D. No. 05A4  Version 1.0 

Released on 02/06/2014 

Page1 of 10 

 

Uhlmann & Zacher GmbH

  l  Gutenbergstraße 2–4  l  97297 Waldbüttelbrunn  l  Tel.: +49 931 40672-0  l  E-Mail: contact@UundZ.de  l  

http://www.UundZ.de

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quick Guide 

Valid from Firmware 2.2.14 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

CX6110 Electronic Cylinder 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

Page2 of10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

Table of contents 

1

 

General .......................................................................................... 3

 

1.1

 

Intended use ................................................................................................ 3

 

1.2

 

Safety and operation .................................................................................... 3

 

1.3

 

Disposal ...................................................................................................... 4

 

2

 

Product details ................................................................................. 5

 

2.1

 

CX6110 ...................................................................................................... 5

 

2.2

 

Scope of supply ........................................................................................... 5

 

3

 

Indicators ........................................................................................ 5

 

4

 

Assembly ........................................................................................ 6

 

4.1

 

General points to note ................................................................................. 6

 

4.2

 

Assembly ..................................................................................................... 6

 

5

 

Operation ....................................................................................... 7

 

6

 

Batteries .......................................................................................... 8

 

6.1

 

Changing batteries ...................................................................................... 8

 

6.2

 

Low-power opening ..................................................................................... 9

 

7

 

Technical data ............................................................................... 10

 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

Page3 of10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

1

 

General 

Uhlmann & Zacher GmbH 

(U&Z) does not accept any 

liability for the correctness 

and completeness of the 

information given here. 

Information given in this operating manual is 

subject to change without notice. In such a 

case, all previous information becomes 

invalid. 

Uhlmann & Zacher GmbH does not accept 

any liability for damage resulting from 

erroneous or incomplete information. 
Uhlmann & Zacher GmbH directs you to the 

generally valid ESD protective measures.

 

1.1

 

Intended use 

CX6110 cylinder is intended 

for installation on building 

doors. They should be fitted 

with a corresponding lock 

and fitting. Furthermore, the 

CX6110 cylinder is only meant for locking 

and unlocking doors.

Only the components approved by U&Z 

should be used for installation. The CX6110 

cylinder replaces a standard closing cylinder 

and is not suitable for operating as a knob or 

pressure device.  
The CX 6110 cylinder is intended for 

installation in DIN locks with Europrofil 

cylinders. 
All other uses are prohibited.

 

1.2

 

Safety and operation 

No modifications of any kind 

on the cylinder are permitted 

except those described in the 

manual. 
Installation and battery 

replacement may only be done by trained 

personnel in accordance with this manual. 
This manual should be handed over to the 

user by the person installing the product. 
The cylinders must only be lubricated using 

the special resin-free oil.

The cylinders must not be exposed to paint or 

acids. 
The batteries must not be charged, opened 

or heated. 
Wrong polarity when inserting the batteries 

can cause damage. 
When changing the batteries, change both 

batteries at the same time, even if one battery 

appears to have adequate charge. 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

Page4 of10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

The cylinder must not be used in areas where 

explosions can happen. 
Only use the specified batteries. 
If the batteries or the cylinder heat up above 

the specified storage temperature, then this 

can cause fire and explosion. 
To avoid malfunctioning and damage, use 

only original Uhlmann & Zacher parts and 

accessories. 
However, no liability can be accepted for 

wrongly programmed cylinders. If there are 

disruptions, such as access not possible for 

injured persons, property damage or other 

damages, Uhlmann & Zacher GmbH is not 

responsible. 
Unauthorised modifications and changes in 

the product are not permitted. 
The electronic cylinders must not be used for 

locking emergency life-saving aids (e.g. 

defibrillator, emergency medication, fire 

extinguisher etc). 
 
 

1.3

 

Disposal 

To ensure environmentally 

friendly recycling, the device, 

as well as the packaging 

must be disposed in an 

ecologically friendly manner. 

The packaging is recyclable and should not 

be disposed of in the household waste but 

recycled. 

Batteries 

Lithium batteries are 

needed to make the 

cylinder work. Improper 

use of lithium batteries can 

cause fires and explosions.  

Defective or spent 

accumulators and batteries must be recycled 

according to the European Directives 

2006/66/EG. Please keep up to date on the 

local stipulations for segregation and 

disposal of batteries. Correct disposal will 

protect the environment and people from 

negative consequences. 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 5 of 10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

 

2

 

Product details 

2.1

 

CX6110 

CX6110: 

Clex prime electronic cylinder, 

standard length from 30/30 mm, special 

lengths from 26/35 mm, version for internal 

and external building locking doors 

(depending on the execution), cylinder casing 

nickel-coated brass, for transponder-keys incl. 

forend screws and batteries

 

 

CX6111: 

Clex prime electronic cylinder, basic 

version, like CX6110, but without date/ clock 

time and events memory

 

 

 

 

 

 

2.2

 

Scope of supply 

 

 

 

 

 

 

 

 

 

Electronic cylinder 

CX6110 

 

2x Battery CR2, 3V 

 

Forend screw 

 

3

 

Indicators 

Operation 

Audible signal 

Explanation of icons 

Rest mode 

 

 
Audible signals: 

 

    = long, deep tone 

O = short, high tone 

Begin programme mode 

    O 

End programme mode 

O   

Transponder key not authorised 

 

Battery warning 

O O O O O 

After battery change: 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 6 of 10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

 

4

 

Assembly 

4.1

 

General points to note 

Internal and external handle must be 

screwed on to the door panel such that the 

cylinder can be pushed into the PC hole of 

the lock without using force. Ideally, the 

central axis of the cylinder is at an angle of 

roughly 90 degrees to the door panel. The 

knob must be in contact with the internal 

door furniture, so there should be a distance 

of at least 1 mm between knob and door 

panel. (A) 
The stud dimensions of the lock must be at 

least 55 mm. (B)

 

90°

min. 1mm

             

min. 55mm

 

 

4.2

 

Assembly 

1. 

If present, remove the forend screw and 

disassemble the existing cylinder. 
 
 
 
 

2. 

Push in CX6110 and fasten with forend 

screw. (A+B)  
 
 

Important: 

Immediately after 

assembly, make sure that the 

components move freely. 

 

 

 

 

 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 7 of 10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

 

5

 

Operation 

1. 

Insert authorised transponder key into the 

electronic cylinder. (A) 
 
 
 
 

 

 
 

 
 
 

 

2. 

After reading the transponder key, the 

electronic cylinder engages. (B) 
 
 
 

 

3. 

Turn transponder key and perform the 

closing sequence. (C)

 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 8 of 10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

 

6

 

Batteries 

6.1

 

Changing batteries 

1. 

Push in locking pins using a pointed object 

and at the same time pull out the sleeve. (A) 
 
 
 
 

2. 

Changing batteries (ensure correct polarity). 

(B) 
 
 
 
 

3. 

Push in locking pins and push the sleeve on 

to the knob, until the locking pins latch into the 

designated recesses in the sleeve. (C)

 

 

 

 

+

-

+

-

 

 

 

   

 

 
 

Important: 

Ensure the correct 

alignment of the sleeve 

(pressure spring on the 

negative pole of the battery).

 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 9 of 10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

6.2

 

Low-power opening 

Using the service device CX6510, key adapter cable CX6540 and service key CX6530, the 

electronic cylinder CX 6110 can be powered externally. Hence, the CX 6110 can be opened even 

if the batteries are spent. 

 

Important: 

Always ensure that the battery in the service unit is full. 

 

 

1. 

 

Connect key adapter with service device and 

cylinder. 

2. 

 

Execute the menu item 

Service opening / 

ESC Low power opening 

in the service unit. 

3. 

 

When prompted, hold the service key to the 

front side of the service unit. 

4. 

 

The electronic cylinder connects; the closing 

sequence can be performed. 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 10 of 10 

 

 

 

 

Quick Guide 

Electronic Cylinder 

 

7

 

Technical data 

Product designation 

Clex prime electronic cylinder 

Product number 

CX6110 

Dimensions 

Dimension of the cylinder for Europrofil locks conforming to DIN 

18252 

Cylinder lengths 

From 26/35 mm or 30/30 mm to 70/70 mm in 5-mm steps 

Length of the knob 

40.0 mm 

Diameter of the knob 

40.0 mm 

Power supply 

Battery, 2 pieces, Type CR2 Lithium 3 V 

Battery life cycle 

Up to 50,000 operations or up to 4 years of product life in 

installed state without operations 

Low-Power-opening 

Always possible with the Clex service device 

Operating temperature 

-20 °C to +65 °C 

Storage temperature 

-20 °C to +65 °C 

Installation location 

Internal and building locking doors (knob inside the building area), 

depending on the product version 

Standards 

DIN EN 50081-1 – Issue: 1993-03 

DIN EN 50082-2 – Issue: 1997-11 

RL 2004/108/EG