LM-2 Installation Guide v1.0

1

LM-2 Series Remote Mic/Line 

Mixer/Control Modules

 

Installation Guide

MIC LEVEL

1

2

3

4

5

6

MUSIC LEVEL

LINE INPUT

MIC INPUT

LM-2

MIC

PRIORITY

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

MIC LEVEL

1

2

3

4

5

6

MUSIC LEVEL

LINE INPUT

MIC INPUT

LM-2D

MIC

PRIORITY

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

MIC LEVEL

1

2

3

4

5

6

MUSIC LEVEL

LINE INPUT

MIC INPUT

MIC

PRIORITY

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

LM-2A

 


background image

LM-2 Installation Guide v1.0

2

Contents

Introduction .................................................................................................................................... 3

Mounting - mechanical .................................................................................................................. 3

Faceplate Controls and Connections ........................................................................................... 4

Block Diagram ................................................................................................................................ 5

Installation - connections .............................................................................................................. 5

Configuring the Facility Port .......................................................................................................................................

7

Connecting multiple LM-2s .........................................................................................................................................

7

Local inputs ..................................................................................................................................................................

7

Remote controls .........................................................................................................................................................

8

LM-2 Priority Operation................................................................................................................ 9

Mic priority: ..................................................................................................................................................................

9

Full priority: ..................................................................................................................................................................

9

Power considerations ................................................................................................................... 10

 


background image

LM-2 Installation Guide v1.0

3

Introduction

The LM-2 is a remote module for use with the following Cloud products:

• 

Z4

MK3

 and Z8

MK3

 Zone Mixers

• 

46-120 and 46-120

MEDIA

 Zone Mixing Amplifiers

It cannot be used with any other Cloud product.
 

NOTE: Unless specifically stated otherwise, all references 

to “LM-2” in this Installation Guide can be taken to apply 

to all LM-2 mechanical and cosmetic variants. 

The LM-2 module combines the functions of a remote input connection plate, local audio mixer and a remote control for the 
host unit’s background music.
Inputs for both a microphone and a stereo line signal (for a local music source) are provided, with individual level controls. The 
stereo channels are summed to mono, and then mixed with the mic input.
The remote control facilities are equivalent to those on a Cloud RSL-6 remote control module, and allow selection of background 
music source and level control for the host’s Zone to which the LM-2 is connected. (Note that the 46-120 and 46-120

MEDIA

 

have a single Facility Port, for Zone 1 only.)
The LM-2 is connected to the host unit’s Facility Port by a single screened Cat 5 cable with RJ45 connectors. A link connector 
is provided to permit multiple LM-2s to be installed in the same Zone.

Mounting - mechanical

LM-2 (UK version)

The Cloud LM-2 fits a standard UK-style dual-gang electrical back box. The box used should have a depth of at least 35 mm.

LM-2A (US version)

The Cloud LM-2A fits a standard US dual-gang electrical ‘J’ box in vertical orientation. The box used should have a depth of at 
least 1¼”.

LM-2D (German/Austrian version)

The Cloud LM-2D fits a DIN-standard double-gang back box (requiring 2 x 68 mm dia cut-outs), of the type used in various 

countries including Germany and Austria. The box used should have a depth of at least 35 mm. 

 


background image

LM-2 Installation Guide v1.0

4

Faceplate Controls and Connections

MIC LEVEL

1

2

3

4

5

6

MUSIC LEVEL

UK version illustrated

LINE INPUT

MIC INPUT

LM-2

MIC

PRIORITY

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

1

4

5

2

3

6

7

9

10

8

0

2

1

3

8

4

5

7

6

1. 

MIC INPUT – 3-pin XLR3F connector for dynamic microphones. Note that the LM-2 does not provide phantom power.

2. 

LINE INPUT (a) – 2 x phono (RCA) sockets for connection of sources such as CD players, audio mixers, radio mic 

receivers, etc; suitable for line level signals with a nominal level of 0 dBu.

3. 

LINE INPUT (b) – 3-pole 3.5 mm jack socket for connection of sources such as computers, laptops and digital media 

players; suitable for line level signals with a nominal level of +8 dBu. A source plugged into this input will be summed to 

mono and mixed with any source connected to the phono inputs 

2

.

NOTE: Both stereo line inputs are summed internally to mono; hence, if using a mono source such as a radio mic receiver, only 
one channel need be connected.
4. 

MIC LEVEL – gain control for mic input. Up to 60 dB gain is available; with the control fully anti-clockwise, the input is 

effectively ‘off’.

5. 

MUSIC LEVEL – gain control for whichever line input (

2

 or 

3

) is in use. With the control fully anticlockwise, the source 

will be ‘off’; in the fully clockwise position, 10 dB of gain is provided.

6. 

MIC PRIORITY – default function for this button is to give the microphone input priority over both the module’s line 

input and the background music selected at the host unit. This operation can be modified by jumpers on the rear PCBs. See 
“LM-2 Priority Operation” on page 9.

7.  BACKGROUND MUSIC SOURCE 

 – six-position switch selecting which of the host unit’s six Line Inputs will be routed 

to the Zone to whose Facility Port the LM-2 is connected (usually the Zone where the LM-2 is installed).

8.  BACKGROUND MUSIC LEVEL 

 – adjusts the background music level in the Zone.

NOTE: Switches and internal jumpers will need to be set in the host unit in order for the background music controls 

7

 and 

8

 

to operate as required. See “Remote controls” on page 8.

 


background image

LM-2 Installation Guide v1.0

5

Block Diagram

RJ45

RJ45

Installation - connections

The LM-2 has two PCBs mounted on the rear of the faceplate. The OUTPUT RJ45 connector is located on the upper PCB while 
the LINK RJ45 connector is on the lower:

OUTPUT

LINK

(

‘DIN’ version illustrated

. Sketch simplified; only primary

components shown)

LOCATION OF REAR RJ45 CONNECTORS

 


background image

LM-2 Installation Guide v1.0

6

The LM-2’s OUTPUT connector should be connected to the host unit’s FACILITY PORT for the Zone in which it is installed* 

with 

screened

 Cat 5 cable and shielded RJ45 plugs.

 

LINK

OUTPUT

LM-2

 

(UK version illustrated)

100 m max

Connect to 

OUTPUT socket

Connect to 

FACILITY PORT

Screened 

Cat 5 cable

The maximum total Cat 5 cable length should not exceed 100 m. If further modules are being “linked” together (see below), 
this figure applies to the overall cable run from the host unit to the “furthest” module in the chain.

 

IMPORTANT: Because the cables carry low-level audio, 

only 

screened Cat 5 should be used, the foil screen of the cable being 

bonded to the metal screening can of the plugs. If an LM-2 is being installed in very close proximity to the host unit, it 

may

 be 

possible to use ready-made screened Cat 5 “patch” cables of short length. In all other situations, shielded RJ45 plugs should be 
crimped onto the installed screened Cat 5 cable using the pinout shown below.

   

PIN

USE

Cat 5 CORE

1

Audio ‘cold’ phase (-)

White + Orange

2

Audio ‘hot’ phase (+)

Orange

3

Priority VCA control

White + Green

4

+15  V

Blue

5

0 V

White + Blue

6

-15  V

Green

7

Music level control (0 to 10  V)

White + Brown

8

Music source select control (0 to 10  V)

Brown

SCN

Screen for system music controls

Connector shell

* There is no reason why the module cannot be connected to the Facility Port of a Zone other than that in which it is installed – though this is likely to be an 
unusual installation scenario. 







 


background image

LM-2 Installation Guide v1.0

7

Configuring the Facility Port

The mic and line inputs on the LM-2 module will be available in the Zone as soon as the module is connected to the host unit’s 

Facility Port for that Zone. The volume of the mic and line inputs will be determined solely by the level controls on the LM-2 

faceplate and unaffected by any of the host unit’s front panel controls.
In order for the remote control section (background music source and level controls to operate correctly), the host unit must 

be set for remote control operation.

Z4

MK3

 and Z8

MK3

:

Set the 

MUSIC CONTROL button on the host unit’s rear panel to REMOTE (in) for the Zone in use. The button is adjacent 

to the REMOTE SOURCE + LEVEL connector immediately above the FACILITY PORT. This will disable the host unit’s front 

panel music source and level controls for the Zone.
Sometimes it is desirable to permit remote control of music level but keep music source selectable only on the host unit. In this 
case, internal jumper J1 on the sub-board for the Zone in use should be moved from ‘SW’ to ‘FR’. This will render the LM-2’s 
music source switch inoperative, and return source selection to the front panel. See the Z4

MK3

/Z8

MK3

 Installation and User 

Guide for full details and jumper locations.

46-120 and 46-120

MEDIA

:

These units only have a single Facility Port, for Zone 1. Thus the LM-2 can only be installed in Zone 1. (If the LM-2 needs to be 
added to a different Zone in an existing system, this restriction may be simply overcome by swapping outputs and renaming the 
Zones.)
Set the two 

REMOTE MUSIC CONTROL buttons (LEV and SRC) for ZONE 1 on the rear panel to REMOTE (in). The 

buttons are immediately below the 4 x 3-pin REMOTE CONTROL PANEL CONNECTORS. This will disable the host unit’s 
front panel music source and level controls for Zone 1.
Sometimes it is desirable to permit remote control of music level but keep music source selectable only on the host unit. In 
this case, set the 

SRC button for ZONE 1 back to FRONT PANEL (out). This will render the LM-2’s music source switch 

inoperative, and return source selection to the front panel. See the 46-120/46-120

MEDIA’

s Installation and User Guide for full 

details and jumper locations.

Connecting multiple LM-2s

Two or more LM-2s may be installed in the same Zone by employing the LINK connector on the lower rear PCB. The primary 

purpose of this feature is so that microphones and music sources may be connected into the audio system at different locations 
within a single Zone (typically one of large area or complex layout). 

LINK

LINK

OUTPUT

OUTPUT

LM-2

 

(UK version illustrated)

Connect to 

OUTPUT socket

Connect to 

OUTPUT socket

Connect to 

FACILITY PORT

Screened 

Cat 5 cable

Screened 

Cat 5 cable

Connect to 

LINK socket

Local inputs

When modules are “daisy-chained” together in this way, the audio signals from each module are summed together to produce 

a single mono feed to the host unit. Thus two (or more) microphones may be connected within a zone and either or both used 
as wished, with individual mic level controls at their respective modules.
An internal gating circuit on each module automatically “disconnects” any chained modules which are not in use, to minimise 

noise contribution. Should this the gate function not be required for any reason, it may be disabled by linking two solder pads 

on the lower PCB - see page 8. (Remove the lower PCB from the faceplate before attempting to make this link.)
This also applies to multiple music sources simultaneously connected (though the possibility of resulting cacophony makes this 

a less likely scenario!)

 


background image

LM-2 Installation Guide v1.0

8

LM-2 LOWER PCB

PHONOS

XLR

DISABLE

LINK

GATE

LINK THESE TWO PADS

NOTE: Users should be aware when using simultaneous microphone and/or music sources from multiple linked modules that 

the operation of the LM-2’s Priority function may become unpredictable, and if the function is enabled, one microphone may 

disable another, for example. We recommend that the Priority function is not used under these circumstances.

Remote controls

When modules are linked, only one may act as the remote control for each of the host unit’s background music functions: 
source and level. The MUSIC SOURCE and MUSIC LEVEL controls 

7

 and 

8

 (see “Faceplate Controls and Connections” on 

page 4) on all but one of the linked modules must be disabled. This is done by moving jumpers J1 and/or J3 on the upper 
PCB as required.

LM-2 UPPER PCB

J1

J3

J4

LOCATION OF JUMPERS

Link indicates default jumper setting

The default setting for J1 and J3 is LOCAL; this enables both the faceplate background music source and level controls. Set both 

jumpers to LINK to “pass” the remote control functions to the LM-2 connected at the LINK connected.
Note that the two functions – background music source selection and background music level – may be disabled individually, so 

that one LM-2 in a Zone could control the music source and another the music volume.

FUNCTION

LOCAL

LINK

J1

Source select

Local  LM-2  selects 
music source

Linked  LM-2  selects 
music source

J3

Level

Local  LM-2  sets 
music volume

Linked LM-2 sets music 
volume

Note that it is also possible to “daisy-chain” standard Cloud RL-1 and RSL-6 remote control plates to the LINK connector. 

This would be useful if additional background music control points were required in the Zone, but not additional system inputs. 
Please refer to the Technical Notes section at 

www.cloud.co.uk

 for further information on this topic.

 


background image

LM-2 Installation Guide v1.0

9

LM-2 Priority Operation

If the MIC PRIORITY button on the LM-2 faceplate is not pressed, mic and/or line signals connected at the module will be 

routed to the Zone to whose Facility Port the LM-2 is wired, and heard through the audio system at volumes which can be 
controlled from the MIC LEVEL and MUSIC LEVEL controls on the faceplate. These locally-connected signals will be mixed 

within the host unit with any background music currently selected for that zone.

Mic priority:

The LM-2’s Priority facility has two modes of operation, selected by jumpers on the upper rear PCB. The default mode operates 

thus: with MIC PRIORITY pressed, a signal at the microphone input will cause the line input signal connected at the same module 

to “duck” by 30 dB, giving the speaker priority over the music. The attack time (how quickly the music level drops when the mic 
is used) and release time (how quickly it recovers after the mic signal stops) are pre-set, and optimised for best audible results.
The priority control signal is also sent to the host unit, where it additionally “ducks” whichever Line Input is currently selected 
in the Zone. Thus the LM-2 mic input has priority over both local and global music sources.
It is important to note that any Priority functions set within the host unit – e.g., Line 6 Priority or Paging – will operate as 
normal. However, if Line 6 Priority is selected and active, the Line 6 source will still be ducked by the LM-2’s Mic Priority.

Full priority:

LM-2 UPPER PCB

J1

J3

J2

J4

LOCATION OF JUMPERS

LINK

LINK

Link indicates default jumper setting

LOCAL

LOCAL

LM-2 MIC

MIC MAX

If jumpers J2 and J4 are moved from their default settings to the alternative setting, Priority operation changes. When MIC 
PRIORITY is pressed, the module’s summed output is used to derive the priority control signal that is sent back to the host 

unit, and the signal is at the voltage required by the host unit to fully mute the background music.
The result is that a signal at 

either

 the LM-2’s mic input 

or 

line input will fully mute the selected Line Input at the host unit, and 

thus any source connected at the LM-2 will take full priority over the Zone’s background music.
As with the default mode, any priority functions set within the host unit itself will still operate normally, though if Line 6 priority 

is selected and active, the Line 6 source will be overridden by the LM-2 Priority.

MODE

J2

J4

PRIORITY 

SOURCE

BACKGROUND 

MUSIC

Mic 
Priority

MIC

MIC

LM-2 mic input

30 dB ducking

Full 
Priority

LM-2

MAX

Sum  of  LM-2  mic 
input and line input

Full muting

 


background image

LM-2 Installation Guide v1.0

10

Power considerations

The LM-2 is powered from the host unit’s FACILITY PORT via the Cat 5 connection. The LM-2 consumes 12 mA of current 

from the host unit’s power supply.
In the majority of installations, the host unit will have ample spare current capacity to power one or more LM-2s. However, 

installers should note that this may not be case in a very large system with multiple remote modules in several Zones. If there 
is any doubt about the power capability, please refer to the host unit’s Installation and User Guide where full details of   power 

supply ratings can be found.

Should you have any questions concerning the installation and connection of the LM-2, please visit 

www.cloud.co.uk/resources

where you will find additional technical information.

 


background image

LM-2 Installation Guide v1.0

11

 


background image

Cloud Electronics Limited

140 Staniforth Road

Sheffield S9 3HF

England

Tel: +44 (0)114 244 7051

Fax: +44 (0)114 242 5462

email: info@cloud.co.uk

web: www.cloud.co.uk

Cloud Electronics USA

2065 Sidewinder Drive, 

Suite 200, Park City, 

Utah 84060. 

United States of America.

Toll Free: 0855 810 0161

Web: www.cloudusa.pro 

E-mail: sales@cloudusa.pro