background image

Climate Comfort Anyplace Imaginable

OWNER’S MANUAL

FPO

Safety Instructions                           

Overview and Specifications          

 

Operating Instructions                    

Troubleshooting                            

Warranty                                        

Registration                                   

2 - 3 

5-7

8

9

10

 


background image

2

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock

or personal injury.

■ Use this appliance only for its intended purpose as described in this Owner’s Manual.

■ This air conditioner must be properly installed in accordance with the Installation Instructions before it is 

used.

■ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out 

from the receptacle.

■ Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged 

power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not 

repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or 

connector end.

■ Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

■ For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids 

in the vicinity of this or any other appliance.

■ All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. 

If you are getting rid of an old product with refrigerants, check with the company handling disposal about 

what to do.

■ If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

SAFETY PRECAUTIONS

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.  For personal 

safety, this appliance must be properly grounded. 

DO NOT use an adapter plug with this appliance. The power cord of this appliance is equipped with a 3-prong 

(grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of 

electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The 

device should be tested on a periodic basis by first pressing the TEST button and then the RESET button 

while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, 

discontinue use of the air conditioner and contact a qualified service technician.  Have the wall outlet and circuit 

checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced 

with a properly grounded 3-prong wall outlet.  The air conditioner should always be plugged into its own 

individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a 

fire hazard from overheated wires.  See the Installation Instructions, Electrical Requirements section for specific 

electrical connection requirements. 

HOW TO CONNECT ELECTRICITY

Operating Safety Instructions Care and Cleaning Instructions Installation Instructions Troubleshooting

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

SAFETY INSTRUCTIONS

 


background image

3

USE OF EXTENSION CORDS

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an 

extension cord. However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 

gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the 

electrical rating of the cord be 15 amperes (minimum) and 125 volts.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

FOR A DETAILED FAQ PLEASE VISIT WWW.CLIMATERIGHTAIR.COM FOR THE MOST 

ACCURATE AND UP-TO-DATE INFORMATION REGARDING YOUR UNIT.

SAFETY INSTRUCTIONS

 


background image

4

1.  Control Panel

2.  Power Cord

3.  Air Outlet Duct Port

4.  Air Inlet Duct Port

5.  Remote Control

Overview and Specifications

CR-5000-AC Specifications

Cooling btu

5050

Room Coverage*

Up to L10’ x W10’ x H8’ Room

Cooling Capacity  

(Room enclosure size) *

Up to 800 cu. ft.

Volts

115

Amps

4.9

Operating Watts

520 W

Dehumidifying (pts./hr)

1.1

Thermostat

Digital w/ infrared remote control

Control Panel features

Auto off timer, 3 fan and cooling speeds

Unit Dimensions (unboxed)

16”L x 15”W x 12”H

Case Dimension (boxed)

20” x 20” x 20”

Weight

50 lbs.

Refrigerant

r410a

Air Filter

included

Noise

55 decibels

Color

Off White

Recommended Generator

2000 w minimum

1

3

4

2

5

 


background image

5

Power Pad

Turns air conditioner on and off. When turned on, the display will show the room temperature.

Display

Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the tem-

perature in Cool or Energy Saver modes. The Set light will turn on while setting.

NOTE: The display will change to show the room temperature after settings have been made. To recall the Set tem

-

perature, press the Temp Increase ▲ or Decrease ▼ pads.

Temp Increase ▲ /Decrease ▼ Pads

Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.

Delay Timer Increase ▲ (+) /Decrease ▼ (–) Pads

Each touch of the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease – pads on the remote control 

will set the delay time when using the Delay 1–24hr timer (     ). The Set light will turn on while setting.

Fan Speed Pads

Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed In

-

crease + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

Mode Pad

Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.

Delay Pads

Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode 

and fan settings.  Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.

How to set:

Press the Delay 1–24hr pad on the unit or the     pad on the remote control. Each touch of the Increase ▲/ Decrease ▼ 

pads on the unit or the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set 

light will turn on while setting.  

To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the pad on the remote 

control. Use the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease – pads on the remote control to 

set a new time if desired.  To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes 

off.

1
2

5
6

3 4

7

7

4

6

5

3

4

5

5

1

1

2

3

4

5

6

7

OPERATING INSTRUCTIONS

 


background image

6

Do Not Operate in Freezing Outdoor Conditions 

This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor 

conditions.

Remote Control

How to Insert the Batteries in the Remote Control

1.  Remove the battery cover by sliding it according to the arrow direction.

2.  Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.

3.  Reattach the cover by sliding it back into position.

NOTES:

■ Use 2 “AAA” (1.5 volt) alkaline batteries. Do not use rechargeable batteries.

■ Remove the batteries from the remote control if the system is not going to be used for a long time.

■ To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

■ The remote control signal has a range of up to 20 feet. 

■ Make sure nothing is between the air conditioner and the remote that could block the signal.

■ Make sure batteries are fresh and installed correctly as indicated on the remote control.

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase ▲/ Decrease 

▼pads to set the desired temperature between 64°F and 86°F in 1°F increments.  An electronic thermostat is used to 

maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort.  Set the 

thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor 

air will become warmer.

Cooling Descriptions

For Normal Cooling

—Select the Cool mode and High or Med fan with a middle set temperature.

For Maximum Cooling

—Select the Cool mode and High fan with a lower set temperature.  

For Quieter & Nighttime Cooling

—Select the Cool mode and Low fan with a middle set temperature.

NOTE:

 If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool 

setting, it may take approximately 3 minutes for the compressor to start and cooling to begin. 

Energy Saver Mode

Controls the fan. 

ON

—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. 

Normally used when the room is unoccupied.

 

OFF

—The fan runs all the time, while the compressor cycles on and off.

NOTE:

 The fan may continue to run for a short time after the compressor cycles off.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan 

only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the 

display. 

NOTE:

Auto Fan Speed cannot be used when in the Fan Only Mode.

Auto Fan Speed 

Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings 

with the set temperature.  If the room needs more cooling, the fan speed will automatically increase. If the room needs 

less

cooling, the fan speed will automatically decrease.

NOTE:

 Auto Fan Speed cannot be used when in the Fan Only Mode.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is 

restored. If the Delay 1–24hr feature was set, it will resume countdown. You may need to set a new time if desired.

OPERATING INSTRUCTIONS

 


background image

7

OPERATING INSTRUCTIONS

Maintenance:

Your ClimateRight™ climate control unit should be a low- maintenance product and not require much attention if used in 

normal environments. However, over time with normal usage there are two (2) things that may need to be addressed.

Filters:

If used in the inlet and outlet pipes they will get dirty over time. Please remove and clean as desired.  A mesh filter is 

provided.  It is critical you keep this filter clean and free from debris and particles.  Check often as required.

Condenser:

On the back of the unit there is the condenser. If you notice the cooling ability of the unit degrading or if the fins of the 

condenser become dirty, they will need to be cleaned. Compressed air should be used to gently blow the unit out.

Note:

Failure to property care for your ClimateRight™ unit as mentioned above will result in the Warranty to be voided.

Uses:

ClimateRight™ can be used in a variety of ways. The possibilities are endless. We have many customers who currently 

use the unit for climate conditioning of dog houses, boat cabins, toll booths, tents, tear drop trailers, personal cooling in 

hot environments, electronic equipment, cabanas, and many more! 

 


background image

8

Troubleshooting

PROBLEM

POSSIBLE CAUSES

WHAT TO DO

Air conditioner does not 

start.

The air conditioner is 

unplugged. 

The fuse is blown/cir-

cuit breaker is tripped.

Power failure. 

 

 

 

 

 

 

 

The current interrupter 

device is tripped.

■ 

Make sure the air conditioner plug is pushed 

completely into the outlet. 

■ 

Check the house fuse/circuit breaker box and 

replace the fuse or reset the breaker. 

 

■ 

The unit will automatically re-start in the settings 

last used after the power is restored.

■ 

There is a protective time delay (approximately

3 minutes) to prevent tripping of the compressor

overload. For this reason, the unit may not start

normal cooling for 3 minutes after it is turned

back on. 

 

■ 

Press the RESET button located on the power 

cord plug. 

■ 

If the RESET button will not stay engaged, 

discontinue use of the air conditioner and contact 

a qualified service technician.

 

Air conditioner does not 

cool as it should.

Airflow is restricted.

 

 

 

The temp control may 

not be set correctly. 

 

The air filter is dirty.

The room my have 

been hot.

■ 

Make sure there are no curtains, blinds or 

furniture blocking the supply or return air vents. 

 

■ 

In the Cool mode, press the Decrease ▼ pad.

 

 

 

■ 

Clean the filter at least every 30 days.

■ 

When the air conditioner is first turned on, you 

need to allow time for the room to cool down.

The remote control is not 

working.

The batteries are in-

serted incorrectly.

The batteries may be 

dead.

■ 

Check the position of the batteries.  They should 

be inserted in the opposite (+) and (-) direction.

■ 

Replace the batteries.

Water build up in unit.

Moisture removed from 

air and drains into base 

pan.

■ 

This is normal for a short period in areas with lit-

tle humidity; normal for longer period in very humid 

areas.

Normal Operating Sounds

■ You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy 

days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

■ You may hear the thermostat click when the compressor cycles on and off.

■ Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip 

from the outdoor side of the unit.

■ The fan may run even when the compressor does not. 

 


background image

9

Warranty

LIMITED WARRANTY:

ClimateRight products (“ClimateRight”) are warranted by ClimateRight, LLC, the manufacturer and distributor of 

ClimateRight portable outdoor air conditioning and heating units, to be free from defective workmanship and materials, 

subject to the conditions set forth as follows:

 WHAT IS COVERED:

ClimateRight portable air conditioners and heaters are warranted, to the original owner within the 48 continental United 

States, for one (1) year from the date of purchase against manufacturer defects under normal use and service. This 

Warranty is not transferrable and applies only to original purchases and original purchase dates. After the expiration of 

the Warranty term (1 year), the owner is responsible for all costs associated with repair or troubleshooting

All warranty claims, whether purchased through authorized dealers, or ClimateRight LLC must be directed by email only 

– to service@climaterightair.com. Please provide the following information:

■ Customer Name

■ Email

■ Ship-to address

■ Where purchased and date and proof of purchase (order confirmation)

■ Nature of the problem.

If warranty claim is received within 30 days from purchase date, original purchase will be verified and a replacement unit 

will be shipped out with a prepaid return label to return malfunctioning unit. Malfunctioning unit must be received within 

15 days of receipt of replacement unit or charges will be billed for replacement unit at retail cost.

ClimateRight, LLC, will notify customer by email the status of the Warranty claim. If ClimateRight, LLC,, at its sole 

discretion, deems your Warranty claim valid, a prepaid shipping label will be sent to the address provided for return of 

the climate right unit for inspection and repair or replacement at ClimateRight’s sole discretion. If during inspection the 

warranty has been found to be voided or invalidated the customer has the option of having unit repaired and/or returned 

at cost to the customer. ClimateRight’s shall incur no repair cost or return shipping cost on a ClimateRight unit deemed 

not covered under warranty.

 WHAT IS NOT COVERED:

Note: The ClimateRight is a versatile product used in many applications. However, ClimateRight cannot be expected to 

operate and maintain its intended quality when used in extreme or unreasonable circumstances and applications.

The following limitations apply to the coverage of the warranty. If ClimateRight, at its sole discretion deems any of the 

following apply the warranty is void regardless of purchase date.

■ 

Units/Labor charges after one (1) year of date of purchase.

■ 

Labor charges for installation, setup or training to use the product.

■ 

Shipping damage, and any damage caused by improper packaging for shipment to the authorized service center.

■ 

Cosmetic damage such as scratches and dents.

■ 

ClimateRights that have been altered or customized.

■ 

ClimateRights that have damage or failures due to improper maintenance. Please refer to maintenance program which 

is simply to clean or replace filters, rinse exposed coil and clean as required by the condition of the enclosed space and 

unit’s environment. (Complete maintenance kit sold separately.)

■ 

Normal wear and tear on parts or replacement of parts designed to be replaced, e.g. filters and hoses.

■ 

Damages or operating problems resulting from misuse, abuse, operation outside environmental specifications, uses 

contrary to instructions provided in the owner’s manual, accidents, acts of God, vermin, fire, flood, improper installation, 

unauthorized service, maintenance negligence, unauthorized installation or modification, or commercial use.

■ 

The use of ClimateRight products in commercial settings or in settings not specifically recommended on our official 

company web site.

■ 

Optional accessories, attachments, and appearance items.

■ 

Products that have been modified to perform outside of specifications without the prior written permission of TACOM 

Limited.

■ 

Products lost in shipment, or theft.

■ 

Products sold AS IS or from an unauthorized reseller.

■ 

Products that have had their serial numbers removed or defaced. Products with serial numbers that have been 

invalidated.

 

OBTAINING WARRANTY SERVICE:

All Warranty questions must be directed exclusively to service@climaterightair.com for processing.
WARRANTIES ARE IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING WITHOUT 

LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE 

EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW, IT IS LIMITED IN DURATION TO THE EXPRESS 

WARRANTY PERIOD ABOVE. NEITHER THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE 

FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY NATURE, 

INCLUDING WITHOUT LIMITATION, LOST REVENUES OR PROFITS, OR ANY OTHER DAMAGE WHETHER BASED 

IN CONTRACT, TORT, OR OTHERWISE. SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR 

CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES 

YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
THIS WARRANTY SUPERSEDES ALL PREVIOUS WARRANTY POLICIES.

 


background image

10

CR-5000-AC Registration

    Mr.     Mrs.     Miss    Ms.

 

First Name

 

Last Name

 

Apt. No/APP/RR#

 

Address 1

 

Address 2

 

City

 

State

 

Province

 

Zip Code/Postal Code

 

Telephone 

 

Email Address

 

Date of Purchase

 

Serial Number

 

Is Copy of reciept included?

     Yes             No

Fill out the form below to register your ClimateRight unit.  In order to ensure you recieve full warranty 

coverage, please make sure to include a copy of your reciept with the purchase date clearly visible.  

Unless otherwise noted through registration, the warranty will start the shipment delivery date.

We will not sell or rent your information to any third party. The data collected from this form is for the 

explicit use of ClimateRight and affiliated persons and companies. However, we will disclose personal 

information when required or permitted by law or for purposes relevant to Corporate Policies.  The 

information is used to identify or track customer orders and to improve our products and services.

Registration

Mail form to: