Cobalt Digital Inc +EAS Manual Supplement

BBC 1000

Made by: Cobalt Digital Inc
Type: Manual Supplement
Category: Security System
Pages: 18
Size: 1.27 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

2506 Galen Drive
Champaign, IL 61821
Voice 217.344.1243 • Fax 217.344.1245
www.cobaltdigital.com

OPT-SW-PHXEAS-MS (V1.1)

Cobalt Digital Inc.

Emergency Alert System Text 

Crawl Generation Option (+EAS)

Manual Supplement


background image

Copyright

©Copyright 2016, Cobalt Digital Inc. All Rights Reserved.
Duplication or distribution of this manual and any information contained within is strictly prohibited without the express written 
permission of Cobalt Digital Inc. This manual and any information contained within, may not be reproduced, distributed, or 
transmitted in any form, or by any means, for any purpose, without the express written permission of Cobalt Digital Inc. 
Reproduction or reverse engineering of software used in this device is prohibited.

Disclaimer

The information in this document has been carefully examined and is believed to be entirely reliable. However, no responsibility 
is assumed for inaccuracies. Furthermore, Cobalt Digital Inc. reserves the right to make changes to any products herein to improve 
readability, function, or design. Cobalt Digital Inc. does not assume any liability arising out of the application or use of any 
product or circuit described herein. This manual is a supplement and is incomplete unless used with an Owner’s or Product 
Manual. Refer to the applicable Product Manual for complete personnel protection and equipment safety information.

Trademark Information

Cobalt

®

 is a registered trademark of Cobalt Digital Inc.

openGear

®

 is a registered trademark of Ross Video Limited. DashBoard™ is a trademark of Ross Video Limited. Other product 

names or trademarks appearing in this manual are the property of their respective owners.

OPT-SW-PHXEAS-MS (V1.1)

Manual No.:

OPT-SW-PHXEAS-MS

Document
Version:

1.1

Release Date:

August 23, 2016


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT 

1

Chapter 1

Overview

This manual supplement provides descriptions and operating instruction for 
the 

+EAS

 Option available as an option on various new Cobalt

®

 cards and 

BBG-1000 standalone units, and as a purchased field-installed licensable 
feature upload for the same models. Compatibility of this option for various 
card and device models is indicated on the web page for the card or device.

+EAS Option Functional Description

(See Figure 1.) Option 

+EAS

 provides for automated keying Emergency Alert 

System (EAS) text crawls in the active program video output. The function 
receives its text stream via a card serial data input. The EAS crawl start can be 
set to trigger upon receiving the serial data message, or be set to use a GPI to 
trigger start of the EAS crawl. 

Embedded in the received serial data are commands which set the message 
severity to be shown by the keyed crawl (severity is correlated to 
user-specified text color and background color for the crawl). User controls 
allow control of the crawl speed and repeat of the crawl burn-in (if desired).

Figure 1  EAS Simplified Functional Diagram

Read and understand the content of this supplement and all setup procedures 
herein before implementing the Emergency Alert System (EAS) functions 
described herein for practical use. Proper and expected EAS crawl insertion 
must be manually observed and verified upon setup and subsequently during a 
regularly scheduled EAS test (and optimally upon any actual emergency 
communications). More information regarding EAS requirements and practices 
are specified and promulgated in USC CFR 47 Part 11.

Frame Sync
EAS Raster/

Character 

Inserter

Program Video

Launch
Control

GPI/Event/Manual

Start Trigger

(start sutomatically or

upon GPI or event trigger)

Program Video w/ EAS 

Text 

Interpreter

Serial Rx


background image

2

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

+EAS Interconnect 

Option 

+EAS

 is intended for use with external EAS alert systems which 

provide both a logic GPI trigger (optionally) as well as a serial data output in 
which coding is present that indicates severity level, as well as providing the 
user-facing text string that is used for the alert burn-in.

Figure 2 shows typical interconnection between the external EAS alert system 
and the card/device hosting the 

+EAS

 option.

For systems where an openGear

®

 card is hosting the 

+EAS

 option, a rear 

module with both GPI and serial (COMM) interfaces must be installed in 
order to use the 

+EAS

 option. Consult “Rear Modules” in card Product 

Manual or the card’s web page for rear module assortment and descriptions 
available for the card. 

Figure 2  Typical Interconnections For EAS GPI / COMM Rx

SDI IN From

Master Control

For openGear

®

 (card-based) installation, card slot must be fitted with a rear 

module that offers both serial (COMM) and GPI interfaces. In this example, these 
interfaces are broken out via shared RJ-45 connector GPIO / COMM.

For BBG-1000 desktop/standalone installation, these models use a shared RJ-45 
jack providing the serial (COMM) and GPI interfaces.

Pin

Function

1

GPI IN 1

2

GPI IN 2

7

UART_RX

8

GND

Note: View is “looking into” connector 

from unterminated (user-facing) 
side.

SDI OUT
w/ EAS

Serial / GPI
(see details
to left)

1 2

RS-232

Rx

GPI

G

2

1

G

Rx

7 8


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT

3

Uploading Option Feature (Field Upgrade Only)

Note:

• If your card/device was purchased with the option(s) covered here, this 

procedure is not required for your card/device. If you have purchased this 
feature to be field-installed on an existing card/device, perform the upload 
procedure here to upload the feature key file sent by Cobalt, and to activate 
the feature on your card. 

• To order features and obtain a license key, contact Cobalt

®

 sales at 

sales@cobaltdigital.com or at the contact information on the cover of this 
supplement. Please provide the Serial Number of your card (displayed in the 
Card Info pane) when contacting us for your feature key. A key is tied to the 
card’s serial number and will only work with that card. Please indicate if 
upgrades are needed for more than one card.

Activate licensable feature as described below.

1.

Cobalt typically supplies a .bin file (by e-mail; file size < 10kB) that 
activates the licensable feature. Download this file to a convenient 
location on a computer connected to the card’s frame (or BBG 
standalone network).

Note:

During this procedure, the card will go offline while the feature is installed. 
Make certain card is not carrying OTA signal.

2.

In DashBoard for the card being upgraded click the 

Upload

 button and 

browse to the feature license file (in the example below, 
license_SN371604_9922-FS_EAS.bin).


background image

4

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

3.

Select the file, click 

Open

 and then follow the prompts. With intended 

card selected (“Slot 6 9922-FS” in example above), click 

Finish

 and wait 

for completion and click 

Close

. When the card comes back online, the 

feature appears in the DashBoard controls and is ready for use.

Note:

• Applying the licensable feature has no effect on prior settings. All control 

settings and drop-down selections are retained.

• Added features, when first appearing after installation, are set to their factory 

default states. For features having a direct impact on the output signal, all 
controls are initially set to disabled or null.

Serial Text Formatting for Option +EAS

Figure 3 shows the typical serial coding used in a Sage™ ENDEC message 
sent by the device to be received as encoded text by a receiver such as 

+EAS

Present in typical EAS serial data received by option 

+EAS 

is a reserved 

severity character at the start of the string (see below). This character sets the 
crawl graphic attributes to the attributes user-selected using the 

EAS > Crawl

 

sub-tab attribute controls for the three severity levels.

Note:

If the received message does not contain the severity marking character, 
Severity 1 will be assumed and attributes assigned to Severity 1 (per the

EAS > Crawl

 sub-tab settings) will be used.

Figure 3  Typical EAS Text Message Coding

<STX><sev><text...text...text........................><ETX>

Severity byte
0x31 (Severity 1; most severe)
0x32 (Severity 2; less severe)
0x33 (Severity 3; lowest - informational)

Start byte
0x02

Message content text
standard ASCII coded text and punctuation

Stop byte
0x03


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT

5

+EAS Controls and Examples

Table 1 individually lists and describes the EAS controls available using 
DashBoard™ for cards/devices equipped with the 

+EAS

 option. 

Table 1

+EAS Option Control List and Descriptions

Provides master controls that direct the playout of all EAS 
insertions, including triggering mode, as well as and crawl speed 
and looping. Also provides an event log.

EAS > General Setup

•  EAS State (Status)

Displays status of crawl activity. When crawl is not currently being inserted, 

shows “Crawl Stopped”.

•  EAS Triggering Mode Select

Selects how EAS is played out when a trigger is received as follows:

• Disabled -  EAS is never played out regardless of received triggering. In the 

Event Setup table, no EAS-related events will be generated or triggered 
upon.

• Event Triggered -  EAS text string will be received and buffered, but will be 

played out (inserted into key) only when an accompanying trigger is 
received.

This is useful in cases where some time is required to acquire the entire text 
string before playout can be executed. For external systems where this is a 
concern, a GPI signal is typically provided as a “ready-go” signal to activate 
the crawl. (See Event Setup Controls, p. 10 for an example of GPI triggering 
setup.)

• Immediate -  EAS text string will start playout as soon as the complete 

message text is received.

Note: The Crawl Start Delay control described below can be used to buffer 

the playout start for systems where the separate GPI trigger 
described above is not available, but delay may still be desired. 

•  Crawl Start Delay and Loop Control

• Crawl Start Delay sets the delay (in seconds) from when text is first 

received to when the playout insertion is executed.

• Crawl Loop Count sets the number of times (from 1 to 3) the active crawl 

insertion will be repeated for a given message. 

Note: For a given EAS message/event, an automated or external stop 

control is not necessary to stop the crawl. Crawl key insertion and 
scroll will stop and normal video will resume when the Crawl Loop 
Count
 is exhausted.

EAS MSG

Received

GPI/User Event 

Start Trigger

Crawl

Start

Crawl

End

Optional added delay

(using Crawl Start 

Delay control)

Optional detect crawl end 

user event (to trigger 

post-crawl setup)

EAS MSG

Received

Crawl

Start

Crawl

End

Optional added delay

(using Crawl Start 

Delay control)

Optional detect crawl end 

user event (to trigger 

post-crawl setup)


background image

6

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

(continued)

• Activity Log Display

Displays a log of the four most recent EAS insertion actions. 

Provides controls for setting the serial comms details for the 
interface between the external EAS system and the +EAS card/
device. Also shows the message text and severity level for a 
queued message.

EAS > Interface

•  Message Displays

Displays queued text string as well as associated severity status. Clear 

allows status display and the corresponding message to be cleared. If a 
crawl is currently in progress, clicking Clear Queued Message(s) will stop 
the crawl immediately.

•  COMM (Serial) Setup Controls

For EAS Rx, sets COMM receive for port, bit rate and parity as shown.

Note: Where rear module exposes only one COMM port, set control here to 

use COM 1

Table 1

+EAS Option Control List and Descriptions   continued

In the example here, log shows a 
complete cycle for one message event, 
consisting of a crawl start and crawl stop.


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT

7

Provides controls for setting the crawl speed, positioning within 
the active raster, as well as character and background size/
appearance attributes.

EAS > Crawl

•  Crawl Text Attributes

Allows setting crawl text speed, burn-in position, and character size as 
follows:

• Crawl Overlay -  Provides master enable/disable for crawl key/text burn-in.

• Crawl Speed -  Sets the relative speed at which the text scrolls from right to 

left across the burn-in background key. (Setting “1” is slowest and “6” is 
fastest.)

• Vertical Position -  Sets the vertical position of the full-width burn-in 

background key and text (text is always centered vertically within the 
background banner key). (Setting “0” positions the burn-in at top of image.)

For SD usage, burn-ins positioned near the top of the active 

image will impinge on and corrupt line 21 closed-captioning 
waveform. Make certain burn-in is not positioned in this area. 
(Position control set greater than 1.0 avoids this issue.)

If position is set too much in the bottom direction (greater control 
settings) in some cases the burn will not appear in the active 
raster.

• Character Size (HD, SD) -  SD controls selects from Small or Large 

choices for SD program video. HD control selects from 16 px to 234 px 
choices for HD program video.

•  Text/Background Color Select

Allows setting the text and background colors from various choices for each 

of three Severity levels. (See examples in this section.)

Note: Color selection is subjective and not necessarily dictated by any 

requirements. However, it is recommended that red be used for 
Severity 1 level. 

Table 1

+EAS Option Control List and Descriptions    continued


background image

8

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

(continued)

•  Text Opacity Control (HD Only)

For HD programming, allows setting the opacity of text and background. (See 

examples in this section.)

Note: Typically, it is recommended to have Character Opacity (text) set at 

the maximum setting for optimal readability in most cases. 

Table 1

+EAS Option Control List and Descriptions    continued

Crawl insertion spans the entire raster 
width in all cases, with text scolling from 
right to left.

In the example here, Vertical Postion is 
set to 80 (appr. 80% down from top).

In the example here, Background Opacity 
is set to 50%.


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT

9

Allows manual actuation of EAS test insertion. This is useful to 
test and assess visual impact and aesthetics of burn-in for all 
three Severity levels. Actuation here does not require any 
external EAS assets or interconnection.

EAS > Manual EAS Entry

Table 1

+EAS Option Control List and Descriptions    continued

Entry area/pad for manual message 
insertions text

Pressing Confirm and confirming with 
prompt immediately starts the burn-in 
insertion on the output raster

Selection sets the type of message to 
be inserted in manual test

Note: • The manual EAS entry function described here can be used in an 

emergency if automated assets are not present or functional.

• If EAS Mode (insertion mode) is set for Event Triggered (as described 

in EAS > General Setup, p. 5), Generate Manual EAS Message using 
controls here won’t work (the message insertion will be “waiting for” a 
GPI or other configured trigger). To insert or test using manual 
generate, make certain EAS Mode is set to Immediate.


background image

10

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

Where +EAS is licensed for a card/device, the Event Setup > 
Event Triggers
 sub-tab has added choices associated with EAS 
actions. 

An added EAS trigger column exposes EAS actions that can be 
used as triggers to activate other actions. These triggers and 
actions can be used with other card/device attributes to step into 
and out of EAS modes and normal operation (as shown in the 
example below). The Event Action column also has choices that 
allow actions upon other triggers (such as GPI) to start and stop 
EAS (also shown in an example below).

Event Setup Controls

Table 1

+EAS Option Control List and Descriptions    continued

In the example here for Event 3 and Event 4, when a Crawl Start or Crawl Stop event has been detected, these events can 
serve as triggers to respectively invoke user preset “Go to EAS Audio Route” or “Go to Norm1A Audio Route”. These presets 
would be user-defined presets that perform special audio routing when a crawl is active, and resume to normal after the crawl 
has stopped.

Note: • Refer to Product Manual for detailed descriptions of the Event Setup tab and its sub-tabs, which contains 

important information regarding the use of event presets and actions.

In the example here for Event 1 and Event 2, GPI 1 is being used to start (and optionally) stop the crawl when 

EAS > General 

Setup

 is set to use Event Triggered operation. Note that while the Event 2 EAS Stop Trigger is not necessary to stop the crawl, 

the defined event here is useful should the need arise to abort the crawl sooner than its full content playout (as in the case of an 
erroneous “false alarm”). (A GPI correlated to an EAS Stop Trigger can be used to immediately stop a crawl even if all the crawl 
text has not yet been displayed.) Also note that EAS crawl for a given message ceases after the Crawl Loop Count is exhausted. 

Note: Although EAS Start Trigger starts an EAS text crawl, if no EAS message has been received, no text crawl will be generated.


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT

11

Provides logo insertion (such as station ID “bug”) to be inserted 
into output raster. Logo insertion can be correlated to triggers 
such as GPI in conjunction with the Event Setup controls.

Logo Insertion Controls

Note: This feature, while part of the +EAS licensed option, is entirely independent of +EAS setup and functions. While logo 

insertion can be correlated with EAS functions (using the Event Setup controls), the primary use case for logo insertion is 
hourly station ID insertions (as triggered by a GPI separate from EAS control functions).

•  Logo Overlay Test Control

• Graphic Overlay (Disable/Enable) allows the selected graphic to be 

manually test inserted to assess aesthetics and positioning.

• Graphic Overlay Status shows if a graphic file associated with the 

DashBoard graphic name (“Logo” in this case) is loaded and ready for use.

Note: Make certain control is set to Disabled after assessing manual 

insertion. The graphic can then be inserted using automation as 
described further in this section.

Table 1

+EAS Option Control List and Descriptions    continued

Uploading Your Logo Image to Cobalt Card or BBG-1000 Device

A user memory area for images is reserved in the card/device. A standard .png file is converted to a .bin file which is uploaded 
to the card/device, where the .bin then provides the logo graphic used by the card/device. The conversion consists of an online 
tool that takes in a .png and outputs the image .bin file which is then uploaded to the card/device as described in the steps below.

Note: • Your file must be a .png file with a .png extension.

• No scaling is applied or available using the generator tool. (For example, if a 100 x 100 pixel image is uploaded to the 

tool, the image overlay will also be 100 x 100 pixel regardless of program video format or raster dimensions.

• Transparency aspects in your native file are preserved in the generator conversion.

Use the conversion tool as described below.

1. With your .png sized as desired for insertion, go to http://a-cdi-eng/com:55080/cgi-bin/image_upload.py.

2. Using Graphic Upload Number drop-down on Logo Insertion tab, select the DashBoard graphic ID where you want the 

image to be available (for logo insertion, choose the Logo item). 

3. Browse to your file. A prompt will appear to save the generated .bin file. Select Save (or Save As) to store the generated file in 

your desired folder. Close the tool when done.

4. In DashBoard on the card/device page, click Upload to upload the image file to the card/device. Follow the prompts to browse 

to and upload the file.

5. The image is now ready to be used by the card/device. 

This drop-down selects under which DashBoard name (Logo 
thru Trouble Slate 3) the uploaded graphic will be associated 
with. (For Logo Insertion here as described here, use Logo 
choice. Depending on card/device options loaded, choices 
other than Logo may not appear.)


background image

12

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

(continued)

• Logo Positioning Controls

Sets logo burn-in position as follows:

• Horizontal Position sets horizontal position (in percentage of offset from 

left of image area, left justified). (Range is 0 thru 100)

• Vertical Position sets vertical position (in percentage of offset from top of 

image area, top justified). (Range is 0 thru 100)

Table 1

+EAS Option Control List and Descriptions    continued

Positioning with H and V controls at 
zero (origin)

Positioning with H and V controls 
both at 50

Origin (0,0)

x= 100%

y= 100%

Station ID Logo Insertion Setup Example

A card/device GPI is ideally suited as the trigger to enable and disable station ID “bug” insertion. The example below shows the 
setup using the Logo Insertion tab along with Event Setup tab to use a GPI to perform this function.

In this example, GPI 2 is set to use its falling-edge and rising-edge to correspondingly enable and disable Logo using the GPI 
and Event Action columns. (All other columns are set to Don’t Care for the function in this example.)


background image

OPT-SW-PHXEAS-MS (V1.1)

EAS OPTION (+EAS) MANUAL SUPPLEMENT

13

Integration with Cobalt Option +TTS

Option 

+EAS

 can be co-installed on Cobalt cards and BBG-1000 standalones 

that are also licensed with Text-to-Speech Option 

+TTS

. The same GPI (or 

other control signals or conditions) used for EAS triggering can also be used 
(to a large extent) for TTS triggering if desired. On any model where 

+EAS 

is 

available, 

+TTS 

is also available.

If using 

+EAS

 in conjunction with 

+TTS

, care should be taken to 

make certain the text fed to 

+TTS

 and 

+EAS

 is identical.

Troubleshooting

This section provides troubleshooting information specific to the 

+EAS

 

function (for general troubleshooting information, please refer to the Product 
Manual for the card or device). If any error indication (as described in this 
section) occurs, use this section to correct the condition. 

Table 2

Troubleshooting Processing Errors by Symptom

Symptom

Error/Condition

Corrective Action

Manual EAS insertion 
does not work

EAS Start bound to other 
action (such as GPI)

For manual insertion mode (EAS > Manual EAS Entry > 
Generate Manual EAS Message), EAS Mode must be set to 
Immediate. (See EAS > General Setup, p. 5.) If EAS 
insertion requires an event to trigger, EAS won’t play out 
unless the specified event occurs.

Automated EAS insertion 
does not work

• EAS insertion not enable 

in DashBoard

• Default EAS controls set EAS insertion to disabled. EAS 

must be set to mode other than Disabled in two places:
- In General Setup subtab, make certain EAS Mode is set

to desired mode other than Disabled (see
EAS > General Setup, p. 5).

- In Crawl subtab, make certain Crawl Overlay is set to

Enabled (see EAS > Crawl, p. 7).

• Message not received

• All messages propagated via the COM connection should 

show up in the Queued EAS Message Text status field in 
the EAS > Interface subtab. If expected message is not 
present, this means message was not received. Check 
COM settings, connections, and upstream alert device(s).

Note: A Manual Entry test is useful for distinguishing COM 

setup/data errors from other setup errors. Perform 
manual test first whenever COM error is suspected (see 
EAS > Manual EAS Entry, p. 9.)


background image

14

EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

Entire message (from start 
to end) not displayed, or 
message is truncated

Message start or stop 
occurs before message is 
ready or ended

An EAS Event Triggered mode should be used where serial 
data make take a relatively long time to accumulate in the 
card/device hosting EAS. GPI triggering can be used to then 
launch to insertion.

Also available is using the Crawl Start Delay control to hold off 
on immediate message playout. See EAS > General Setup
p. 5
. for more information.

Log indicates insertion 
performed, but insertion is 
not visible in output raster

Insertion positioned too low 
in raster for format being 
carried

On the EAS > Interface subtab, if the Vertical Position control 
is set too close to maximum (100.0), the crawl may not be 
visible in the active image area. SeEAS > Crawl, p. 7 fo
more information.

Closed captioning on SD 
output raster shows errors 
or visible corruption during 
EAS insertion

Insertion vertical position 
impinging on line 21 closed 
captioning space

For SD usage, burn-ins positioned near the top of the active 
image will impinge on and corrupt line 21 closed-captioning 
waveform. Make certain burn-in is not positioned in this area. 
(Position control set greater than 1.0 avoids this issue.)

Table 2

Troubleshooting Processing Errors by Symptom    continued

Symptom

Error/Condition

Corrective Action


background image

background image

Cobalt Digital Inc.

2506 Galen Drive
Champaign, IL 61821
Voice 217.344.1243 • Fax 217.344.1245
www.cobaltdigital.com