PDF User Manual

  1. Home
  2. Manuals
  3. Cloud RL-1 Installation Manual

Cloud RL-1 Installation Manual

RSL-4A RL-1A RSL-4 RSL-6 RSL-6A

Made by: Cloud
Type: Installation Guide
Category: Remote Control
Pages: 16
Size: 0.57 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

1

RL-1, RL-1A,  RSL-4, RSL-4A,  

RSL-6, RSL-6A

Remote Control Plates

Installation Guide

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

2

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

3

Contents

Introduction ...................................................................4

Remote plate types ................................................................................. 5
Compatible Cloud products.................................................................. 6

Single and multi-channel operation ...................................................... 8

Device configuration

 ............................................................................... 9

Wiring details .........................................................................................11
CX163 stereo control options ...........................................................13
Wiring diagrams .....................................................................................14

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

4

Introduction

Cloud RL and RSL remote control plates are accessories for a wide range 

of Cloud zoners, mixer-amplifiers and power amplifiers. They are compatible 

with all current (relevant) products, and also with numerous discontinued 
products.

RL plates adjust the signal level in an audio channel of a Cloud device, and 

thus allow audio volume in an area to be controlled locally.

RSL plates provide the same volume control function as RL plates, 
but additionally allow remote selection of music source, when used in 
conjunction with Cloud devices that have multiple line inputs.

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

5

Remote plate types

Functionally, there are three models of remote plate:

• 

RL-1:  provides remote volume control of an audio channel.

• 

RSL-4:   provides remote volume control of an audio channel, and also 

remote selection of the music source for that channel, when 
used with devices having up to four line inputs.

• 

RSL-6:  as RSL-4, but for use with devices having up to six line inputs.

All three plates fit standard UK-style single-gang electrical back boxes, either 

surface-mounting or flush-fitting. Recommended back box depth is 25 mm. 
Two M3.5 x 20 fixing screws are supplied with each plate.

US Versions:

The RL-1A, RSL-4A and RSL-6A are electrically and functionally identical, 
but the faceplates have different physical dimensions (4.51”x  2.76”) 
which allow them to be mounted into a standard US-style back box (with 

vertical orientation). All information in this manual applies equally to both 
mechanical versions.

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

6

Compatible Cloud products

The table below summarises which current Cloud products are compatible 

with each type of plate. For older products, please consult the product’s 
Installation Guide, 

www.cloud.co.uk

, or contact Cloud’s Technical Dept.

PRODUCT

RL-1/1A

RSL-4/4A

RSL-6/6A

Venue Mixers

Z4

II

Z8

II

Zone Mixers

CX163

CX263

CX261

CX462

Integrated Mixer-amplifiers

MA60

MA60

MEDIA

36/50

46/50

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

7

Power amplifiers

RL-1/1A

RSL-4/4A

RSL-6/6A

MPA60

 

MPA120

MPA240

CXV225*

CXV425*

CXA450*

CXA850*

CXA6*

VTX4120

VTX4240

VTX4400

* These models require VCA cards to be installed before they can be used with remote control plates.    
Full installation instructions are provided with the VCA card kit, and can also be found in the Installation Guide for 

the model.

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

8

Single and multi-channel operation

RL and RSL remote plates are primarily designed to provide remote control 
of a single audio channel. A single channel will often correspond to a single 
zone or area of a building, and the remote plate will therefore control the 

audio in that zone, but see NOTE below. Many of the products listed above 

have two or more audio channels; on all such Cloud devices, provision is 
made for connecting separate remote control plates to as many channels as 

required. (The CX163 stereo zone mixer has a slightly different arrangement; 

see 

Wiring details

 on page 11 and 

Wiring diagrams

 on page 14 for further 

information).

NOTE:

 

It is possible to control two or more channels of a Cloud multi-

channel device “in parallel” from a single remote plate; this might be desirable 

where, e.g., more than one channel of a mixer-amplifier is powering speakers 

in the same zone, due to room size.

An RL-1/1A may be wired in parallel to more than one channel of an 

amplifier or zoner, but note that the “law” of the control will differ from that 

obeyed when it is used with a single channel. When wired to several channels 
in parallel, this may produce an inconvenient “cramping” of the control’s 

operation at one end of the range.

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

9

The RSL-4/4A and RSL-6/6A remote control plates require modifications 
for multi-channel operation. This topic is NOT covered in this manual. 

Installers requiring this option should download the appropriate Cloud 

Technical Note from 

www.cloud.co.uk,

 and carry out the modifications 

described before installing the plates.

Device configuration

Most RL/RSL-compatible Cloud products will require minor configuration 

changes when remote control plates are installed to ensure correct operation.

RL plates:

When adding RL-1/1A remote control plates, it will generally be necessary 
to disable the front panel music level control, so that volume may be 

adjusted only by the plate. On most units, this is done by operating a rear 
panel push-button switch. However, on devices with multiple music sources, 

doing this will also disable the front panel music source control. To maintain 

control of music source from the front panel, internal jumpers must be set 

to the appropriate position. The products to which this applies are those 

which are also compatible with RSL plates (see 

Compatible Cloud products

 

table on page 6).

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

10

RSL plates:

When adding RSL-4/4A or RSL-6/6A remote control plates, it will generally 
be necessary to disable both the front panel music level and source selection 
controls, so that full control is via the plate. On most units, this can be done 

by operating a rear panel push-button switch.

IMPORTANT

With both types of plate, it is essential that installers check the Installation 

Guide for the specific product to which they are connecting the plates. This 
will give full details of the configuration procedure. If necessary, Installation 

Guides for all products can be found at 

www.cloud.co.uk

.

On multi-channel (or multi-zone) devices, the configuration changes 

necessary for remote control are always per-channel or per-zone. Channels 

(or zones) to which remote control plates are not fitted will operate from 

the unit’s local controls in the normal way.

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

11

Wiring details

In most cases, remote control plates connect to their host devices via per-
channel, 3-pin 5 mm-pitch screw terminal connectors on the device’s rear panel. 

The only exception is the CX163, which has a 4-pin connector. The connector 

will be labelled REMOTE LEVEL, REMOTE LEVEL/SOURCE, REMOTE MUSIC 
CONTROL, or something similar, depending on the device.

On all types of remote control plate, connection at the plate is via a rear 
3-pin screw-terminal connector.

RL plates:

 Connection may be via single- or twin-core screened cable. RL 

plates can generally be connected to devices that support remote music 
source selection using single-core cable, but two-core screened cable is 

required when connecting to devices that do not support this.

RSL plates: These always require twin-core screened cable.
The use of crimp ferrule-type terminals is recommended for the 

cable terminations as this will provide a much more reliable long-term 

connection. Recommended maximum cable length is 100 m (328 ft.)

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

12

The wiring scheme to be adopted varies between devices. See the table 
below to check which of the wiring diagrams on pages 14 and 15 should be 
followed to connect a particular type of plate to a specific device.

PRODUCT

RL-1/1A

RSL-4/4A

RSL-6/6A

Venue Mixers

Z4

II

A

E

Z8

II

A

E

Zone Mixers

CX163

C or D*

CX263

A

E

CX261

A

E

CX462

A

E

Integrated Mixer-amplifiers

MA60

A

E

MA60

MEDIA

A

E

36/50

A

E

46/50

A

E

Power amplifiers

MPA60

A

E

MPA120

A

E

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

13

MPA240

A

E

CXV225*

B

CXV425*

B

CXA450*

B

CXA850*

B

CXA6*

B

VTX4120

B

VTX4240

B

VTX4400

B

*See note below

CX163 stereo control options

The CX163 is a two-zone stereo mixer and has a different remote control 

connector to other Cloud units. When using RL remote level control 
plates with a CX163, the installer has the option of using a single RL plate 

to control both left and right channels together (i.e., stereo operation), 
or of using two separate RL plates to control the left and right channels 

independently. For stereo operation, use wiring diagram C. For separate L/R 
control, use wiring diagram D.

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

14

Wiring diagrams

1 2 3

REMOTE MUSIC

CONTROL

CONNECTOR

1 2 3

REMOTE LEVEL CONTROL WIRING

RL-1/1A

SINGLE-CORE SCREENED CABLE MAY BE USED

WIRING DIAGRAM A

RL-1/1A

1 2 3

REMOTE MUSIC

CONTROL

CONNECTOR

1 2 3

REMOTE LEVEL CONTROL WIRING

RL-1/1A

WIRING DIAGRAM B

USE TWO-CORE SCREENED CABLE

1 2 3

REMOTE MUSIC

CONTROL

CONNECTOR

1 2 3

REMOTE LEVEL CONTROL WIRING

RL-1/1A

WIRING DIAGRAM C

USE TWO-CORE SCREENED CABLE

4

 


background image

RL-1, RSL-4, RSL-6 Installation Guide V1.0

15

1 2 3

REMOTE MUSIC

CONTROL

CONNECTOR

1 2 3

REMOTE SOURCE & LEVEL CONTROL WIRING

RSL-4/4A

or

RSL-6/6A

USE TWO-CORE SCREENED CABLE

WIRING DIAGRAM E

RSL-4/4A or RSL-6/6A

1 2 3

1 2 3

REMOTE LEVEL CONTROL WIRING

RL-1/1A

WIRING DIAGRAM D

USE TWO-CORE SCREENED CABLE

4

1 2 3

RL-1/1A

LEFT CHANNEL

RIGHT CHANNEL

(CX163 ONLY)

REMOTE MUSIC

CONTROL

CONNECTOR

RL-1/1A

 


background image

Cloud Electronics Limited

140 Staniforth Road

Sheffield S9 3HF

England

Tel: +44 (0)114 244 7051

Fax: +44 (0)114 242 5462

email: info@cloud.co.uk