background image

 

CLETEF-786 

   

 

 

 

 

 

 

Infrared Thermometer 

Instruction Manual 

 

 

 

 

 

 

 

0482 

 


background image

 

Introduction

 

 

 

Thank you for choosing the Clever Choice Duo 

TM

 Ear & Forehead 

Thermometer, by Simple Diagnostics. 

 

The infrared thermometer CLETEF-786 can be used to read body 

temperature by measuring the ear or forehead temperature, and is 

suitable for both adult and children. 

 

NOTE: temperature of children below 3 months cannot be accurately 

measured with the Ear testing mode. 

 

Please read the instructions carefully before using the product, and put it 

in a safe and secure place for future reference. 

 

 


background image

 

Contents 

 

1. The Advantages of Clever Choice Duo

TM

 ............................................. 1 

2. Necessary Safety Instructions

 .............................................................. 2 

3. Product Design

 ...................................................................................... 4 

4. How to Use Forehead Mode

 ................................................................. 5 

5. How to Use Ear Mode

 ........................................................................... 5 

6. Sound and Backlight Information

 .......................................................... 7 

7. Display and Operation Instructions

 ....................................................... 8 

8. Cleaning and Disinfection

 ................................................................... 11 

9. Maintenance

 ........................................................................................ 11 

10. Replacing the Batteries

 ..................................................................... 12 

11. Troubleshooting

................................................................................. 12 

12. Technical Specifications

 .................................................................... 14 

13. After-Sale Service

 ............................................................................. 15 

14. Security Type

 .................................................................................... 15 

15. Authorized European Representative

 ............................................... 15 

16. Symbols

 ............................................................................................. 16 

17. Declaration

 ........................................................................................ 16 

18. EMC Information-Guidance and Manufacture

s Declaration

 ............ 16 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 
 
 
 
 

 

Simple Diagnostics Inc.

 

Address: 

P.O. Box 128   
Williston Park, NY 11596, USA 

Tel (USA): 

877-342-2385 

Tel (Inter.):  1-954-603-0572 
Website: 

www.SimpleDiagnostics.com 

Email: 

Sales@SimpleDiagnostics.com 

 


background image

20 

 

communications equipment and the CLETEF-786 Infrared Thermometer. 
The CLETEF-786 Infrared Thermometer is intended for use in an 
electromagnetic environment in which radiated RF disturbances are 
controlled. The customer or the user of the CLETEF-786 Infrared 
Thermometer can help prevent electromagnetic interference by maintaining a 
minimum distance between portable and mobile RF communications 
equipment (transmitters) and the CLETEF-786 Infrared Thermometer as 
recommended below, according to the maximum output power of the 
communications equipment. 
Rated 
maximum 
output 
power 
of 
transmitter 

Separation distance according to frequency of transmitter m 
150 kHz to 80 
MHz 

 

80 MHz to 800 
MHz 

 

800 MHz to 2,5 
GHz 

 

0.01 

0.12 

0.23 

0.1 

0.38 

0.73 

1.2 

2.3 

10 

3.8 

7.3 

100 

12 

23 

For transmitters rated at a maximum output power not listed above, the 
recommended separation distance d in meters (m) can be estimated using 
the equation applicable to the frequency of the transmitter, where P is the 
maximum output power rating of the transmitter in watts (W) according to the 
transmitter manufacturer. 
 
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher 
frequency range applies. 
NOTE 2 These guidelines may not apply in all situations. Electromagnetic 
propagation is affected by absorption and reflection from structures, objects 
and people. 

 

 

 

1.

 The Advantages of Clever Choice Duo

TM

 

Dual mode (forehead temperature and ear temperature) 
Thanks to dual mode design, you are free to take body temperature 
by detecting the infrared heat given off by the forehead or eardrum, 
The forehead temperature measurement range is from 89.6

 to 

108.0

32

 to 42.2

.The ear temperature measurement range 

is from 32.0

 to 212.0

0

 to 100.0

The product consists of ABS plastics, temperature sensor, Infrared 
temperature measuring element, microcomputer controlled circuit, 
LCD , backlight and buzzer. 
 

Convenient for use 

 

Special ergonomic design to facilitate operation. 

 

No inconvenience would be caused to your daily life. It’s available 
for measurement when your children’s sleeping. 

 

It provides comfortable user experience compared with anus 
thermometer for children, rapid reading and simple operation 
compared with mouth thermometer. 

 

Memory recall 

A maximum of 20 previous readings is available to help you track the 
changes of your body temperature. 

 

Safe and hygienic 

 

Compared to mercury thermometer, there is no danger of 
breaking the glass or swallowing mercury. 

 

It is completely safe for children to use. 

 

Fever warning 

 

After a reading, the backlight will appear green, orange, or red to 
indicate presence and severity of a fever. When the temperature 
is more than or equal to 38.0°C/100.4 , there will be 6 short 
double and half beeps and the reading will flicker with orange 
backlight for 5 seconds. This indicates that you may have a fever. 
Please consult your doctor if you are not sure. If fever is worse, 
the backlight will appear red. 

 

Extensive clinical data of hospital 

The cooperation with designated hospitals is subjected to precise 
clinical verification, with the support of extensive clinical data and 
professional medical experts. 

 


background image

 

Application scope 

The thermometer takes human body temperature for clinical or 
household use. It applies to all age groups and those who are 
suffering from a fever. (Ear temperature mode should not be used for 
children below 3 months) 

 

Operating principle 

The infrared temperature sensor detects infrared energy emitted by 
the eardrum. A built-in lens focuses the collected energy, which is 
converted into a temperature reading by the thermopiles and 
measurement circuits. 
 

 

2. Necessary Safety Instructions 

   

The device is not for use with newborn babies. 

    The device is not a continuous monitoring device. 

    CLETEF-786 is not waterproof. Please do not douse it with water 

or other liquids. Cleaning and disinfection procedure shall be in 
comply with the instructions specified in “cleaning and storage” 

    Please do not use the product if the temperature sensor or the 

infrared thermometer shows any sign of damage. Do not try to 
repair the product if it is damaged. Please contact Simple 
Diagnostics Customer Service. 

    CLETEF-786 consists of precision parts. No replacement shall 

be provided for damage due to intense shock or vibration. Do not 
twist the infrared thermometer and the temperature sensor.   

19 

 

where p is the maximum 
output power rating of the 
transmitter in watts (W) 
according to the transmitter 
manufacturer and d is the 
recommended separation 
distance in meters (m).

b

 

 
Field strengths from fixed 
RF transmitters, as 
determined by an 
Electromagnetic site survey, 
a should be less than the 
compliance level in each 
frequency range.

b

   

 
Interference may occur near 
equipment marked with the 
following symbol: 

 

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. 
NOTE 2 These guidelines may not apply in all situations. Electromagnetic is 
affected by absorption and reflection from structures, objects and people. 
a. Field strengths from fixed transmitters, such as base stations for radio 
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and 
FM radio broadcast and TV broadcast cannot be predicted theoretically with 
accuracy. To assess the electromagnetic environment due to fixed RF 
transmitters, an electromagnetic site survey should be considered. If the 
measured field strength in the location in which the CLETEF-786 Infrared 
Thermometer is used exceeds the applicable RF compliance level above, the 
CLETEF-786 Infrared Thermometer should be observed to verify normal 
operation. If abnormal performance is observed, additional measures may be 
necessary, such as re-orienting or relocating the CLETEF-786 Infrared 
Thermometer. 
b. Over the frequency range 150 kHz to 80 MHz, field strengths should be 
less than 3 V/m. 

Recommended separation distances between portable and mobile 
RF communications equipment and the EQUIPMENT or SYSTEM -
for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING 

Recommended separation distances between portable and mobile RF 

 


background image

18 

 

IEC 61000-4-2 

±8 kV air 

synthetic material, the 
relative humidity should be 
at least 30 %. 

Power 
frequency 
(50/60 Hz) 
magnetic 
field 
IEC 61000-4-8 

3 A/m 

3 A/m 

Power frequency magnetic 
fields should be at levels 
characteristic of a typical 
location in a typical 
commercial or hospital 
environment. 

 
 

Guidance and manufacturer´s declaration – electromagnetic 
immunity –for EQUIPMENT and SYSTEM that are not LIFE-
SUPPORTING 

Guidance and manufacturer´s declaration – electromagnetic immunity 
The CLETEF-786 Infrared Thermometer is intended for use in the 
electromagnetic environment specified below. The customer or the user of 
the CLETEF-786 Infrared Thermometer should assure that it is used in such 
an environment. 
Immunity test 

IEC 
60601 
test level 

Compliance 
level 

Electromagnetic 
environment - 
guidance 

Radiated RF 
IEC 61000-4-3 

3 V/m 
80 MHz 
to 2.5 
GHz 

3 V/m 

Portable and mobile RF 
communications equipment 
should be used no closer to 
any part of the CLETEF-786   
Infrared Thermometer, 
including cables, than the 
recommended separation 
distance calculated from the 
equation applicable to the 
frequency of the transmitter. 
Recommended separation 
distance 

 

 

 

 

 

Operating Conditions

 

Temperature: 10

C to 40

C     

Humidity:    15%-95%RH, non-condensing 
Atmospheric pressure: 86kPa to 106kPa 
 

Storage and Shipping Conditions

 

Temperature: -20

C to 55

C   

Humidity: 0-95% RH, non-condensing 
Atmospheric pressure: 50kPa to 106kPa 
 

Battery Installation

 

Put the two AAA batteries into battery 
compartment in correct polarities. 
Push the battery cover horizontally along the 
arrow to close. 
 

Notes:   

  If you using the thermometer for the first time, please pull out the 

Plastic sheet . 

  Battery polarities should be correct. Otherwise, the device may be 

damage. 

  Please remove the batteries if the thermometer will not be used for a 

prolonged time.   

 

Warnings 

    Please keep this infrared thermometer away from children 

    This thermometer is not a substitute for Medical Assistance 

    The infrared thermometer is not waterproof, Keep it away from 

water. 

 
 
 
 
 
 

 


background image

 

3. Product Design 

 

 

 
(1) Probe cover (put the cover on when using forehead mode) 
(2) Probe (take off the cover when using ear mode) 
(3) Head button 
(4) LCD display screen 
(5) Ear button 
(6) Battery cover 
 
 
 

Display description 

1. Ambient temperature 
2. Ready for measurement 
3. Ear mode 
4. Forehead mode 
5. Temperature unit (

6. Low power indicator 
7. Memory mode 
8. Temperature value 
 

 

 

 

 

17 

 

ACCOMPANYING DOCUMENTS. 

●          Portable and mobile RF communications equipment can affect 

CLETEF-786 Infrared Thermometer 

●          The CLETEF-786 Infrared Thermometer should not be used 

adjacent to or stacked with other equipment. 

Guidance and manufacturer´s declaration – electromagnetic 
emission –for all EQUIPMENT AND SYSTEMS 

Guidance and manufacturer´s declaration – electromagnetic emission 
The CLETEF-786 Infrared Thermometer is intended for use in the 
electromagnetic environment specified below. The customer or the user of 
the CLETEF-786 Infrared Thermometer should assure that it is used in such 
an environment. 
Emissions   
test 

Compliance 

Electromagnetic environment - guidance 

RF emissions 
CISPR 11 

Group 1 

The CLETEF-786 Infrared Thermometer 
uses RF energy only for its internal 
function. Therefore, its RF emissions are 
very low and are not likely to cause any 
interference in nearby electronic 
equipment. 

RF emissions 
CISPR 11 

Class B 

The CLETEF-786 Infrared Thermometer 
is suitable for use in all establishments, 
including domestic establishments and 
those directly connected to the public low-
voltage power supply network that 
supplies buildings used for domestic 
purposes. 

 

Guidance and manufacturer's declaration – electromagnetic 
immunity –for all EQUIPMENT and SYSTEMS 

Guidance and manufacturer´s declaration – electromagnetic immunity 
The CLETEF-786 Infrared Thermometer is intended for use in the 
electromagnetic environment specified below. The customer or the user of 
the CLETEF-786 Infrared Thermometer should assure that it is used in such 
an environment. 
Immunity test 

IEC 
60601 
test level 

Compliance 
level 

Electromagnetic 
environment- guidance 

Electrostatic 
discharge 
(ESD) 

±6 kV 
contact 
 

±6 kV contact 
 
±8 kV air 

Floors should be wood, 
concrete or ceramic tile. If 
floors are covered with 

 


background image

16 

 

W1G9QR,U.K.

 

16. Symbols 

Symbol 

Description 

 

Type BF applied part. 

 

Attention must be paid. 

 

Information about a manufacturer, such as name 
and address. 

 

Please read the instructions carefully. 

 

Waste electrical materials should be sent to a 
dedicated collection point for recycling. 

  Warning 

A personal injury or thermometer damage may occur 
if the thermometer is not correctly used. 

  Attention 

Inaccurate reading or thermometer damage may 
occur if the thermometer is not correctly used. 

 

17.Declaration 

      EMC of this product complies with IEC60601-1-2 standard. 
      The materials which the user can come into contact have no toxicity 
and no action on tissues comply with ISO10993-1, ISO10993-5 and 
ISO10993-10. 

 

 
18. EMC Information-Guidance and Manufacture

Declaration 

   

CAUTION:

 

●          CLETEF-786 Infrared Thermometer needs special precautions 

regarding EMC and needs to be installed and put into service 
according to the EMC information provided for in the 

 

 

4.How to Use Forehead Mode 
■ Rapid measurement 

1. As shown in Figure A, put the cover on the probe, and position the 
thermometer at the center of the forehead, just above the eyebrow. 
Ensure that the thermometer is in contact with the forehead. 
2. Press and release the 

Head

 button. The temperature will be displayed 

on the screen instantly. 

 

 

                  Figure A                                          Figure B 

■ Continuous measurement (more accurate) 

As shown in Figure B, press and hold the 

Head

 button, slide the 

thermometer across the forehead from one temple to the other and then 
release the button. The temperature will display on LCD screen.   

Note: 

During continuous measurement the LCD displays the current 

read temperature value about every 0.5 seconds and then shows the 
maximum temperature value at the end. 
 

5.How to Use Ear Mode 

1. Gently remove the sensor/probe cover to reveal the ear probe. 

 

2. Insert the ear probe into the ear canal. Ensure that the sensor is 
pointer towards the eardrum. 
3. Press and release the 

Ear 

button. The temperature will be displayed 

on the screen instantly. You can take another measurement when the 
backlight is off.

 

 

 


background image

 

 

 

Note: 

Children under 1 year: Pull their ear straight back. 
Children aged 1 year to adult: Pull the ear up and back. 

 

 

 
To Avoid Inaccurate Readings:

 

1. 

Make sure that there is no dirt in or on the temperature sensor 

2. 

Use the device indoors, or with no strong winds. 

3. 

Make sure there is no sweat on the forehead. 

4. 

Make sure the ear canal is clean. 

5. 

Hold still and keep calm during measurement. 

6. 

If Clever Choice Duo

TM

 is moved to an area with a different 

ambient temperature, wait 30 minutes before testing. 

7. 

If the patient moves to a room with a different ambient 

temperature, it is suggested to wait at least 10 minutes to test. 

8. 

Do not hold the unit for too long, as it is highly sensitive to heat. 

 

 

15 

 

Low-battery Alert 

The low-battery symbol is displayed if the power 
voltage is lower than 2.51 V±0.15V. 

Automatic Power-off 

The thermometer automatically powers off if it is not 
used within 10±1 seconds. 

Outer dimensions 
(mm) 

146.5×40×52.4 

Weight (g) 

Thermometer (with batteries): 85.0 g 

Liquid Ingress 
Protection 

IPX0 

The date of 
production 

See the label 

Life 

5 years 

The infrared thermometer has been tested and conforms to the standard 
ASTM E1965-98. ASTM laboratory accuracy requirements in the display 
range of 96.8°F to102.2°F (36°C-39°C) for ear canal IR thermometers is 
±0.4°F (±0.2°C) and for skin IR thermometers is ±0.5°F (±0.3°C). Note 
that for mercury-in-glass and electronic thermometers, the requirement 
per ASTM Standards E667-86 and E1112-86 is ±0.2°F (±0.1°C). 

 

13. After-Sale Service 

The device is under warranty for one year since the date of acquisition. 
Application for repairing should be presented during the warranty period. 
The damage caused by improper use is not under warranty scope. 
Batteries and packaging are not under warranty scope as well. 
 

14. Security Type 

Anti-electric shock type: internally powered equipment. 

Anti-electric shock degree: 

  Type BF applied part. 

 

15. Authorized European Representative 

 
Wellkang Ltd 
Suite B, 29Harley Street, LONDON, 

 


background image

14 

 

12. Technical specifications 

 

Product Name 

Clever Choice Duo

TM 

Infrared Thermometer 

Product Model 

CLETEF-786 

Applicable standard  ASTM E 1965/EN 12470-5 

Power Supply Mode  Internal power supply 

Operating Voltage 

DC 3V 

Battery Model 

AAA x 2 

Battery Life 

Alkaline dry battery for around 20,000 measurements 

Operating Mode 

Continuous operating 

Display 

Segment LCD 

Measure time 

About 1 second 

Latency Time 

About 3 second 

Measuring Range 

Ear temperature:0.0°C–100.0°C (32.0°F–212.0°F) 

Forehead temperature:32.0°C–42.2°C (89.6°F–
108.0°F) 

Accuracy 

(Laboratory) 

Ear temperature 

±0.2°C (±0.4°F) from 36.0°C-39.0°C/96.8°F-102.2°F 

±0.3°C (±0.5°F) from 32.0°C-35.9°C/89.6°F-96.7°F 

±0.3°C (±0.5°F) from 39.1°C-42.2°C/102.3°F-108.0°F 

Forehead temperature 

±0.3°C (±0.5°F) from 32.0°C-42.2°C/89.6°F-108.0°F 

Resolution 

0.1°C (0.1°F) 

Memory 

20 temperature readings 

 

6. Sound and Backlight Information

 

 

No. 

Range 

Sounds 

Backligh

Meaning 

Ear temperature mode

 

0-37.4

 32.0

-

99.4

 

a long beep 

Green 

Acceptable 

37.5

-37.9

 

99.5

-100.3

 

a long beep 

Yellow 

Elevated 

38.0

-100.0

 

100.4

-212.0

 

6 short double and 

half beeps 

Red 

Possible 

high fever 

Forehead temperature mode 

32.0 -37.4  
89.6 -99.4  

a long beep 

Green 

Acceptable 

37.5 -37.9  

99.5 -100.3  

a long beep 

Yellow 

Elevated 

38.0 -42.2  

100.4 -108.0  

6 short double and 

half beeps 

Red 

Possible 

high fever 

 

Notes: 

1. 

When the temperature is less than or equal to 37.4°C/99.4 , 
there will be a long beep with green backlight. This indicates that 
the temperature is normal. 

2. 

When the temperature is between 37.5°C/99.5  to 
37.9°C/100.3 , there will be a long beep with yellow backlight for 
3 seconds. This indicates that the temperature is a little high. It 
should be noted. 

3. 

When the temperature is more than or equal to 38.0°C/100.4 , 
there will be 6 short double and half beeps and the reading will 
flicker with red backlight for 5 seconds. This indicates that you 
may have a fever. Please consult your doctor if you are not sure. 

 
 
 

 


background image

 

7. Display and Operation Instructions 

Screen 

Display 

Operating Instructions 

Displayed State 

Sound and backlight 

Measuring Forehead Temperature 

 

 

 

Position the thermometer at the 
center of the forehead above the 
eyebrow. With the thermometer 
touching the forehead, press and 
release the 

Head

 button. The 

temperature will be displayed on 
the screen. You can also press 
and hold the 

Head

 button to 

measure temperature 
continuously. 

See the table of 

“Sound and Backlight 

Information” 

Measuring Ear Temperature 

 

 

 

Insert the thermometer ear probe 
into the ear canal. Press and 
release the 

Ear

 button. The 

temperature will be displayed on 
the screen.   

See the table of 

“Sound and Backlight 

Information” 

Out of Range Display 

 

The measured value exceeds 
212 °F/100°C in ear temperature 
mode. The measured value 
exceeds 108.0 °F/42.2°C in 
forehead temperature mode. 

3 short beeps with red 

backlight for 3 

seconds. 

 

The measured value falls below 
32.0°F/0°C in ear temperature 
mode. The measured value falls 
below 89.6°F/32.0°C in forehead 
temperature mode. 

3 short beeps with 

green backlight for 3 

seconds. 

13 

 

"ErC" is displayed. 

This error occurs 

when data is 

being read from 

or written into the 

memory, or the 

temperature 

correction is not 

complete. 

Contact us. 

The temperature 

reading is lower than 

the typical body 

temperature range. 

The lens of the 

temperature 

probe is dirty. 

Clean the lens using a 

cotton swab. 

The distance 

between the 

temperature 

probe and the 

target is too large. 

Move the thermometer 

closer to the target. 

The thermometer 

was used within 

30 minutes of 

being in a cold 

environment. 

Wait 30 minutes after the 

thermometer has been 

moved into the current 

ambient temperature. 

The temperature 

reading is higher than 

the typical body 

temperature range. 

The temperature 

probe is faulty. 

 

Contact us. 

 

 

 


background image

12 

 

"Cleaning and Disinfection". 

2. 

Store the thermometer in a dry, dust-free, and well-ventilated 

place. Ensure that the thermometer is not exposed to sunlight. 

Ensure that the storage and transportation environments meet 

these requirements 

3. 

Check whether safety risks exist on a regular basis. 

4. 

Remove the batteries if the thermometer will not be used for more 

than two months. 

 

10. Replacing the Batteries 

1. 

Slide the battery cover off along the marked direction. Put two 
AAA batteries correctly into the compartment. 

2. 

Remove the batteries if the thermometer will not be used for more 
than two months. 

 

11.Troubleshooting 

Symptom

 

Possible Cause

 

Solution

 

The thermometer fails 

to power on. 

The batteries are 

dead 

Replace the Batteries 

(AAAx2) 

Polarities of the 

batteries are 

reversed. 

Ensure that the batteries 

are correctly installed 

based on the polarity 

symbols in the battery 

compartment. 

The thermometer 

is faulty. 

If the warranty period has 

not expired, contact us. 

Only the battery 

symbol is displayed. 

The battery level 

is low. 

Replace the Batteries 

(AAAx2) 

"Er1" is displayed. 

The ambient 

temperature is out 

of range (less 

than 10°C/50°F or 

greater than 

40°C/104°F). 

Move to an ambient 

temperature between 

10°C/50°F and 

40°C/104°F. 

 

Screen 

Display 

Operating Instructions 

Displayed State 

Sound and backlight 

Accessing Reading Memory 

 

In the power-off state, press and 
hold the 

Ear 

button for 3-5 

seconds to enter the recall mode. 
"

- - - M

" is displayed. 

silence 

 

 

 

 

 

 

 

Press and release the 

Ear 

button, 

1

 will be shown, followed by the 

recorded reading.   

Press the 

Ear 

button again for the 

next recorded data. 

2

 will be 

shown, followed by the recorded 
reading. 

A maximum of 20 temperature 
readings can be recalled. 

1

 represents the newest data. 

silence 

 

If no temperature reading has 
been taken, only "

- - - M

" will be 

displayed. 

silence 

Clear Memory 

 

In the power-off state, press and 
hold the 

Ear

 button for more than 8 

seconds to enter the 

Clear All 

Memory

 mode. Release the button 

and records will be cleared. 

A long beep without 

backlight 

 


background image

10 

 

Screen 
display 

Operating Instructions 

Displayed State 

Sound and backlight 

Switching between ºF/ºC 

 

 

 

In power-off state, press and hold 
the 

Ear 

button for 6-7 seconds to 

enter the temperature switching 
mode. "

ºC

" or "

ºF

" are flashing. 

Press the 

Ear 

button to switch 

between ºC and ºF.The 
thermometer shut down after 6 
seconds, set up successfully. 

silence 

Error information & low battery

 

 

 
The ambient temperature is higher 
than 40.0ºC (104.0ºF) or lower than 
10.0ºC (50.0ºF). 

3 short beeps and 
yellow backlight for 3 
seconds. 

 

An error occurs when data is being 
read from or written into the 
memory, or the temperature 
correction is not complete. Please 
contact your supplier. 

3 short beeps and 
yellow backlight for 3 
seconds. 

 

When the battery voltage is lower 
than 2.51V ± 0.15V, the low battery 
symbol will appear on the display 
after turning the device on. Please 
replace the batteries. 

silence 

Power Off Mode 

In any mode, if no operation for 10 seconds, the thermometer will power 
off automatically. 

 
Attention: 

   

You must wait for the backlight to turn off before measuring 

again.

 

    Electromagnetic interference: contains sensitive electronic 

11 

 

components and should not be used in the presence of large 
electromagnetic interference, (such as near mobile phones and 
microwaves) 

    Please dispose of the product and batteries in accordance with 

local regulation requirements. 

 
 

8. Cleaning and Disinfection 

Cleaning 

1. 

Clean the temperature probe with 
a soft cloth. Clean the lens of the 
temperature probe with a cotton 
swab. 

 
2. 

Wipe the thermometer body with a 
slightly damp soft cloth, and gently 
dry the body with a piece of tissue 
paper. 

 

    Keep water off the lens during the cleaning process. Otherwise, 

the lens may be damaged. 

    The lens may be scratched if it is cleaned with a piece of tissue 

paper, resulting in inaccurate readings. 

    Do not clean the thermometer with corrosive cleansers. During 

the cleaning process, do not touch the lens using hard objects, 
immerse any part of the thermometer into liquid, or allow liquid to 
enter the thermometer. 

Disinfection 

1. 

Disinfect the thermometer body and the area around the 
temperature probe with a cloth slightly moistened with 75% 
medical alcohol. 

    Do not use hot steam or ultraviolet radiation for disinfection. 

Otherwise, the thermometer may be damaged or age quickly. 

 

9. Maintenance 

1. 

After each use, clean the temperature probe as described in