background image

Air Dehumidification System

Instruction Book – CLI-DH20-E

by

 


background image

2

CLI-MATE 

RECOMMENDS 

SAFETY FIRST

At Cli-Mate we are very 

safety conscious. We design 

and manufacture consumer 

products with the safety of you, 

our valued customer, foremost 

in mind. In addition we ask 

that you exercise a degree of 

care when using any electrical 

appliance and adhere to the 

following precautions.

IMPORTANT 

SAFEGUARDS

READ ALL 

INSTRUCTIONS BEFORE 

USE AND SAVE FOR 

FUTURE REFERENCE

•  All components need to 

be installed in accordance 

with the user manual 

instructions for correct 

performance of unit.

• This appliance should be 

used in conjunction with  

a safety switch.

• This appliance is not 

intended for use by 

persons (including 

children) with reduced 

physical, sensory or 

mental capabilities, 

or lack of experience 

and knowledge, unless 

they have been given 

supervision or instruction 

concerning use of the 

appliance by a person 

responsible for their safety.

2  

Cli-Mate Recommends 
Safety First

Components

Functions

13 

Care & Cleaning

14 

Troubleshooting

Contents

 


background image

3

• Do not operate any 

appliance with a damaged 

cord or plug or after the 

appliance malfunctions, or 

has been damaged in any 

manner.

• If the supply cord 

is damaged, it must 

be replaced by the 

manufacturer, its service 

agent or similarly 

qualified persons in order 

to avoid a hazard.

• Children should be 

supervised to ensure that 

they do not play with the 

appliance.

• Do not use appliance for 

other than intended use.

• Do not disassemble, repair 

or re-form the unit, it may  

cause injury, fire or other  

malfunctions. A qualified  

service agent must make  

all service adjustments.  

Unauthorised 

disassembling of the 

product will void  

the warranty.

• Unplug from outlet when 

not in use and before 

cleaning. Never plug in 

or unplug unit with wet 

hands. 

• Do not use unit outdoors 

or expose to greasy  

or damp environments.

• Keep the rear air inlet 

and outlet free from air 

blocking materials such 

as clothing, plastic bags  

or papers. Air flow  

is required for the unit  

to operate effectively.

• Place unit on a flat 

location at least 30cm 

from wall or other 

appliances.

• When the unit is in 

operation, keep all body 

parts, jewellery, hair and 

loose clothing away from 

the openings

• Unit must be placed  

on a stable flat surface to 

reduce possible excessive 

vibration and noise.

 


background image

4

• Keep the unit away  

from fire, flammable gas, 

combustible products  

or vapours, and corrosive 

substances.

• Do not operate the unit 

without filters.

• When transporting the  

air purifier, always hold 

the handles on the side  

of the unit.

• To protect against 

fire, electric shock and 

personal injury, do not 

immerse cord, plugs,  

or appliance in water  

or other liquid.

• Do not place on or near  

a hot gas, electric burner 

or heating appliance.

• Check voltage to be sure 

that the voltage indicated 

on the nameplate agrees 

with your voltage.

SPECIAL 

PRODUCT 

INSTRUCTIONS

•  This appliance is designed 

for household use only.  

Do not use this unit 

outdoors, in wet 

environments or on  

wet surfaces.

• To achieve best 

performance; make sure 

all doors and windows are 

closed before turning on 

the unit.

• The appliance air vents 

and air grilles must not 

be obstructed at any time. 

Air flow is required for the 

unit to operate effectively. 

Place unit in a flat location 

at least 30cm from wall or 

other appliances.

• Units must be placed on 

a stable flat surface to 

reduce possible excessive 

vibration and noise.

• Units must never be 

placed and operated on 

an angle as water spillage 

from reservoir can occur.

 


background image

5

• Empty the water when 

water reservoir is full or 

not in use for a prolonged 

period.

• Recommended operating 

temperature range is 

minimum 5°C  

(RH 40%) and maximum 

35°C (RH 90%).

• Any servicing other 

than cleaning and 

user maintenance will 

violate the terms of 

this WARRANTY and 

warranty will be null and 

void.

Note: RH = Relative Humidity

IMPORTANT 

SAFEGUARDS 

FOR ALL 

ELECTRICAL 

APPLIANCES

•  Unwind the power cord 

fully before use.

• Do not let the power  

cord hang over the edge 

of a bench or table, touch 

hot surfaces, or become 

knotted.

• To protect against electric 

shock do not immerse 

power cord, power plug  

or appliance in water  

or any other substance.

• This appliance is not 

intended for use by 

persons (including 

children) with reduced 

physical, sensory or mental 

capabilities, or lack of 

experience or knowledge, 

unless they have been 

given supervision or 

instruction concerning  

use of the appliance  

by a person responsible  

for their safety.

 


background image

6

FOR HOUSEHOLD USE ONLY  

SAVE THESE INSTRUCTIONS

• Children should be 

supervised to ensure  

they do not play with  

the appliance.

• It is recommended  

to regularly inspect the 

appliance. Do not use the 

appliance if power cord, 

power plug or appliance 

becomes damaged in  

anyway. Return the  

entire appliance to  

the nearest authorised  

Cli-Mate Service Centre  

for examination and/ 

or repair.

• Any maintenance other 

than cleaning should 

be performed at an 

authorised Cli-Mate  

Service Centre.

• This appliance is 

recommended for 

household use only.  

Do not use this appliance 

for anything other than 

its intended use. Do not 

use in moving vehicles or 

boats. Do not use outdoors. 

Misuse may cause injury.

• The installation of 

a residual current 

device (safety switch) 

is recommended to 

provide additional safety 

protection when using 

electrical appliances.  

It is advisable that  

a safety switch with  

a rated residual operating 

current not exceeding 

30mA be installed in the 

electrical circuit supplying 

the appliance. See your 

electrician for professional 

advice.

WARNING

Fully unwind the cord 

before use. 

 


background image

7

Components

A. 

Dry Air Outlet

B. 

Control Panel

C. 

LCD Display

D. 

Handle

E. 

Humid Air inlet

F. 

Air Filter

A

C

B

D

E

F

G

H

I

G. 

Continuous Drainage Outlet  

(For hose connection)

H. 

Water Reservoir

I. 

Continuous Drainage Hose*

*  Continuous drainage hose is an extra drainage 

option; hose does not need to be connected if using 
the water reservoir to catch condensed water.

 


background image

8

Components

Power   

Turns unit ON/OFF.

Mode 

Allows selection of desired working mode, the 

corresponding indicator light will illuminate.

Setting 

Allows selection of the desired running mode 

(High (H), Low (L)) and ambient relative 

humidity ratios.

LCD DISPLAY ICONS 

A. 

Automatic Dehumidifying 

B. 

RH Settings

C. 

Wind Speed

D. 

Water Full 

E. 

Ambient Humidity 

F. 

Swing

G. 

Dehumidifying

H. 

Timer

I. 

Defrost

J. 

Ambient Temperature 

K. 

Continuous Dehumidifying

Timer 

To set automatic ON/OFF timer at 1 to 24 hour 

settings.

Swing 

Turns air deflector ON/OFF to allow better 

distribution of air output.

CONTROL PANEL 

A

B

C

G

H

D

J

I

K

F

E

 


background image

9

OPERATION INSTRUCTIONS

1.  Plug unit into power socket, unit will beep 

twice.

2.  Press POWER button   to turn unit on. 

The dry air outlet air deflector will open 

and the blue backlight will illuminate and 

turn off after 15 seconds. The LCD display 

will show the working mode, status of unit, 

ambient humidity and temperature. 

NOTE

The dehumidification setting is automatically 

set on continuous   and default fan speed is 

set at High (H).

NOTE

The dry air outlet air deflector will close when 
unit is turned off. Press power button to turn 

unit off.
3.  MODE button sets up Continuous/

Automatic dehumidifying modes and Fan 

speed.

4.  SETTING button confirms the running 

fan speed or Continuous/Automatic 

dehumidifying ratio.

5.  To set automatic dehumidifying relative 

humidity (RH) ratio, press MODE button 

until LCD display lights up on the icon 

. Press SETTING button to select relative 

humidity (RH) ratio in 5% increments 

between 40% - 80%, and then press MODE 

to set selection, or three seconds after 

pressing SETTING the desired humidity 

ratio is set and the indicator light will stop 

illuminating

NOTE

When setting unit on automatic 

dehumidification, the continuous 
dehumidifying mode   will be cancelled. 
 

PRODUCT SPECIFICATIONS

CLI-DH20-E AIR DEHUMIDIFICATION SYSTEM

DEHUMIDIFICATION

20 LITRES/DAY

DEHUMIDIFYING CAPACITY

0.83 kg/hour

AIR CIRCULATION 

140 cbm/hour

POWER CONSUMPTION

340 watts

CAPACITY OF WATER TANK

3.8 L

REFRIGERANT

R134a (150 g)

NOISE LEVEL 

≤46dB

N.W

12.8 kgs

G.W

14.0 kgs

PRODUCT DIMENSIONS

350 x 242 x 586 mm

Functions

 


background image

10

NOTE

When the ambient relative humidity is 5% 
higher than the selected relative humidity ratio 

percentage (RH%), the unit will switch on and 
unit will operate at the selected setting.

NOTE

The unit will continuously run, regardless of 

the ambient relative humidity, when 
continuous dehumidification mode   is set.
6.  To set fan speed, press MODE button until 

LCD display lights  

up on the fan icon  . Press SETTING 

button to select between high (H) and low 

(L) fan speed, and then press MODE to set 

selection, or three seconds after pressing 

SETTING the fan speed is set. When fan 

speed is set the fan icon   will rotate.

NOTE

When the temperature sensor detects the 

ambient humidity is lower than selected 
setting, fan will work at a low (L) speed.

NOTE

When the temperature sensor detects the 
ambient room temperature to be higher or 
equal to 32°C, the unit fan speed will 
automatically switch to operate at high (H).
7.  To set continuous dehumidification, press 

MODE button until LCD displays the 
continuous dehumidification icon   and 

then press SETTING to set continuous 

dehumidification mode.

8.  To select ON/OFF timer. 

To set automatic OFF timer, press TIMER 

button when unit is powered ON; select the 

desired running time, 1 to 24 hours.  

Unit will automatically switch OFF once 

selected OFF time duration has lapsed. 

The screen will display time elapsed and 

remaining running time. 

To set automatic ON timer, press TIMER 

button when unit is powered OFF or on 

standby mode, select the desired time for 

unit to start operating in 1 to 24 hours. 

Timer symbol will be displayed on screen, 

and unit will automatically switch on when 

time is reached.

NOTE

Memory function will not work on Timing 

shutdown.
9.  When unit is powered ON, press SWING to 

oscillate dry air outlet deflector panel from 

50 to 95 degree angle automatically, LCD 

will display swing icon 

. Press SWING 

again to fix stationary angle, swing icon will 

disappear.

10. As unit operates, condensed water will drain 

into water reservoir. When water reservoir 

is full unit will beep 10 times and WATER 

FULL   indicator light will illuminate and 

all other indicator lights will turn orange. 

Unit will automatically stop operating. 

The water reservoir must be removed and 

emptied before unit will operate again. 

Remove water 
reservoir in 
accordance with 
arrow direction

 


background image

11

SAFETY FEATURES

Automatic Defrosting

To ensure the unit operates and performs as 

stated, the unit has been designed with an 

Automatic defrost function as frost can be 

produced on the surface of the evaporator in 

low temperatures.
When the temperature sensor detects the room 

temperature has dropped to 16°C or lower, 

the Auto Defrost function will start and the 

DEFROST symbol   will be displayed on the 

LCD screen. The unit compressor will run for 

25 minutes on dehumidification mode and 

then the fan will run at high speed in 7 minute 

cycles to defrost the unit.

NOTE

The dehumidification symbol   will disappear.

Protection Of Extremely Low 
& High Temperature

Unit is built with a room temperature sensor 

that will automatically shut off the unit when 

the ambient temperature is either less than 

or equal to 0°C or greater than or equal to 

40°C. When sensor is activated there will be a 

continuous warning beeper which will beep 3 

long and 2 short beeps and the corresponding 

temperature (either 0°C or 40°C) will be 

displayed on LCD screen.
 

NOTE

Unit will not be operable when sensor is 

activated, to restart unit, unplug unit and 

restart again.

NOTE

If unit is shut off due to protection of extremely 

low & high temperatures, the unit memory 

function will not operate, unit will reset at 

default setting.

Failure of Humidity & Temperature Sensor

When the connection wire between the 

humidity and temperature sensor is 

disconnected, the humidity icon   will blink 

and 0°C and 0% RH will display on LCD 

screen. Unit will switch into continuous 

dehumidifying mode.
If the temperature evaporator sensor becomes 

open circuit or short circuit the DEFROST light  

 will start blinking.

Unit will operate in a humidifying and 

defrosting mode, dehumidifying for 20 

minutes and then defrosting for 5 minutes.

NOTE

If the temperature sensor malfunctions, the 

unit will continue to work but at a lower 

efficiency.

Compressor Protection

If the unit malfunctions during the operation 

of the unit and the compressor fails, the 

compressor will switch off. Wait a minimum of 

three minutes to reoperate unit.

Memory Function

If the power is cut off during the operation 

of the appliance, the unit will memorise the 

working mode automatically.
Once power is restored to the unit, the 

appliance will restart and continue working at 

the last set working mode.

NOTE

If the ON/OFF timer has been set and 

activated, the unit will restart at default 

operating mode, not at previous set mode.

NOTE

If power supply is cut off due to one of the 

safety features being activated, the unit will not 

restart at previous set mode but at the default 

mode.

 


background image

12

Optional Continuous Drainage Installation

1.  Ensure that unit is OFF and unplugged 

from wall socket.

2.  Remove water reservoir out and connect 

water drain hose to spigot (continuous 

drainage outlet) as shown

Water 

spigot

3.  The other end of this hose must be placed 

over a water drain.

NOTE

For the unit to drain correctly, no part of the 

hose should be above the level of the water 

spigot (continuous drainage outlet).

 


background image

13

Care & Cleaning

CAUTION:

 Before carrying out any 

maintenance or cleaning of the unit, make 

sure that the power to the unit is turned off and 

power cord is removed from the power socket.
•  Do not clean unit with any abrasive cleaning 

agents or solvents.

•  Do not apply any water directly to the unit of 

cleaning.

•  Only use a soft clean cloth for all cleaning 

purpose 

CLEANING THE AIR FILTER:

Remove Air Intake Frame as shown below 

to access air filter. Use a vacuum cleaner or 

wash in cool water to clean filter. Allow to dry 

thoroughly before replacing filter and Air Intake 

Frame.

Air Intake Frame

Air Filter

STORAGE 

If not using the unit for a prolonged period, 

switch off and unplug the unit, empty the water 

reservoir, and allow minimum of two days for 

unit to dry before packing away. Keep unit in a 

dry and ventilated place.

REPAIR

If the unit or power cord is damaged, stop 

using immediately and bring the unit to 

authorised service centre for repair, never 
attempt to dismantle, repair or modify the unit 

by yourself. Warranty will be null and void.

 


background image

14

PROBLEM

POSSIBLE CAUSES

EASY SOLUTION

No Power.

• 

Unit is not plugged into  

wall socket.

• 

One of the units product safety 
features has been activated.

• 

Check connection to wall socket.

• 

Check indicator lights to determine 
which safety feature has been 
activated. If no lights, unplug 

unit and wait five minutes before 
restarting and operating appliance.  

If problem persists call customer 
care.

No Air.

• 

Unit is not plugged into wall socket

• 

Humidity ratio (if set) has been 
reached.

• 

Air outlet blocked.

• 

Water Reservoir is full.

• 

1. Check connection to wall socket

• 

Wait 30 minutes, turn unit back on.

• 

Ensure there are no objects 
obstructing air outlet.

• 

Empty water reservoir.

Unit Overheating.

• 

Air ventilation around unit  

not sufficient.

• 

Humid Air Inlet or air outlet is being 
obstructed or blocked by foreign 

objects.

• 

Internal malfunction.

• 

There must be at least 30cm between 

unit and wall or other appliances.

• 

Ensure there are no object 
obstructing the air intake grille or 

air outlet

• 

Return unit to service agent. Call 

customer care.

Loud Noise.

• 

Unit not on a level flat surface. 

• 

Faulty internals.

• 

Reposition or relocate unit onto a flat 
surface.

• 

Call customer care.

Water at Base of Unit.

• 

Water reservoir not installed 
correctly.

• 

Continuous drainage hose not  
connected to spigot properly.

• 

Continuous drainage hose outlet  

not over water drain.

• 

Reinstall water reservoir. 

• 

Check hose connection. 

• 

Check hose outlet is flowing into 

water drain.

Beeping Alarm Noise.

• 

Water Reservoir is Full.

• 

Ambient temperature is either less 
than or equal to 0°C or greater than 

or equal to 40°C.

• 

Remove and empty water reservoir

• 

Turn off unit and restart, or if unit 
is in defrost mode 

 

, allow unit to 

complete function and cycle.

Troubleshooting

 


background image

15

Notes

 


background image

Breville is a registered trademark of Breville Pty. Ltd. A.B.N. 98 000 092 928.  

Copyright Breville Pty. Ltd. 2018. 

Due to continued product improvement, the products illustrated/photographed  

in this brochure may vary slightly from the actual product.

CLI-DH20-E ANZ – A18