Full Text Searchable PDF User Manual

661
29902621
CCS-24HR4LW
OWNER'S MANUAL
Models:
WALL SPLIT TYPE
WALL SPLIT TYPE
carefully before operating the unit and keeps it carefully
Thank you for choosing
this
air conditioner
for correct operation, please read this owner's manual
for consultation.
CLIMATE CONTROL
CLIMATE CONTROL


■
................................
1
■
.
......................
5
■
.....................
6
■
...
.......................
..
.......
9
■
...................................
1
1
■
...........
....
..........
1
6
■
...........
..................
....
1
7
■
...................
......
........
19
■
.........
.
.......
2
0
■
.................
........
......
1
4
CONTENTS
Operation and maintenance
Notices for operation
Notices for use
Names and functions of each part
Operation of wireless remote control
Clean and care
Troubleshooting
Installation service
Notices for installation
Installation dimension diagram
Install indoor unit
Install outdoor unit
C
heck after installation
and test operation
Thank you for choosing
this
air conditioner, please read this owner's
manual carefully before operating the unit and keep it carefully for consultation.
This symbol stands for the items
should be forbidden.
This symbol stands for the items
should be followed.
■
....
.......
..........
..
..........
...
4

1
★
★
The air conditioner should be
operated with the voltage range
the rated voltage is 220-240V
~
,
when the voltage is very low, the
compressor vibrates terribly and
that will damage the refrigerant
system; When the voltage is very
high, the electrical component
would be easily damaged.
that is the rated voltage 10%,
Operation and maintenance-Notices for operation
Please read the following carefully before operating.
WARNING
When having a burning smell
or smoke, please turn off the power
supply and contact with the service
may be damaged, and may cause
center of
CLIMATE CONTROL
.
If the abnormity still exists, the unit
electric shock or fire.
Don't operate the air conditioner
with wet hands.
Otherwise, it can cause an electric
shock or fire.
Never cut off or damage power
cables and control wires. If the power
cable and signal control wire were
damaged, change them by professional
Power must adopts the special
circuit to prevent fire.
Otherwise, it can cause an electric
shock or fire.
Be sure to pull out the power
plug as the air conditioner not in use
for a long time.
Otherwise, the accumulated dusts
that may cause overheating or fire.
Never damage the electric wire
or use the electric wire, which is not
appointed.
Otherwise, it will cause overheating
or fire.
When cleaning, it is necessary
to stop driving and turn off the power
supply.
Cut off power supply
Otherwise, it may cause electric
shock or damage.
The power supply must adopt
the special circuit that with air switch
protection and assure it has enough
capacity. The unit will be turned on
or off according to your requirement
automatically, please do not turn on
or turn off the unit frequently, othe-
rwise disadvantage effect may be
caused to the unit.

2
★
★
★
★
★
★
5 ℃
★
Earth:The ground
be connected!
If not, please ask the qualified person-
nel to install. Furthermore, don't conn-
ect each wire to the gas pipe, water
pipe, drainage pipe or any other impr-
oper places.
Select the most appropriate tem-
perature.
It can preclude the electricity wasted.
Keep room coo-
er than outside
about
Don't leave windows and
doors open for a long time
while operating the air conditi-
oner.
Don't block the air intake or outlet
vents of both the outdoor and indoor
units.
Keep combustible spray away
from the units more than 1m.
It can cause afire or explosion.
It can decrease the air conditioning
capacity or cause a malfunction.
It can decrease the air conditioning
capacity.
Please note whether the install-
ed stand is firm enough or not.
If it is damaged, it may lead to
the fall of the unit and cause
the injury.
As falling off the outdoor unit
can be dangerous.
Don't step on the top of the
outdoor unit or place something
on it.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to
an
electric shock or fire, so
you
should
contact the service
center
of
CLIMATE CONTROL
to repair.
Notices for operation
★
Be sure to pull out the power
plug when not using the air co-
nditioner for a long time.
Otherwise, the accumulated dust
may cause fire or electric shock.

3
★
★
★
★
★
★
Don't blow the wind to animals and plants
directly. It can cause a bad influence to them.
Don't insert your hands or stick into the air
intake or outlet vents.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Don't place a space heater near the air
conditioner.
Or CO toxicosis may occur for imcomplete
burning.
Don't apply the cold wind to the body for a
long time.
It can cause the health problems.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
The power cords of this air conditioner adopt
X-type connection, please don't cut off or damage
the power cords and control cords. If they are
damaged, please ask the qualified personnel to
change them.
To adjust the airflow and direction appropriately.
At operating the louvers of air conditioner could be
adjusted by pressing the SWING button on wireless
remote control to change the airflow direction.
Guide louver
Notices for operation

4
*
*
*
*
*
*
*
★
24℃
-7℃
27℃
43℃
21℃
18℃
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged,
so that indoor ambient temperature decreased, its cooling capacity will increase
or decrease by outdoor ambient temperature.
Anti-freezing function
If the unit is running in COOL mode and in low termperature, there will be frost formed
on the heat exchanger, when indoor heat exchanger temperature decreased below 0
℃
,
the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged,
will increase, its heating capacity will decrease by outdoor ambient temperature.
so that indoor ambient temperature increased, so room heating capacity.
This heating air circulation system can enhance the indoor temperature
in a short while.
If outdoor temperature got lower, please operate with the other heating ventilating
equipments.
Defrosting:
When outdoor temperature is low but high humidity, after a long while running,
frost will form on outdoor unit, that will effect the heating effect, at this time,
the auto defrosting function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
Anti-freezing function:
In "HEAT" mode, if in the following status, the indoor heat exchanger haven't achieve
the certain temperature, that the indoor unit will not act, in order to prevent cool air blowing.
(Within 3mins)
1.Heating starts. 2.After Auto defrosting finished. 3.Heating under the low temperature.
The conditions of unit can't normally run
The following temperature range protection device may act, that may cause stop running.
"HEAT"
running
Under the relative humidity above 80%( doors and windows opened) when cooling or dihu-
midifying for a long time, there will be dew drip off near the air vent.
"COOL"
running
"DRY"
running
Outdoor temp above
Outdoor temp below
Indoor temp. above
Outdoor temp above
Indoor temp. below
Indoor temp. below
Notices for use

Indoor Unit
Outdoor Unit
Heating (This indicator
is black for single-
(1) Front Panel
(2) Guide louver
(3) Receiving window
(4) LED Board
(5) Wall Pipe
(6) Wrapping Tape
(7) Indoor & outdoor
cable
Cooling
Air inlet
Air Outlet
cooling unit).
Set Temp
(8) Drainage pipe
Wireless remote control
Air inlet
Air Outlet
⑺
⑹
⑸
⑴
⑶
⑵
⑷
⑻
5
Names and functions of each part

6
Operation of wireless remote control
Name and function of wireless remote control
Note: Be sure that there are no obstructions between receiver and remote controoler;
Don't drop or throw the remote control; Don't let any liquid in the remote control and
put the remote control directly under the sunlight or any place where is very hot.
Signal transmitter
Remote control
AUTO
COOL
DRY
FAN
(only for cooling and heating unit)
MODE
button
When the unit is turned on, can
select AUTO, COOL, DRY
FAN or HEAT mode.
and
SLEEP
button
In COOL, DRY, HEAT mode,
press this button once to turn on
the SLEEP button, when repress
ON/OFF
button
Press it to turn on the unit,
repress it to turn off the unit.
FAN
button
SWING
button
When the unit is turned on, press
this button, the SWING function
is active, when repressed, it will
turned off; When press this butt-
on twice continuously, the ON,
OFF of controller light function
will shift once.
W
hen the unit is turned on, in
AUTO, COOL, FAN, HEAT
modes, press this button can sele-
ct AUTO FAN, LOW, MED, HI-
GH fan speed, in DRY mode, the
fan speed is LOW speed, the fan
speed in all modes have memo-
ry function.
ON/OFF
ON/OFF
FAN
button
FAN
button
SWING
button
SWING
it once more to turn it off.
SLEEP
button
SLEEP
MODE
button
MODE
If turn off the light button (At
light turned on, continuously press
the swing button twice within
1second to turn off the light;
At light turned off, continuously
press the swing button twice within
1second to turn on the light),that
all the symbols except the running
symbol will be turned off; If the
sleep operation has been set up,
that all symbols except the running
symbol will be turned off.
HEAT

7
Operation of wireless remote control
Names and functions of wireless remote control
This wireless remote control is universal, and it could be used for many units, some buttons
of this control which are not available to this unit will not be described below.
Wireless remote control
TIMER OFF
button
Press this button once enter
into the TIMER OFF setting.
TEMP. Adjusting
button
In COOL, DRY,FAN or HEAT
modes, press these two buttons,
could set the temp., the setting
range is 16
℃
-30
℃
all modes
, the temp. in
have the memory function.
TIMER ON
button
Press this button once, enter into
TIMER ON setting, the timer
indicator starts to flash, when pre-
ss the H-UP button, the time of
timer on will be increased 1 minute,
when continuously press 1 second
or more, each ten minutes will be
increased 1 minute, in each 0.5
second, when press H-DOWN, the
time will be decreased 1 minute,
when continuously press 1 second
or above, in each 0.5 second, each
ten minutes will be decreased 1mi-
nute, and it runs at 12hour circulat-
ion.
CLOCK
Press this button once, the indicator
flashes, and enter into clock adjusting
state. In clock adjusting state, when
press H-UP once, the unit order of
minute will be increased 1, when
press 1 more seconds continuously,
e ch ten minutes will be increased
1 in each 0.5 second,.When press
H-DOWN once, the unit order of
minute will be decreased 1, when
press 1 more seconds continuously,
each ten minutes will be decreased
1 in each 0.5 second.When adjusting
has been finished,repress CLOCK
again to affirm.
button
TIMER OFF
TIMER OFF
button
button
CLOCK
CLOCK
TEMP.
TIMER ON
TIMER ON
button
TEMP. Adjusting
CANCEL
button
Press this button once, to cancel
all timer setting.
CANCEL
button
CANCEL
RESET
button
RESET
RESET
button
Press this button once, the control
will reset.

8
Operation of wireless remote control
1.
2.
3.
4.
5.
6.
7.
8.
ACL
The general procedure:
The selected procedure:
Press SLEEP button, to set the sleep.
Note: When select the AUTO mode, the unit can choose the suitable running modes, automatically, and can obtain
the comfortable effect.
Press MODE, select the desirable running modes.
Press FAN button, set the fan speed.
When press SWING button, the guide louver will swing automatically,when repressed the button, it will stop.
When press Temp-UP/ Temp-DN the button, to set the desired temp.
Press T-OFF/T-ON button, then press H-UP/H-DN button, to set the schedule time of turning on or turning off.
The wireless remote control adopts two AAA alkaline dry cells.
Slide the cell cover downward to take out the worn cells, then change two new ones.( note to the correct polarity.)
Cover the cell cover.
NOTE:
Don't confuse the new and worn
or batteries of different types.
If the wireless remote control would
not be used for weeks, please take
out batteries to prevent liquid leakage
from damaging it.
When operating the wireless remote control,
it should be in its receiving range.
The wireless remote control should be
placed about 1m or more away from
the TV or any other electric appliances.
Cell cover
Insert two AAA batteries.
1.
2.
After powered on, there is a warning tone sound by buzzer, all patterns displayer of indoor unit displayed,
a few seconds later, all the display will automatically turned off, except the POWER/ RUN light,
The POWER/RUN running light turns red, the unit is await.( NOTE: Each time when power on or receive
the signals from the wireless remote control, the buzzer will sound)
Press ON/ OFF button on the wireless remote control, POWER/ RUN indicator turns green, and display
the running mode and setting temp. etc, the unit starts to run.(NOTE: if set the SLEEP function or turn off
the light button, all the displays will be turned off except the POWER/ RUN indicator.
Guide for operation procedure
-Optional operation
Change the batteries

9
●
●
●
①
②
③
Clean and care
Caution
Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock.
Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock.
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft
cloth, or a cloth slightly moistened with water or cleanser.)
Clean the front panel (make sure to take it off before cleaning)
Take off the front panel
Along the direction of arrowhead to lift the front panel up, meanwhile
to hold both slots of the front panel and take it out forcibly and then
can take it off.
Washing
Clean with a soft brush, water and neutral detergent, and then to dry
it in the shade.
Install the front panel
Place two supporters of the front panel into the slots, along the
direction of arrowhead to cover and clasp the front panel. As show
in Fig.4(a,b)
Fig.4
Clean the air filter (Recommended once every three months)
Note: If dust is much more around the air conditioner, the air filters should be cleaned
many times. After taking off the filter, don't touch the fin of indoor unit, in order to avoid
hurt your fingers.
Take down the air filter
(a)
(b)
①
(a
)
At the slot of surface panel to open an angle, pull the air filter downward
and take it out, please see the Fig. 5(a,b,c).
o
C to clean, or it can
②
(b)
Fig. 5
(
c)
detergent should below 45
℃
), and dry it in the shade.
Note: Never use water above 45
fire, or can cause a fire or deformation.
Clean the air filter
To clean the dust adhering to the filters, you can either use a vacuum
cleaner, or wash them with warm water (the water with the neutral
cause deformation or discoloration. Never parch it by

1
0
①
②
③
④
①
②
③
④
Check before use
Be sure that nothing obstructs the air outlet and intake vents.
Check that whether ground wire is properly connected or not.
Check that whether the batteries of air conditioner are
changed or not.
Check that whether the installation stand of the outdoor
unit is damaged or not. If damaged, please contact the dealer.
Maintain after use
Turn main power off.
Clean the filter and indoor and outdoor units' bodies.
Clear dust and obstructions from the outdoor unit.
Repaint the rubiginous place on the outdoor unit to
Clean and care
prevent it from spreading.
Clean and care
Reinsert the filters along the direction of arrowhead, and then to cover
the cover and clasp it.
Insert the air filter
③

1
1
Troubleshooting
CAUTION
Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire.
Please check the following items before asking for repair, it can save your time and money.
Troubleshooting
Phenomenon
Once the air conditioner is stopped, it will
not operate in approximately 3minutes to
protect itself.
Not operate immediately when the air
conditioner is restarted.
The unit has no peculiar smell by itself. If has,
that is due to the smell accumulated in the
ambient.
Solution method: Cleaning the filter(refer to P10).
If problem still has, so need to clean air condi-
tioner.(please contact with
CLIMATE CONTROL
authorized
maintenance center.)
There's unusual smell blowing from the
outlet after operation is started.
Sound of water flow can be heard during the
operation.
The air conditioner is started, when it is running
the compressor started or stopped running, or
the unit is stopped, sometimes there is swoosh
or gurgle, the sound is due to refrigerant flowing,
they are not malfunctions.
from the air outlet vent.
In COOL mode, sometimes the mist emitted When the indoor temperature and humidity are
very high, this phenomenon would happen. This
is caused by the room air is swiftly cooled down.
After running for a while, indoor temperature and
humidity will fall down, the mist will die away.
Creaking noise can be heard when start or stop
the unit.
This is caused by the deformation of plastic due
to the changes of temperature.
waiting

1
2
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Troubleshooting
Phenomenon
The unit can not run
Break off
Troubleshooting
Has the power been shut down?
Is the circuit protection device tripped off or not?
Is voltage higher or lower?
(Tested by professionals)
Is the Timer correctly used?
Cooling(Heating) efficiency is not good. Is Temp. setting suitable?
Were inlet and outlet vents obstructed?
Is filter dirty?
Are the windows and doors clothed?
Did Fan speed set at low speed?
Is there any heat sources in the room?
Wireless remote control is not available The unit is interfered by abnormal or frequent
functions switchover occasionally the controller
cannot operate. At this time, you need to pull
out of the plug, and reinsert it.
Is it in its receiving range? Or obstructed?
To check the voltage in wireless remote control
batteries.
inside is charged, otherwise to replace the
Whether the wireless remote control is damaged.
If water leakage in the room
The air humidity is on the high side.
Condensing water over flowed.
The connection position of indoor unit drainage
pipe is loosed.
If water leakage in outdoor unit
When the unit is running in COOL mode, the
due to the water cooled down.
pipe and connection of pipe would be condensed
When the unit is running in Auto Defrosting mode,
the ice thawed and flowed out.
When the unit is running in HEAT mode, the
water adhered on heat exchanger dripped off.
Noise from indoor unit emitted.
The sound of fan or compressor relay is switching
on or off.
When the defrosting is started or stop running,
it will sound. That is due to the refrigerant flowed
to the reverse direction.

1
3
●
●
●
▲
▲
▲
▲
▲
▲
Phenomenon
Moisture on air outlet vent
Troubleshooting
In HEAT mode, when the temperature of indoor
heat exchanger is very low, that will stop deliver
air in order to prevent blowing cool air.
In HEAT mode, when the outdoor temperature
is low or high humidity, there are much frost
be formed on the outdoor heat exchanger,
that the unit will automatically defrost, indoor
unit stop blowing air for 3-12min. During the
In dehumidifying mode, sometimes indoor fan
will stop, in order to avoid condensing water be
vaporized again, restrain temperature rising.
defrosting, there is water flowing out or vapor be
produced.
Indoor unit cannot deliver air
If unit is running under the high humidity for a
the air
outlet grill and drip off.
long
time, the moisture will be condensed on
Immediately stop all operations and plug out, contact
the dealer in following situations.
There is harsh sound during operation
.
The terrible odors emitted during operation
.
Water is leaking in the room
.
Air switch or protection switch often breaks
.
Carelessly splash water or something into air conditioner
.
There is an abnormal heat in power supply cord and power plug.
Stop running and pull out of the plug.
Troubleshooting

1
4
Installation service- Notices for installation
1.
2.
4.
5.
6.
7.
8.
1.
3.
1.
2.
3.
●
●
●
●
●
●
10
.
11
.
The appliance shall not be installed in the laundry.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep the interconnection cable
away from the copper tube.
9
.
Important Notices
The unit installation work must be done by qualified personnel according to the local
rules and this manual.
Before installating, please contact with local authorized maintenance center, if unit is
not installed by the authorized maintenance center, the malfunction may not solved,
due to discommodious contacts.
When removing the unit to the other place, please firstly contact with the authorized
CLIMATE CONTROL
Maintenance Center in the local area.
Basic Requirements For Installation Position
Install in the following place may cause malfunction. If it is unavoidable contact with
service center please:
Place where strong heat sources, vapors, flammable gas or volatile objuct are emitted
.
Place where high-frequency waves are generated by radio equipment, welders and
medical equipment.
Place where a lot of salinities such as coast exists.
Place where the oil (machine oil) is contained in the air.
Place where a sulfured gas such as the hot spring zones is generated.
Other place with special circumstance.
Indoor Unit Installation Position Selection
The air inlet and outlet vent should be far from the obstruction, make sure that the air
can be blown through the whole room.
Select a position where the condensing water can be easily drained out, and the place
is easily connected for outdoor unit.
Select a location where the children can not reach.
Can select the place where is strong enough to withstand the full weight and vibration of
the unit. And will not increase the noise.
Be sure to leave enough space to allow access for routine maintenance. The height of the
installed location should be 2
5
0cm or more from the floor.
Select a place about 1m or more away from TVset or any other electric appliances.
Select a place where the filter can be easily taken out.
Make sure that the indoor unit installation should accord with installation dimension
diagram requirements. (on page 17)
Outdoor Unit Installation Position Selection
Select a location from which noise and outflow air emitted by unit will not inconvenience
neighbors, animals, plants.
4
.
A air switch having a contact separation of at least 3mm in all poles should be fixed in
fixed wiring.
5
.
The appliance shall be installed in accordance with national wiring regulation.
12
.
Avoid a location where there is heat source high humidity or inflammable gas.
13
.
Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swi-
mming pool.

1
5
1.
2.
3
.
4
5
.
●
●
●
Earthing requirements
Air conditioner is type
I
electric appliance, thus please do conduct reliable earthing
measure.
The yellow-green
two-color
wire
in
air
conditioner is earthing wire and cannot be used
for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause
electric shock.
The user power must offer the reliable earthing terminal. Please don't connect the
earthing wire with the following place:
①
Tap water pipe
②
Gas pipe
③
Contamination pipe
④
Other places that professional personnel consider them unreliable.
Note:
It should be reliably earthed, and it should be connected to the special earth device,
the installation work should be operated by the professional.
The air switch must have the functions of magnetic tripping and heat tripping, in order
to protect the short circuit and overloading.
.
The min. distance from the unit and combustive surface is 1.5m.
In the family, the live wire, neutral wire in the power supply
wrong connection may cause fire.
Earth
(
)
Neutral wire (N)
Live wire (L)
socket that should be connected as the right figure, position
cannot be wrong connected, and should reliably connected,
there should be not short circuit in the inside.
The power supply should be used the rated voltage and AC exclusive circuit,the power
cable diameter should be satisfied.
1
.
3
.
2
.
Voltage applying range: the normal running range is rated voltage 90%-110%.
Don't drag the power cable emphatically.
Safety Requirements For Electric Appliances
Notices for installation
6.
7
.
8
.
9
.
Make sure that the outdoor unit installation dimension should accord with installation
dimension diagram, convenient for maintenance, repair.
(
on page
17)
The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.
Select a place where it is out of reach for the children.
Select a place where will not block the passage and do not influence the city appearance.
4.
5.
The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
Select a dry place, but do not expose under the direct sunlight or strong wind.
2.
3.
Select a location where there should be sufficient ventilation.
Select a location where there should be no obstructions cover the inlet and outlet vent.

1
6
F
From the ceiling
15cm
From the Wall
Over
Over 15cm
rom the Wall
Over
300cm
Over
250cm
Discharge Side
Above the floor
Over 30cm
From the Wall
Over 50cm
From the Wall
Discharge Side
v
O
r
e
m
c
0
3
r
e
v
O
200cm
572(mm)
378(mm)
mc
05
re
v
O
Over 15cm
Installation dimension diagram
Installation dimension diagram

1
7
φ65mm
φ65mm
Ø
65
Install the rear panel
1
. Always mount the rear panel horizontally. As the water drainage pipe at the left, when
adjusting the rear panel, this side should not be too high; the right side should be slightly high.
2.
Fix the rear panel on the selected
location.
3.
Be sure that the rear panel has
been fixed firmly enough to withstand
the weight of an adult of 60kg,
furthermore, the weight should be
evenly shared by each screw.
Mark on the middle of it
Gradienter
Wall
Wall
Space to
the wall
150mm
above
Space to
the wall
150mm
above
Left
Right
(Rear piping hole)
(Rear piping hole)
Install the piping hole
1
.
Make the piping hole
(ф
65
)
in the wall at a slight downward
slant to the outdoor side. At Fig.6.
2
.
Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Indoor
Outdoor
Wall pipe
Seal pad
Protection
sleeve pipe
Install the water drainage pipe
1.
For well draining, the drain hose should be
placed at a downward slant.
Do not wrench or bend the drain hose or flood
its end by water.
2
.
3
.
When the long drainage hose passing through
indoor, should wrap the insulation materials.
Wrenched
Bent
Flooded
Connect indoor and outdoor electric wires
1
.
Open the front panel upwardly;
2
.
Screw off the fixing screw of cover plate
and screw off cover
plate (As show in Fig. 7)
3
.
Put the power connection cable through the
back of indoor unit wire hole and take it ou
4
.
Connect the blue
wire
of powe
r
connection
cord to the terminal on “N(1)”, the black one to
“2”, the brown one to " 3",the yellow-green one
earth wire to (As shown in Fig. 8)
5
.
Put the power connection cable the section,
which with sheath into wire groove, and cov
the cover plate, screw on the fixing screw
tighten the connection wire.
6
.
Cover the front panel cover.
For the cooling and heating unit, signal control
7
.
wire can be passed through the connection of
connector and indoor unit, and use the wire clip
that is under the body case, tighten the signal
control wire (As show in Fig. 9)
Power
connection
wire
Wire terminal
cover plate
Fig.7
Fig. 9
Fig. 8
Signal control wire
(Only for cooling and
heating type unit)
Power connection wire
Connector
Wire
clamp
Terminal
board
Blue
Black
Y
Brown
ellow-green
Installation Service- Install indoor unit
Fig.
6

1
8
●
●
●
●
●
●
1.
⑴
⑵
2.
3.
4.
1
.
2
.
Ф6
Ф9.52
Ф
12
31~35
15~20
50~55
Install indoor unit
NOTE:
When connecting the electric wire if the wire length is not enough, please contact with
the authorized service shop to buy a exclusive electric wire that is long enough and the
joint on the wire are not allowed.
The electric wiring must be correctly connected, wrong connection may cause spare
parts malfunction.
Tighten the terminal screw in order to prevent loose.
After tighten the screw, slightly pull the wire and confirm whether is it firm or not.
If the earth wire is wrong connection, that may cause electric shock.
The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that
the dust, moisture may enter in or the connection terminal will be affected by outside force,
and will cause fire or elelctric shock.
Install the indoor unit
The piping can be lead out from right, right rear,
left, left rear.
When routing the piping and wiring from the left
or right side of indoor unit, cut off the tailings
from the chassis in necessary (show in Fig.10).
Cut off the tailings 1 when routing the wiring only;
Cut off the tailings 1 and tailings 2 when routing
both the wiring and piping.
Take out the piping from body case, wrap the piping
electric wire, water pipe with tape and put them th-
rough the piping hole (As show in Fig.11)
Hang the mounting slots of the indoor unit on the
upper tabs of the rear panel and check if it is firm
enough. (As show in Fig.12)
The height of the installed location should be 2.
5
m
or more from the floor.
Install the connection pipe
Align the center of the piping flare with the
relevant valve.
Screw in the flare nut by hand and then tighten
the nut with spanner and torque wrench refer
to the following.
Tightening torque table
Hex nut diameter Tightening torque table(N.m)
NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention
to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too
much, otherwise it may cause leakage.
Tailing 2
Tailing 1
Fig.10
Fig.11
Fig.12
Right
Right nether
Right rear
Left
Left rear
Mounting
board
Mounting
board
Fixing hook
Gas side piping
External connection
electric wire
Liquid side
piping
Gas side piping
Finally wrap it
with tape
Water drainage pipe
Liquid side
piping
insulation
Indoor unit piping
Taper nut Piping
Torque wrench
Spanner
insulation

19
2
.
3
.
4
.
●
●
Air purging and leakage test
Outdoor condensation drainage (Heat pump type only)
When the unit is heating, the condensing water
and defrosting water can be drained out reliably
Installation: Install the outdoor drain elbow in 25
hole on the base plate,and joint the drain hose to the
elbow, so that the waste water formed in the outdoor
Ø
Fig 1
3
Fig 1
4
1. Remove the nut cover at the shutoff valve.
2. Align with the center of the fitting pipe and manually
tighten the conical nut sufficiently.
3. Use spanner to tighten the conical nut.
4. Remove the liquid valve cap, the gas valve cap and
the nut of refrigerant charging mouth.
5. Use inner hexagon spanner to twist off the liquid valve
body and at the same time use screwdriver to open
the valve core of the liquid valve. Now gas shall flow
out.
6. After gas continues flowing out for about 15 second
and refrigerant gas begins to flow out, close the valve
core and tighten the nut of refrigerant charge mouth.
7. Completely open the valve body of the liquid valve
and the gas valve.
(
See Fig 1
3
)
8. Turn and tighten the valve cap, then use soap water
or a leak detector to check if there is gas leakage at
the outdoor and indoor units and the pipeline
connections.
9. If conditions permit, use a vacuum pump to exhaust
air in the unit from the valve core.
(
See Fig 1
4
)
Gas Pipe
Gas Valve
-76cmHg
Liquid Pipe
Liquid Valve
Inner Hexagon Spanner
Refrigerant Charge Mouth
Screwdriver
manifold valve
Multi-meter
Manometer
Hi handle
Lo handle
Charging hose
Charging hose
Low-pressure valve
Vacuum Pump
Chassis
Outdoor drain elbow
through the drain hose.
Indoor unit terminal board
Outdoor unit terminal board
wire
leakage test
Blue
Yellow-green
Diagram for cooling
and heating unit
Black
Brown
Installation service- Install outdoor unit
Electric wiring
1.
Remove the front side plate.
Take off wire clamp. Connect and fix power connect cord to
terminal of line bank. Wiring should fit that of indoor unit.
Fix the power connection cable with wire clamp, for cooling
and heating unit, then use the wire clamp to fix the signal
control wire, then connect the corresponding connector.
Ensure wire has been fixed well.
Note:
Wrong wiring may cause spare parts
malfunction.
After the cable fixed, make sure
there should be a free space between
the connection and fixing place on the
lead wire.
unit can be drained out to a proper plate.
Air purging and
Power connection
Brown
Blue Black
Yellow-green
Power connection
Wire clamp
wire
The signal control wire is only
fit for cooling and heating unit
Front side plate

2
0
1.
(1)
(2)
(3)
(4)
2.
(1)
(2)
Check after installation and test operation
Check after installation
Items to be checked
Possible malfunction
Has it been fixed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test? It may cause insufficient cooling(heating)
capacity.
Is heat insulation sufficient?
It may cause condensation and dripping.
Is water drainage well?
It may cause condensation and dripping.
Is the voltage in accordance with the rated
voltage marked on the nameplate?
It may cause electric malfunction
or damage the part..
Is the electric wiring and piping
connection installed correctly and securely?
It may cause electric malfunction
or damage the part.
Has the unit been connected to a secure
earth connection?
It may cause electrical leakage.
Is the power cord specified?
or damage the part
Is the inlet and outlet been covered?
It may cause insufficient cooling(heating)
capacity.
Has the length of connection pipes
and refrigerant capacity been recorded?
The refrigerant capacity is not accurate.
Test Operation
Before test operation
Do not switch on power before installation isfinished completely.
Electric wiring must be connected correctly and securely.
Cut-off valves of the connection pipes should be opened.
All the impurities such as scraps and thrums must be cleared from the unit.
Test operation method
Switch on power, press "ON/OFF" button on the wireless remote control to start the operation.
Press MODE button, to select theAuto, COOL, HEAT, FAN and Heat to check
whether the operation is normal or not .
It may cause electric malfunction