PDF User Manual

  1. Home
  2. Manuals
  3. Climatmaster ATA11C04 Quick Manual Programming

Climatmaster ATA11C04 Quick Manual Programming

Made by: Climatmaster
Type: Quick Guide Programming
Category: Thermostat
Pages: 2
Size: 0.04 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Description:

The ATA11CO4 series is a digital thermostat
with modes being heat, cool and auto change-
over with 2 speed fan and manual adjustment.

Package Contents:

1 ea. Thermostat
1 ea. Back Plate
1 ea. Remote Sensor Assembly
2 ea Self tapping screw 3/4” long
2 ea. Wall anchors
1 ea. Instruction manual

Specifications:

Temperature range: 32°F to 113°F
                                0°C to 45°C
Accuracy: ±1°F
Display: LCD
Load rating: Fan - 7 Amps; Heat/Cool 2 amps
Temperature Sampling: every 1 minute
Control range: Heat 36°F to 94°F
                       Cool 40°F to 98°F
Physical dimensions: 4.6 L x 2.8 W x 1.1 D

   ON      AUTO                        LO    HI

72.5

SET

F
A
N

OFF COOL

Display of Room or Set Point:

The room temperature will appear after the set point
has been displayed for 3 seconds.
To read “set point” press 

“SET”.

Heat mode:

When the room temperature drops below the set
point by the number of degrees of the differential, the
heating will turn on and the icon will display. The heat
will run until the heat setting is reached, Heat icon
flashing.

Cool mode:

When the room temperature rises above the set point
by the number of degrees of the differential, the
cooling will turn on and the icon will display. The cool
will run until the cool setting is reached, cooling will
turn off and Cool icon  flashing

Temporary Time Delay Override:

1- Select system mode (HEAT or COOL)
2- Press Reset Button.
Reset Button is located under the display 

case.

SET

SET

RESET BUTTON

ºF/ºC Jumper 

Differential:

1- Press        and        together for 10
seconds.
2- Display will show 1º and Diff
3- Press         or       to change the
selections from .5, 1, 1.5, 2

ºF/ºC Selections:

1- Turn Power OFF
2-  Jumper, Located at top left of display case.
3- Remove the Jumper for ºC selection.
     Jumper ON for ºF selection.
4- Turn Power ON.
5- Press RESET if desired Measurement has
     not been changed

Model   ATA11C04  Thermostat

Model A

T

A1
1C04

1 Stage Heat

1 Stage Cool

Auto Mode

            5000-0026  Rev. b 4-2006

Auto mode:

1. Move system switch to Heat mode.
   Select desired temperture for Heat mode
2. Move system switch to Cool mode
   Select desired temperature for Cool mode

Auto mode cont’d.:

3. Slide system switch to Auto mode.
    Example:
Heat = 68
Cool = 72
Note: make sure there is 4º dead band or
more between Heating and Cooling.
Otherwise the thermostat will automatically
push the cooling 4º below heating.

ON

AUTO


background image

Installation:

Be certain the power is turned off to the
thermostat.
All wiring and installation must conform to all
local and state codes. UL type Class II trans-
former must be used with 24 VAC model
thermostats.

Location:

Place the thermostat in a central location
where the family spends most of its time, such
as family or living room, etc.  Do not mount
the thermostat next to any doors, on outside
walls, near drafts, HVAC supply air, etc.

1. Mount Back Plate:

Using 2 screws with anchors install Mounting
Plate.

Wiring
Diagram:

Testing:

1. Program the Time delay.
2. Program the Differential.
3. Slide the Switch to “Heat” raise the setting to at
least 5 °F above the room temperature. Heat icon shall
energize after time delay period. When temperatures
reaches set point heat will turn off.
4. Slide the Switch to “Cool” lower the setting by at
least 5 °F below the room temperature. Cool icon shall
energize after time delay period. When temperatures
reaches set point cool will turn off.
5. Place the fan switch to “on” and change the fan
speed. The fan switch should change speeds.
6. When common is applied to the “L” terminal the
red LED will light. Indicating that the system requires
inspection by a service contractor.

2. Disconnect the front cover of thermostat.

 a) Mount the thermostat on the mounting
     plate supplied using the 2 screws.
 b) Pull the wires through the wire hole and
     install the wires to the terminal block. See
     wiring diagram.

After wiring is completed place cover on the
thermostat.

Th

e

rm

o

st

a

t

Lo Fan

Rev. Valve O or B

Hi Fan

Common

Compressor

C

Y

R

G

G2

O/B

S1

S1

Remote Sensor

2

4

 V

A

C

L

Lockout

Remote Sensor

1.0

.12

Remote Sensing:

1- Move Remote Jumper to the top 2 pins (see Fig 1).
2- Place the Remote Sensor to S1 and S1 Terminals.

Cooling And Heating Reverse Valve Selections:

1- Place The Jumper in 1 and 2 for O valve, 2 and 3
for B valve.

Warranty:

The ATA11C04 series of thermostats have  a limited
warranty for  one year against poor workmanship, not
meeting product specifications, etc. No other liability
will be incurred other than replacing the defective
product. For complete warranty details contact factory
for a detailed warranty.

SET

SET

S1  S1  L  C  R  Y  O/B  G  G2

REMOTE SENSOR

LOCAL SENSOR

O          B

RESET

ºF/ºC

Fig 1

Model   ATA11C04  Thermostat

5000-0026 Rev. b 4-2006

Remote Jumpers

Rev. Valve Jumpers