 

B ia s

B ia s

B ia s

B ia s

P w r

P w r

P w r

P w r

1 .C

1 .1

1 .2

1 .3

1 .4

1 .5

1 .6

1 .7

1 .8

3 .C

3 .1

3 .2

3 .3

3 .4

3 .5

3 .6

3 .7

3 .8

2 .C

2 .1

2 .2

2 .3

2 .4

2 .5

2 .6

2 .7

2 .8

4 .C

4 .1

4 .2

4 .3

4 .4

4 .5

4 .6

4 .7

4 .8

G

C

L

E

1

P

3

2

4

E th e rn e t

+

1 8  V  D C

-

5 0  V A

 

G

 

Grounding bolt

 

P

 

DC power inlet

 

C

 

Power cable support fixture

 

L

 

Serial number label

 

E

 

Fixture for Ethernet connector (not equipped for this type of product)

 

3

 

Splitter unit 3 (equipped only with 2 * (or more) Option 30) 

1

 

Splitter unit 1 (always equipped)

 

4

 

Splitter unit 4 (equipped only with 3 * Option 30) 

2

 

Splitter unit 2 (equipped only with 1 * (or more) Option 30) 

 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

3.2.2 

DEV 2162 with 3 * Option 31  

Front View: 

1 :8  A c tiv e  L -B a n d  S p litte r

D E V  2 1 6 2

 

Rear View: 

B ia s

B ia s

B ia s

B ia s

P w r

P w r

P w r

P w r

1 .C

1 .1

1 .2

1 .3

1 .4

1 .5

1 .6

1 .7

1 .8

3 .C

3 .1

3 .2

3 .3

3 .4

3 .5

3 .6

3 .7

3 .8

2 .C

2 .1

2 .2

2 .3

2 .4

2 .5

2 .6

2 .7

2 .8

4 .C

4 .1

4 .2

4 .3

4 .4

4 .5

4 .6

4 .7

4 .8

G

C

L

E

1

P

3

2

4

E th e rn e t

+

1 8  V  D C

-

5 0  V A

 

G

 

Grounding bolt

 

P

 

DC power inlet

 

C

 

Power cable support fixture

 

L

 

Serial number label

 

E

 

Fixture for Ethernet connector (not equipped for this type of product)

 

3

 

Splitter unit 3 (equipped only with 2 * (or more) Option 31) 

1

 

Splitter unit 1 (always equipped)

 

4

 

Splitter unit 4 (equipped only with 3 * Option 31) 

2

 

Splitter unit 2 (equipped only with 1 * (or more) Option 31) 

 

3.2.3 

DEV 2165 with Option 32  

Front View: 

1 :1 6  A c tiv e  L -B a n d  S p litte r

D E V  2 1 6 5

 

Rear View: 

B ia s

B ia s

B ia s

B ia s

P w r

P w r

P w r

P w r

1 .C

1 .1

1 .2

1 .3

1 .4

1 .5

1 .6

1 .7

1 .8

3 .C

3 .1

3 .2

3 .3

3 .4

3 .5

3 .6

3 .7

3 .8

2 .C

2 .1

2 .2

2 .3

2 .4

2 .5

2 .6

2 .7

2 .8

4 .C

4 .1

4 .2

4 .3

4 .4

4 .5

4 .6

4 .7

4 .8

G

C

L

E

1

P

3

2

4

E th e rn e t

+

1 8  V  D C

-

5 0  V A

 

P

 

DC power inlet

 

C

 

Power cable support fixture

 

L

 

Serial number label

 

E

 

Fixture for Ethernet connector (not equipped for this type of product)

 

3

 

Splitter unit 2, common port & 

output ports 1…8 (equipped only with Option 32) 

1

 

Splitter unit 1, common port & 

output ports 1…8 (always equipped)

 

4

 

Sp

litter unit 2, output ports 9…16 (equipped only with Option 32) 

2

 

Splitter unit 1, output ports 9…16 (always equipped) 

 

 
 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 

 Copyright DEV Systemtechnik GmbH 2011-2017 

INSTALLATION INSTRUCTIONS  

4.1 

SCOPE OF DELIVERY  

1 *  DEV 2161 or DEV 2162 or DEV 2165  
 

equipped with 

 

 

  additional splitter unit option(s)  

 

as ordered 

1 *  DEV 79-0163 external power supply

 

1 *  Customer documentation (this document) 

 

 

4.2 

INSTALLATION OF THE PRODUCT  

4.2.1 

Mechanical Integration of the Product in a 19" Rack  

For  the  integration  in  a  19" rack,  the  rack  slots  must  be  prepared  with  rails 
for  the  1 RU  chassis.  After  inserting  the  chassis  in  the  rack,  fix  the  chassis 
with four screws to the rack at its rack mount flanges. 

Warning: 

  It is absolutely not permitted to fix the chassis on the rack mount flanges, 

only. 

4.2.2 

Grounding and Power Connection  

The  chassis  needs  to  be  connected  to  the  19"  rack  via  a  ground  wire.  The 
grounding bolt (

G

) is located on the left at the rear side of the product:  

G

C

L

E

P

E th e rn e t

+

1 8  V  D C

-

5 0  V A

 

To  connect  the  grounding  cable,  please  take  off  the  upper  nut and the first 
washer  of the grounding bolt (

G

). Then connect the grounding cable, which 

must  have  a  ring  tongue  terminal  matching  for  the  M4  fastening  bolt.  The 
washer and the nut have to be tightened again. 

The  external  power  supply  delivered  with  the  product  has  to  be  suitably 
stowed  away  within  the  rack  in  a  way,  that  it  is  firmly  fixed,  that  the  DC 
output cable of the external power supply is in reach of the chassis, and that 
the applied primary power cord is in reach of the external power supply and 
of  the  available  electrical  outlet.  First  connect  the  DC  output  cable  of  the 
external  power  supply  to  the  DC  power  inlet  (

P

)  of  the  chassis;  a  cable 

fixture  (

C

)  is  provided  for  this  cable  to  avoid  unintentional  disconnection. 

Then connect a power cord on one side to the external power supply and on 
the other side to the available electrical outlet. 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

Note:

 

  It is 

highly recommended

 to power up the device after the installation of 

all RF signal cables (please refer to chapter 4.2.3). 

4.2.3 

Connection of RF Signal Cables  

Please  refer  to  chapter 3.1.1  for  the  functionality  of  the  different  RF  signal 
connectors on a splitter unit and to chapter 3.2 for the location and naming of 
the single splitter units.  

Apply strain relieves to the external RF cables which are to be connected in 
a way that the connectors of the device are not stressed mechanically. 

If  the  DEV 216x  is  powered  up  already  and  before  the  RF cables  are  to  be 
connected to the chassis, the LNB power (or bias) supply of all splitter units 
is  to  be  turned  off!  Otherwise,  there  is  a  risk  that  a  high  impulse  current 
degrades the RF performance of the corresponding input connector. 

First, connect the RF input cable(s) (e.g. from the LNB) to the corresponding 
input  port(s);  then  connect  the  RF  output  cables  (to  the signal receivers) to 
the output ports.  

When  connecting  RF cables  to  the  chassis,  each  connector  is  to  be 
tightened with a torque wrench. The torque applied to 75 Ohm F connectors 
should not exceed 4.5 Nm (39.8 lbf-in).  

Note:

 

  For  the  products  of  this  series,  female  precision  F connectors  are 

applied.  Make  sure,  that  the  applied  connectors  are  male  precision 
F connectors (with thin inner conductor). 

  Each  unused  output  port  of  a  splitter  unit  has  to  be  terminated  with  a 

75 Ohm F load to achieve best amplitude frequency response. 

  Recommendation for the output wiring of a splitter unit:  

Best  signal  quality  is  achieved  by  connecting  the  signal  receivers 
symmetrically to the outputs:  
•  1…4 of each 1:4 splitter unit;  
•  1…4 and 5…8 of each 1:8 splitter unit;  
•  1…4, 5…8, 9…12, and 13…16 of each 1:16 splitter unit;  

and

 by connecting impedance matched loads to the unused ports. 

  If all cables are connected, the device can be powered up.  

Now  the  LNB  power  (or  bias)  supply  can  be  turned  on  for  the  splitter 
units that are required to feed power to an LNB. 

 

4.3 

MAINTENANCE OF THE PRODUCT  

The product is maintenance-free.  
Cleaning  of  the  surface  of  the  chassis  should  be  done  carefully  with  a  dry 
lint-free cloth. 
 
 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 

 Copyright DEV Systemtechnik GmbH 2011-2017 

OPERATION OF THE PRODUCT  

After  going  through  the  installation  steps  as  described  above,  the  device  is 
ready to use.  

5.1 

OPERATION VIA THE DEVICE PANEL  

Beside  the  bias  (or  LNB  power)  push  button(s)  (please  refer  to  chapter 
3.1.1),  there  is  (are)  no  element(s)  to  be  operated.  The  operating  status  of 
each  splitter  unit  and  of  each  LNB  power  (or  bias)  supply  is  indicated  via 
LEDs, which were already described in chapter 3.1.1 as well. 
 
 

CONNECTORS  

AC Power Plug (at the external power supply)

 

Connector: 

IEC rubber connector (male) IEC 60320 C14

 

Connector screws: 

none

 

AC Power Plug

 

Pin 

Functionality 

Pin 1 

L (Live/Phase) 

Pin 2 

PE (Protective Earth) 

Pin 3 

N (Neutral) 

 

DC Connector Plug (at the chassis)

 

Connector: 

DC coaxial connector plug for connector with  

 

OD (Outer Diameter):  5.5 mm (0.22") &  

 

ID (Inner Diameter): 

2.1 mm (0.08")

 

Connector screws: 

none

 

DC Connector Plug

 

Pin 

Functionality 

Pin 1 (inner) 

positive DC-Voltage  
(+18 V nominal) 

Pin 2 (outer) 

GND 

 

 
 

TECHNICAL DATA AND OPTIONS  

The technical data and the options are stated in the data sheet; please refer 
to 

www.dev-systemtechnik.com

 
 

SPARE PARTS  

External power supply; 18 V DC, 60 W 

DEV 79-0163 

 
 

1

2

3

1

2

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

10 

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

CONFORMANCE DECLARATIONS  

This  chapter  comprises  the  Certificate  of  Conformance  for  the  products 
which  are  subject  of  this  customer  documentation  (chapter 9.1),  the 
Certificate  of  Conformance  for  the  external  power  supply (chapter 9.2), and 
the EU Declaration of Conformity (chapter 9.3). 
 

9.1 

CERTIFICATE OF CONFORMANCE  

Since  DEV Systemtechnik  develops  and  produces  in  Germany,  the 
Certificate of Conformance for each product or product series is to be issued 
in German (as stated on the next page).  

For  the  ease  of  comprehension,  the  harmonized  standards  that  were  taken 
into  consideration  during  development  and  production  are  listed  here  in 
English: 

DIN EN 50083-2:2016-03  Cable networks for television signals, sound signals and interactive services -  
 

Part 2: Electromagnetic compatibility for equipment;  

 

German version EN 50083-2:2012 + A1:2015 

DIN EN 55022:2011-12 

Information technology equipment - Radio disturbance characteristics -  

 

Limits and methods of measurement  

 

(CISPR 22:2008, modified); German version EN 55022:2010 

DIN EN 55024:2016-05 

Information technology equipment - Immunity characteristics -  

 

Limits and methods of measurement  

 

(CISPR 24:2010 + Cor.:2011 + A1:2015); German version EN 55024:2010 + A1:2015 

DIN EN 61000-3-2:2015-03 Electromagnetic compatibility (EMC) - Part 3-2: Limits -  
 

Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) 

 

(IEC 61000-3-2:2014); German version EN 61000-3-2:2014 

DIN EN 61000-3-3:2014-03 Electromagnetic compatibility (EMC) - Part 3-3: Limits -  
 

Limitation of voltage changes, voltage fluctuations, and flicker in public low-voltage  

 

supply systems, for equipment with rated cur

rent ≤16 A per phase and not subject to  

 

conditional connection 

 

(IEC 61000-3-3:2013); German version EN 61000-3-3:2013 

DIN EN 62368-1:2016-05  Audio/video, information and communication technology equipment -  
 

Part 1: Safety requirements  

 

(IEC 62368-1:2014, modified + Cor.:2015);  

 

German version EN 62368-1:2014 + AC:2015 

 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 

 Copyright DEV Systemtechnik GmbH 2011-2017 

11 

Konformitätserklärung nach  

EMV-Richtlinie (2014/30/EU)  

Niederspannungsrichtlinie (2014/35/EU) 

 
Der Hersteller: 

DEV Systemtechnik GmbH 

 

Grüner Weg 4A 

 

61169 Friedberg 

 
erklärt  hiermit  in  alleiniger  Verantwortung,  dass  nachfolgend  bezeichnete  Produkte  in  denen  von  uns  in 
Verkehr gebrachten Ausführungen: 
 
Bezeichnung der Produkte: Aktive L-Band Splitter 1...4 * 1:4, 1...4 * 1:8 oder 1...2 * 1:16  

Produktnummern 

DEV 2161 (1:4), DEV 2162 (1:8), DEV 2165 (1:16)  

Baujahr: 

ab 2011  

 
auf die sich diese Erklärung bezieht, mit den folgenden Normen übereinstimmen. 
 
Bei  der  Konzipierung  und  beim  Bau  der  Geräte  wurden  die  folgenden  harmonisierten  Normen 
berücksichtigt: 
 
DIN EN 50083-2:2016-03  Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste -  
 

Teil 2: Elektromagnetische Verträglichkeit von Geräten;  

 

Deutsche Fassung EN 50083-2:2012 + A1:2015 

DIN EN 55022:2011-12 

Einrichtungen der Informationstechnik - Funkstöreigenschaften -  

 

Grenzwerte und Messverfahren  

 

(CISPR 22:2008, modifiziert); Deutsche Fassung EN 55022:2010 

DIN EN 55024:2016-05 

Einrichtungen der Informationstechnik - Störfestigkeitseigenschaften -  

 

Grenzwerte und Prüfverfahren  

 

(CISPR 24:2010 + Cor.:2011 + A1:2015); Deutsche Fassung EN 55024:2010 + A1:2015 

DIN EN 61000-3-2:2015-03 Elektromagnetische Verträglichkeit (EMV) - Teil 3-2: Grenzwerte -  
 

Grenzwerte für Oberschwingungsströme (Geräte-Einga

ngsstrom ≤16 A je Leiter) 

 

(IEC 61000-3-2:2014); Deutsche Fassung EN 61000-3-2:2014 

DIN EN 61000-3-3:2014-03  Elektromagnetische Verträglichkeit (EMV) - Teil 3-3: Grenzwerte -  
 

Begrenzung von Spannungsänderungen, Spannungsschwankungen und Flicker in  

 

öffentlichen Niederspannungs-Versorgungsnetzen für Geräte mit einem  

 

Bemessungsstrom ≤16 A je Leiter, die keiner Sonderanschlussbedingung unterliegen 

 

(IEC 61000-3-3:2013); Deutsche Fassung EN 61000-3-3:2013 

DIN EN 62368-1:2016-05  Einrichtungen für Audio/Video-, Informations- und Kommunikationstechnik -  
 

Teil 1: Sicherheitsanforderungen  

 

(IEC 62368-1:2014, modifiziert + Cor.:2015);  

 

Deutsche Fassung EN 62368-1:2014 + AC:2015 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
DEV Systemtechnik GmbH 

_____________________________ 

Friedberg, 13.12.2017 

Jörg Schmidt 

 

Managing Director 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

12 

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

9.2 

CERTIFICATE OF CONFORMANCE EXTERNAL POWER SUPPLY  

 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

 

 Copyright DEV Systemtechnik GmbH 2011-2017 

13 

9.3 

EU DECLARATION OF CONFORMITY  

As original manufacturer of Electrical & Electronic Equipment (EEE) 
 
DEV Systemtechnik GmbH 
Grüner Weg 4A 
61169 Friedberg 
GERMANY 
 
declares under sole responsibility that the 
 
Products: 
DEV 2161 

CFP 1:4 Active Splitter; 500…2300 MHz; 75 Ohm, F (f)  

  
DEV 2162  CFP 1:8 

Active Splitter; 500…2300 MHz; 75 Ohm, F (f)  

  
DEV 2165  CFP 1:16 

Active Splitter; 500…2300 MHz; 75 Ohm, F (f)  

 
Options: 
•  30 (for DEV 2161);  
•  31 (for DEV 2162);  
•  32 (for DEV 2165);  
•  and future options  
 
 
to which this declaration refers to, is in conformity with Directive 2011/65/EU of the European Parliament 
and  of  the  Council  of  8-Jun-2011  on  the  restriction  of  the  use  of  certain  hazardous  substances  in 
electrical and electronic equipment (RoHS). 
 
Signed for and on behalf of DEV Systemtechnik GmbH 
 
Name: 

Jörg Schmidt 

 
Position: 

Managing Director 

 
Place and date of issue:  Friedberg, 13-Dec-2017 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Signature: 

 


background image

Customer Documentation DEV 2161, DEV 2162, DEV 2165  

14 

 Copyright DEV Systemtechnik GmbH 2011-2017 

 

10 

GLOSSARY  

AC 

A

lternating 

C

urrent 

CFP 

C

ore 

F

unction 

P

roducts  

(product line within the DEV Systemtechnik product portfolio) 

DC 

D

irect 

C

urrent 

IRD 

I

ntegrated 

R

eceiver 

D

ecoder; also simply referred to as "receiver" 

LED 

L

ight 

E

mitting 

D

iode 

LNB 

L

ow 

N

oise 

B

lock Converter 

RF 

R

adio 

F

requency 

RU 

R

ack 

U

nit: Units of vertical height. 1 RU = 1 ¾" = 44.45 mm 

Sometimes simply referred to as "U" (Unit). 

 
 

11 