CX-A850 Amplifier 

Installation & User Guide

 V 4.0 

Cloud Electronics Limited 

140 Staniforth Road, Sheffield, S9 3HF England 

Tel +44 (0) 114 244 7051 

Fax +44 (0) 114 242 5462 

E-Mail: 

info@cloud.co.uk

 

Web site: http://www.cloud.co.uk

 

 


background image

 


background image

CX-A850: Installation and Operation Manual   

 

08-03-05 V4 

 
 

CX-A850 Amplifier 

Installation and operation manual 

 

Contents

 

 
 

 

Section

  

Page

 

 

Safety Notes .............................................................................. 2 

 

General Description ................................................................... 2 

 

Installation.................................................................................. 2 

 

Input Facilities ............................................................................ 2 

 

 5 

Input Routing Schematics .......................................................... 3 

 

Output Details ............................................................................ 4 

 

100V Line operation ................................................................... 4 

 

Bridged Mode Operation ............................................................ 4 

 

Status Indicators ........................................................................ 5 

 

10 

Power Supply Capacity .............................................................. 5 

 

11 

VCA Modules ............................................................................. 5 

 

12 

VCA Module Installation............................................................. 5 

 

13 

Remote Level Plate Connections ............................................... 6 

 

14 

Speaker Equalisation Modules................................................... 6 

 

15 

Equalisation Module Installation................................................. 7 

 

16 

Field Servicing ........................................................................... 7 

 

17 

General Specifications ............................................................... 7 

 

18 

Technical Specifications............................................................. 8 

 


background image

 

CX-A850: Installation and Operation Manual 

08-03-05 V4 

Safety Notes 

 

• 

Do not expose the unit to water or moisture 

• 

Do not expose the unit to naked flames. 

• 

Do not block or restrict any air vent 

• 

Do not operate the unit in ambient temperatures above 45

o

• 

Do not touch any part or terminal carrying the hazardous live symbol (    )  
while power is supplied to the unit. 

• 

Do not perform any internal adjustments unless you are qualified to do so and fully 
understand the hazards associated with mains operated equipment. 

• 

The unit has no user serviceable parts.  Refer any servicing to qualified service 
personnel. 

• 

If the moulded plug is cut off the lead for any reason, the discarded plug is a 
potential hazard and should be disposed of in a responsible manner.
 

For more detailed information refer to the rear of the manual. 

General  

 

The CX-A850 is an eight-channel power amplifier with a typical output of 50 watts per 
channel into a 4

 load. The unit features extremely low distortion and low noise together 

with a high slew rate. Full circuit protection is provided and the load is disconnected if the 
heat sink overheats or any DC is detected at the output. A five-second switch-on delay 
operates to avoid any switching thumps or other extraneous signals reaching the speaker 
system.  The CX-A850 also has Dynamic Clipping Protection (DCP) that will automatically 
reduce the signal level when the amplifier is driven into clipping thus limiting any clipping 
distortion to a low level. 
 
All eight input amplifiers are balanced and have 3-pin plug in screw terminal type input 
connectors with adjacent level controls, all mounted on the rear panel. Input signal routing 
switches are provided and allow the unit to operate in many configurations whilst retaining 
simple input connections. 

 

Installation 

 

The CX-A850 is suitable for mounting in a standard 19" equipment rack and occupies two 
units of rack space. Sufficient ventilation must be provided for the unit. The amplifier draws 
cool air through the front panel and exhausts through the side panels and care must be 
taken not to obstruct the airflow otherwise the unit may intermittently turn off due to the built-
in thermal protection. The unit is 320mm deep but a depth of 400mm should be allowed to 
clear the connectors. 

 

Input Facilities 

 

All eight inputs are balanced and use 3-pin plug-in screw terminal type connectors (3.5mm 
pitch).  All inputs have a level control adjacent to their respective connector.  Rear panel 
mounted switches provide input routing on channels 2 to 8 allowing a variety of 
configurations.  
In its default configuration, the unit operates as eight independent amplifiers.  Four stereo 
pairs, driven from one stereo source and eight channels driven from one mono source are 
also possible by suitably configuring the input routing switches. Schematic diagrams of the 
switching network in various configurations can be found on page 3. 

 
 

 


background image

CX-A850: Installation and Operation Manual   

 

08-03-05 V4 

5  Input Routing Diagrams 
 
 
 
 
 

8 independent mono amplifiers 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

8 mono outputs fed from 1 mono 

input 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4 stereo amplifier pairs fed from 1 

stereo input pair 

 
 
 
 
 
 
 

Fig 1 

Fig 2 

Fig 3 

 


background image

 

CX-A850: Installation and Operation Manual 

08-03-05 V4 

Output Details 

Eight 2-pole plug-in screw terminal type connectors (5mm pitch) are provided on the rear 
panel for the eight speaker outputs; these can accommodate flexible leads up to 2.50mm².  
Do not make any connections to the unit with the power cable attached. It is good practice to 
distance the output wiring from the input wiring and keep the speaker wires twisted until they 
are terminated to reduce any cross-talk to a minimum level. 

 

100V Line operation

  

    CXL-40T Wired to Channel 8

 

An optional single-channel externally 
mounted 40W 70V/100V-line 
transformer module  (CXL-40T) is 
available for the CX-A850.  The 
installer can select 70 or 100V 
operation by wiring the speaker 
network to the 70V or 100V output 
terminals on the CXL-40T.  When a 
CXL-40T is installed to a zone, the 
65Hz high pass filter for that zone 
must be switched on using the 
appropriate jumper/s.  The 
instructions below detail the procedure you must follow to activate the appropriate filter 

 

1)  Turn the power off & remove the mains lead.    
2)  Remove the top panel from the unit. 
3)  Turn the relevant 65Hz high pass filter ‘on’ by moving the relevant jumpers to the ‘ON’ 

position (see list below). 

 

J1 = Channel 1         J5 = Channel 5 
J2 = Channel 2         J6 = Channel 6 
J3 = Channel 3         J7 = Channel 7 
J4 = Channel 4         J8 = Channel 8 

 

Jumpers J1-8 are located from left to right on the PCB, 57mm in from the rear panel. 

4)  Replace the top panel.  

 

If a filter is not switched on, operation at high input levels and low frequencies may result in 
the transformer saturating and the amplifier’s VI and clip limiting operating. 
A 2U 19" rack panel (CXL-800) is also available which can accommodate up to 8 CXL-40T 
transformer modules. 

 

Bridged Mode Operation 

The unit can be operated in Bridged Mode using any two channels (see Fig 5).  The two 
amplifiers that are to be bridged must have the same signal input fed to each of them and be 
out of phase with each other.  The input level controls of the two channels should both to be 
set to the fully clockwise position. 

 

Wiring Channels 7 and 8 in Bridged Mode 

 

Fig 5 

R

Black

W

P

Blue

100V

0V

SPEAKER OUTPUTS

OUTPUT RATING 50W / 4OHMS

MIN LOAD 4 OHMS

0V

CH1

0V

CH2

0V

CH3

0V

CH4

0V

CH5

0V

CH6

0V

CH7

0V

CH8

Fig 4 

 


background image

CX-A850: Installation and Operation Manual   

 

08-03-05 V4 

The output load should then be connected between the two positive (HOT) outputs of the 
relevant channels (no connection to common).  You must ensure that the positive wire is 
connected to the "first channel" output and the negative wire is connected to the "second 
channel" output (see fig 5). 

Status Indicators 

The front panel of the CX-A850 has an array of LED’s that indicate the status of all eight 
channels (see Fig 6).  

 

The lower green ‘signal’ LED illuminates when a signal is detected, the yellow 'peak' LED will 
illuminate when the amplifier’s DCP is operating and the top red ‘protect’ LED indicates that 
the protection relay has disconnected the load. Please note that it is normal for all four red 
LED's to illuminate for approximately five seconds when the unit is switched on, indicating 
operation of the switch-on delay circuitry. The green ‘power’ LED at the bottom right of the 
front panel illuminates when the power is switched on. 

 

10 

Power Supply Capacity 

The CX-A850 has up to 100mA of available current for use with additional modules.  
Exceeding this limit will cause temporary power supply failure.  Use the table below to verify 
your proposed system does not exceed this limit. 

 

Module Name 

Current Required 

BOSE® EQ cards: M8, M32, MA12, 402, 502A, 802, MB4, MB24, 
502B, 502BEX 

12mA 

BOSE® EQ cards: LT3202, LT4402, LT9402, LT9702 

17mA 

BOSE® EQ card: M16 

24mA 

VCA-5 

9mA 

11 

VCA Modules 

A single channel VCA module ‘VCA-5’ is available as a plug-in option for 
each of the eight channels.  When a VCA-5 is installed to a channel it 
allows the channel to be controlled remotely with the optional RL-1 
remote plate.   
The circuitry uses the industry standard 'Thats 2150A' VCA providing 
very low distortion and up to 90dB attenuation. The VCA module can be 
wired to provide muting by using an auxiliary relay connected to a fire 
alarm control panel. Contact our technical department for further details. 

 

12 

VCA Module Installation 

1.  Turn the power off and remove the mains cable                             
2.  Remove the top panel

 

 

3.  Select the required PCB mounted VCA connector and 

remove its jumper (see list below & Fig 8) 

CON1 = Channel 1  

CON5 = Channel 5 

CON2 = Channel 2  

CON6 = Channel 6 

CON3 = Channel 3  

CON7 = Channel 7 

CON4 = Channel 4  

CON8 = Channel 8 

4.  Unscrew the relevant blanking plate from the rear of the unit 

& retain the screw.   

 

Fig 8 

Fig 6 

Fig 7 

 


background image

 

CX-A850: Installation and Operation Manual 

08-03-05 V4 

5.  Adjacent to the connector there is an M3 fixing screw remove & retain this screw then fit a 35mm 

M3 hex spacer (supplied) in its place.

 

 

6.  Push the 10-way VCA plug onto the PCB connector, aligned so the cable enters it from the rear of 

the chassis (See Fig 9) check there is contact with all 10 pins. 

7.  Position the VCA modules 3-pin socket through the rear panel cut-out and secure using M3 screws 

(both removed earlier)    

 

 

 

VCA Modules Installed to Channel 1&2 

8.  Replace the top panel.   

              Side View of VCA Ribbon Cable

 

             
 

 

 
13 

Remote Level Plate Connections 

The RL-1 is a remote control plate that allows the level of a specific channel to be remotely 
controlled (in conjunction with the VCA-5).  The RL-1 is compatible with UK domestic 
electrical accessories and can be mounted onto a standard British flush or surface mounted 
25mm deep back box.  

 

As Fig 11 shows, the RL-1 is to be connected to a CX-A850 remote connector with a two-
core cable that has an overall screen.  It is possible to connect a single remote control 
module to control more than one channel simultaneously (Fig 11 right).  As more channels 
are linked the law of the control will be compromised resulting in an uneven control of 
volume; this has proved to be of little consequence operationally. 

 

14 

Speaker Equalisation Modules 

Each channel of the CX-A850 can have a speaker

 

equalisation module installed so that its 

output will be compensated correctly for a wide range of speakers.   
 
Available Equalisation Modules: 
- Bose

®

 Speaker models: 

M8, M16, M32, MA12, 402, 502A, 502B, 502BEX, 802, MB4, MB24, 

LT3202, LT4402, LT9402, LT9702

 

 

Fig 9 

Fig 11 

Fig 10 

 


background image

CX-A850: Installation and Operation Manual   

 

08-03-05 V4 

15 

Equalisation Module Installation 

1.  Turn the power off and remove the mains lead.    
2.  Remove the top panel from the unit.   

Channel  7&8 PCB Connector Locations 

3.  Select the required PCB connector (see 

Fig 12 adjacent) that you wish to install 
the equalisation module to and remove 
the jumper from it. 

 

CON12 & J9   = Channel 1                    

 

  CON13 & J10 = Channel 2 

 

CON14 & J11 = Channel 3 

 

CON15 & J12 = Channel 4 

 

CON16 & J13 = Channel 5 

 

CON17 & J14 = Channel 6 

 

CON18 & J15 = Channel 7 

 

CON19 & J16 = Channel 8 

4.  Configure the relevant 65Hz filter to ‘ON’ and connect a CXL-40T 100V line transformer 

(see section 7) 

5.  Fit the EQ card to the connector such that the EQ card is perpendicular to the main board 
6.  Push down on the EQ card until it locates with a click. 
7.  Replace the top panel. 

 

NOTE: Before installing active modules, check section 10 for details of the power supply on 
the CX-A850.  Each channel of the CX-A850 can have both a VCA-5 module and a speaker 
EQ card installed at the same time. 

 

16 

Field Servicing 

The CX-A850 is ruggedly built and uses proven reliable circuitry. It requires no more than the 
occasional removal of any dust that may have built up inside the unit because of the forced 
cooling.  

 

17 

General Specifications 

 

Inputs 

Balanced via 3-pin plug-in screw terminal type connectors 

Outputs 

2-pin plug-in screw terminal type connectors for flexible cables up to 2.5mm² 

Protection 

VI limiting, DC offset, Thermal, Switch-on Delay & Dynamic Clipping 
Protection 

Status Indicators 

LED indicators on each channel for Signal, Peak &Protect 

Cooling 

Force cooled using variable speed DC fan 

Dimensions 

482.6mm x 88.0mm (2U) x 300.0mm deep (+ connectors) 

Weight 

8.8kgs 

 

Fig 12 

 


background image

 

CX-A850: Installation and Operation Manual 

08-03-05 V4 

18 

Technical Specifications 

 

Number of Channels Driven 

Rated Output 4 Ohm load(s) 

Rated Output 8 Ohm load(s) 

62W 

36W 

58W 

34W 

54W 

32W 

50W 

30W 

47W 

29W 

44W 

28W 

41W 

27W 

38W 

26W 

 

Bridged Output 

100W nominal into 8 Ohm load, minimum load 8 Ohms 

Frequency Response 

+0dB –0.5dB 10Hz to 20kHz, switchable high pass filter –3dB 
@65Hz 

THD+N 

0.007%, typical, @1kHz,  60W into 4 Ohms, one channel driven, 
measurement BW 22Hz to 80kHz 

VCA Module THD+N 

<0.03% 1kHz, measurement BW 22Hz to 80kHz 
-85dB (relative to 60W) @1kHz with 4 Ohm load 

-82dB (relative to 60W) @10kHz with 4 Ohm load 

-90dB (relative to 30W) @1kHz with 8 Ohm load 

Crosstalk 
Typical, between adjacent 
channels 

-90dB (relative to 30W) @10kHz with 8 Ohm load 

Input Sensitivity 

0dBu (775mV) 

Input Impedance 

10k  balanced / 5k  unbalanced 

Noise 

<96dB rms below rated output, unweighted, measurement BW 
22Hz to 22kHz 

Power Input 

230V ±5% (115V ±5% available) 

Fuse rating 

230V – T4A H     115V – T8A H 

Fuse type 

20mm x 5mm class 3T 250V 

 

 
 
 
 
 
 
 
 
 
 

 

 
This product conforms to the following European EMC Standards: 

 

BS EN 55103-1:1997 
BS EN 55103-2:1997 

 

This product has been tested for use in commercial and light industrial environments.  If the equipment 
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to 
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded. 

 

The product conforms to the following European electrical safety standard. 

 

BS EN 60065:1998 

 

 

 


background image

CX-A850: Installation and Operation Manual   

 

08-03-05 V4 

Safety Considerations and Information 

 

The unit must be earthed. Ensure that the mains power supply provides an effective earth 

connection using a three-wire termination. 

 

When the mains switch is in the off ‘O’ position the live and neutral conductors of the mains 

transformer are disconnected, however some parts of the product will still remain connected to 

the live and neutral mains conductors 

 

CAUTION – Installation 

 

Do not expose the unit to water or moisture 

Do not expose the unit to naked flames. 

Do not place liquid filled containers on or around the unit 

Do not block or restrict any air vent 

Do not operate the unit in ambient temperatures above 45

o

 

CAUTION – Hazardous Live 

 

Do not touch any part or terminal carrying the hazardous live symbol (    ) while power is 

supplied to the unit. 

 Terminals to which the hazardous live symbol refers require installation by a qualified person. 

 

CAUTION - Mains Fuse 

 

Replace the mains fuse only with the same type and rating as marked on the rear panel.  The 

fuse body size is 20mm x 5mm. 

 

CAUTION – Servicing 

 

The unit contains no user serviceable parts.  Refer servicing to qualified service personnel. Do 

not perform servicing unless you are qualified to do so. 

Disconnect the power cable from the unit before removing the top panel and do not make any 

internal adjustments with the unit switched on. 

Only reassemble the unit using bolts/screws identical to the original parts 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Bose  is a registered trademark of The Bose Corporation 

 

In the interest of continuing improvements Cloud Electronics Limited reserves the right to alter 

specifications without prior notice. 

 

Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England 