background image

CLEVER

ear and forehead thermometer

User’s Manual

ver. 1.0

2007/10

 


background image

 


background image

2

►As with any thermometer, proper technique is crucial 

to getting accurate temperature readings. Please 

read this manual thoroughly and carefully before 

using. 

►Always store the thermometer in a cool and dry 

place:  temperatures  between  -4ºF(-20ºC)  and 

122ºF(50ºC); relative humidity less than 95%. Avoid 

direct sunlight.

►Avoid dropping the thermometer from a height or 

strongly hitting it with a hard object. 

►Do not touch the lens. 
►Do not disassemble the thermometer.
►Basic safety precautions should always be observed, 

especially when the thermometer is used on or near 

children and disabled persons. 

►The use to this thermometer is not intended to be a 

substitution to consulting your physician.

The forehead temperature is served as a reference 

only. It cannot be a judgment on fever.

CAUTIONS & WARNINGS

 


background image

This thermometer is clinically proven to produce 

accurate  temperature  measurements.  However, 

please  be  advised  if  you  have  the  following 

situations:
►The accuracy cannot be ensured for a person who 

has deformity in the ear such that the thermometer 

probe cannot be properly inserted into the ear 

canal. 

►The accuracy cannot be ensured when blood or 

drainage is found in the ear canal. 

►Take temperature from the other ear if ear drops or 

medications have been placed in an ear. 

► For a person who wears ear plug or hearing aid, 

remove the device and wait for 15 minutes before 

taking temperature.

RESTRICTIONS OF USE

Never try to clean inside the ears. You may accidentally 

damage  the  ear  drum  or  its  surrounding  tissues. 

Remove excess ear wax only when you can reach it 

with a clean cloth. Consult a physician if you suspect 

the presence of excess ear wax.

NOTE

 


background image

4

INTRODUCTION

HOW DOES IT WORK

NOTE

Thank  you  for  choosing  Clever  Ear&  Forehead 

Thermometer. 
This innovative medical device leverages on advanced 

infrared  (IR)  technology  to  measure  temperature 

instantly and accurately in two convenient ways: in the 

ear or on the forehead. An additional function is while 

resting on a table, an elegant clock displaying room 

temperature  will  be  presented.  Set-up  with  a  color 

LCD backlight, Clever is an elegantly designed infrared 

thermometer meant for your family.

The thermometer measures the infrared heat generated 

by  the  eardrum  and  its  surrounding  tissue,  or  the 

forehead skin surface over the temporal artery. The 

thermometer then converts it into a temperature value 

shown on LCD.

The thermometer does not send out any infrared signal.

 


background image

5

HIGHLIGHTED FEATURES

►Provide two body temperatures: ear or forehead. 

►Fast and accurate: meet the accuracy requirement 

specified in ASTM E1965-98.

►Non-contact measurement that is no lens filter 

required, thus saving cost of replacement.

►Clock and room temperature inter-display.

►A splash-proof probe that can be wiped using a 

clean cloth slightly damped with alcohol or water.

►Automatically power down or back to the CLOCK/

RT mode if left unused over 30 seconds. 

►Big cool button improves handling and activation. 

►Nice backlight improves visibility especially in a 

dark environment.

►Memory  recall  function  allows  you  to  check 

previous results up to 20 measurements.

 


background image

6

M

Clever Ear & Forehead
Thermometer

 


background image

7

Lens

 


background image

8

 


background image

9

SET TIME & UNIT

You will need to set time and unit fo

first-time use o

r

after replacing the battery

.

Step1  Press the Set Button.

"   " and the flashing hour appear first.

Step2  Set hour&minute

Press the On/Scan button  to select  the 

correct hou

r.

Press  th

Set  button  and t h

f lashing

minute then appears.

Press the On/Scan button to select the correct minute.

Press the On/Scan button to select

.

Setting is all completed.

 Select either of the following

two modes to exit setting.

OFF mode: Just leave the meter without pressing. It

will be automatically off after 30 seconds.

CLOCK/RT mode: Press the Set button after Step3.

Without pressing any buttons over 3

0

seconds, the

mete

r

will automatically turn off

.

NOTE

Set button

Step4  Select Beeping sound

Press the On/Scan button to select on/

off the Beeping sound.

Step5   Select LCD backlight

Press the On/Scan button to select on/

off the LCD backlight.

Step3  Select °F or °C

Press the On/Scan button and °F/°C is 

displayed next.

 


background image

10

NOTE

Although the meter works when "  " appears, we still 

recommend that you change the battery to obtain an 

accurate result.

 


background image

11

The body temperature can vary with the individual. It 

also varies at different parts of the body and different 

time  of  the  day.  The  following  table1  shows  the 

statistical normal ranges from different sites. Please 

keep in mind that temperatures measured from different 

sites, even at the same time, should not be directly 

compared.

Fever means that the body temperature is higher than 

normal. This symptom may be potentially caused by 

infection,  overdressing  or  immunization.  But  some 

people may not undergo fever even when they are 

ill. These include, but are not limited to, infants not 

more than 3 months old, persons with compromised 

immune systems, persons taking antibiotics, steroids 

or antipyretics (aspirin, ibuprofen, acetaminophen), or 

persons with some chronic illnesses. Please consult 

your physician when you feel ill even if there is no fever. 

1. Chamberlain, J. M. Terndrup, T. E., New Light on 

    Thermometer Readings,Contemporary Pediatrics, 

    March 1994.

Body Site

Normal Temperature Range
95.9°F - 99.5°F (35.5°C - 37.5°C)

Axillary(underarm)

Oral

Rectal
Ea

r

94.5°F - 99.1°F (34.7°C - 37.3°C)
97.9°F - 100.4°F (36.6°C - 38.0°C)
96.4°F - 100.4°F (35.8°C - 38.0°C)

 


background image

12

NOTE

M

M

M

The meter does not require any costly lens filters. 
The meter will automatically return to its initial mode 

(OFF  or  CLOCK/RT)  if  left  without  use  over  30 

seconds.

 


background image

1

Ear Temperature Taking Hints

1. As with any type of thermometer, you may observe  

   slight variations in consecutive measurements. It is 

   recommended that you take 3 temperature readings 

   

and use the highest one for the following situations:

   Infants not more than 3 months old. 
   Children not more than 3 years old and have a 
   compromised immune system and the presence/
   absence of fever is critical. 
   When you are learning to use the thermometer.
2. Please free from the following situations at least for 
    15 minutes before taking a reading. 
    When you have your ear covered. 

   

 After exercising, swimming, or taking a bath. When 

    expose to extreme temperature 
    During eating and talking.
3.To take accurate readings, the ear must be free from 
   excess ear wax buildup. 
4. Please wait at least for 1 minute before next readings 
    because consecutive measurements will increase the 
    ear canal surface temperature.

 


background image

14

NOTE

As the forehead temperature is likely to b

affected by 

sweat, oil and the surroundings, the reading

 

shall be

 

taken as a reference only.

If the probe is placed at an angle on the forehead, the 

reading will be affected by surrounding temperature.

You can scan at 3 cm distance from the forehead.

Flat

M

Step2

  Press and hold the 

            On/Scan button. Put 

            the probe on the 

            temple. Make sure the 

            probe is flat on the 

            temple, not at an 

            angle.

 


background image

15

 


background image

16

TURN OFF THE DEVICE

After measurements, the meter will back to its initial 

mode after unused over 30 seconds. That is, if the meter 

is started from the OFF mode, it will be automatically 

off after measurements. Likewise, if the meter is started 

from the CLOCK/RT mode, it will be back to that mode 

after measurements.

To exit the CLOCK/RT mode, you have to turn off the 

thermometer.

To turn the thermometer off, press the Set button until 

the hour or minute is blinking. Leave for 30 seconds 

without pressing any button. The thermometer is then 

automatically off. 

 


background image

17

RECALL THE MEMORY

Your  thermometer stores 

20

recent

r

eadings in  th

e

memory. B

e

sure the thermometer is in either "OFF" o

r

"CLOCK/RT" mode before recall.

Step1

  Press the M button to enter

  the memory

.

Each time you press the M

button, a

 r

esult will be displayed

in the order of dates (latest result 

shown first  together with M and

numbe

( from 0 to 19).

When the  memory is  full,  the

oldest result is deleted as the

new one added.

Step3

Step2

  Press the On/Scan button to exit the memory

.

  Press the M button to review

  the result.

When  using the thermometer at first t ime, numbe

of

memory  will f lash

I t indicates that t h

er

e a

re

no  test

results in memory

.

NOTE

 


background image

18

CARE & CLEANING

Keep the probe clean, as build-up of ear wax and 

grease may affect the measurement. 

The probe is splash-proof and can be wiped by a 

clean cloth damped with water or alcohol. 

The body of the thermometer is not water-resistant. 

Please never put the thermometer under a running tap 

or submerge it into water. Use a soft and dry cloth to 

clean it. Do not use abrasive cleaners.

Store the thermometer in a cool and dry location. 

Please  be  free  from  dust  and  away  from  direct 

sunlight.

 


background image

19

Message

What it means

Room temperature falls

outside the operating 

range.

Battery is low and "    " 

is shown on LCD.

What to do

Put the thermometer under

operating temperature range of

41°F to 104°F (5°C to 40°C) at 

least for 20 minutes

.

Please change to a new

battery as soon as possible.

Temperatur

e

measurement falls

outside the displayed 

temperature range:

32-122°F (0-50°C)

Please follow this manual to

take a reading again.

Message

What it means

When the measurement is below 100.4°F(38°C), 

    is shown together with the result.

When the measurement is equal or over 100.4°F(38°C) ,

 Hi  is shown together with the result.

 


background image

20

SPECIFICATIONS

The specification may be changed without prior notice.

Dimensions

Weight

Displayed temperature range

Display resolution

Accuracy

Temperature unit

Operating temperature range 

Operating humidity

Storage temperature range 

Storage humidity

Memory capacity

105mm(L) x 32mm(W) x 35mm(H)

45g

(0°C to 5

0

°C)

2

°F to 12

2

°F

0.1

°C

/0.1

°F

Meet the accuracy requirement specified

 

in ASTM E1965-98

   (±0.

2

°C

±0.4°F

) for the range of 96.8°F 

°C

or

°F

(5°C to 4

0

°C)

41°F to 104°F

95% RH or less

(-2

0

°C to 5

0

°C)

-4°F to 122°F

95% RH or less

20 measurements 

to 102.2°F

 

(36.

0

°C to 39.

0

°C)

±0.5°F(±0.3°C) from 34 to 35.9°C and

 

from 39.1 to 42.2°C

 


background image

21

WARRANTY

1

.Simple Diagnostics warrants this product  to be free of defects 

in workmanship and materials for a period on TWO years 

from the date of purchase. 

2

.During the warranty period, if this product is found to be 

defective,  you  may  bring  it  together  with  the  purchase 

receipt  and  Warranty  Certificate  on  a  carry-in  basis  to 

Simple Diagnostics’s office during normal business hours 

for warranty service. We will then repair or replace defective 

parts or exchanging the whole product as we may choose, 

at  no  charge  to  the  original  owner. After  such  repair, 

replacement or exchange, the product will be warranted from 

the date of purchase. 

.This warranty is valid only if the Warranty Certificate and 

Warranty Registration Card are duly completed with date 

of purchase, serial number and dealer’s stamp, and if the 

Warranty Registration Card is sent to Simple Diagnostics’s 

office not later than 14 days from the date of purchase.     

4.This warranty is void if this product has been repaired or 

serviced by unauthorized person. This warranty does not 

cover defects caused by misuse, abuse, accident, tampering, 

lack of reasonable care , fire or any other acts beyond human 

control. 

5.Except as stated in the above paragraphs, Simple Diagnostics 

disclaims all other warranties, implied or expressed, including 

the warranties of merchantability of fitness for a particular 

purpose  with  respect  to  the  use  of  this  product.  Simple 

Diagnostics shall not be liable for any direct, consequential or 

incidental damages arising out of the use or inability to use 

product.

 


background image

NOTES

 


background image

NOTES