AVM 321S, 322S: Valve actuator

How energy efficiency is improved

Automatic adaptation to valve, optimal operator convenience, precision activation and high energy ef-
ficiency with minimal operating noise

Features

F

or actuation of 2- and 3-way valves

• For controllers with constant output (0...10 V / 4...20 mA) or switching output (2-point or 3-point con-

trol)

• BLDC motor (brushless DC) with SUT (Superior Universal Technology) electronic control unit of the

third generation and electronic load-dependent cut-off

• Automatic detection of applied control signal (continuous or switching), operating display with bi-col-

our LED

• Automatic adaptation to the stroke of the valve, between 10 and 20 mm
• Low operating noise
• With the built-in absolute distance measurement system, the position is always maintained in the

case of power failure

• The direction of operation, characteristic (linear/equal percentage), positioning time and control sig-

nal (voltage/current) can be adjusted via coding switches

• Integrated forced operation can be set via coding switches (with selectable direction of operation)
• Easy re-initialisation using a coding switch
• Crank handle for external manual adjustment with motor cut-off
• Simple assembly with valve; spindle is automatically connected after control voltage is applied
• Numerous adapters enable the unit to be fitted onto non-Clorius valves
• Electrical parallel operation of five actuators
• Parameterisation option via the BUS interface
• Three-piece housing made of flame-retardant yellow/black plastic and seals with type of protection

IP54

• Maintenance-free gearbox made of plastic; threaded spindle and gearbox base-plates made of

 

steel

• Patented drive-valve coupling
• Mounting column made of aluminium
• Fixing bracket made of cast light alloy for valve fitting with 20 mm stroke and made of plastic for

valve fitting with 10 mm stroke

• Electrical connections (max. 1.5 mm²) with screw terminals
• Two break-out cable inlets for metric cable glands made of plastic M20 × 1.5
• Fitting position vertically upright to horizontal, not suspended
• Nominal thrust 1000 N

2) 

Technical data

Power supply

Power supply 24 V~

±20%, 50...60 Hz

Power supply 24 V=

–10...20%

Power supply 230 V~

±15%

Power consumption

< 1.7 W, < 3.5 VA
(at nominal voltage, with movement)

Parameters

Nominal force

3)

1000 N

Operating noise

4)

< 30 dB (A) at nominal force

Response time

> 200 ms

1)

CSA-certified actuators on request

2)

Actuating power 1000 N under nominal conditions (24 V, 25 °C ambient temperature, 50 Hz). With boundary
conditions (19.2 V~ / 28.8 V~ / 21.6 V= / 28.8 V=, -10 °C / 55 °C, 60 Hz) and positioning time, the actuating/
ten-sile force is minimised to 800 N

3)

Noise level with the slowest positioning time, measuring distance 1m

Product data sheet

99.70.06-C

3.1

1/8

AVM32*S

www.cloriuscontrols.com

 


background image

Temperature of medium

5)

0...100 °C

Nominal voltage

24 V~/=

Characteristic

Linear/equal percentage

Control signal y

6)

0...10 V, R

i

 ≥ 50 kΩ 

4...20 mA, R

i

 ≤ 50 Ω

Positional feedback y

0

0...10 V, load ≥ 5kΩ

Starting point U

0

0 or 10 V

Starting point I

0

4 or 20 mA

Control span ΔU

10 V

Control span ΔI

16 mA

Hysteresis X

sh

160 mV
0.22 mA

Ambient conditions

Operating temperature

-10...55 °C

Storage and transport temperature

-40...80 °C

Humidity without condensation

5...85 % rh

Standards and directives

Type of protection

IP 54 (EN 60529)

Protection class

III (EN 60730-1), EN 60730-2-14

CE conformity according to

EMC Directive 2004/108/EC

EN 610000-6-1, EN 610000-6-2,
EN 610000-6-3, EN 610000-6-4

Low-voltage directive 2006/95/EC

EN 60730-1, EN 60730-2-14
(AVM32*F110 and F120)

Over-voltage categories

III

Degree of contamination

II

Max. altitude

2000 m

Machine directive 2006/42/EC 
(according to appendix IIB)

EN ISO 12100

Overview of types

Type

Nominal voltage

Positioning time
(s/mm)

Nominal stroke

Dimensions W x
H x D

Weight

AVM321S

24 V~/=

12 (4)

10 mm

160 × 187 × 88

1.5

AVM322S

24 V~/=

6 (4)

20 mm

160 × 241 × 88

1.6

5)

At media temperature > 100 °C appropriate accessory must be used (temperature adapter); at media tempera-
ture < 0 °C appropriate accessory must be used (stuffing box heater)

6)

Positioner: also for 2- or 3-point, depending on type of connection

Product data sheet

99.70.06-C

2/8

3.1

Accessories 

Type 

Description 

1-0152285

Temperature adaptor for media temperature > 100 °C … 240 °C 

1-0152313

*

4...20 mA feedback module 

1-0152315

*

Constant power supply module for 85…265Vac 50/60Hz 

1-0152665

Adjustable valve adaptor for for AVM322 and Clorius Controls valves  

up to 20 mm stroke

1-0152675

Adjustable v

alve adaptor for for AVM321 and Clorius Controls valves 

up to 10mm stroke

Cable glands M20×1.5 

www.cloriuscontrols.com

 


background image

Description of operation

Depending on the type of connection (see connection diagram), the actuator can be used as a contin-
uous (0...10 V or 4...20 mA), 2-point (OPEN/CLOSE) or a 3-point actuator (OPEN/STOP/CLOSE).
The positioning time of the actuator can be set with the S1 switches according to the respective re-
quirements. Using switch S2, the direction of operation can be changed.
In the end positions (valve limit stop or when the maximum stroke is reached) or upon overload, the
electronic motor cut-off (no limit switch) responds and turns off the motor.
The external crank handle enables manual positional setting. After the crank handle is folded back,
the actuator moves to the target position again (without initialisation). When the crank handle is folded
out, the actuator remains in this position.

Intended use

This product is only suitable for the purpose intended by the manufacturer, as described in the “De-
scription of operation” section.
All related product regulations must also be adhered to. Changing or converting the product is not ad-
missible.

Engineering and fitting notes

The concept of a brushless DC motor/electronics ensures electrical parallel operation of up to five ac-
tuators of the same type.
The valve is mounted directly on the actuator and fixed with screws (no further adjustments are re-
quired). The actuator is connected with the valve spindle automatically. As delivered ex works, the ac-
tuator spindle is in the middle position.
As delivered ex works, the actuator spindle is in the middle position.
Condensate, dripping water, etc. must be prevented from entering the actuator along the valve spin-
dle.
The housing contains two break-out cable inlets for two metric plastic cable glands M20×1.5, which
are broken out automatically when the cable inlet is screwed in.
If the cable resistance is > 1.5 Ω, the ground should be separated from the power supply and the sig-
nal if possible.
The cross-section of the power cable must be selected based on the cable length and the number of
actuators. With five parallel actuators and a cable length of 50 m, a cable cross-section of 1.5 mm

2

and a line resistance of > 1.5 Ω must be used (power consumption of the actuator × 5).
According to building installation regulations, the lines must be protected from overload or short cir-
cuit.

)

Note for UL and CSA applications:
In the United States, the installed lines and cross-sections which are to be connected by the customer
must comply with the requirements of NFPA70 (NEC), and in Canada they must comply with the require-
ments of the standard C22.1-12 (CE Code).

The coding switches and the SLC interface for CASE Drives are accessible via an opening in the con-
nection area of the actuator. Conversion and operation is possible while the actuator is energised.

Product data sheet

99.70.06-C

3.1

3/8

www.cloriuscontrols.com

 


background image

)

Note:
The actuators are not suitable for use

in potentially explosive environments,

Specific standards such as IEC/EN 61508, IEC/EN 61511, EN ISO13849 and the like have not been 

tak-en into account.

Local requirements regarding installation, usage, access, access rights, accident prevention, safety, dis-

mantling and disposal must be taken into account.

The housing must not be opened. 

Outdoor installation

In case of installation outside buildings, the devices must also be protected from the weather.

Additional information

Fitting instructions

P100014079 B

Declaration on materials and the environment
Declaration of incorporation

Power consumption at nominal voltage

Type

Positioning time (s/mm)

Status

Active power P(W)

Apparent power S (VA)

AVM321S

12 / (4)

Operation

< 1.7

< 3.5

Standstill

< 0.45

Sizing

≥ 4.5

AVM322S

6 / (4)

Operation

< 1.7

< 3.5

Standstill

< 0.45

Sizing

≥ 4.5

Connection as 2-point valve actuator (24 V)

The OPEN/CLOSE activation is via two wires.
The actuator is connected to a permanent voltage via terminal MM and terminal 01.
When voltage (24 V) is applied to terminal 02, the actuator spindle extends into the end position.
After the voltage is switched off at terminal 02, the actuator automatically retracts into the base posi-
tion.
Terminal 03 may not be connected or touch other contacts. We recommend that you insulate these.

Connection as 3-point valve actuator (24 V)

If voltage is applied to terminals MM and 01 (or 02), the valve can be moved to any position.
If voltage is applied to terminals MM and 01, the actuator spindle retracts.
If the electrical circuit is closed on terminal MM and 02, the actuator spindle extends.
If there is no voltage on terminals 01 and 02, the actuator remains in the respective position until volt-
age is applied.
Terminal 03 may not be connected or touch other contacts. We recommend that you insulate these.

Connection to a control voltage (0...10 V or 4...20 mA)

The built-in positioner controls the actuator depending on controller’s output signal y. A voltage signal
(0...10 V) at terminal 03 serves as the control signal. Coding switch S4 can be used to switch to a
current input (4...20 mA). If there is voltage on terminals MM/01 and a rising positioning signal, the
actuator spindle extends. The direction of operation can be reversed with coding switch S2.
The starting point and control span are fixed. For setting partial ranges (only for voltage input), a split-
range unit is available as an accessory (see split-range unit function).
After the connection of the power supply and the initialisation, the actuator moves to every valve
stroke between 0% and 100%, depending on the control signal. Thanks to the electronics and the ab-
solute distance measurement system, no stroke is lost, and the actuator does not require periodic re-
initialisation.
If the control signal 0...10 V is interrupted in the direction of operation 1, the actuator spindle retracts
completely.
If the control signal 0...10 V is interrupted in the direction of operation 2, the actuator spindle extends
completely. This is true if the forced operation is switched off. (Coding switch S5 OFF)

Product data sheet

99.70.06-C

4/8

3.1

www.cloriuscontrols.com

 


background image

With coding switch S3, the characteristic of the valve/actuator combination can be adjusted. An
equal-percentage characteristic can only be generated when the actuator is used as a continuous ac-
tuator.

Initialisation and feedback signal

The actuator initialises itself automatically when it is connected as a continuous actuator (not in 2-/3-
point mode).
When a voltage is applied to the actuator for the first time, the actuator first moves to the first and
then to the second valve limit stop, or to the internal actuator stop. The two values are recorded and
stored by the absolute distance measurement system. The control signal and the feedback are adap-
ted to this effective stroke.
After initialisation, the actuator goes to every valve stroke between 0% and 100%, depending on the
control voltage.
In case of a power failure or the removal of the power supply, no re-initialisation needs to be carried
out. The values remain saved.
If the initialisation is interrupted, the initialisation is started again when the voltage is re-applied.
You trigger a re-initialisation by switching coding switch S8 from OFF to ON or vice versa.
When the process is triggered, the LED flashes green.
During initialisation, the feedback signal is inactive or equal to the value “0”. The initialisation is car-
ried out with the shortest positioning time. The re-initialisation is only valid when the whole process is
complete.
If a stroke change is carried out, a re-initialisation must be triggered so that the new stroke can be
adapted.
If the valve actuator detects jamming, it reports this by setting the feedback signal to 0 V after approx.
90 s. During this time, the actuator continues to try to overcome the jamming. If the jamming can be
overcome, the normal control function is activated again and the feedback signal is restored.
With 2-point or 3-point control without a feedback signal, no initialisation is performed.
Continuous control can also be implemented with a 230 V power supply with the external accessory
0500570003 “230 V module”. You must ensure that the neutral wire of the controller is connected to
the control voltage. The neutral wire of the power supply may only be used for the 230 V module.

B1

2671

Forced operation (in continuous mode)

Forced operation is activated via coding switch S5.
To use this function, an external on/off controller must be attached to terminal 6. The on/off controller
functions as normally-closed contacts.
If the on/off controller opens the electrical circuit, the actuator spindle moves to the end position de-
fined by coding switch S6.
Forced operation can be used only in continuous mode.

2-/3-point operation using the reset signal

If terminal 6 is continuously connected to the power and coding switch S5 is set to OFF, the feedback
signal 0...10V can be used.
When this function is used, the actuator automatically performs an initialisation during commissioning.

Split-range module, accessory 0500420002

Starting point U0 and control span U can be set with the potentiometer. In this way, several control
units can be operated in sequence or cascade by the control signal of the controller. The input signal
(partial range) is amplified into an output signal of 0...10V.

CASE Drives PC tool, accessory 0510220001

CASE Drives allows you to set and read the actuator parameters on site. The connection is via a seri-
al port on the PC (laptop) and a socket on the actuator. The set consists of: The software including
installation and operating instructions, fitting instructions, connection plug, cable (1.2 m long) and in-

Product data sheet

99.70.06-C

3.1

5/8

www.cloriuscontrols.com

 


background image

terface converter for the PC. The application is designed for commissioning and service engineers as
well as experienced operators.

Feedback signal converters, accessory 

1-0152313*

With the feedback signal converter accessory (drawing no. 0500420002), the output signal yo is 
converted from a voltage signal 0...10 V into a current signal 4...20 mA.

Coding switch

e

d  

g

n

u

ll

e

t

s

r

e

tl

a

h

c

S

rf 

u

d

 

n

o

it

i

s

o

P

r

u

e

t

a

t

u

m

m

o

c

n

e  

n

o

it

i

s

o

p

 

h

c

ti

w

S

ti 

e

n

o

i

z

i

s

o

P

e

r

o

tt

u

r

r

e

t

n

i‘

ll

e

d

s

e  

r

o

t

p

u

r

r

e

t

n

l

e

d

 

n

ó

i

c

i

s

o

P

v

s  

e

g

ä

lr

a

t

y

r

B

l

n  

d

n

a

t

s

r

a

a

l

e

k

a

h

c

S

 

 

 

 

 

 

 

 

e

d  

n

n

i

s

k

ri

W

rf 

n

o

it

c

a

d

 

s

n

e

S

n

e  

f

o

 

n

o

it

c

e

ri

D

n

o

it

a

r

e

p

o

ti 

e

n

o

i

z

e

ri

D

e

n

o

i

z

a

‘l

l

e

d

s

e  

e

d

 

o

d

it

n

e

S

o

d

n

a

m

v

s  

g

n

i

n

t

k

ir

tf

ir

D

l

n  

g

n

it

h

c

ir

s

g

n

i

k

r

e

W

e

d  

*

b

e

ir

t

n

A

 

e

i

n

il

n

n

e

K

rf 

b

r

u

o

C

u

d

 

e

u

q

it

s

ir

é

t

c

a

r

a

c

r

u

e

t

o

m

o

v

r

e

s

n

e  

r

o

t

a

u

t

c

A

c

it

s

ir

e

t

c

a

r

a

h

c

ti 

 

a

c

it

s

ir

e

tt

a

r

a

c

 

a

v

r

u

C

e

r

o

t

a

u

tt

a

s

e  

 

a

c

it

s

ír

e

t

c

a

r

a

c

 

a

v

r

u

C

r

o

t

o

m

 l

e

d

v

s  

g

n

i

n

v

ir

d

 ,

a

v

r

u

K

l

n  

 

k

e

it

s

ir

e

t

k

a

r

a

K

g

n

i

v

ji

r

d

n

a

a

e

d  

*l

a

n

g

i

s

ll

e

t

S

rf 

e

d

 l

a

n

g

i

S

i

s

o

p  

t

n

e

m

e

n

n

o

it

n

e  

l

a

n

g

i

s

 

g

n

i

n

o

it

i

s

o

P

ti 

 i

d

 

e

l

a

n

g

e

S

e

n

o

i

z

a

l

o

g

e

r

s

e  

o

d

n

a

m

 

e

d

 l

a

ñ

e

S

v

s  

l

a

n

g

i

s

r

y

t

S

l

n  

l

a

a

n

g

i

s

r

u

u

t

S

e

d  

*

g

n

u

r

e

u

e

t

s

s

g

n

a

w

Z

rf 

e

é

c

r

o

e

d

n

a

m

m

o

C

n

e  

n

o

it

a

r

e

p

o

 

d

e

c

r

o

F

ti 

o

t

a

z

r

o

o

d

n

a

m

o

C

s

e  

 

o

d

n

a

M

o

c

i

m

ó

r

d

o

m

s

e

d

v

s  

li

t

n

e

v

 

d

r

y

t

s

s

g

n

å

v

T

l

n  

g

n

ir

u

t

s

e

b

g

n

a

w

D

e

d  

-

s

g

n

a

w

Z

 t

k

n

u

p

s

s

e

il

h

c

S

*

g

n

u

r

e

u

e

t

s

rf 

 

a

e

d

 

e

r

u

t

e

m

r

e

e

d

 t

n

i

o

P

e

é

c

r

o

e

d

n

a

m

m

o

c

n

e  

 

d

e

c

r

o

r

o

t

n

i

o

p

 

g

n

i

s

o

l

C

n

o

it

a

r

e

p

o

ti 

 i

d

 

o

t

n

u

p

 

o

t

a

z

r

o

o

d

n

a

m

o

C

o

i

g

g

a

c

c

o

l

b

s

e  

 

o

d

n

a

m

 l

e

d

 

e

r

r

e

i

c

 

e

d

 

o

t

n

u

P

o

c

i

m

ó

r

d

o

m

s

e

d

v

s  

 

d

r

y

t

s

s

g

n

å

v

,t

k

n

u

p

s

g

n

i

n

g

n

ä

t

S

li

t

n

e

v

l

n  

g

n

ir

u

t

s

e

b

g

n

a

w

d

 t

n

u

p

ti

u

l

S

m

m

/

s

 

2

1

 :

1

2

3

M

V

A

m

m

/

s

 

6

 :

2

2

3

M

V

A

100%

0%

Signal

lin

V

 

0

1

..

.

0

 

C

D

prio.

off

m

m

/

s

 

4

 :

1

2

3

M

V

A

m

m

/

s

 

4

 :

2

2

3

M

V

A

100%

0%

Signal

stroke

= %

INV

de

 

*G

ilt n

ur 

r s

te

tig

 M

od

us

fr
*S

‘a

pp

liq

ue

un

iq

ue

m

en

ta

um

od

e d

e r

ég

ula

tio

n c

on

tin

ue

en

*A

pp

lie

s

fo

rc

on

tin

uo

us

m

od

e

on

ly

it
*V

ale

so

lo

pe

rm

od

o

„c

on

tin

uo

es

*S

e

ap

lic

a

lo

pa

ra

m

od

o

co

ntin

uo

sv
*G

älle

re

nd

as

tfö

rk

on

tin

ue

rlig

re

gle

rin

g

nl

*G

eld

tu

its

lu

ite

nd

vo

or

co

ntin

u

m

od

us

A

m

 

0

2

..

.

4

prio.

on

e

d  

ti

e

z

ll

e

t

S

rf 

e

d

 

s

p

m

e

T

 

t

n

e

m

e

n

n

o

it

i

s

o

p

n

e  

e

m

it

 

g

n

i

n

o

it

i

s

o

p

ti 

a

r

v

o

n

a

m

 i

d

 

o

p

m

e

t

s

e  

e

t

s

u

j

a

 

e

d

 

o

p

m

e

it

v

s  

d

it

ll

ä

t

s

l

n  

d

ji

tl

e

t

s

LED

LED

Description

Flashes green (T1s) Valve adapting, initialisation
Flashes green (T3s) Position reached
Lights up green

Actuator spindle moves IN/OUT

Flashes orange

Manual adjustment activated

Flashes red

Actuator jammed, actuator at end stop

Lights up red

Incorrect configuration of forced operation, undervoltage, insufficiently adapted stroke

Disposal

When disposing of the product, observe the currently applicable local laws.
More information on materials can be found in the Declaration on materials and the environment for
this product.

Product data sheet

99.70.06-C

6/8

3.1

www.cloriuscontrols.com

 


background image

Connection diagram

Modulating action

01

MM

2pt

03 05 06

24 V~/=

02

yo=0...10V

y=0...10 V

y=4...20m A

24 V~/=

05

MM

03

01

0%

100%

Spindle

02

06

3pt

24 V~/=

01

MM

03 05 06

02

M

µC

A1

07

65

2pt/3pt multi-position action with feedback signal

01

MM

2pt

03 05

06

24 V~/=

02

yo=0...10 V

01

MM

3pt

03 05

06

24 V~/=

02

yo=0...10 V

A1

07

64

Modulating action with forced operation

yo=0...10 V

24 V~/=

05

MM

03

01

0%

100%

Spindle

02

06

µC

A1

07

66

y=0...10 V

y=4...20 mA

Product data sheet

99.70.06-C

3.1

7/8

www.cloriuscontrols.com

 


background image

Dimension drawing

Type

a

b

c

AVM 321

53

187.4

33

AVM 322

64

241

44

Accessories

141

137

31

71

87

78

M1

1518

Product data sheet

99.70.06-C

8/8

3.1

www.cloriuscontrols.com