Full Text Searchable PDF User Manual

Ultrasonic Humidification System
Instruction Book – CLI-AH201
by

2
CLI-MATE
RECOMMENDS
SAFETY FIRST
At Cli-Mate we are very
safety conscious. We design
and manufacture consumer
products with the safety of you,
our valued customer, foremost
in mind. In addition we ask
that you exercise a degree of
care when using any electrical
appliance and adhere to the
following precautions.
IMPORTANT
SAFEGUARDS
READ ALL
INSTRUCTIONS BEFORE
USE AND SAVE FOR
FUTURE REFERENCE
• All components need to
be installed in accordance
with the user manual
instructions for correct
performance of unit.
• This appliance should be
used in conjunction with
a safety switch.
• This appliance is not
intended for use by
persons (including
children) with reduced
physical, sensory or
mental capabilities,
or lack of experience
and knowledge, unless
they have been given
supervision or instruction
concerning use of the
appliance by a person
responsible for their safety.
2
Cli-Mate Recommends
Safety First
6
Components
8
Functions
9
Care & Cleaning
10
Troubleshooting
Contents

3
• Do not operate any
appliance with a damaged
cord or plug or after the
appliance malfunctions, or
has been damaged in any
manner.
• If the supply cord
is damaged, it must
be replaced by the
manufacturer, its service
agent or similarly
qualified persons in order
to avoid a hazard.
• Children should be
supervised to ensure that
they do not play with the
appliance.
• Do not use appliance for
other than intended use.
• Do not disassemble, repair
or re-form the unit, it may
cause injury, fire or other
malfunctions. A qualified
service agent must make
all service adjustments.
Unauthorised
disassembling of the
product will void
the warranty.
• Unplug from outlet when
not in use and before
cleaning. Never plug in
or unplug unit with wet
hands.
• Do not use unit outdoors
or expose to greasy
or damp environments.
• Keep the rear air inlet
and outlet free from air
blocking materials such
as clothing, plastic bags
or papers. Air flow
is required for the unit
to operate effectively.
• Place unit on a flat
location at least 30cm
from wall or other
appliances.
• When the unit is in
operation, keep all body
parts, jewellery, hair and
loose clothing away from
the openings
• Unit must be placed
on a stable flat surface to
reduce possible excessive
vibration and noise.

4
• Keep the unit away
from fire, flammable gas,
combustible products
or vapours, and corrosive
substances.
• Do not operate the unit
without filters.
• When transporting the
air purifier, always hold
the handles on the side
of the unit.
• To protect against
fire, electric shock and
personal injury, do not
immerse cord, plugs,
or appliance in water
or other liquid.
• Do not place on or near
a hot gas, electric burner
or heating appliance.
• Check voltage to be sure
that the voltage indicated
on the nameplate agrees
with your voltage.
IMPORTANT
SAFEGUARDS
FOR ALL
ELECTRICAL
APPLIANCES
• Unwind the power cord
fully before use.
• Do not let the power
cord hang over the edge
of a bench or table, touch
hot surfaces, or become
knotted.
• To protect against electric
shock do not immerse
power cord, power plug
or appliance in water
or any other substance.
• This appliance is not
intended for use by
persons (including
children) with reduced
physical, sensory or mental
capabilities, or lack of
experience or knowledge,
unless they have been
given supervision or
instruction concerning
use of the appliance
by a person responsible
for their safety.

5
• Children should be
supervised to ensure
they do not play with
the appliance.
• It is recommended
to regularly inspect the
appliance. Do not use the
appliance if power cord,
power plug or appliance
becomes damaged in
anyway. Return the
entire appliance to
the nearest authorised
Cli-Mate Service Centre
for examination and/
or repair.
• Any maintenance other
than cleaning should
be performed at an
authorised Breville
Service Centre.
• This appliance is
recommended for
household use only.
Do not use this appliance
for anything other than
its intended use. Do not
use in moving vehicles
or boats. Do not use
outdoors. Misuse may
cause injury.
• The installation of
a residual current
device (safety switch)
is recommended to
provide additional safety
protection when using
electrical appliances.
It is advisable that
a safety switch with
a rated residual operating
current not exceeding
30mA be installed in the
electrical circuit supplying
the appliance. See your
electrician for professional
advice.
WARNING
Fully unwind the cord before use.
FOR HOUSEHOLD USE ONLY
SAVE THESE INSTRUCTIONS

6
Components
A.
Mist Outlet
B.
Leather Tag
A
C
D
C.
Lid
D.
Control Panel

7
Components
CONTROL PANEL
A.
Power Indicator Light
B.
Maximum Mist Output Level
C.
Minimum Mist Output Level
WATER TANK
A.
Water Tank Cover
B.
Water Tank
Note: Water tank shown upside down.
A
B
C
D
E
D.
Power Button
E.
Mist Output Level Button
F.
Light Button
A
B

8
OPERATION INSTRUCTIONS
1. Remove the lid by lifting the leather tag.
2. Take out the water tank.
3. Turn the water tank upside down
and unscrew the water tank cover
(turn it anti-clockwise) and fill
water tank with clean water.
NOTE
Use only clean, cool tap water to fill the water
tank. Do not use hot water. Filtered or distilled
water is recommended to avoid scale build up
if tap water is too hard.
4. Replace the water tank cover. Turn the
water tank back up the right way and
place into the unit. Place the lid back on.
5. Locate a flat, stable location and plug
the power cord into the appropriate
electrical outlet. The Power indicator
light will illuminate red.
6. Switch on the unit by pressing the POWER
button
. The Power indicator light will
illuminate blue and the unit will begin to
work on default setting (MIN mist level).
7. To select MIST LEVEL: Press the Mist
level button
to select between MAX
(maximum) and MIN (minimum).
8. When water level in the water tank is
low, the unit will automatically stop
operation and power indicator light will
flash red. Follow steps 1-4 to continue.
9. Light Option: Push the Light
Button
to switch on/off the light
located underneath the unit.
PRODUCT SPECIFICATIONS
ULTRASONIC HUMIDIFICATION SYSTEM
MODEL CODE
CLI-AH201
POWER SUPPLY
20W
POWER CONSUMPTION
2.5 Litres
WATER TANK CAPACITY
150ml/h
EVAPORATION RATE
Up to 20m2
NOISE LEVEL
10 Hours
Functions

9
Care & Cleaning
• Do not rinse the unit or immerse the unit
in water.
• Do not use detergent to clean any water-
containing parts of the humidifier.
• Do not use abrasive cleaners or brushes
to clean.
• Clean the surface of the device with
a soft cloth.
SCALE
To reduce the possibility of scale (white mineral
deposits) build-up on the surface of the water
basins, inner surface of the water tank and
transducer, the following is recommended:
• Change the water daily.
• If possible, use distilled or demineralised
water.
• Drain, clean and thoroughly dry all parts
of the unit before putting it into storage.
STORAGE
If you do not plan to use the unit for an
extended period of time empty water tank and
base completely. Do not store with water inside
base or water tank. Allow all components to
dry completely before storing. Store in a cool
dry location.
CAUTION:
Before carrying out cleaning or maintenance of the product, always turn off and unplug
the cord from the power socket.
CLEANING THE TRANSDUCER
If mineral deposits are evident on or around
the transducer clean the surface with a soft,
clean cloth and a small amount of undiluted
white vinegar. To remove mineral deposits, put
5-10 drops of undiluted white vinegar on the
surface of the transducer. Leave to soak for 2-5
minutes. Use a cotton swab to gently loosen up
the scale of the surface. Rinse the transducer
with clean water and wipe clean.
IMPORTANT
Be careful not to damage the Transducer
during cleaning. Do not use any metal to
scrape it or touch with bare fingers.
Transducer

10
PROBLEM
POSSIBLE CAUSES
EASY SOLUTION
No Power.
•
Unit is not plugged into
wall socket.
•
Check connection to wall socket.
Little or no mist
is produced.
•
Insufficient water in water tank.
•
Fill water tank.
•
Scale build up on transducer.
•
Clean scale build up as per
instructions.
•
Water is too dirty or kept for
too long in the tank.
•
Clean water tank and refill with
fresh clean water.
•
The mist may not be clearly
visible depending on the balance
between the room temperature
and humidity.
Abnormal noise.
•
Very low water levels
in water tank.
•
Refill water tank.
•
Unit is on an uneven surface.
•
Reposition the unit to a stable
flat surface.
White dust accumulation.
•
Hard water used.
•
Follow instructions on page 9.
Troubleshooting

11
Notes

Breville is a registered trademark of Breville Pty. Ltd. A.B.N. 98 000 092 928.
Copyright Breville Pty. Ltd. 2018.
Due to continued product improvement, the products illustrated/photographed
in this brochure may vary slightly from the actual product.
CLI-AH201 ANZ – A18
Web: www.breville.co.nz
Web: www.breville.com.au
Australian Customers
Phone:
1300 139 798
New Zealand Customers
Phone:
0800 273 845
Breville Customer Service Centre