background image

Order codes:  

CRAM17 - MA 4060MP

CRAM18 - MA 4120MP

4 Zone Mixer Amplifier series 

with MP3 & FM Tuner

User Manual

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

2

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available voltage is between  

240V, 50Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  WARRANTY: One year from date of purchase.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

3

Product overview & technical specifications

The MA 4060MP and MA 4120MP are fully featured, professional mixer amplifier with full onboard zoning 

facilities. This mixer amplifier features onboard MP3 (SD/USB) player and FM tuner complete with four zone output 

selection. Each input can be easily routed to any of the four zone outputs using the front panel selector, moreover 

each input features bass, treble and volume control for precise sound control. Three combo mic/line inputs with 

selector and phantom power, via XLR/6.35mm jack. Two phono line inputs, built-in MP3 player on front panel, one 

telephone input and one RJ45 port for a remote paging microphone PM 600. Up to six PM 600 microphones can 

be cascaded from each amplifier with simple easy connection via standard CAT5 cable.

• All source inputs can be matrix assigned to the 4 zone 

outputs simultaneously

• The 5 inputs channels plus onboard MP3 player and FM 

tuner

• Three microphone/line inputs with bass, treble, volume and 

gain control

• Two AUX phono inputs with bass, treble, volume and gain 

control

• MP3 player with SD and USB inputs
• 4 zone remote paging microphone input via RJ45 (requires 

CRMIC06 paging microphone)

• Versatile loudspeaker outputs for each four channels:  

70V, 100V and 4-16Ω

• Line level, balanced outputs for each zone output
• RS232 serial control port for third party system 

communication

• Priority input to override other inputs
• Input priority level from high to low: remote mic, priority 

input and telephone input and MIC 1

• Output for monitor loudspeaker, 1W, 8Ω
• Extensive protection including thermal, short-circuit, clip 

and overload with indicators

• Ground lift switch
• Fan cooled

4 Zone Mixer Amplifier series

Specifications

MA 4060MP

MA 4120MP

Power output

4 x 60Wrms

4 x 120Wrms

Speaker output

70V, 100V, 4Ω

70V, 100V, 4Ω

Monitor output

1W/8

1w/8

Input sensitivity & impedance

CH1/2/3: ±2.5mV/600

, 175mV/10k

, balanced input

CH5/6: 350mV/10k

, balanced input

TEL: 350mV/10K

Remote MIC: ±837mV/10k

CH1/2/3: ±2.5mV/600

, 175mV/10k

, balanced input

CH5/6: 350mV/10k

, balanced input

TEL: 350mV/10K

Remote MIC: ±837mV/10k

Tone

Bass: ±10dB at 100Hz, Treble: ±10dB at 100Hz

Bass: ±10dB at 100Hz, Treble: ±10dB at 100Hz

SNR

≥65dB

≥65dB

Line 1-4 output level

1V/600

 (balanced output)

1V/600

 (balanced output)

Frequency response

80Hz-16kHz

80Hz-16kHz

MP3

Supports MP3 format, max. capacity: 32GB

Supports MP3 format, max. capacity: 32GB

Recording format

WAV

WAV

SD file system

FAT16 or FAT32 root folder is read only, the player does not 
support multiple folders

FAT16 or FAT32 root folder is read only, the player does not 
support multiple folders

Harmonic distortion

≤1%

≤1%

Power consumption

375W

750W

Power supply

240V AC 50Hz

240V AC 50Hz

Dimensions

132 x 484 x 440mm

132 x 484 x 440mm

Weight

9.4kg

13.5kg

Order code

CRAM17

CRAM18

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

4

Panel & connection identification

01 - Mute button and indicator
02 - Input routing
03 - Monitor output level indicator
04 - Monitor volume control
05 - Zone amplifier level indicator
06 - Zone monitor selector button
07 - Zone amplifier output volume 

control

08 - On/off power switch
09 - MP3/FM Tuner, with USB & SD 

card slot

10 - CH1 volume control
11 - CH1 low-pitched tone control
12 - CH1 high-pitched tone control

13 - Power indicator
14 - IEC in socket
15 - Telephone DIP switch and volume 

control

16 - CH5 line signal input and signal 

gain control

17 - CH4 line signal input and signal 

gain control

18 - CH3 microphone signal input and 

signal gain control

19 - CH2 microphone signal and signal 

gain control

20 - CH1 microphone signal and signal 

gain control

21 - Remote microphone input port

22 - RS232 port
23 - LINE, PHANTOM, MIC signal input 

selector switch

24 - Vents
25 - Ground lift switch
26 - Monitor output port
27 - Short circuit priority
28 - Telephone signal input port
29 - Radio antenna port
30 - Zone 1 balanced line level signal 

output

31 - Zone 1 output terminals (COM, 4

70V and 100V

In the box: 

1 x unit,  

1 x power cable,  

FM antenna &  

1 x user manual

1

3

5

4

7

8

6

9

1

11

10

12

13

2

2

ZONE1

ZONE3

ZONE2

ZONE4

LINE

 

OUT

LINE

 

OUT

LINE

 

OUT

LINE

 

OUT

BAL

. / 

UNBAL

.

BAL

. / 

UNBAL

.

BAL

. / 

UNBAL

.

BAL

. / 

UNBAL

.

G

G

G

G

100V

100V

100V

100V

OUTPUT

OUTPUT

OUTPUT

OUTPUT

70V

70V

70V

70V

4

4

4

4

COM

COM

COM

COM

~240V  50Hz  800W

T8AL  250V

L

L

R

R

LINE

PHANTOM

PHANTOM

PHANTOM

LINE

LINE

LINE

MIC

MIC

MIC

ZONE

TEL.

VOLUME

GAIN

GAIN

GAIN

GAIN

GAIN

CH 1

CH 2

CH 3

CH 4

CH 5

REMOTE MIC INPUT

RS232

1W

8

T

MONITOR

PRIORITY

FM ANT

G

R

TEL.PAGING

LIFT GND

14

24

21 22 23

25

15

16

17

18

19

20

26 27

29

28

30

31

Mute priority: MIC 1 highest priority ≥ telephone ≥ remote MIC. The telephone and 

MIC 1 priority can be reset via the rear panel short circuit terminals. Usually MIC 1 

has the highest priority.

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

5

Rack installation

Rack Installation

The MA Series are rack mountable. The rack you use should be a Double Door Rack where you can open the front 

and rear panel. When mounting the amplifier into the rack, please make sure that there is enough space around 

the amplifier.  

 

Be careful when mounting the amplifier into the rack. Put the heaviest products into the lower part of the rack. 

 

The front panel is not designed to absorb acceleration forces occuring during transportation.  

 

Inputs

Short cables runs improve the sound quality remarkably. Input cables should be short and direct, since high 

frequencies will mostly be absorbed if the cables are unnecessarily long. Besides that a longer cable may lead to 

humming and noise problems. If the cable runs are unavoidable, you should use balanced cables. 

 

Outputs

The high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long and thin cables 

used for low impedance (4-16Ω) speakers will influence the damping factor and thus the low frequencies in a 

negative way. In order to safeguard good sound quality, the damping factor should lie around 50. The longer a 

cable has to be the thicker it should be. For longer cable runs please ensure the 100V outputs are used for 100V 

speakers. 

 

Connect your speaker systems via the speaker terminals (COM = -VE)  

 

Examples:  

1) COM + 4-16Ω

      

 

2) COM + 70V

    

 

3) COM + 100V 

 

Note: Please do not use more than one pair of output terminals on any one output zone.

 

 

Connections To The Mains

 

 

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the available supply 

is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be connected at all times. DO 

NOT remove or disconnect the earth..

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

6

Operation instructions

Initial Start Up Procedure

•  

Reset all “Level” or “Volume” controls to the “0” position on the front panel. Reset the BASS and TREBLE  

   

controls to the centre point.

•  

Reset CH1 thru CH5 gain controls & TEL level control on the rear panel to the “0” position.

•  

Connect the audio sources & mains power input.

•  

Switch on the amplifier using the mains switch on the front panel. The LED indicator (13) will illuminate  

   

BLUE if the amplifier is ready for use and working correctly, if the indicator illuminates RED this indicates  

   

the amplifier is under PROTECT status.

•  

Adjust CH1 thru CH5 gain controls to match the input signal levels between different sources

CH1 to CH5 Operation (note: CH1 thru CH5 feature the same operation)
1) 

BASS control:

 BASS control offers tonal adjustment for the low frequency, turn  

   

clockwise to increase and anti-clockwise to decrease.

2) 

TREBLE control:

 TREBLE control offers tonal adjustment for the high frequency, turn  

   

clockwise to increase and anti-clockwise to decrease.

3) 

VOLUME (LEVEL) control:

 VOLUME (LEVEL) control offers adjustment for the    

   

corresponding input channel, turn clockwise to increase and anti-clockwise    

   

to decrease to reduce the volume.

4) 

MUTE button:

 Each channel input (CH1 thru CH5) may be muted by pressing the  

   

MUTE button. The button features LED illumination when muted.

5) 

Z1 to Z4 Zone Selector buttons:

 Each of the CH1 to CH5 input channels can be  

   

routed to any combination of the four output zones. The zone selector buttons   

   

feature LED illumination, the LED will illuminate if the zone is selected.

6) 

VOLUME (LEVEL) control: 

VOLUME (LEVEL) control offers adjustment for the    

   

corresponding output channel, turn clockwise to increase and anti-clockwise to  

   

decrease to reduce the volume.

7) 

MON button:

 The MA 4060MP and MA 4120MP amplifiers both feature a Monitor  

   

output function for status confirmation purposes. Select the MON button on the  

   

desired channel to activate the Monitor function. The Monitor output features a  

   

Volume (Level) control.

8) 

Output VU Meter:

 Each of the five outputs (Z1 to Z4 and MON) feature LED VU  

   

meter plus CLIP and PROTECTION status indicators. The CLIP LED will illuminate to  

   

indicate when the audio signal is too high, in this instance reduce the VOLUME by  

   

turning the volume control anti-clockwise. The PROTECT LED will illuminate if the  

   

amplifier detects a fault or a problem with the output circuit.

Z2

Z4

TREBL E

+10

MON

7

8

7

8

MUTE

Z1

Z3

LEVEL

CH 2

BASS

-10

-10

+10

ZONE 1

LEVEL

0dB

PROT

CLIP

-5

-10

-15

0

1

2

3

4

5

6

10

0

1

2

3

4

5

6

10

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

7

MP3 Player / FM Radio Operation:

POWER:

 The onboard MP3 Player & FM radio may be powered up or down independent of the main amplifier. 

Press the power switch to power on or power off the MP3/FM Radio.

MODE:

 Press the mode button to select FM Radio, SD Card or USB.

PP/SCAN:

 The FM radio tuner features automatic tuning, press the PP/SCAN button to activate the scan function.

NEXT:

 Press the NEXT button to skip music tracks next when using the SD Card or USB.

PREV:

 Press the PREV button to skip music tracks previous when using the SD Card or USB.

EQ:

 Press the EQ button to adjust the equaliser settings for the SD Card/USB or FM Radio.

VOL +:

 Press the VOL + button to increase the volume for the SD Card/USB or FM Radio.

VOL -: 

Press the VOL - button to decrease the volume for the SD Card/USB or FM Radio.

Priority Paging Function:

MIC1 features the highest priority in.

Operation instructions

SD/MEDIA

POWER

EQ

MODE

VOL+

NEXT

PP/SCAN

VOL-

PREV

97.60

Machine operation

1. After connecting all audio sources and powering on the mixer amplifier, adjust the level of each audio input to 

achieve the desired “mix”. Care should be taken to when adjusting microphone input volumes and the master 

volume, adjust both of these in small increment’s to avoid feedback (howl around). The goal is to achieve a clear 

balance between music and voice ensuring announcements can be clearly heard.

2. The Clever Acoustics amplifiers all feature output VU meter’s with PEAK indication. Should the PEAK indicator 

illuminate (flashing) the output of the amplifier is too high, turn the master volume anti-clockwise to reduce  

the output.

3. The Clever Acoustics amplifiers all feature protection with LED indication. Should the PROTECT indicator il-

luminate, turn the master volume control anti-clockwise fully and switch off the amplifier for 15 seconds as the 

amplifier may have entered PROTECT mode temporarily due to a peak signal, care should then be taken to ensure 

all input levels are set correctly. If the amplifier persists to enter PROTECT mode the amplifier should be switched 

off and left to cool for 5-10 minutes before switching back on. If the PROTECT indicator remains lit this indicates a 

problem with the amplifier or amplifier load (ie Short Circuit).

4. Speaker & Amplifier systems can produce high sound pressure levels, please operate all controls with caution to 

ensure people are not exposed to excessive or dangerous sound pressure levels. 

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

8

Panel connections

ZONE 1

ZONE 3

ZONE 2

ZONE 4

LINE  OUT

LINE  OUT

LINE  OUT

LINE  OUT

B AL. / UNB AL.

B AL. / UNB AL.

B AL. / UNB AL.

B AL. / UNB AL.

G

G

G

G

100V

100V

100V

100V

OUT P UT

OUT P UT

OUT P UT

OUT P UT

70V

70V

70V

70V

4

4

4

4

C OM

C OM

C OM

C OM

~240V  50Hz  450W  

T 6.3AL  250V

L

L

R

R

LINE

P HANTOM

P HANTOM

P HANTOM

LINE

LINE

LINE

MIC

MIC

MIC

ZO NE

TE L.

V OLUME

G AIN

G AIN

G AIN

G AIN

G AIN

C H 1

C H 2

C H 3

C H 4

C H 5

R E MOT E  MIC  INP UT

R S 232

1W

8

T

MONITOR

P R IOR IT Y

F M ANT

G

R

T E L.PAG ING

LIF T G ND

MUSIC SOURCE

MUSIC SOURCE

P M 600

SL 4120

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

9

Block diagram

Z

O

N

E

 I

D

4

R

E

M

O

T

E

 M

IC

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

10

Connections

Speaker connections

Notes:

• Both the 4 - 16Ω and 100V terminals cannot be used at the same time.

• Impedances indicated in the figures represent the total speaker system (load) impedances. 

• Loads presented to the amplifier must be equal to or greater than listed above. Speaker 

    impedances must be measured using a true impedance meter, do not standard multimeters.

Balanced XLR jack connection

Jack plug

Total impedance

81Ω (MA 4060MP)

41Ω (MA 4120MP)

Total impedance

167Ω (MA 4060MP)

83Ω (MA 4120MP)

WARNING!

Be sure to attach the supplied terminal cover attached after connection. 

Because high voltage is applied to the speaker terminals, care should be 

taken never touch these terminals to avoid electric shock.

All speaker connections should be made using bare wire or suitable insulated 

crimp terminals. Please ensure no loose strands are present as these may 

short across terminals causing damage to the amplifier.

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

11

Problem chart

Cleaning and Maintenance

   

 

 

 

We recommend a frequent cleaning of the product. Please use a soft lint free and moistened cloth.  

Never use alcohol or solvents.

There are no serviceable parts inside the product except for the fuse. Maintenance and service operations  

are only to be carried out by authorised dealers.

Connection With The Mains

Connect the unit to the mains via the IEC mains

inlet using the 13A UK - IEC cord supplied.

The earth has to be connected.

Switch the unit on. After switching on the speaker system, wait 8 - 10 seconds before you turn the volume control 

up in order to avoid speaker damage.

CAUTION!

 Increase the level of each channel up to the point where the clip LEDs illuminate.

Always check the sound pressure level with a meter in order to keep to the legal threshold.

Replacing the fuse

 

Only replace the fuse by a fuse of the same type and rating.

Before replacing the fuse, unplug the mains lead.

Should you need any spare parts, please use genuine parts.

Should you have any further questions, please contact your dealer.

Warnings

CAUTION - DANGER TO LIFE

DISCONNECT FROM THE MAINS BEFORE

STARTING MAINTENANCE OPERATION

Problem

Cause

Solution

No power

The power cord is not connected. Check the power cord and any  

extension cabled.

No sound

The power cord of the respective 
product is not connected prop-
erly or not at all.

The connection socket or the 
plug is dirty.

Check the power cord and if the 
plugs are properly connected 
with the sockets.

Clean the socket and/or the 
plug.

Noise

The input signal is too strong.

Reduce the input signal via the 
gain control.

Distorted sound

Load impedance is to low.

Check load impedance vs am-
plifier specification, reduce as 
required.

 


background image

www.cleveracoustics.co.uk

4 Zone Mixer Amplifier series

  

User Manual

12

WEEE notice

Correct Disposal of this Product 
(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries  
with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed  
with other household wastes at the end of its working life. To prevent possible harm to the  
environment or human health from uncontrolled waste disposal, please separate this from other 
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their 
local government office, for details of where and how they can take this item for environmentally 
safe recycling.

Business users should contact their supplier and check the terms and conditions of the  
purchase contract. This product should not be mixed with other commercial wastes for disposal.