background image

CLI-DH12 | Installation & Operating Instructions

Air  

Dehumidification

System

 


background image

 
 
 

CUSTOMER HOTLINE: 1300 764 325

Register your warranty online at www.aquaport.com.au/warranty
Aquaport Corporation Pty Ltd 
PO Box 81 Findon SA 5023 Australia
Telephone: 1300 764 325
Facsimile: 08 8354 0722
Email: aquaport@aquaport.com.au  
Web: www.aquaport.com.au

Congratulations on your purchase of a  
Cli~Mate Air Dehumidification System.

This air dehumidifier is compact and stylish in design, quiet, portable and easy to operate.  
Unit effectively removes moisture from the air creating a drier, healthier room environment.

Note: Please read through the instructions carefully before using or installing the product and ensure that the 
manual is kept in a safe place for future reference.

The system must be properly installed and located in accordance with the installation instructions before it is used.

During the set up of this product if you have any questions / comments / issues DO NOT RETURN TO STORE. 
FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT, FREE CALL 1300 764 325.

Electrical Requirements:
Australia / New Zealand 240V / 230V 50Hz
Due to manufacturing alterations product may 
vary slightly from the pictured. 

 


background image

INSTALLATION AND OPERATING INSTRUCTIONS  

1

 

 

SPECIAL PRODUCT INSTRUCTIONS

This appliance is designed for household use only. Do not use this 
unit outdoors, in wet environments or on wet surfaces.

To achieve best performance; make sure all doors and windows 
are closed before turning on the unit.

The appliance air vents and air grilles must not be obstructed at 
any time. Air flow is required for the unit to operate effectively. 
Place unit in a flat location at least 30cm from wall or other 
appliances.

Units must be placed on a stable flat surface to reduce possible 
excessive vibration and noise.

Units must never be placed and operated on an angle as water 
spillage from water reservoir can occur.

Empty the water when water reservoir is full or not in use for a 
prolonged period.

Recommended operating temperature range is minimum  
5°C (RH 40%) and maximum 35°C (RH 90%).

Any servicing other than cleaning and user maintenance will violate 
the terms of this WARRANTY and warranty will be null and void.

Note: RH = Relative Humidity 

PRODUCT SPECIFICATIONS

Air Dehumidifier Specifications

System Specifications

CLI-DH12 

Air Dehumidification System

Dehumidification

12 Litres/day

Dehumidifying Capacity

0.50 kg/hour

Air Circulation 

100 cbm/hour

Power Consumption

255 watts

Capacity of Water Tank

1.9 L

Noise Level 

46dB

N.W

9.7 kgs

G.W

10.6 kgs

Product Dimensions

290 x 201 x 476 mm

 


background image

2

 

 INSTALLATION AND OPERATING INSTRUCTIONS

OPERATION CONDITIONS AND SAFETY PRECAUTIONS

Read all instructions carefully.

• All components need to be installed in accordance with the user 

manual instructions for correct performance of unit.

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a 
person responsible for their safety.

• Children should be supervised to ensure that they do not play 

with the appliance.

• A power outlet is required to operate the appliance.  

Electrical supply required 220~240V/50Hz.

• Ensure unit is properly grounded.

• To protect against fire, electric shock and personal injury, do 

not spray water onto the unit, do not immerse cord, plugs, or 
appliance in water or other liquid. Do not push any objects in the 
unit air inlet and air outlet exhaust grilles.

• Unplug from outlet when not in use and before cleaning. Never 

unplug unit with wet hands.

• Do not operate any appliance with a damaged cord or plug or after 

the appliance malfunctions, or has been damaged in any manner. 

• If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard.

• The use of accessory attachments not recommended by the 

appliance manufacturer may result in fire, electric shock or 
personal injury.

• Ventilation – The appliance air vents and exhaust grilles must 

not be obstructed at any time. Air flow is required for the unit to 
operate effectively. Place unit in a flat well-ventilated location at 
least 30cm from wall or other appliances.

• Do not use outdoors.

• Do not use in wet environments e.g. Bathrooms or Showers.

• Do not let cord hang over edge of table or counter, or touch  

hot surfaces.

• Do not use appliance for other than intended use.

• This appliance should always be used in conjunction with a  

safety switch.

• Do not place the unit near an oven, heater, radiator, direct 

sunlight or any other heat source.

• Do not use unit near flammables or fire.

• Ensure unit is on a stable and even flat surface to prevent unit 

from falling or tipping over and to reduce possible excessive 
vibration and noise.

 


background image

INSTALLATION AND OPERATING INSTRUCTIONS  

3

 

 

• If unit ever tips or falls over when water reservoir is full, 

immediately unplug the power cord. Ensure unit is dried 
thoroughly before operation of the unit.

• Do not put fingers or other objects in any openings of the unit.

During the set up of this product if you have any questions/ 
comments/ issues DO NOT RETURN TO STORE

FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT FREE 
CALL 1300 764 325

 


background image

4

 

 INSTALLATION AND OPERATING INSTRUCTIONS

E

C

D

A. Dry Air Outlet
B. Control Panel
C. Handle
D. Humid Air inlet
E. Air Filter
F. Continuous Drainage Hose*
G. Continuous Drainage Outlet  
    (For hose connection)
H. Water Reservoir

* Continuous drainage hose is an extra drainage option; 
hose does not need to be connected if using the water 
reservoir to catch condensed water.

A. PARTS IDENTIFICATION DIAGRAM

F

G

H

A

B

 


background image

INSTALLATION AND OPERATING INSTRUCTIONS  

5

 

 

B. CONTROL PANEL & KEY PADS

POWER

 

Turns unit ON/OFF.

SPEED

 

Allows selection of dehumidification speed 
(High (H) /Low (L))  
Default unit SPEED is set at High (H).

HUMID

 

Allows selection of different room relative humidity ratios 
(40%/60%/80%/CONTINOUS). Unit is automatically set on CON 
(continuous dehumidification) mode when turned on.

TIMER

 

To set automatic ON/OFF timer at 1/2/4/8 hour settings.

AUTO

 

Turns Auto Dehumidification ON/OFF.

C. OPERATION INSTRUCTIONS

1.   Plug unit into power socket, unit will beep twice and LED monitor 

lights will illuminate for one second.

2.   Press POWER button   to turn unit on.

Note:

 The dehumidification setting is automatically set at CON 

(continuous dehumidification) and default dehumidification speed is 
set at High (H).

Note:

 Unit will run on CON (continuous dehumidification) mode 

unless a room relative humidity ratio (HUMID) or the AUTO 
dehumidification is selected.

3.   To select the dehumidification mode, press SPEED button to 

select High (H) or Low (L) respectively.

Note: 

When the temperature sensor detects the ambient room 

temperature to be higher or equal to 32°C, the unit fan speed will 
automatically switch to operate at High (H). When the temperature 
sensor detects the ambient temperature to be less than 30°C, the 
fan speed will run automatically at previous selected speed setting.

Note:

 When the temperature sensor detects the ambient humidity is 

lower than selected setting, fan will work at a Low (L) speed.

Note:

 When unit is operating in defrost mode, unit will run at High  

(H) speed.

4.   To select room relative humidity (RH) ratios, press HUMID 

button to select 40%~60%~80%~CON (continuous 
dehumidification) respectively.

 


background image

6

 

 INSTALLATION AND OPERATING INSTRUCTIONS

Note:

 When the ambient relative humidity is 1% lower than the 

selected relative humidity ratio percentage (RH %), the unit 
compressor will switch off and unit will operate at a Low (L)  
speed level.

Note:

 When the ambient relative humidity is 5% higher than the 

selected relative humidity ratio percentage (RH %), the unit will 
switch on and unit will operate at the selected SPEED setting.

Note:

 The unit will continuously run, regardless of the ambient 

relative humidity, when the CON (continuous dehumidification) 
mode is set.

5.   To select ON/OFF timer.

To set automatic OFF timer, press TIMER button when unit is 
powered ON; select the desired running time 1/2/4/8 hours 
respectively, timer LED lights will illuminate accordingly. Unit will 
automatically switch OFF once selected OFF time duration has 
lapsed. The screen will display time elapsed and remaining  
running time.

To set automatic ON timer, press TIMER button when unit is 
powered OFF or on standby mode, select the desired time for unit to 
start operating at 1/2/4/8 hours respectively, timer LED lights will 
illuminate accordingly. Timer symbol will be displayed on screen.

6.   To select auto dehumidification setting, press AUTO button, the 

AUTO LED light will remain illuminated. Unit will automatically 
adjust the humidity setting according to the ambient 
temperature.

Note:

 When the ambient relative humidity is less than or equal to 

24°C, the relative humidity ratio setting is 80%.When the ambient 
relative humidity is less than or equal to 24°C - 25 °C, the relative 
humidity ratio setting is 60%.When the ambient relative humidity  
is greater than or equal to 25°C, the relative humidity ratio setting 
is 40%.

Note:

 When AUTO humidity setting is activated, the previous 

relative humidity ratio or continuous mode will be deactivated.

7.   As unit operates, condensed water will drain into water 

reservoir. When water reservoir is full unit will beep 10 times 
and WATER FULL 

 indicator light will illuminate and all other 

indicator lights will turn orange. Unit will automatically stop 
operating. The water reservoir must be removed and emptied 
before unit will operate again. See Fig 1.

Note:

 Allow minimum of three minutes before turning unit on, after 

water reservoir is emptied.

Fig 1

Remove water 
reservoir in 
accordance with 
arrow direction

 


background image

INSTALLATION AND OPERATING INSTRUCTIONS  

7

 

 

D. PRODUCT SAFETY FEATURES

1.   Automatic Defrosting

To ensure the unit operates and performs as stated, the unit has 
been designed with an Automatic defrost function as frost can be 
produced on the surface of the evaporator in low temperatures.

When the temperature sensor detects the room temperature has 
dropped to 16°C or lower, the Auto Defrost function will start and 
the DEFROST 

 indicator light will illuminate. The unit compressor 

will run for 25 minutes on dehumidification mode and then the fan 
will run at high speed in 7 minute cycles to defrost the unit.

Note: 

The dehumidification symbol 

 will switch off when unit is in 

Defrost mode.

2.   Protection Of Extremely Low & High Temperature

Unit is built with a room temperature sensor that will automatically 
shut off the unit when the ambient temperature is either less than 
or equal to 0°C or greater than or equal to 40°C. When sensor  
is activated there will be a continuous warning beeper which will  
beep 3 long and 2 short beeps. The dehumidification symbol 

  

will illuminate.

Note:

 Unit will not be operable when sensor is activated, to restart 

unit, unplug unit and restart again.

3.   Failure of Humidity & Temperature Sensor

When the connection wire between the humidity and temperature 
sensor is disconnected, the humidity CON light will blink and 
switch unit into continuous dehumidifying mode.

If the temperature evaporator sensor becomes open circuit or 
short circuit the DEFROST 

 light will start blinking. Unit will  

operate in a humidifying and defrosting mode, dehumidifying for  
20 minutes and then defrosting for 5 minutes.

Note:

 If the temperature evaporator senor malfunctions, the unit 

will continue to work but at a lower efficiency.

4.   Compressor Protection

If the unit malfunctions during the operation of the unit and the 
compressor fails, the compressor will switch off. Wait a minimum 
of three minutes to reoperate unit.

5.   Memory Function

If the power is cut off during the operation of the appliance, the 
unit will memorise the working mode automatically. Once power 
is restored to the unit, the appliance will restart and continue 
working at the last set working mode.

Note:

 If the ON/OFF timer has been set and activated, the unit will 

restart at original operating mode, not at previous set mode.

Note:

 If power supply is cut off due to one of the safety features 

being activated, the unit will not restart at previous set mode.

 


background image

8

 

 INSTALLATION AND OPERATING INSTRUCTIONS

E. OPTIONAL CONTINUOUS DRAINAGE INSTALLATION

1.   Ensure that unit is OFF and unplugged from wall socket.

2.   Remove water reservoir out and connect water drain hose to 

spigot (continuous drainage outlet) as shown in figure 2.

3.   The other end of this hose must be placed over a water drain.

Note:

 For the unit to drain correctly, no part of the hose should be 

above the level of the water spigot (continuous drainage outlet).

F. MAINTENANCE AND REPAIR

Before carrying out any maintenance or cleaning of the unit, make 
sure that the power to the unit is turned off and power cord is 
removed from the power socket.

External cleaning of unit:

• Do not clean unit with any abrasive cleaning agents or solvents.

• Do not apply any water directly to the unit of cleaning.

• Only use a soft clean cloth for all cleaning purpose

Cleaning Filter:

Remove Air Intake Frame as shown in figure 3 below to access air 
filter. Use a vacuum cleaner or wash in cool water to clean filter. 
Allow to dry thoroughly before replacing filter and Air Intake Frame.

Fig 2

Water spigot

Fig 3

Air Intake Frame

Air Filter

 


background image

G. UNIT NOT USED FOR PROLONGED PERIODS

If not using the unit for a prolonged period, switch off and unplug 
the unit, empty the water reservoir, and allow minimum of two 
days for unit to dry before packing away. Keep unit in a dry and 
ventilated place.

Repair:

If the unit or power cord is damaged, stop using immediately and 
bring the unit to authorised service center for repair, never attempt 
to dismantle, repair or modify the unit by yourself. Warranty will be 
null and void.

 


background image

10

 

 INSTALLATION AND OPERATING INSTRUCTIONS

H. TROUBLE SHOOTING 

 

BEFORE YOU CALL FOR SERVICE PLEASE REVIEW THE TROUBLE SHOOTING TIPS FIRST.

Problem

Possible Causes

What To Do

No Power

1. Unit is not plugged into wall socket

2. One of the units product safety 

features has been activated.

1. Check connection to wall socket

2. Check indicator lights to determine which safety feature has 

been activated. If no lights, unplug unit and wait five minutes 
before restarting and operating appliance. If problem persists 
call customer care.

No Air

1. Unit is not plugged into wall socket

2. Humidity ratio (if set) has been 

reached.

3. Air outlet blocked

4. Water Reservoir is full

1. Check connection to wall socket

2. Wait 30 minutes, turn unit back on.

3. Ensure there are no objects obstructing air outlet.

4. Empty water reservoir

Unit Overheating

1. Air ventilation around unit  

not sufficient

2. Humid Air Inlet or air outlet is being 

obstructed or blocked by foreign 
objects.

3. Internal malfunction

1. There must be at least 30cm between unit and wall or other 

appliances

2. Ensure there are no object obstructing the air intake grille or 

air outlet

3. Return unit to service agent. Call customer care.

 


background image

INSTALLATION AND OPERATING INSTRUCTIONS  

11

 

 

 

 

Problem

Possible Causes

What To Do

Loud Noise

1. Unit not on a level flat surface

2. Faulty internals

1. Reposition or relocate unit onto a flat surface.

2. Call customer care.

Water at Base of Unit

1. Water reservoir not installed correctly

2. Continuous drainage hose not  

connected to spigot properly.

3. Continuous drainage hose outlet  

not over water drain

1. Reinstall water reservoir

2. Check hose connection

3. Check hose outlet is flowing into water drain.

Beeping Alarm Noise

1. Water Reservoir is Full

2. Ambient temperature is either less 

than or equal to 0°C or greater than 
or equal to 40°C.

1. Remove and empty water reservoir

2. Turn off unit and restart, or if unit is in defrost mode 

allow unit to complete function and cycle.

Customer care 1300 764 325

 


background image

Your Aquaport 12 Month Repair or Replacement Warranty

 Aquaport warrants this appliance to the first purchaser and subject to 
the stated conditions:
Warranty covers any defects in material or workmanship in the 
manufactured product within the first twelve months from the date of 
purchase.
To make a warranty claim you must call Aquaport on toll free number 
1300 764 325 for instructions.
If a product is found to be faulty there is a 90 day return policy 
from the date of purchase. Product returned to store MUST be 
accompanied by a valid proof of purchase and Customer Reference 
number received from Aquaport. Call 1300 764 325.
For warranty claims outside of 90 days from date of purchase, product 
will be repaired or replaced at our discretion. Repair or replacement 
costs of the product will be covered under warranty by Aquaport.
Goods presented for repair may be replaced by refurbished goods of 
the same type rather than being repaired. Refurbished parts may be 
used to repair the goods.
Warranty does not cover filter cartridge which is a consumable 
unless proven to have defects in material or workmanship in the 
manufactured product.
Our goods come with guarantees that cannot be excluded under 
the Australian Consumer Law. You are entitled to a replacement or 
refund for a major failure and compensation for any other reasonably 
foreseeable loss or damage. You are also entitled to have the goods 
repaired or replaced if goods fail to be of acceptable quality and the 
failure does not amount to a major failure. Register your warranty 
online at 

www.aquaport.com.au/warranty

Conditions Of This Warranty:

1.  This product has been fully installed in accordance with the  

 

 

user manual installation instructions.

2.  The warranty extends only to repairing or replacing    

 

 

any component that proves to be defective in material 

 

or workmanship.

3.  The warranty does not cover defects occasioned by misuse,  
 

alterations, accidents, or used for other than the intended  

 purpose.
4.  The warranty does not cover damage to the product caused by  
 

accident, fire, or floods.

5.  Proof of purchase is required for warranty claims.
 

Please keep purchase receipt in a safe place.

To enable us to register your warranty and provide service should a 
problem occur, we recommend you register your warranty online at 

www.aquaport.com.au/warranty

Aquaport Corporation Pty Ltd
5 John Street Flinders Park,  
South Australia 5025 

 

       

Customer Care 1300 764 325

 


background image

 


background image

CUSTOMER HOTLINE: 1300 764 325

Aquaport Corporation Pty Ltd  

PO Box 81 Findon SA 5023 Australia 

 Telephone:  1300  764  325    

Facsimile: 08 8354 0722 

 Email:  aquaport@aquaport.com.au   

Web: www.aquaport.com.au