COMBUSTIBLE GAS LEAK DETECTOR

# 580952

Detects all Hydrocarbon and other Combustible Gases

MSHSA Approved, Intrinsically Safe

User Manual

Introduction

The

580952

features a long life heated sensor

technology that is designed to detect all combustible gases including
Methane, Propane, butane, Acetylene, Alcohol and Gasoline.

The unique digital leak size indicator of the

580952

takes the

guesswork out of whether or not to repair a small leak. The digital
display is independent from the audio alarm and sensitivity level,
allowing the precise pinpointing of the leak source.

The

580952

does not require rechargeable batteries.  An optional

detachable LED light will soon be available that clips on to the probe
to facilitate leak detection in low light environments.

Features

Unique numeric leak size indicator

Methane sensitivity < 10ppm

Low battery indicator

Audio mute function

Intrinsically Safe Certified

Bright 3 LED detachable light (optional)

2 year warranty including 2 years on the sensor

Long life, stable sensor

Automatic calibration & reset to ambient

3 adjustable sensitivity levels

Uses 4 AA alkaline batteries

Comfortable Sanoprene grip

CE certified

Made in USA

Gary or Ros OBORNE

Tel: 03 5768 2488 Fax: 03 5768 2688

sales@godistribution.com.au

www.cliplight.com

Leak Size Indicator

The digital leak size indicator remains off normally but once a leak is
detected, a number from 1-9 will be displayed for all combustible
gases

regardless of the sensitivity setting.

The number will continue to increase or decrease depending on the
amount of combustible gas sensed. The maximum value will be
displayed once the  leak source has been located.

Low Battery Indicator

Replace the 4 AA alkaline batteries when the red LED on the control
panel is lit. Follow battery installation Instructions under

Maintenance.

Operating Instructions

1.

Turn On:

Press the ON/OFF button once to turn

on and again to turn off

2.

Warm Up:

The detector automatically starts

heating the sensor. During the heating cycle, the
digital leak size indicator will flash

0

and the

detector will sound a slow “beep”. Warm  up is
usually less than 10 seconds.

3.

Ready:

The detector is ready to begin searching

for leaks when the flashing

0

stops and the green

sensitivity LED turns on. The audio “beep”
increases in frequency and probe LED begins to
blink steadily.

Audio Mute Function

To silence or mute the audio beep and alarm signal, press the MUTE
button. To restore the audio sound, press the MUTE button again.
Note: a few seconds is required to restore the sound if the mute
button is pressed in rapid succession.

 


background image

Adjusting Sensitivity Levels

The Leak Detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the
green LED will turn on.

To change sensitivity levels, press the SENS once for HI sensitivity (red LED will turn on) and again for LO sensitivity (yellow LED
will turn on).

Leak Test Vial

The leak detector comes with a Leak Test Vial that allows
the user to ensure the detector is performing properly. To
test:

1.

Remove the plastic seal cap on the Leak Detector Vial
by pulling it off (see Fig. 1)

2.

Turn on the detector and allow the unit to complete
the warm up cycle.

3.

Place the sensor close to the small hole in the top of
the Leak Test Vial. The beep rate should increase and
the Digital Leak Size Indicator should display a
number from 4-6 indicating that the sensor and
electronics are working properly.

Fig. 1

NOTE: always remember to

replace plastic seal cap after

leak test is completed. Replace

Test Vial when the green

colour is no longer visible.

Maintenance

Batteries:

Install Batteries:

Remove screw located at rear end of unit

and pull down hinged battery door to open as shown. Always
insert all four batteries into the battery compartment in
the same direction. Note polarity mark on the inside of the
battery door for proper battery orientation.

Sensor:

Replace Sensor:

Remove sensor by unscrewing sensor cover.

Install the new sensor by aligning the notch in sensor
socket with the raised tab on sensor socket holder. (see
figure below).

Unscrew cover to replace sensor

Push straight on (do not twist) to

install sensor

Note:

Do not force sensor into socket. Misalignment can

damage the sensor pins.

Ensure sensor is fully inserted for proper operation. The

detector will stay in warm-up mode and the on/off

switch will become inoperative if the sensor becomes

loose or is not fully inserted.