Installation Instructions 

Close Talk Conference System is very easy to install by following a few guidelines: 
 

1.

 

Start with unpacking and checking that all required products have been delivered 
 

2.

 

Transceiver Units 
The single most important installation stage is the mounting of the ceiling Transceiver Units. Make sure 
to follow the placement drawing/instruction carefully. The actual mounting method for each 
Transceiver type is self-explanatory so it will not be shown here. 
 
Important: To avoid ground loops the Transceiver case must not be connected, directly or indirectly, to 
safety ground. 
 

3.

 

Cables 
If the cables are supplied by Close Talk simply unpack them from the packaging. Place the cables free 
from strong disturbance sources. Do not bend the cable harder than a 5cm/2" radius or the cable can be 
damaged. 
 
The cables should not be cut or shortened since the cable lengths are carefully planned and critical for a 
working system. Any cable slack should be collected in a figure 8 to avoid magnetic pickup 
disturbances, do not collect cable slack in a coil manner. 
 
If custom made cables are used be sure to make them in the correct lengths and also test them using a 
cable testing tool before connecting to the system units or product damage can occur. Damaged 
products due to faulty cables are not covered by any warranty. 
 
Note! Close Talk Conference System uses a proprietary signal system, not Ethernet! Do not connect 
Close Talk products to anything other than Close Talk products or product damage may occur. 
 

4.

 

Split Boxes 
Split Boxes are a convenient installation help by reducing cabling work. Be sure to mount the Split Box 
and its power supply in a cool place, not exceeding +40C/104F. 
 
Important: To avoid ground loops the Split Box case must not be connected, directly or indirectly, to 
safety ground. 
 

5.

 

Central Unit 
The Central Unit can be mounted freely within cable length limitations. Place it in a cool place, not 
exceeding +40C/104F. Study the Central Unit User Manual for instructions on how to operated the unit 
and later the Quick Start Guide (see point 8). 

6.

 

Battery Chargers 
There are two types of battery chargers, the 5 unit cord charger and the Charger Trolley. The cord 
charger is very easy to use, simply plug in to charge, charging is automatic. Make sure the charger and 
its power supply is not covered to prevent overheating. 
 
The Charger Trolley comes with its own assembly and operations manual included with the trolley 
frame. 
 

7.

 

Delegate Units 
The Delegate Units are delivered without microphone and with or without battery. If the unit is 
delivered without battery, start by mounting the battery. Warning! Do not reverse the battery poles or 
the unit will require servicing! 
 
Connect the desired microphone and secure it firmly using the locking knut. The locking knut also 
contains an extra Allen/Hex key locking screw to prevent theft of the microphone, use the supplied tool 
to secure it if desired. 
 
The Delegate Unit is then ready to use. Note! The battery is delivered factory charged to about 30% 
capacity, please charge the battery fully as soon as possible.                                               Turn Over... 

 


background image

 

CONFERENCE SYSTEM™

 

Close Talk Conference System™ c/o Apodosis AB, Landsvägen 51, S-172 65, Sundbyberg, SWEDEN 
Tel: +46-(0)8-7645227, VAT#: SE556842007801  

www.closetalk.se

        

sales@closetalk.se

         

www.apodosis.se

         

sales@apodosis.se

 

8.

 

Quick Start Guide 
After the hardware is installed it is time to power up the system. Turn on the Central Unit and do a 
quick test by activating Delegate Unit microphones around the room. The microphones should activate 
without problems within the room operating area, if not check cabling to the Transceivers and/or Split 
Boxes. 
 
Once the system seems to be operating it is recommended to do a system transmission level test. The 
test is done by using the Close Talk Install PC software as described in the Quick Start Guide
 
Once the system is operational it is time to program the Central Unit according to the customer's 
wishes. The Quick Start Guide contains a detailed step by step guide to do a full setup of the Central 
Unit, please follow this guide, preferably together with the customer. 
 

9.

 

Close Talk Control PC software 
The Close Talk Control PC software is an advanced conference management and control tool. Please 
refer to the Close Talk Control User Manual for information about installation and usage. 

10.

 

Maintenance 
If properly maintained a Close Talk Conference System will provide many years of service. The Quick 
Start Guide
 contains important maintenance information. 

 
 