Full Text Searchable PDF User Manual

User’s Manual
Copyright © 2016 CO2 Meter, Inc. All Rights Reserved. Rev. March 16, 2016
CO2
Sampling
Data
Logger
Models
Covered
CM‐0001 CM‐0002
CM‐0003
CM‐0050 CM‐0056
See Table 1 on page 7 for details.
WARNING!
Install
our
complimentary
GasLab
®
software
before
connecting
your
CO2Meter
product(s)
to
your
computer.
Failure to do so may affect the ability for GasLab
®
to detect your meter.
Save
meter
information
for
future
reference
Model Number:
Serial Number:
Purchase Date:

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
2
of
17
WARNING!
Install
our
complimentary
GasLab
®
software
before
connecting
your
CO2Meter
product(s)
to
your
computer.
Failure to do so may affect the
ability for GasLab
®
to detect your meter. If this happens, please follow the
instructions in the “
USB
Driver
Installation
Instructions
” section on page 15 of
this manual.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
3
of
17
Contents
WELCOME
...................................................................................................................
4
IMPORTANT
SAFEGUARDS
...................................................................................
4
PACKAGE
CONTENTS
..............................................................................................
5
O
PTIONAL
A
CCESSORIES
............................................................................................................ 5
GASLAB®
SOFTWARE
............................................................................................
5
G
AS
L
AB
®
S
OFTWARE
I
NSTALLATION
.................................................................................... 6
M
INIMUM
S
YSTEM
R
EQUIREMENTS
........................................................................................ 6
PRODUCT
OVERVIEW
.............................................................................................
7
P
RINCIPAL OF
O
PERATION
........................................................................................................ 7
I
NSTRUMENT
O
VERVIEW
........................................................................................................... 8
LCD
D
ISPLAY
.............................................................................................................................. 8
QUICK
START
GUIDE
..............................................................................................
9
P
OWERING THE
M
ETER
............................................................................................................. 9
OPERATION
...............................................................................................................
9
C
ONNECTING THE
M
ETER TO YOUR
PC ................................................................................... 9
D
ATA
S
TORAGE
........................................................................................................................ 10
DATA
LOGGING
......................................................................................................
10
SETTINGS
................................................................................................................
11
D
ISPLAY
S
ETTINGS
.................................................................................................................. 11
P
ORT
S
ETTINGS
........................................................................................................................ 11
T
IME
/D
ATE
S
ETTINGS
............................................................................................................ 11
L
OGGING
S
ETTINGS
.................................................................................................................. 11
USING
THE
FILTERS
.............................................................................................
11
CALIBRATION
........................................................................................................
12
C
ALIBRATION
P
ROCEDURE
..................................................................................................... 13
APPENDIX
...............................................................................................................
14
M
ETER
S
PECIFICATIONS
......................................................................................................... 14
TROUBLESHOOTING
GUIDE
..............................................................................
15
USB
D
RIVER
I
NSTALLATION
I
NSTRUCTIONS
...................................................................... 15
SUPPORT
.................................................................................................................
16
WARRANTY
............................................................................................................
16
LIABILITY
................................................................................................................
16
RETURNS
.................................................................................................................
16
CONTACT
US
...........................................................................................................
17

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
4
of
17
Welcome
Thank you for purchasing our meter. CO2Meter, Inc. is a Florida based business specializing in the design and
manufacturing of gas detection and monitoring devices – mainly CO2. Our approach is one based in the science of
gas and how best to accurately and repeatedly measure that gas for the end users purposes. Our business partners
in Agriculture, Medical, Pharmaceuticals, Science, Beverage, and other fields find our devices to be highly accurate
and cost effective.
We approach each customer’s application as a unique opportunity to understand, educate, and provide product
solutions that meet the customers’ needs while exceeding their expectations for reliability and service. Our
continued product innovation in combination with our “customer first” focus allows CO2Meter, Inc. to continue to
provide solutions for the future.
Based in Ormond Beach, FL, CO2Meter, Inc. is committed to the success of our customers; the health, welfare, and
prosperity of our talented employees; and the continued development of our local community.
CO2Meter, Inc. appreciates your business and looks forward to working with you and your team in the future.
Please take some time to read through this manual in order to become familiar with the meter. Also, please pay
special attention to the important safeguards.
Important
Safeguards
To reduce the risk of fire, electrical shock and/or injury to persons, basic safety precautions should always be
followed when using electrical appliances, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS METER.
INSTALL GasLab
®
SOFTWARE BEFORE CONNECTING METER TO A COMPUTER.
Use only the included power supply to operate this meter. Inappropriate voltage supply could cause
irreparable damage to this device.
Do NOT use rechargeable AA batteries.
Duracell brand AA Alkaline batteries are recommended
Do not store the meter with the AA Alkaline batteries installed to prevent the potential for battery leakage.
Make sure that the tubes are securely attached to the meter before sampling a closed environment.
Do not operate with an obstructed sample path.
This meter is not designed for outdoor use.
Do not expose this meter to water or any liquids.
Do not operate this meter if the enclosure is opened.
Do not operate the device if it is malfunctioning.
SAVE THESE INSTRUCTIONS!

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
5
of
17
Package
Contents
Please verify that your package contains the following items before using the meter:
ALL UNITS:
(1) Meter
(1) Protective rubber grips
(1) 6‐foot USB cable
(1) International power supply
(1) High‐impact carrying case
(1) Certificate of calibration
(1) User manual
(1) 10‐foot long 1/8” tubing
(2) ¼ 28 UNF Locking Nut
(2) ¼ 28 Panel Mount Connector
(2) Male Luer Lock Connectors
(2) Luer Lock Caps
(2) 1/8” Barb tubing bulkhead
(2) 1/8” Barb 10‐32 UNF fittings
(2) Particulate filter (CM‐0117)
(2) Hydrophobic filter (CM‐0118)
(1) Moisture trap (CM‐0112)
Optional Accessories
If the meter is to operate in environments where humidity is very high (>95% RH), an
Extreme
Moisture
Filter
(CM‐
0103) can be purchased separately. This filter will allow free flow of sampled air while keeping moisture out of the
meter. A 10,000 Hr. pump is also available at the time of purchase.
Note
: Please contact our technical support staff for more details about these accessories.
NOTE:
We strongly recommend allowing GasLab
®
to install drivers for the meter automatically.
GasLab®
Software
Our GasLab
®
software allows you to:
Manage and download logs
Configure the sensor(s)
Adjust logging intervals
Calibrate the meter
Automatic data logging when meter is powered ON
Data logging session status displayed on LCD screen
Collect data real‐time
Figure
1:
Basic
kit
‐
all
units

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
6
of
17
GasLab® Software Installation
IMPORTANT:
M
AKE
SURE
TO
INSTALL
SOFTWARE
BEFORE
CONNECTING
YOUR
METER
TO
YOUR
COMPUTER
.
Minimum System Requirements
To utilize our complimentary software, the computer must meet the following minimum requirements:
1GHz processor with 1GB RAM, 1GB free disk space (2GB free disk space for 64‐bit systems).
Windows XP*/7/8/8.1 with Microsoft .NET Framework 4.0** or later.
On Intel‐based Mac computers, GasLab
®
software can run using a Windows 7/8 virtual machine software
such as
VMware
Fusion®
or similar.
*Microsoft .NET is not supported on Media Center or Tablet editions.
**Installer will optionally install .NET Framework.
Visit
www.co2meter.com/pages/downloads
to download our complimentary GasLab
®
software to your
computer. You can also download the GasLab
®
user manual in PDF from this page.
Please read the GasLab
®
user manual carefully to become more familiar with how the software works so that you
can get the maximum benefit from this useful tool.
Install the GasLab
®
software first to ensure that the proper driver, necessary for the meter, is installed on your
computer before connecting the meter.
Figure
2:
GasLab
®
download
page
(Internet
Explorer
11
shown)
Follow the steps and instructions prompted by your computer’s operating system. Make sure you have
administrator privileges in order to install this program.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
7
of
17
Product
Overview
This portable battery‐powered CO2Meter, Inc. meter is designed to measure carbon dioxide (CO2) in real time in
inaccessible areas for applications such as, but not limited to fermentation vats & barrels, biological incubators,
and CO2 leak detection.
Meters with logging capabilities are designed to record CO2 concentration level data over periods of time. It stores
up to 60,000 collected data points to its internal memory to be retrieved at a later time for analysis. When
combined with our GasLab
®
software, you can also see real‐time data on your computer’s screen. These meters are
ideal for applications such as, but not limited to CO2 monitoring of products with modified atmosphere packaging
(MAP), monitoring of mold production in areas used to store grains, and testing of fire suppression systems.
Its built‐in 1,000 hours sampling micro‐pump (10,000 Hr. optional) ensures reliable operation for persistent
readings based on user‐selected time intervals.
Scientific devices such as this sampling meter require users to have intimate knowledge of the meter’s features,
limitations, operation, required software, and specifications prior to use. CO2Meter, Inc. highly recommends
reading this user’s manual before operating this meter, especially the
Important
Safeguards
section on page 4.
The table below shows all available models and their respective characteristics.
Table
1:
Meter
models
covered
in
this
manual
Model
#
(P/N)
CO2
Level
Meter
Type
CM‐0001
1%
Sampling Logger
CM‐0002
30%
Sampling Logger
CM‐0003
100%
Sampling Logger
CM‐0050
60%
Sampling Logger
CM‐0056
5%
Sampling Logger
Principal of Operation
The CO2 sensor inside this meter uses proven NDIR (non‐dispersive infrared) technology to sense, as a function of
transmitted light, the concentration of CO2 in the air.
Air from the tube inlet port is pulled into the sensor’s CO2 molecule detection chamber by a micro‐pump, then
expelled out the tube outlet port.
The measured CO2 level is shown on the LCD in real time and/or logged into memory with a date/time stamp for
later retrieval.
The meter is factory calibrated to operate within the specified range and precision.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
8
of
17
Instrument Overview
LCD Display
The Liquid Crystal Display (LCD) shows the following features:
CO2 concentration level in parts‐per‐million (ppm) for 1% and 5% models
CO2 concentration level in percentage format (##.##%) for all other models
Logging ON/OFF
Percentage of free memory
Display
Shows CO2
concentration
level, data
logging and free
memory space.
Power
Jack
Connect included
power supply.
Power
Switch
Turns the meter
ON/OFF.
LOG
Switch
Turns logging &
pump ON/OFF.
Inlet
Outlet
Rubber
Boot
(x2)
Protects meter
and improves grip.
Barb
Fitting
(x2)
USB
Connector
(covered)
Connect included USB cable
to communicate with unit.
USB
Connector
(cover
removed)

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
9
of
17
Quick
Start
Guide
IMPORTANT:
M
AKE
SURE
TO
INSTALL
GASLAB
SOFTWARE
BEFORE
CONNECTING
YOUR
METER
TO
YOUR
COMPUTER
.
1.
Install fresh set of AA batteries (Duracell brand recommended) or connect the included power supply.
2.
Install filters and tubing included as shown on Figure 6 as required.
3.
Turn the meter ON by pressing the power switch once.
4.
Turn logging ON by pressing the LOG switch once. Once the sampling process is completed, data can be
downloaded to your computer using our GasLab
®
software.
Powering the Meter
This meter can be powered by four (4) AA size batteries (not included) but sampling units can also be powered by
the included 6VDC international wall power supply. These units should NOT be powered using the included USB
cable since it supplies inconsistent voltage to the meter, which degrades sensor accuracy.
If the unit is not going to be used for an extended period of time, batteries should be removed to prevent damage
due to potential battery leakage.
The POWER switch
on the left side of the meter turns the unit ON/OFF. The LOG switch on the right side of the
meter enables/disables data logging and pump function.
Operation
Make sure you read through these instructions thoroughly before using the meter. This guide will help you become
more familiar with the meter in order to be as productive as possible in a short period of time. Please read the
Important
Safeguards
on page 4 before continuing.
IMPORTANT:
Follow
these
instructions
to
ensure
proper
set
up:
1.
Download the GasLab
®
software to your computer as shown in the
GasLab
®
Software
section on page 6.
2.
Power the meter using the included universal power supply. Turn
ON
the meter.
3.
Wait until the display changes colors to visually confirm it has reset successfully after connecting it to a
computer.
Connecting the Meter to your PC
The first time the meter is connected to your computer, the operating system will install the necessary USB drivers
as shown in
Figure
3.
This process could take a few minutes.
Figure
3:
USB
Driver
Installation.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
10
of
17
Data Storage
This meter features an internal memory capable of storing 60,000 data points. Due to the nature of their design,
these meters will need to be initialized before operation and its logging period and real‐time clock will need to be
set under the “Settings” menu.
Once the GasLab
®
software has been installed and the meter is connected to the computer, you can gather data in a
variety of ways. Data can be collected in real time, data logs can be downloaded from the meter’s memory and
saved to the computer, and data can be reviewed on the meter’s LCD display.
For
each
logging
session:
1.
Turn the meter ON.
2.
The meter must be started at least 1 minute prior to deployment and data logging to allow the CO2 sensor
time to warm‐up and calibrate.
3.
Start logging by pressing the “Log” button on the right side of the meter.
4.
When data logging is completed, turn the “Log” OFF.
NOTE:
Refer to the GasLab
®
User’s Manual for more information.
Data
Logging
These models feature an internal memory capable of storing data when not connected to a computer. This allows
you to simultaneously read and store CO2 concentration level data. You can download the data logs by connecting
the data logger to GasLab®.
• Data logging is only available when the meter is turned ON.
• Start data logging by pressing the switch on the right hand side of the device. When the switch is depressed to
the ON position, it will activate the pump and start data logging. This button is the only way to turn on the pump
and data logging.
• When the same switch is pressed again and raised to the OFF position, the pump and data logging will stop.
All CM Data Loggers are preconfigured to sample the air from the inlet tube port once every five seconds. If this
does not work for your application, contact a CO2Meter technician for instructions on how to modify the sampling
rate.
IMPORTANT:
A
LTERING
THE
PUMP
PERIOD
,
DATA
LOGGING
INTERVAL
,
PWM
PERIOD
OR
PUMP
MODE
IN
G
AS
L
AB
®
TO
CHANGE
THE
SAMPLE
RATE
WITHOUT
SPEAKING
WITH
A
CO2M
ETER
TECHNICIAN
FIRST
MAY
VOID
YOUR
WARRANTY
.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
11
of
17
Settings
Settings – allows you to access all the parameters, options, outputs, communications, and date/time settings to be
changed or programmed.
Display Settings
Here you can change the brightness and color theme (3 available) on the device and you can also activate a Screen
Timeout to save power. This setting will not affect the meter’s functionality but will affect the battery life
depending on how you set this parameter.
Port Settings
Here you can configure and activate ports that control additional accessories such as the device Modbus address.
Please call technical support for guidance and important information before making changes to the configuration
of any of these ports.
Time/Date Settings
Here you can change the date and time on the meter for more accurate reference on the records. The default time
of your meter could vary depending on your location.
Review
these
settings
before
you
start
using
the
meter.
Logging Settings
All CM Data Loggers are preconfigured to sample once every five seconds. If this does not work for your
application, contact a CO2Meter technician for instructions on how to modify the sampling rate.
IMPORTANT:
A
LTERING
THE
PUMP
PERIOD
,
DATA
LOGGING
INTERVAL
,
PWM
PERIOD
OR
PUMP
MODE
IN
G
AS
L
AB
®
TO
CHANGE
THE
SAMPLE
RATE
WITHOUT
SPEAKING
WITH
A
CO2M
ETER
TECHNICIAN
FIRST
MAY
VOID
YOUR
WARRANTY
.
Using
the
Filters
In order to use this meter properly, hoses/tubing must be attached to the inlet and outlet barb fittings securely.
The pump will draw air from the inlet by vacuum effect, push it to the sensing chamber through the sensor, and
then exhaust the air outside the meter through the outlet.
Closed
Loop
Operation
Figure
4:
Closed
Loop

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
12
of
17
Open
Loop
with
Environmental
Exhaust
Figure
5:
Open
Loop
We recommend installing the included humidity/contaminant filters to ensure the sensing chamber and pump
baffle stays clear and corrosion‐free. Replacements filters are available on CO2meter.com.
Figure
6:
Filter
Installation
and
Orientation
Calibration
All units are factory‐calibrated with multiple reference points of gas, and have been verified to be accurate within
their specific functionality before shipment. However, if the unit is severely jolted or otherwise mechanically
disturbed, the sensor can drift requiring recalibration. All calibration procedures follow a single‐point calibration
routine that effectively shifts the zero‐point of the CO2 sensor.
Supply calibration gas to the unit and connect the unit to a personal computer. Open the calibration screen in the
GasLab
®
software. Click the
CALIBRATE
button in the calibration tab for the desired gas, located in the
CONFIGURE
SENSOR
screen. As long as the gas concentration is stable, the unit should instantly reflect the
calibrated value. This can be confirmed by watching the display. To see the calibration value in real time, click in
the
COLLECT
REAL
‐
TIME
button to capture these values before opening the configuration screen.
Particulate
Filter

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
13
of
17
1%
or
30%
Sampling
Data
Logger
Calibration can be performed using either 100% CO2 calibration gas (typically nitrogen, argon, etc.), or using a
fresh source of air, assumed to be approximately 400ppm.
NOTE
: Refer to the GasLab
®
User’s Manual for complete instructions.
Calibration Procedure
To calibrate your meter, follow these steps:
1.
Turn ON the meter.
2.
Expose the meter to ambient air (assumed to be at 400ppm) or supply calibration gas bottle/cylinder
(100% nitrogen or argon) with the appropriate demand regulator.
3.
Wait 25 seconds to collect a sample. Write down this value as the “before” value.
4.
Click the
CALIBRATE
button after selecting your calibration gas.
5.
Wait 25 seconds again. This time, the meter will take a sample and use this data to adjust zero values. The
displayed measurement will show the new calibration value (0 or 400ppm, depending on method used).
6.
Disconnect the Calibration gas and wait 25 seconds. All displayed data will now be based on the new
calibration value. Repeat this procedure if the sensor is still operating outside of its specified range or if
readings vary greatly.
5%,
60%,
and
100%
Sampling
Data
Logger
These models do not feature Automatic Background Calibration (ABC) algorithm due to the CO2 scale they
measure. To ensure the highest accuracy, we recommend calibrating these units with calibration gas (Nitrogen for
ZERO or CO2), close to the concentration being measured. Alternatively, a 100% or ambient calibration can be
performed.
To perform a calibration, attach the unit to your computer, power it with the wall adapter and either expose it to
atmosphere or supply it with your calibration gas, fed with a demand‐based regulator.
Open the GasLab
®
software on your personal computer and click the
CONFIGURE
SENSOR
button. Click the
TURN
PUMP
ON
CONTINUOUSLY
button to ensure continuous flow. (To apply any changes, the meter has to be
restarted). Make sure to turn this back off after calibration.
Zero
or
Fresh
Air
Calibration
Supply gas and select the appropriate concentration in the screen. Click the
CALIBRATE
button. The sensor reading
should instantly reflect the calibration.
High
‐
Concentration
Calibration
Write down the original Zero Value before adjustment for future reference. Apply the desired concentration
calibration gas; adjust the Zero Value in increments of 10 pressing the large
SAVE
button on the right until the unit
displays the correct concentration.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
14
of
17
Appendix
Meter Specifications
CO2
Sensor
Performance
and
Ratings
Sensor
Type
Non‐dispersive infrared
(NDIR)
Measuring
Range
0‐10,000 ppm (1% CO2)
0‐50,000 ppm (5% CO2)
0‐30% vol. (30% CO2)
0‐60% vol. (60% CO2)
0‐100% vol. (100% CO2)
Accuracy
±30 ppm, ±5% of measured
value
Repeatability
±20 ppm, ±1% measured
value (1% models)
±0.1%, ±2% of measured
value (all other models)
General
Warm
‐
up
Time
<1 min. (instant
measurements)
Life
Expectancy
>15 years
Maintenance
Interval
No maintenance required
Data
Logging
Data
Points
60,000
Programmable
Interval
Data
Date, time, CO2, O2 (every 15
seconds to 18 hours)
Pump
Characteristics
Max.
Flow
(STP)
500 ml/min @ STP
Max.
Vacuum
150 mbar
Max.
Pressure
500 mbar
Max.
System
Pressure
~101.3 KPa (1 atm.)
Life
Expectancy
1,000 (standard), depending
on sampling interval
Power
Input
Voltage
6 VDC
Method
Power supply or 4x AA
batteries
Power
Consumption
~0.5 Watt. Avg. (pump
running)
Dimensions
WxHxD
in(mm) 4.8(122) x 7.1(181) x 2.1(55)

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
15
of
17
Troubleshooting
Guide
Symptom
/
Issue
Possible
Cause
/
Resolution
Meter not
recognized by
computer/OS
Your device’s batteries might be depleted. Replace the batteries
with fresh ones, or make sure the power supply is connected
properly (use the included power supply only).
Device
doesn’t power
ON
Make sure the power supply is connected properly and that
there is power in the outlet the adapter is connected has the
appropriate voltage. If using batteries, make sure they are not
depleted.
The GasLab
®
software
doesn’t start *
Your software might be out of date. Update your software by
either visiting our download webpage at
http://www.co2meter.com/pages/downloads
or by selecting
the “
Check
for
Updates
” under the
Help
menu. Make sure your
PC meets the minimum requirements.
Slow
response
Check the air flow channels to make sure they are not
obstructed.
Reading
doesn’t
change
Make sure the meter is in maximum or minimum mode.
“Bat” and
green LED
keep flashing
The power supply output voltage is inappropriate or batteries
depleted. Please use the included power supply only or replace
batteries with a fresh set.
*For more troubleshooting tips on GasLab
®
software, see its manual located at
www.co2meter.com/pages/downloads
.
USB Driver Installation Instructions
To install the appropriate USB port drivers compatible with your meter, follow these steps:
1.
Go to
http://www.ftdichip.com/Drivers/VCP.htm
and download the package appropriate for the version of
Windows installed in your computer.
2.
Move the file you downloaded to a location you can easily access. Make sure you have administrator
privileges.
3.
Extract the file by right clicking on it and selecting
extract
here.
4.
Go to your computer’s Device Manager in the
Control
Panel
.
For Windows 8, press the Windows key and 'x' at the same time to bring up the start menu then click on
Device
Manager
.
For Windows 7, open the start menu and type
Device
Manager
in the search bar.
5.
Find the
Unrecognized
USB
Device
in the list (it usually, but not always, has a yellow triangle icon).
6.
Right click the
Unrecognized
USB
Device
item and select
Update
Driver
Software
.
7.
Select
Browse
My
Computer
and point to the folder where you extracted the driver files to (step #3).
This will install the necessary drivers to your computer and allow you to use your meter with GasLab
®
. If you have
multiple sensors you should only have to perform this procedure once; the operating system will automatically
find the driver for all the other sensors.

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
16
of
17
Support
The quickest way to obtain technical support is via email. Please send all support inquires to
support@co2meter.com
.
Please include a clear, concise definition of the problem and any relevant troubleshooting information or steps
taken so far, so we can duplicate the problem and quickly respond to your inquiry.
Warranty
This meter comes with a 1YEAR (warranty period) limited manufacturer’s warranty, starting from the date the
meter was shipped to the buyer.
During this period of time, CO2Meter.com warrants our products to be free from defects in materials and
workmanship when used for their intended purpose and agrees to fix or replace (at our discretion) any part or
product that fails under normal use. To take advantage of this warranty, the product must be returned to
CO2Meter.com at your expense. If, after examination, we determine the product is defective, we will repair or
replace it at no additional cost to you.
This warranty does not cover any products that have been subjected to misuse, neglect, accident, modifications or
repairs by you or by a third party. No employee or reseller of CO2Meter.com’s products may alter this warranty
verbally or in writing.
Liability
All liabilities under this agreement shall be limited to the actual cost of the product paid to CO2Meter.com. In no
event shall CO2Meter.com be liable for any incidental or consequential damages, lost profits, loss of time, lost sales
or loss or damage to data, injury to person or personal property or any other indirect damages as the result of use
of our products.
Returns
If the product fails under normal use during the warranty period, a RMA (Return Material Authorization) number
must be obtained from CO2Meter.com. After the item is received CO2Meter.com will repair or replace the item at
our discretion.
To obtain a RMA number, call us at or email us at (386) 256‐4910
support@co2meter.com
. When requesting a
RMA please provide reason for return and original order number.
If we determine that the product failed because of improper use (water damage, dropping, tampering, electrical
damage etc.), or if it is beyond the warranty date, we will inform you of the cost to fix or replace the product.
For more information visit our website:
www.CO2Meter.com/pages/faq

Sampling Data Logger User’s Manual
CO2Meter.com
PAGE
17
of
17
Contact
Us
We
are
here
to
help!
For information or technical support, please contact us.
support@co2meter.com
(386) 256‐4910 ( Technical Support)
(386) 872‐7665 (Sales)
www.co2meter.com
Address:
CO2Meter, Inc.
131 Business Center Drive
Ormond Beach, FL 32174
USA