background image

4693-4698

INSTALLATION MANUAL

 


background image

INSTALLATION MANUAL  4693-4698

2

Summary

1. KIT CONTENTS ............................................................................................................................................................3

2. INTRODUCTION & INSTALLATION METHODOLOGY (how to access to the vehicle speci

fi

 c technical documents) ...3

3. SYSTEM’S CONFIGURATION ......................................................................................................................................3

4. HOW TO PREPARE THE PIN CODE CARD ................................................................................................................4

5. INSTALLATION PROCEDURE .....................................................................................................................................5

 - ELECTRIC DIAGRAMS

6. ACTIVE FUNCTIONALITIES (descriptions) ................................................................................................................16

7. PROGRAMMABLE FUNCTIONS 

(see the “Functions programming tables” manual)

 .........................................18

8. NEW REMOTE CONTROLS AND / OR DRIVER CARDS (optionals) SELF LEARNING PROCEDURE 

(see ‘PAGE 2’ of the “Functions programming tables” manual)

 ...............................................................................18

9. FUNCTIONAL TEST ....................................................................................................................................................18

10. SELF LEARNING PROCEDURE REQUIRED TO REPLACE THE MAIN UNIT OR THE WIRELESS SIREN 
REPLACEMENT ..............................................................................................................................................................18

11. DOCUMENTS HANDOVER ......................................................................................................................................19

12. SYSTEM TECHNICAL SPECIFICATIONS ................................................................................................................19

13. UK MARKET ..............................................................................................................................................................19

 


background image

INSTALLATION MANUAL  4693-4698

3

1. - KIT CONTENTS.

The following are the main parts supplied in the kit:

- Main alarm unit. 
- Remote controls.
- Wireless back-up battery siren or wired siren, loudspeaker.
- Main unit universal wiring harness. 
- Siren wiring harness. 
- Siren bracket.
- Ultrasonic sensors.
- Installation accessories.
- LED / control button.
- Quick reference user manual.
- CD Instruction Manuals (if provided).
- Pin Code card. 

2. - INTRODUCTION.

The main unit of this system can be armed/disarmed by the remote control or with the Driver Card (optional).
This manual contains all information required to 

fi

 t the system on 12 V battery vehicles with the negative pole connected 

to the vehicle body.

HOW TO ACCESS TO THE VEHICLE SPECIFIC TECHNICAL DOCUMENTS.
 

Access to the web site www.cobra-es.com >

 Professional area 

and register yourself to be allowed to download the 

technical documentation.

HOW TO DEFINE THE INSTALLATION SOLUTION.

Access to the professional area of the web site www.cobra-es.com and download the vehicle information.

3. - SYSTEM’S CONFIGURATION.

Be sure to have connected all Data Linker components and to have power supplied the system.
Run the speci

fi

 c software.

As soon as, it automatically checks - if the computer is connected to internet - if the installed version is the most updated 
one and, if not, it proposes its update.

We recommend to download all times the last update.

Additional software installation and the speci

fi

 c software usage details are available on the manual inside the CD supplied 

in the Data Linker kit or in the Cobra ES site, professional area, Application manuals.

 


background image

INSTALLATION MANUAL  4693-4698

4

4. - HOW TO PREPARE THE PIN CODE CARD.

Remove the separate PIN Code label from the back of the system main unit and place onto the supplied PIN Code Card.

www

.cobra-at.com

PERSONAL

IDENTIFICATION

CODE

4C4415A2A

S/N  0003 050524

PIN

CODE

1122

PIN

CODE

1122

 


background image

INSTALLATION MANUAL  4693-4698

5

5. - INSTALLATION PROCEDURE.

System’s component positioning.

As much as the components of the system will be placed in secure and dif

fi

 cult to access positions as higher the protection 

level will be.

WARNING

: each element must be positioned so that it does not interfere with moving parts.

Alarm unit. 

It must be 

fi

 tted inside the vehicle far away from heating sources, paying attention to keep the main connector oriented down.

Siren.

It can be installed in the engine bay as inside the vehicle far away from heating sources paying attention to keep the 
main connector oriented down.

Ultrasonic volumetric sensor.

The ultrasonic transducers must be 

fi

 xed to the top of the A pillars pointed towards the rear window or to the top of the 

C pillars pointed towards the windscreen. Their orientation should be as much as possible parallel to the side windows.

Emergency LED/control button 

It must be 

fi

 tted on the dashboard with its LED in a in sight position. The pushbutton should be easily accessible by the 

driver.

Bonnet pushbutton.

The installation of the supplied pushbutton is required if the vehicle is not yet equipped with the original one. The speci

fi

 c 

vehicle installation sheet supplies this info.

Antennas.

The RF antennas positioning (for both the main unit and the siren) is crucial for a proper system’s performance. They must 
not be cut, wrapped, connected to any other cables or to the vehicle body and they must be kept separate from the main 
wiring harness and as far as possible from metallic parts.

 


background image

INSTALLATION MANUAL  4693-4698

6

Electrical connections.

WARNING:

 to prevent damage to the vehicle electrical system during installation, we recommend to 

disconnect the battery negative cable and to reconnect it only after installation is completed. If the battery 
is not disconnected, to avoid the possible generation of errors by the original central units of the vehicle, it 
is necessary to pay attention during the connections and the use of the installation tools.

 

Pay attention when joining two or more wires. Avoid to make “quick connections” that do not ensure a good quality.
Also make sure that the wires of the Cobra 469X are routed so that they follow the original wiring of the vehicle to which 
they should be joined with the raps.

The addition of fuse is required as speci

fi

 ed in the main connection diagram.

In order to avoid human exposure to radio frequency electromagnetic 

fi

 elds, the distance of the device 

respect to vehicle occupants must be greater than 0,25m

26 ways connector J pin-out

J-1 and J-2 Engine crank inhibition

to get the maximum security level to the system connect the two wires as shown in the 

electrical diagrams to prevent the engine starter running. During the cranking phase, measure the value of the current in the circuit that 
has been interrupt, to make sure that it does not exceed the technical speci

fi

 cations of the product. Install an additional relay if required.

J-3 Output

:

 

make the connection depending on the chosen functionality (see “FUNCTIONS PROGRAMMING TABLES” manual).

J-4 Power blinker output

:

 make the connection to the directon lights wires.

J-5 Power blinker output

:

 make the connection to the directon lights wires.

J-6 Analogic input

: to be connected to a vehicle device (ex. passenger compartment fan heater) to reduce the US sensitivity 

(step 7.12) or to be connected to a push-button for the driver recognition (step 7.22).

J-7 Negative input

: to connect to the wire of the bonnet original push button.

J-8 Cobra BUS

communication line for the connection of compatible Cobra sirens and sensors.

J-9 and J-10 Do not connect.

J-11 

(see central door locking diagrams).

J-12 

(see central door locking diagrams).

J-13 

(see central door locking diagrams).

J-14 12 V connection (+30)

: the positive supply must be connected to a vehicle positive connection point upstream of the 

fuse box. Fit a 15 A fuse as close as possible to the connection point.

J-15 GND connection

: the ground must be connected to a factory earth point or directly to the negative pole of the battery.

J-16 Negative output for modules

: active when the system is armed. To be used for the connection of compatible Cobra 

modules.

J-17 Horn/loudspeaker negative output

: to program in line with the connected device. See electric diagrams and 

functionalities programming tables. The output set automatically as per selected device, for horn choose also 

fi

 x or intermittent.

J-18 +15/54 connection

:

 to be connected to a ignition key ON positive signal. The positive signal must be feeded while starting 

the vehicle and when the engine is ON.

J-19 Negative perimetric input

:

 

to connect to the other doors wire, when the signal is separated from the one of the driver’s door.

 


background image

GRIGIO-NERO

 GREY-BLACK

GIALLO-NERO

 

YELLOW-BLACK

ROSA-NERO

 PINK-BLACK

J20

J26
J13

ARANCIO 

ORANGE

VIOLA

 

VIOLET

VIOLA-BIANCO

 VIOLET-WHITE

J24

ARANCIO

 

ORANGE

VIOLA

 

VIOLET

J9

J10

MARRONE

 

BROWN

J16

ARANCIO-BIANCO

 

ORANGE-WHITE

J11

J25
J12

GRIGIO

 GREY

J23

ARANCIO-NERO

 

ORANGE-BLACK

J19

BIANCO

 WHITE

J17

VERDE-ROSSO

 GREEN-RED

J18

ROSA-BIANCO

 PINK-WHITE

J6

VERDE 

GREEN

J1
J2

GIALLO-BLU

 

YELLOW-BLUE

J8

ARANCIO

 

ORANGE

VIOLA

 

VIOLET

VERDE 

GREEN

+ 15

max 20 A (1 s)

6 A cont.

Vedi schemi CDL

See CDL diagrams

1/2/3/4

Vedi manuale tabelle di

programmazione

See Programming Tables manual

Vedi schema "

G

"

See "

G

" diagram

INGRESSO SENSORI

SENSORS INPUT

Art. 469X

USCITA SIRENA / CLACSON

SIREN / CLACSON OUTPUT

COBRA BUS

STARTER +50

USCITA NEGATIVA ALLARME INSERITO

ARMED ALARM NEGATIVE INPUT

I FUSIBILI NEL DIAGRAMMA NON SONO FORNITI

THE FUSES ARE NOT SUPPLIED IN THE KIT

NERO

 

BLACK

ROSSO

 

RED

J-15
J-14

15 A

GND

BLINKER

OUTPUT

BLINKER

OUTPUT

POWER

POWER

GIALLO 

YELLOW

GIALLO-VERDE 

YELLOW-GREEN

GIALLO-BIANCO

 YELLOW-WHITE

J-5

7,5 A

J-4

7,5 A

J-3

BLU-ROSA 

BLUE-PINK

VIOLA-NERO

 VIOLET-BLACK

J-22

J-7

3 A

J

LED

Al fine di evitare l'esposizione umana ai campi elettromagnetici, la distanza del

dispositivo rispetto agli occupanti del veicolo deve essere maggiore di 0,25 m.

Non utilizzare

Do not use

POWER

BLINKER

In order to avoid human exposure to radio frequency electromagnetic fields, the

distance of the device respect to vehicle occupants must be greater than 0,25 m.

 


background image

COLLEGAMENTI SIRENA NO WIRELESS (5362)

NO WIRELESS SIREN CONNECTIONS (5362)

COLLEGAMENTI SIRENA WIRELESS (5365)

WIRELESS SIREN CONNECTIONS (5365)

PULSANTE COFANO

BONNET PUSH-BUTTON

PANNELLINO LED

LED PANEL

J-21

Vedi scheda

tecnica vettura

See the car fitting

instructions

J-8

Vedi scheda

tecnica vettura

See the car fitting

instructions

3 A +30

1

2

LED

Ø 

10 mm

1

2

1

2

3 A

ROSSO

 

RED

NERO

 

BLACK

+30

BLU 

BLUE

NERO 

BLACK

GIALLO-BLU 

YELLOW-BLUE

1

14 mm

Ø 

10 mm

Ø 

2 mm

2

Ø 

10 mm

J

G

Antenna

GIALLO-BLU

 YELLOW-BLUE

NERO

 

BLACK

ROSSO

 

RED

NERO

 

BLACK

BLU

 

BLUE

 


background image

1N4004

3 A

NERO

 BLACK

NERO

 BLACK

OK

PASS

TX

LED

RX

Filo BIANCO

 

WHITE wire

 J17

Filo BIANCO

 

WHITE wire

 J17

Filo BIANCO

 

WHITE wire

 J17

E

C

D

F

 

ROSSO

RED

(TX)

RX

TX

RX

TX

Antenna

Collegamenti sensori U.S.,

pannellino-LED e antenna.

U.S. sensors, LED panel

and antenna connections.

B

Installare ponticello (vedi catalogo) fra TX

ed RX Ultrasuoni, se non viene utilizzato il

sensore volumetrico

.

Install the jumper wire (see the catalogue)

between the U.S. TX and RX, if you don't use

the volumetric sensor.

A

-

-

BIANCO

WHITE

(RX)

Collegamento dell'avvisatore acustico del veicolo

con relè supplementare.

Vehicle horn connection with additional relay.

87

30 86 85

Impianto

originale

Original

system

Relè

supplementare

Additional

Relay

Relè originale comandato da un segnale negativo.

Collegamento dell'avvisatore acustico con segnali

di controllo negativo applicato al relè originale.

Original relay controlled by a negative signal.

Vehicle horn connection with negative control signal

to the original relay.

87

30 86 85

Y

PASS

TX

LED

RX

Y

1

2

3

U.S.

U.S.

+30

+

-

15 A

+30

- / +

- / +

 


background image

GIALLO-NERO

YELLOW-BLACK

GRIGIO-NERO

GREY-BLACK

NON UTILIZZATI (DA ISOLARE)

NOT USED (TO ISOLATE)

(-)

(-)

VIOLA

VIOLET

ARANCIO

ORANGE

ARANCIO-BIANCO

ORANGE-WHITE

VIOLA-BIANCO

VIOLET-WHITE

7,5 A

7,5 A

2

(+)

(+)

ARANCIO

ORANGE

VIOLA

VIOLET

ARANCIO-BIANCO

ORANGE-WHITE

VIOLA-BIANCO

VIOLET-WHITE

GIALLO-NERO

YELLOW-BLACK

GRIGIO-NERO

GREY-BLACK

NON UTILIZZATI (DA ISOLARE)

NOT USED (TO ISOLATE)

+

7,5 A

7,5 A

ARANCIO-BIANCO

ORANGE-WHITE

VIOLA-BIANCO

VIOLET-WHITE

GIALLO-NERO

YELLOW-BLACK

GRIGIO-NERO

GREY-BLACK

ARANCIO

ORANGE

VIOLA

VIOLET

MARRONE

BROWN

BLU

BLUE

MOTORE  ADDIZIONALE

ADDITIONAL  MOTOR

CHIUSURE CENTRALIZZATE

CENTRAL DOOR LOCKING

+

7,5 A

7,5 A

3

1

M

ARANCIO-BIANCO

ORANGE-WHITE

VIOLA-BIANCO

VIOLET-WHITE

ARANCIO

ORANGE

GRIGIO-NERO

GREY-BLACK

VIOLA

VIOLET

GIALLO-NERO

YELLOW-BLACK

MOTORE DELLA PORTA

(MONTATO IN ORIGINE)

DOOR MOTOR

(ALREADY EXISTING)

ALLA CENTRALE CHIUSURE

D'ORIGINE O AL PULSANTE

DI COMANDO

TO THE EXISTING CDL UNIT

OR TO THE CDL PUSH-BUTTON

+

7,5 A

7,5 A

4

AUTO CON CHIUSURE A COMANDO NEGATIVO

VEHICLES WITH NEGATIVE CDL PULSE

COMANDO DIRETTO MOTORE ORIGINALE PORTA

ORIGINAL DOOR MOTOR DIRECT CONTROL

AUTO CON CHIUSURE A COMANDO POSITIVO

VEHICLES WITH POSITIVO CDL PULSE

AUTO SPROVVISTE DI AZIONATORE PORTIERA LATO GUIDA

VEHICLES WITHOUT ACTUATOR IN THE DRIVER’S SIDE DOOR

 


background image

INSTALLATION MANUAL  4693-4698

15

J-20 Positive perimetric/odometer input

:

 

to be connected to the vehicle roof lamp only after the function has been activated 

(see the “FUNCTIONS PROGRAMMING TABLES manual”). The input is 7 s delayed after the system arming.

J-21 Negative input to enter in programming procedure/to connect bonnet pushbutton

: if connected to 

ground the system will enter in the programming procedure for all applications not able to detect the original bonnet pushbutton. If the 
siren is a wireless one this input must not be used for the bonnet pushbutton connections. For wired siren or loudspeaker this input 
must be used for the connection of the bonnet pushbutton as indicated in the speci

fi

 c vehicle PLIP installation sheet.

J-22 Negative perimetric input

:

 

to be connected to the vehicle roof lamp or to the driver’s door wire when the signal il 

separated from the one of the other doors. The input is 7 s delayed after the system arming.

J-23 Negative input for additional modules

:

 to be used as a triggering input for the connection of compatible Cobra modules.

J-24 

(see central door locking diagrams).

J-25 

(see central door locking diagrams).

J-26 

(see central door locking diagrams).

MAKE CONNECTIONS AS FOR ELECTRIC DIAGRAMS

 


background image

INSTALLATION MANUAL  4693-4698

16

6. - ACTIVE FUNCTIONALITIES.

6.1 - Interior protection with ultrasonic volumetric sensor.

The system protects the vehicle interior with a volumetric ultrasonic sensor. Any attempt to get into the vehicle will be 
detected and the alarm will trigger.

6.2 - Perimetric protection with door open warning diagnostic.

The alarm will trigger by opening any door, boot and bonnet. Should you have left any door opened while arming, the system 
will signal it by 3 

fl

 ashes of the direction lights and 3 audible signals (5 audible signals if the arming/disarming audible 

signals function has been activated).

6.3 - Cable cutting protection 

(only for systems with back-up battery siren).

The alarm will trigger if the system is not power supplied (cutting of cables - battery disconnection) signalling the sabotage. 

6.4 - Engine crank inhibition.

As soon as the system is armed the engine cranking is not possible anymore. 

 
6.5 - Arming the system with the volumetric ultrasonic protection disabled.

This function allows to arm the system leaving temporarily disconnected the interior volumetric protection. The protection 
must be disabled any time you leave somebody or an animal in the vehicle. If you want to leave any window opened also 
disable the protection to avoid false alarms. All other protections remain active. 

To disable the volumetric protection proceed as follow:
Arm the system pressing the “A” pushbutton of the remote control, pressing another time the “A” pushbutton the volumetric 
protection (Ultrasonic sensors) is deactivated, the deactivation is con

fi

 rmed by one 

fl

 ashing of the direction indicators and 

one beep.
Pressing another time the “A” pushbutton the volumetric protection is re-activated and the external sensors are deactivated, 
the deactivation is con

fi

 rmed by two 

fl

 ashing of the direction indicators and two beeps.

Pressing another time the “A” pushbutton, the volumetric protection and the external sensors are deactivated, the deactivation 
is con

fi

 rmed by three 

fl

 ashing of the direction indicators and three beeps, or

switch the engine off being sure that the ignition switch has been turned to the OFF position. Within 5 s press the emergency 
panel pushbutton and keep it pressed until it will 

fl

 ash once to con

fi

 rm only the volumetric protection has been disabled. 

By keeping the pushbutton pressed the system will con

fi

 rm with two 

fl

 ashes that only the additional sensor input has been 

disabled, with three 

fl

 ashes for both of them disabled. The selected protection will remain disabled until the system will be 

disarmed. It will be automatically restored at the next arming.

6.6 - Emergency panel LED.

The LED main scope is to show the system arming and disarming conditions. When the system is armed the LED gets 
ON and remains illuminated until the 25 s arming period has elapsed. After that it starts blinking. It goes OFF as soon as 
the system is disarmed.

 


background image

INSTALLATION MANUAL  4693-4698

17

6.7 - Alarms memory.

If the system has gone off (alarm on) during the arming time it will warn you with 3 

fl

 ashes of the direction lights and 3 audible 

signals (5 audible signals if the arming/disarming audible signals function has been activated). It also stores in its memory 
the reason of the occurred alarm and shows it on the emergency panel LED. Count the number of 

fl

 ashes and check the 

corresponding alarm reason on the table. By turning the key ON the memory will be deleted.

LED NUMBER OF 

FLASHES

ALARM ROOT 

CAUSE

fl

 ash

Door opening detection.

fl

 ashes

Ultrasonic volumetric detection.

fl

 ashes

Bonnet opening detection.

fl

 ashes

Ignition key ON detection.

fl

 ashes

Boot opening detection.

fl

 ashes

Door opening detection.

fl

 ashes

Additional sensors.

fl

 ashes

Siren cable cutting - Cobra Bus.

fl

 ashes

Not used.

10 

fl

 ashes

Not used.

11 

fl

 ashes

Immobilizer 1 module connected to the Cobra Bus.

12 

fl

 ashes

Immobilizer 2 module connected to the Cobra Bus.

13 

fl

 ashes

Not used.

14 

fl

 ashes

Not used.

6.8 - Emergency disarming.

If the remote control get lost or if it doesn’t work, open the door with the mechanical key and disam the system following 
the emergency procedure described in the user manual.

6.9 - Alarm condition. 

When the system goes off (alarm ON) the siren sounds and the direction lights 

fl

 ash for 28 s.

 


background image

INSTALLATION MANUAL  4693-4698

18

7. - PROGRAMMABLE FUNCTIONS.

(see the “FUNCTIONS PROGRAMMING TABLES” manual).

8 - NEW REMOTE CONTROLS AND / OR DRIVER CARDS (optionals) SELF LEARNING PROCEDURE.

(see ‘PAGE 2’ of the “FUNCTIONS PROGRAMMING TABLES” manual).

9. - FUNCTIONAL TEST.

During the 

fi

 rst 25 s after the system has been armed all protection functionalities can be tested without triggering an alarm.

Make the following tests during the 28 s inhibition time with the system armed:

open then close one by one all doors and boot 

- Check if the system is con

fi

 rming with three audible signal, each door 

opening detection.

Check the proper functionality of the volumetric ultrasonic sensor 

- Make movements, their detection will be con

fi

 rmed 

by a LED 

fl

 ashing.

Open the bonnet then lock the vehicle with the remote control

 - After 28 s from arming the system will indicate the 

bonnet opening with 3 audible signals.

Try to start the engine 

- If the engine cranking wires have been connected the engine will not start.

Check if the PIN emergency Code works properly

 - By correctly entering the PIN code the system disarms.

 

10. - 

SELF LEARNING PROCEDURE REQUIRED TO REPLACE THE MAIN UNIT OR THE WIRELESS 
SIREN REPLACEMENT.

The siren supplied in the kit is delivered already programmed to the main unit. Should you have the need to replace the 
siren or the main unit it is required to perform the self learning procedure as follows:

IMPORTANT

: don’t perform the procedure on two different vehicles parked closed each other. Their sirens could be 

memorized in one main unit only.

A.  Power the main unit by connecting the 26 ways connector.
B.  Connect the main unit blue wire to GND (only when a wireless siren is 

fi

 tted).

C.  Open the bonnet. 
D.  Connect the siren blue wire to GND (if not already grounded through the additional bonnet

 

pushbutton).

E.  Disconnect the siren 6 ways connector, then plug it again.
F.  Within 60 s turn the ignition key ON, an audible signal con

fi

 rms that the siren has been stored in the system.

G.  Turn the ignition key OFF and disconnect the BLU wires of the main unit and of the siren from GND (if grounded through 

the additional pushbutton simply open the bonnet).

Check the system functionality arming the system and triggering the alarm to check the proper sounding of the siren.

 


background image

INSTALLATION MANUAL  4693-4698

19

11. - DOCUMENTS HANDOVER.

Be sure the user user ‘quick reference’ and the PIN code card is placed in the glove compartment and carry out a full 
functionality demonstration to the customer.

12. - SYSTEM TECHNICAL SPECIFICATIONS.

The manufacturer shall not be liable for any faults or malfunctions in the anti-theft device and/or in the electrical system of 
the vehicle due to incorrect installation and/or to failure to comply with the indicated technical speci

fi

 cations. The system 

must only be considered as a deterrent agaist theft attempts.

TECHNICAL SPECIFICATIONS

Rated supply voltage

+12 V DC

Operating voltage

+8 V ÷ +16 V DC

Current consumption (central unit, LED and siren) disarmed

8 mA

Current consumption (central unit, LED and siren) armed

12 mA

Central unit operating temperature

- 40 °C + 85 °C 

Siren operating temperature

- 40 °C + 85 °C

Self power supply

 Lithium Battery 6 V 1300 mAh

Loudspeaker sound pressure level

 >115 dB @ 1m

Siren sound pressure level

>114 dB @ 1m

- Central dimensions

91x69x35 mm

- Siren dimensions

113x79x45 mm

Trasmitter battery / Cobra Driver Card

 Lithium Battery 3 V CR2032

13. - FOR 

UK

 MARKET ONLY

Category 1,2 or 2-1 systems permanently installed as aftermarket equipment by import or distribution centres, vehicle 
dealers, or by Independent Installers, shall be installed by companies and technicians who are trained, quali

fi

 ed, industry 

recognised professional installers. 
Thatcham recommends to its insurer members that the installations of certi

fi

 ed products within the aftermarket are registered 

with an independent installation registration system which can be accessed by insurance companies. Thatcham administer 
the Thatcham Recognised Installer scheme, on behalf of the British motor insurance industry, providing independent 
registration of installations to vehicle owners. Details of the Thatcham Recognised Installer scheme can be found at www.
thatcham.org/tri/home. To ensure consumers insurance cover is not adversely effected it is highly recommended that all 
installations are carried out by Thatcham recognised installers and that all installs are registered providing the vehicle 
owner with a Thatcham recognition of installation for presentation to insurers.

 


background image

Cobra Automotive Technologies

via Astico 41 - 21100 VARESE - ITALY

www.cobra-at.com

06DE3796A - 03/13