PDF User Manual

  1. Home
  2. Manuals
  3. Coalesse Train series Installation Instructions Manual

Coalesse Train series Installation Instructions Manual

Made by: Coalesse
Type: Installation Instructions
Category: Indoor Furnishing
Pages: 8
Size: 6.03 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Assembly and Modular Table Power System Installation Instructions

for Train

®

 Tables

If you have a problem, question, or request, call
your local dealer, or Coalesse at 1.800.627.6770
Or visit our website: www.coalesse.com

©

 

2015 Coalesse 

San Francisco, California U.S.A. 
Printed in U.S.A.

Page 1 of 8

939505524 Rev D

Rectangular Tables

90  Corner Top

Modesty Panel

Note: Refer to assembly direction 

# 939600192 for assembly of 

base power infeed.

Table of Contents

Topic

Page

Attach Stretcher to Legs

Attach Base To Table Top

Attach Modesty Panel to Assembly

Modular Table Power System Installation
General Safety Warnings
Ganging Hardware
Electrical Circuits

Modular Table Power Assemblies

Installing Modular Cable for 
End-to-End Applications

Cable Routing Restrictions

  

2

  3

  4

  5
  5
  5
  5

  6

  7

  8

 


background image

Page 2 of 8

939505524 Rev D

SHIPPED COMPONENTS:

(1) Table top
(2) Legs
(1) Stretcher

HARDWARE:
Stretcher Hardware:

(4) #730574 Allen Head Screws, 3/8-16 x 1”
(2) #811679 Stretcher Joint Backer Plate
(4) #732353 Lock Washers

Table Top Mounting Hardware:

(8) #A730461 Flathead Phillips wood
screws, #10x7/8”, black

TOOLS REQUIRED:

Electric Drill with 6” extension and:

• #2 Phillips bit
• T-27 Torx bit
• 7/32” Allen wrench bit

(NOTE: Hand tools may be substituted for 
the electric drill bits if necessary)
 

WARNING:

 Protect top surface from 

scratches while attaching base feet.

BACKER PLATE

LOCK WASHERS

ALLEN HEAD SCREWS

Attach Stretcher To Legs

1. 

Unwrap the stretcher from package.

2. 

Attach the stretcher to each leg

casting.

The Backer Plate (#811679) is 

installed on the outside of the 

casting as shown.

The stretcher is attached to each 

leg casting with (2) Allen Head screws

(#730574) and two lock washers.

STRETCHER

 


background image

TIP: Place a shim under carpet 

to allow a finger hold when 

assembled unit is ready to upright.

Page 3 of 8

939505524 Rev D

Attach Base To Table Top

1. 

Carefully place table top upside

down onto carpet or other soft, clean 
surface.  Lower base assembly into
place onto the table top. 

The leg

attachment brackets should fit

into the pockets routed into the

underside of the table top.

2. 

Attach the leg attachment

brackets to the table top using
(3) #A730461 screws in each
bracket. 

The 4th hole in the leg

attachment brackets will be

covered by the leg castings while

the table is upside down.

3. 

Carefully set the table right side

up, then drop top into vertical position.
This will give access to  install the 
4th screw in each bracket.

ROUT

1

1

Install (3) screws

through each

bracket at this time.

2

To drop table top into vertical position:

A) disengage plastic sliders (both sides)

B) rotate each swing arm toward the base

C) rotate top into vertical position

3

SWING ARM

 


background image

Page 4 of 8

939505524 Rev D

Attach Modesty Panel To Assembly

Note: To attach the modesty panel,

Train table top must be flipped up.

1. 

2. 

3.

4.  

Attach bracket,

facing outward,

to inside of leg.

Brackets are identified with “L”
or “R”. Attach the left-hand
bracket, “L”, LOOSELY to the
leg on the user’s left with (2)
torx head screws. Attach the
right-hand bracket, “R”,
LOOSELY to the leg on the
user’s right with (2) torx head screws.

 

DO NOT OPEN THE MODESTY PANEL DOOR FOR 24 HOURS. 

For full cure the door should not be opened for 24 hours.

Align top of brackets with top of modesty panel.
Also, adjust brackets on each side for the latchlock 
tape surface to fully contact the modesty panel.

Attach modesty panel to table by slipping 
the clips over the stretcher.

With upper modesty panel door open, peel off the
protective backing of the latchlock tape to expose 
the adhesive.  Close the modesty panel door and 
firmly press the door, adhering the latchlock tape 
on each bracket to the door.

SHIPPED COMPONENTS

(1) modesty panel
(1) hardware package

HARDWARE PACKAGE

(4) (73053705) torx head screws, 1/4-20 x 1/2” 
(1) (811772R) right-hand bracket, R 
(1) (811772L) left-hand bracket, L 
(1) latchlock tape on each bracket

TOOLS REQUIRED

(1) electric drill or rachet with T-27 torx bit

R

LATCHLOCK
TAPE

1

BRACKET

MODESTY PANEL

RH
BRACKET

LH
BRACKET

FLIPPED
TOP

STRETCHER

CLIPS

 


background image

Page 5 of 8

939505524 Rev D

12"

 MAX.

Circuit 1

Circuit 2

Green or no coating, 12 GA

Neutral

Ground

Hot 2

Hot 1

White, 12 GA

Red, 12 GA

Black, 12 GA

Electrical components 

MUST

 be 

accompanied by ganging hardware.

Table-to-Table:

 Tables must be

held together with table connection
hardware, shown in illustration at right,

NOT

 by electrical components.

SPIKE

SLOT

A coupling device is built into 

every Train Table to enable tables 

to gang together end-to-end

without tools or separate parts.

CABLE 

LENGTH

12"

 MAX.

Electrical Circuits

 

The modular table power kit is a 20 Amp, 4-wire, 2-circuit system. The 20 Amp plug infeed 

allows up to 13 circuit-1 duplex receptacles. The hardwire infeed allows up to 13 duplex 

receptacles per circuit for a total of 26. The duplex receptacle(s) in the table power kit and 

every two simplex receptacles from the desktop module count against the 13 duplex 

receptacles allowed for each circuit.  Receptacle faces on the Modular Table Power Kits are 

marked 

I

, for circuit 1 and 

II

, for circuit 2.

Ganging Hardware

Note: All electrical installations must be reviewed with the local authority for 

compliance with local code, and must be performed by a qualified person in 

accordance with codes and regulations applicable at the installation site.

WARNING

Risk of Fire or Electric Shock

WARNING

Risk of Fire or Electric Shock

1. For use in indoor, dry locations only.
2. Read and install in accordance with all assembly directions.
3. Only connect to products labeled "Modular Table Power System" by Steelcase.
4. Do not modify or strain cables. If damaged, remove from service immediately.
5. Disconnect modular electrical connections before servicing or reconfiguring tables.
6. Tables must be held together with ganging hardware as described in this document,
    and NOT held together solely by electrical components.
7. Cable clamps must be no more than 12" from modular cable end connector or receptacle. 

Modular Table Power System Installation

 


background image

Page 6 of 8

939505524 Rev D

Modular Table Power Assemblies
Single Receptacle

SHIPPED COMPONENTS:

- 1 cable assembly

- 1 hardware kit

HARDWARE:

- 1 receptacle bracket

- 4 conduit clamps

- 2 conduit snap-clips

- 8 #10 phillips head screws - black

TOOLS REQUIRED:

 #2 phillips head driver                            #2 phillips head driver

Double Receptacle

SHIPPED COMPONENTS:

- 1 cable assembly

- 1 hardware kit

HARDWARE:

- 2 receptacle brackets

- 5 conduit clamps

- 2 conduit snap-clips

-11 #10 phillips head screws - black

TOOLS REQUIRED:

Table Width
Table Depth
24"
30"

48"

60"
54"

60"

72"
66"

72"

84"
78"

Cable Assembly Length

Installing Modular Cable for End-to-End Applications

1. 

Carefully place table top upside down 

     onto rug or other soft, clean surface.

  

2. 

Single receptacle

 

Identify the conduit path by locating (8) cable attachment holes:

(2) for receptacle bracket, (4) for conduit clamps and

(2) for conduit snap-clips.

Double receptacle

Identify the conduit path by locating (11) cable attachment holes: 

(4) for receptacle brackets (5) for conduit clamps and (2) for conduit snap-clips.

If holes for double-receptacle brackets are not provided, use bracket as a template

to mark hole locations near single-receptacle holes.  Drill holes .157" dia x .50" deep.

NOTE: Conduit clamps may be relocated for better cable fit.

Drill clamp holes .157" dia x .50" deep.

2

Cable attachment hole

locations for 

single

receptacle cable.

Cable attachment hole

locations for 

double

receptacle cable.

2

 


background image

Page 7 of 8

939505524 Rev D

Installing Modular Cable for End-to-End Applications (continued)

9. 

Carefully flip tables upright into use position.

3. 

Fasten receptacle bracket(s).

4. 

Fasten conduit snap-clips.

5. 

Loosely fasten conduit clamps.

6. 

Determine direction of power and orient male and female ends of cable 

     assembly as required.  Align ends flush with table edges and snap into clips.

     

Note: Infeed has a female connector.   

7. 

Snap receptacle(s) into receptacle bracket(s).

8. 

Tighten conduit clamps.

WARNING

Risk of Fire or Electric Shock

10.

 Make ganging connections between adjoining tables.

           - Lack of mechanical connection may lead to cable damage. 

11.

 Connect modular connectors.

           - Match like colors only. (Green-to-Green, Red-to-Red,
             Black-to-Black and White-to-White). Push connectors
             together until both latches engage.

11

Male end of Modular

Table Power Cable

Female end of Modular

Table Power Cable

GREEN

BLACK

WHITE

RED

GREEN

BLACK

WHITE

RED

Note: Latches 

fully engaged.

Note: Orient colors on both 

connectors to match.

CABLE 

CONNECTOR

CONDUIT 

SNAP-CLIP

CONDUIT CLAMP

RECEPTACLE 

BRACKET

5

6

3

4

RECEPTACLE

7

8

 


background image

Page 8 of 8

939505524 Rev D

Cable Routing Restrictions

 

In order for the flip-top mechanism to work properly,

the mechanism area - handle, swing arm, top pivot

and bumpers - must be free of any obstructions.

When routing power cables, follow the recommended

conduit path described on page 6, and avoid the

shaded areas in the illustration shown on this page.

Flip-Top mechanism must move 
freely in shaded areas shown. 