Congratulations on your purchase of a
Cli~Mate Air Dehumidification System.
This air dehumidifier is compact and stylish in design, quiet, portable and easy to operate. Unit effectively removes moisture
from the air creating a drier, healthier room environment.
Note: Please read through the instructions carefully before using or installing the product and ensure that the
manual is kept in a safe place for future reference.
The system must be properly installed and located in accordance with the installation instructions before it is used.
During the set up of this product if you have any questions / comments / issues DO NOT RETURN TO STORE.
FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT, FREE CALL 1300 764 325.
Electrical Requirements:
Australia / New Zealand 240V / 230V 50Hz
Due to manufacturing alterations product may
vary slightly from the pictured.

INSTALLATION AND OPERATING INSTRUCTIONS
1
SPECIAL PRODUCT INSTRUCTIONS
This appliance is designed for household use only.
Do not use this unit outdoors, in wet environments or on
wet surfaces.
To achieve best performance; make sure all doors and windows
are closed before turning on the unit.
The appliance air vents and air grilles must not be obstructed at
any time. Air flow is required for the unit to operate
effectively. Place unit in a flat location at least
30cm from wall or other appliances.
Units must be placed on a stable flat surface to reduce possible
excessive vibration and noise.
Units must never be placed and operated on an angle as water
spillage from reservoir can occur.
Empty the water when water reservoir is full or not in use for a
prolonged period.
Recommended operating temperature range is minimum 5°C
(RH 40%) and maximum 35˚C (RH 90%).
Any servicing other than cleaning and user maintenance will violate
the terms of this WARRANTY and warranty will be null and void.
Note:
RH = Relative Humidity
PRODUCT SPECIFICATIONS
Air Dehumidifier Specifications
System Specifications
CLI-DH20-E
Air Dehumidification System
Dehumidification
20 Litres/day
Dehumidifying Capacity
0.83 kg/hour
Air Circulation
140 cbm/hour
Power Consumption
340 watts
Capacity of Water Tank
3.8 L
Refrigerant
R134a (150 g)
Noise Level
≤
46dB
N.W
12.8 kgs
G.W
14.0 kgs
Product Dimensions
350 x 242 x 586 mm

2
INSTALLATION AND OPERATING INSTRUCTIONS
OPERATION CONDITIONS AND SAFETY PRECAUTIONS
Read all instructions carefully.
• All components need to be installed in accordance with the user
manual instructions for correct performance of unit.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
• A power outlet is required to operate the appliance. Electrical
supply required 220~240V/50Hz.
• Ensure unit is properly grounded.
• To protect against fire, electric shock and personal injury, do
not spray water onto the unit, do not immerse cord, plugs, or
appliance in water or other liquid. Do not push any objects in the
unit air inlet and air outlet exhaust grilles.
• Unplug from outlet when not in use and before cleaning. Never
unplug unit with wet hands.
• Do not operate any appliance with a damaged cord or plug or
after the appliance malfunctions, or has been damaged in any
manner.
• If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
• The use of accessory attachments not recommended by the
appliance manufacturer may result in fire, electric shock or
personal injury.
• Ventilation – The appliance air vents and exhaust grilles must
not be obstructed at any time. Air flow is required for the unit to
operate effectively. Place unit in a flat well-ventilated location at
least 30 cm from wall or other appliances.
• Do not use outdoors.
• Do not use in wet environments e.g. Bathrooms or Showers.
• Do not let cord hang over edge of table or counter, or touch hot
surfaces.
• Do not use appliance for other than intended use.
• This appliance should always be used in conjunction with a
safety switch.
• Do not place the unit near an oven, heater, radiator, direct
sunlight or any other heat source.
• Do not use unit near flammables or fire.
• Ensure unit is on a stable and even flat surface to prevent unit
from falling or tipping over and to reduce possible excessive
vibration and noise.

INSTALLATION AND OPERATING INSTRUCTIONS
3
• If unit ever tips or falls over when water reservoir is full,
immediately unplug the power cord. Ensure unit is dried
thoroughly before operation of the unit.
• Do not put fingers or other objects in any openings of the unit.
During the set up of this product if you have any
questions / comments / issues DO NOT RETURN TO STORE
FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT FREE
CALL 1300 764 325

4
INSTALLATION AND OPERATING INSTRUCTIONS
F
D
E
A. Dry Air Outlet
B. Control Panel
C. LCD Display
D. Handle
E. Humid Air inlet
F. Air Filter
G. Continuous Drainage Hose*
H. Continuous Drainage Outlet
(For hose connection)
I. Water Reservoir
* Continuous drainage hose is an extra drainage option;
hose does not need to be connected if using the water
reservoir to catch condensed water.
A. COMPONENT IDENTIFICATION AND CHECK LIST
G
H
I
A
B
C

INSTALLATION AND OPERATING INSTRUCTIONS
5
B. CONTROL PANEL & KEY PADS
POWER
Turns unit ON/OFF.
MODE
Allows selection of desired working mode, the corresponding
indicator light will illuminate.
SETTING
Allows selection of the desired running mode (High (H), Low (L))
and ambient relative humidity ratios.
TIMER
To set automatic ON/OFF timer at 1 to 24 hour settings.
SWING
Turns air deflector ON/OFF to allow better distribution of air output.
C. LCD DISPLAY ICONS
1. Automatic Dehumidifying
7. Dehumidifying
2. RH Settings
8. Timer
3. Wind Speed
9. Defrost
4. Water Full
10. Ambient Temperature
5. Ambient Humidity
11. Continuous Dehumidifying
6. Swing
Ti
m
er
S
ettings
M
od
e
S wing
1
2
3
7
8
4
10
9
11
6
5

6
INSTALLATION AND OPERATING INSTRUCTIONS
D. OPERATION INSTRUCTIONS
1. Plug unit into power socket, unit will beep twice.
2. Press POWER button
to turn unit on. The dry air outlet
air deflector will open and the blue backlight will illuminate
and turn off after 15 seconds. The LCD display will show
the working mode, status of unit, ambient humidity and
temperature.
Note:
The dehumidification setting is automatically set on continuous
and default fan speed is set at High (H).
Note:
The dry air outlet air deflector will close when unit is turned
off. Press power button to turn unit off.
3. MODE button sets up Continuous/Automatic dehumidifying
modes and Fan speed.
4. SETTING button confirms the running fan speed or Continuous/
Automatic dehumidifying ratio.
5. To set automatic dehumidifying relative humidity (RH) ratio,
press MODE button until LCD display lights up on the icon
.
Press SETTING button to select relative humidity (RH) ratio in 5%
increments between 40% - 80%, and then press MODE to set
selection, or three seconds after pressing SETTING the desired
humidity ratio is set and the indicator light will stop illuminating.
Note:
When setting unit on automatic dehumidification, the
continuous dehumidifying mode
will be cancelled.
Note:
When the ambient relative humidity is 1% lower than the
selected relative humidity ratio percentage (RH%), the unit
compressor will switch off and fan speed will operate at a Low (L).
Note:
When the ambient relative humidity is 5% higher than the
selected relative humidity ratio percentage (RH%), the unit will
switch on and unit will operate at the selected setting.
Note:
The unit will continuously run, regardless of the ambient
relative humidity, when continuous dehumidification mode
is set.
6. To set fan speed, press MODE button until LCD display lights
up on the fan icon
. Press SETTING button to select
between high (H) and low (L) fan speed, and then press MODE
to set selection, or three seconds after pressing SETTING
the fan speed is set. When fan speed is set the fan icon
will rotate.
Note:
When the temperature sensor detects the ambient humidity
is lower than selected setting, fan will work at a low (L) speed.
Note:
When the temperature sensor detects the ambient room
temperature to be higher or equal to 32°C, the unit fan speed will
automatically switch to operate at high (H).
7. To set continuous dehumidification, press MODE button until
LCD displays the continuous dehumidification icon
and then
press SETTING to set continuous dehumidification mode.

INSTALLATION AND OPERATING INSTRUCTIONS
7
8. To select ON/OFF timer.
To set automatic OFF timer, press TIMER button when unit is
powered ON; select the desired running time, 1 to 24 hours.
Unit will automatically switch OFF once selected OFF time duration
has lapsed. The screen will display time elapsed and remaining
running time.
To set automatic ON timer, press TIMER button when unit is
powered OFF or on standby mode, select the desired time for unit
to start operating in 1 to 24 hours. Timer symbol will be displayed
on screen, and unit will automatically switch on when time is
reached.
Note:
Memory function will not work on Timing shutdown.
9. When unit is powered ON, press SWING to oscillate dry
air outlet deflector panel from 50 to 95 degree angle
automatically, LCD will display swing icon
. Press SWING
again to fix stationary angle, swing icon will disappear.
10. As unit operates, condensed water will drain into water
reservoir. When water reservoir is full unit will beep 10 times
and WATER FULL
indicator light will illuminate and all other
indicator lights will turn orange. Unit will automatically stop
operating. The water reservoir must be removed and emptied
before unit will operate again. See Fig 1.
Note:
Allow minimum of three minutes before turning unit on,
after water reservoir is emptied.
Fig 1
Remove water
reservoir in
accordance with
arrow direction

8
INSTALLATION AND OPERATING INSTRUCTIONS
E. PRODUCT SAFETY FEATURES
1. Automatic Defrosting
To ensure the unit operates and performs as stated, the unit has
been designed with an Automatic defrost function as frost can be
produced on the surface of the evaporator in low temperatures.
When the temperature sensor detects the room temperature has
dropped to 16°C or lower, the Auto Defrost function will start and
the DEFROST symbol
will be displayed on the LCD screen.
The unit compressor will run for 25 minutes on dehumidification
mode and then the fan will run at high speed in 7 minute cycles to
defrost the unit.
Note:
The dehumidification symbol
will disappear.
2. Protection Of Extremely Low & High Temperature
Unit is built with a room temperature sensor that will automatically
shut off the unit when the ambient temperature is either less than
or equal to 0°C or greater than or equal to 40°C. When sensor
is activated there will be a continuous warning beeper which will
beep 3 long and 2 short beeps and the corresponding temperature
(either 0°C or 40°C) will be displayed on LCD screen.
Note:
Unit will not be operable when sensor is activated, to restart
unit, unplug unit and restart again.
Note:
If unit is shut off due to protection of extremely low & high
temperatures, the unit memory function will not operate, unit will
reset at default setting.
3. Failure of Humidity & Temperature Sensor
When the connection wire between the humidity and temperature
sensor is disconnected, the humidity icon
will blink and
0°C and 0% RH will display on LCD screen. Unit will switch into
continuous dehumidifying mode.
If the temperature evaporator sensor becomes open circuit or
short circuit the DEFROST light
will start blinking.
Unit will operate in a humidifying and defrosting mode,
dehumidifying for 20 minutes and then defrosting for 5 minutes.
Note:
If the temperature sensor malfunctions, the unit will
continue to work but at a lower efficiency.
4. Compressor Protection
If the unit malfunctions during the operation of the unit and the
compressor fails, the compressor will switch off. Wait a minimum
of three minutes to reoperate unit.
5. Memory Function
If the power is cut off during the operation of the appliance, the
unit will memorise the working mode automatically.
Once power is restored to the unit, the appliance will restart and
continue working at the last set working mode.

Fig 3
Air Intake Frame
Air Filter
Note:
If the ON/OFF timer has been set and activated, the unit will
restart at default operating mode, not at previous set mode.
Note:
If power supply is cut off due to one of the safety features
being activated, the unit will not restart at previous set mode but
at the default mode.
F. OPTIONAL CONTINUOUS DRAINAGE INSTALLATION
1. Ensure that unit is OFF and unplugged from wall socket.
2. Remove water reservoir out and connect water drain hose to
spigot (continuous drainage outlet) as shown in figure 2.
3. The other end of this hose must be placed over a water drain.
Note:
For the unit to drain correctly, no part of the hose should be
above the level of the water spigot (continuous drainage outlet).
G. MAINTENANCE AND REPAIR
Before carrying out any maintenance or cleaning of the unit, make
sure that the power to the unit is turned off and power cord is
removed from the power socket.
External cleaning of unit:
• Do not clean unit with any abrasive cleaning agents or solvents.
• Do not apply any water directly to the unit of cleaning.
• Only use a soft clean cloth for all cleaning purpose
Cleaning Filter:
Remove Air Intake Frame as shown in figure 3 below to access air
filter. Use a vacuum cleaner or wash in cool water to clean filter.
Allow to dry thoroughly before replacing filter and Air Intake Frame.
Fig 2
Water spigot

10
INSTALLATION AND OPERATING INSTRUCTIONS
H. UNIT NOT USED FOR PROLONGED PERIODS
If not using the unit for a prolonged period, switch off and unplug
the unit, empty the water reservoir, and allow minimum of two
days for unit to dry before packing away. Keep unit in a dry and
ventilated place.
Repair:
If the unit or power cord is damaged, stop using immediately and
bring the unit to authorised service center for repair, never attempt
to dismantle, repair or modify the unit by yourself. Warranty will be
null and void.

INSTALLATION AND OPERATING INSTRUCTIONS
11
I. TROUBLE SHOOTING
BEFORE YOU CALL FOR SERVICE PLEASE REVIEW THE TROUBLE SHOOTING TIPS FIRST.
Problem
Possible Causes
What To Do
No Power
1. Unit is not plugged into wall socket
2. One of the units product safety
features has been activated.
1. Check connection to wall socket
2. Check indicator lights to determine which safety feature has
been activated. If no lights, unplug unit and wait five minutes
before restarting and operating appliance. If problem persists
call customer care.
No Air
1. Unit is not plugged into wall socket
2. Humidity ratio (if set) has been
reached.
3. Air outlet blocked
4. Water Reservoir is full
1. Check connection to wall socket
2. Wait 30 minutes, turn unit back on.
3. Ensure there are no objects obstructing air outlet.
4. Empty water reservoir
Unit Overheating
1. Air ventilation around unit
not sufficient
2. Humid Air Inlet or air outlet is being
obstructed or blocked by foreign
objects.
3. Internal malfunction
1. There must be at least 30 cm between unit and wall or other
appliances
2. Ensure there are no object obstructing the air intake grille or
air outlet
3. Return unit to service agent. Call customer care.

Problem
Possible Causes
What To Do
Loud Noise
1. Unit not on a level flat surface
2. Faulty internals
1. Reposition or relocate unit onto a flat surface.
2. Call customer care.
Water at Base of Unit
1. Water reservoir not installed correctly
2. Continuous drainage hose not
connected to spigot properly.
3. Continuous drainage hose outlet
not over water drain
1. Reinstall water reservoir
2. Check hose connection
3. Check hose outlet is flowing into water drain.
Beeping Alarm Noise
1. Water Reservoir is Full
2. Ambient temperature is either less
than or equal to 0˚C or greater than
or equal to 40˚C.
1. Remove and empty water reservoir
2. Turn off unit and restart, or if unit is in defrost mode
,
allow unit to complete function and cycle.
Customer care 1300 764 325

Your Aquaport 12 Month Repair or Replacement Warranty
Aquaport warrants this appliance to the first purchaser and subject to
the stated conditions:
Warranty covers any defects in material or workmanship in the
manufactured product within the first twelve months from the date of
purchase.
To make a warranty claim you must call Aquaport on toll free number
1300 764 325 for instructions.
If a product is found to be faulty there is a 90 day return policy
from the date of purchase. Product returned to store MUST be
accompanied by a valid proof of purchase and Customer Reference
number received from Aquaport. Call 1300 764 325.
For warranty claims outside of 90 days from date of purchase, product
will be repaired or replaced at our discretion. Repair or replacement
costs of the product will be covered under warranty by Aquaport.
Goods presented for repair may be replaced by refurbished goods of
the same type rather than being repaired. Refurbished parts may be
used to repair the goods.
Warranty does not cover filter cartridge which is a consumable
unless proven to have defects in material or workmanship in the
manufactured product.
Our goods come with guarantees that cannot be excluded under
the Australian Consumer Law. You are entitled to a replacement or
refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if goods fail to be of acceptable quality and the
failure does not amount to a major failure. Register your warranty
online at
www.aquaport.com.au/warranty
Conditions Of This Warranty:
1. This product has been fully installed in accordance with the
user manual installation instructions.
2. The warranty extends only to repairing or replacing
any component that proves to be defective in material
or workmanship.
3. The warranty does not cover defects occasioned by misuse,
alterations, accidents, or used for other than the intended
purpose.
4. The warranty does not cover damage to the product caused by
accident, fire, or floods.
5. Proof of purchase is required for warranty claims.
Please keep purchase receipt in a safe place.
To enable us to register your warranty and provide service should a
problem occur, we recommend you register your warranty online at
www.aquaport.com.au/warranty
Aquaport Corporation Pty Ltd
5 John Street Flinders Park,
South Australia 5025
Customer Care 1300 764 325

CUSTOMER HOTLINE: 1300 764 325
Aquaport Corporation Pty Ltd
PO Box 81 Findon SA 5023 Australia
Telephone: 1300 764 325
Facsimile: 08 8354 0722
Email: aquaport@aquaport.com.au
Web: www.aquaport.com.au