background image

FAN AIR MODULE  

FAM 1500 - 48 VDC

Operating and Service Manual

MADE IN 

ITALY

 


background image

PRESENTATION

This service manual gives all information requested for the knowledge, the correct use and the cor-

rect maintenance of all devices described in this Extraction Air Device. 

In case of no observance of the Manual’s contents, the Manufacturer will stop any guarantee on the

damaged product. 

In case of very difficult maintenance or revision, it is recommended to request the direct inter-

vention of the Manufacturer - that is, however, always at disposal for any suggestion finalized

to the solution of the problem. 

WARRANTY

All our products are guaranteed for 12 months after purchase’s date. The reparations under warran-

ty do not change the warranty period. The warranty concerns defects of materials that compromise

the function of product, reducing the efficiency or cancelling the effect of the device. The warranty

is recognised if the fault is reported within 2 days after the appearance.

The warranty does not include faults provoked by:

1 - physical/chemical characteristics of the ambient in which the device operates.

2 - not correct application of our instructions reported in this manual. 

3 - storage conditions non in accordance with this manual. 

4 - reparations carry out by not authorised service personnel.

And than, the warranty is also not applicable if:

5 - the Serial Number is not readable. 

6 - the Customer has not complied to all obligations with the Manufacturer, updated to the service

intervention. 

WARRANTY EXCLUSIONS 

The warranty is void in case of:

1 - error handling of the operator. 

2 - damage due to uncorrected service operation. 

3 - replacement of not original spare parts. 

4 - the operator did not follow the information indicated in this manual.

Also damages due to negligence, neglect, bad and inappropriate use of the machine exclude the war-

ranty. The elimination of safety devices will cause, automatically, the void of warranty and of any

responsibility from the Manufacturer.

LEGISLATION REFERENCES

The  machines,  object  of  this  Service  Manual,  have  been  made  in  accordance  with  EU  Directives,

reported in the rear page of this Manual.

Climatel

(Padova) 

di Giuseppe Giraldo

 


background image

Index

Pag. 0  Presentation

Pag. 0  Warranty 

Pag. 0  Exclusion of warranty

Pag. 0  Normative References

Pag. 1  Wall application

Pag. 1  Ceiling application

Pag. 2  Premise

Pag. 2  Use conditions

Pag. 2  Installation and connections

Pag. 2  Description of FAM 1500 - 48 VDC

Pag. 3  TAB. 1 - Technical Characteristics of FAM

Note 1

The technical characteristics of FAM could be changed by the Manufacturer without notice.

To size the electrical cables and for service interventions it is necessary to follow this Service Manual, annexed

to the machine. 

Note 2

All activities, as: Installation, Start-up/Adjustment and Maintenance, must be done by skilled workers or, as

choice, by Service of Manufacturer or by there representatives.

Pag. 3  Layout of FAM 1500

Pag. 4  TAB. 2 - Technical characteristics of the fan

Pag. 4  Electric Diagram of FAM 1500 - 48 VDC

Pag. 4  TAB. 3 - Manual fan speed regulator

Pag. 5  Start up

Pag. 5  Shut-off

Pag. 5  Maintenance

Pag. 5  Spare parts (standard)

Pag. 5  Disposal

Pag. 6  Declaration of Conformance

FAM 1500 - 48 VDC

1

Flexible hose 
Ø 200 mm

Flexible hose

Ø 200 mm

Air Suction grid 
with filter

Air Suction grid 
with filter

Fig. 1a - Wall Application of FAM 1500

Fig. 1b - Ceiling Application of FAM 1500

 


background image

2

FAM 1500 - 48 VDC

EXTRACTION AIR MODULE  FAM 1500 - 48 VDC

Premise

Before installing the machine, we recommend to read the instruction reported on page 0 of this manual.

Use conditions

FAM 1500 is a module that pushes outdoor the warm air of the conditioned room. An equivalent quantity of

new (and fresh) air will be sucked through a 

suction air grid

, fixed at the opposite wall of the room.

Installation and connections

The module could be:

A) 

fixed at an internal wall

of the room (in vertical position, Fig. 1a - 3) using the base frame fixing holes. 

Note: Do not fix the Module at light walls, generally not suitable to static and dynamic functioning of the

FAM module. 

B) 

fixed to the ceiling

(horizontally, Fig. 1b - 3) using the base frame fixing holes. 

Note: Do not fix the Module at light ceiling, generally not suitable to static and dynamic functioning of the

FAM module. 

To fix the electrical connections see Fig.4.

To install the machine it is mandatory to use appropriate Protective Equipment, as:

Description of FAM 1500 - 48 VDC

The module is made by a steel box (410x350xh220 mm), stove varnished, that includes:                              

a)

Axial fan

, directly coupled to a variable speed motor, with different air flows and head pressure (see TAB.1).

His motor is equipped with internal thermal relay, with automatic reset, that intervenes in case of electrical

or mechanical troubles.   

b) 

Internal screw terminals

to supply FAN at 48 VDC + earth.

c) 

Fan continuous speed regulator

, 0-10 VDC (but, in TAB. 1, we can see 4 situations only: low, medium,

high and maximum speed).

d) 

Air discharge flange

, with net, suitable for 200 mm diameter flexible duct.

Optional: Air grid with filter

, EU2 efficiency, that provides - continuously and in proper way - to clean the

new air to be mixed with the air present in the conditioned room.

Fig. 2 - FAM 1500 Module

wear appropriate 

work clothes

wear protective gloves

wear safety shoes

 


background image

FAM 1500 - 48 VDC

3

TAB. 1 - TECHNICAL CHARACTERISTICS OF FAM 1500 - 48 VDC

Characteristics

Unit of measure 

Value

Air flow (at 21 °C, density = 1.2 kg/m

3

)

m

3

/h 

1500 (nominal)

Air outlet connection flange (for flexible hose)

mm

200

Fan

Electric Supply (VDC +/- 10%) (EN 60204 - 1)

V

48 

Max Operative Power input

W

102

Max Electric absorption FLA

A

2,6

FAM Module protection (net)

mm

net 10x10

Weight (included air filter)

kg

8

Limits of use 

-20°C  

÷

+40°C

Fig. 3 - Layout of  FAM 1500

35

0

Suction air grid with 

adjustable flaps

300x300

30

30

Air Expulsion

Manifold for n°1 

flexible hose ø200

Hole ø6.5

350

220

 


background image

4

FAM 1500 - 48 VDC

TAB. 2 - TECHNICAL CHARACTERISTICS OF THE FAM AT 48 VDC

Static head pressure (mm H

2

O / Pa)

20,4 / 200

16,3 / 160

10,2 / 100

6,1 / 60

Air flow Q [m

3

/h]

700

1100

1500

1700

Revolution per minute [RPM]

1350

1320

1360

1410

Absorption [A]

2,53

2,60

2,52

2,43

Power absorbed [W]

101

102

100

98

Characteristics (air at 21 °C)

High  

prevalence

Medium 

prevalence

Medium-low

prevalence

Low 

prevalence

STOP

MAX

RED

YELLOW

WHITE (not used)

LIGHT BLUE

FA

N

 4

8V

D

C

Manual Speed regulator

Fig. 4 -  Electrical diagram 

FAM 1500 - 48 VDC

Electrical supply by user.

We recommend 

to protect FAM with 

adequate breaker, see TAB. 1 
Note: Fan speed Regulator is 

equipped with internal fuse.

Morsetti/

Connection

V+ / V-

Morsetti/

Connection

IN / V-

Minimo/

Minimum

(*) a mezzo trimmer esterno

Regolazione tensione/

Regulation Voltage

(*)

Impedenza Uscita/

Output impedance

Funzione STOP/

STOP function

V

MIN

IN/V-

R

IN

V+/V-

40 + 60 VDC

0÷5 VDC

V

MIN

÷10 VDC

5 kOhm max

Aperto/

Opened

Tensione

/

Voltage

(*) NOTA/NOTE

I valori di tensione si riferiscono senza carico applicato tra IN e V- / 

Voltage value are referred to no load present to IN / V-

TAB. 3 - FAN SPEED REGULATOR

Fig. 4a - Fan speed Regulator

trimmer

Fan speed regulator

The potentiometric control

of  fan  voltage  supply  is

equipped  with  switch-off

feature. A trimmer permits

to  calibrate  minimum

speed / power of the fan. 

To regulate the trimmer, a

simple  screwdriver  is

requested.

 


background image

FAM 1500 - 48 VDC

5

Start up

After connecting FAM module in accordance to Electric diagram Fig. 4, start the fan and calibrate the Fan speed Regulator

with the frontal knob (Fig. 4a) in according to the customer’s request (TAB. 2).

Set the minimum fan voltage value with the trimmer.

Switch off

Rotate the frontal knob anti-clockwise (Fig. 4a) (STOP position) until the fan stops.

Maintenance

IMPORTANT: it is strongly forbidden to access to the interior part of FAM when fan is running!

1- Ordinary maintenance and Control

Check every 6 months at least the fan electrical absorption (to compare with data of TAB.2).

Note: This control must be done without changing the FAM running conditions: openings of cabinet produce air by-pass and

amperage modifications. 

2- Extraordinary Maintenance  (      )

Where fan shows to high absorption or to high noise, intervene with expert personnel, as indicate on Note 2, page 1.

Standard Spare Part for FAM 1500 - 48 VDC (*)

Fan 

Fan manual speed Regulator

(*) Before requesting spares, check any reference stamped on the component.

Disposal

Disassembly / Scrapping

User, according to CE guidelines or to own country regulations, is responsible of disposal of the whole machine or also part

of it. This operation must be done following all safety precautions, specially during the following phases:

- Disassembly of machine from the operative site.

- Transportation and movement. 

- Disassembly

- Separation of single components.

Separation of materials and their recycling or disposal it is mandatory to apply the National and Regional Rules regarding

disposal of solid industrial waste.

ATTENTION!

Disposal of components and materials

In case of scrapping, according to local regulations, the customer must use special cautions regarding the disposal of: 

- PVC 

- ELECTRICAL CABLES

- STEEL

IMPORTANT NOTICE:

Toxic or corrosive substances are not present in this machine.

5

4

3

2

1

 

SENZA 

STOP

WITHOUT

STOP

CON

STOP

I

WITH

STOP

M

 

Regolazione

Regulation

Minimo

Minimun

 

 

 

IN

V-

V+

IN

V-

V+

Minimo

Minimun

Regolazione

Regulation

1
2
3
4
5

Minimo

Minimun

Regolazione

Regulation

1
2
3
4
5

Fig. 5 - Electrical diagram 

of Fan speed Regulator

Wear appropriate 

work clothes

Wear protective gloves

Wear safety shoes

Do not approach 

the hot surfaces

 


background image

CONFORMITY DECLARATION                     OF MANUFACTURE

IN  ACCORDANCE  WITH  DIRECTIVE  2006/42/CE 

Manufacture
Registered / operating seat

OBJECT OF DECLARATION

DECLARES

The machine in your possession was made in accordance to the following EU Directives:

•  Directive machine 2006/42/CE
•  Directive low tension 2006/96/CE
•  Directive electromagnetic compatibility 2004/108/CE

The person authorized to produce this technical documentation is:

(Legal representative)

Space for customized label

Climatel Freecooling