Full Text Searchable PDF User Manual

Order codes:
CRAM17 - MA 4060MP
CRAM18 - MA 4120MP
4 Zone Mixer Amplifier series
with MP3 & FM Tuner
User Manual

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modifications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modification to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to flammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available voltage is between
240V, 50Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualified
engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic
temperature fluctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualified technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• WARRANTY: One year from date of purchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
3
Product overview & technical specifications
The MA 4060MP and MA 4120MP are fully featured, professional mixer amplifier with full onboard zoning
facilities. This mixer amplifier features onboard MP3 (SD/USB) player and FM tuner complete with four zone output
selection. Each input can be easily routed to any of the four zone outputs using the front panel selector, moreover
each input features bass, treble and volume control for precise sound control. Three combo mic/line inputs with
selector and phantom power, via XLR/6.35mm jack. Two phono line inputs, built-in MP3 player on front panel, one
telephone input and one RJ45 port for a remote paging microphone PM 600. Up to six PM 600 microphones can
be cascaded from each amplifier with simple easy connection via standard CAT5 cable.
• All source inputs can be matrix assigned to the 4 zone
outputs simultaneously
• The 5 inputs channels plus onboard MP3 player and FM
tuner
• Three microphone/line inputs with bass, treble, volume and
gain control
• Two AUX phono inputs with bass, treble, volume and gain
control
• MP3 player with SD and USB inputs
• 4 zone remote paging microphone input via RJ45 (requires
CRMIC06 paging microphone)
• Versatile loudspeaker outputs for each four channels:
70V, 100V and 4-16Ω
• Line level, balanced outputs for each zone output
• RS232 serial control port for third party system
communication
• Priority input to override other inputs
• Input priority level from high to low: remote mic, priority
input and telephone input and MIC 1
• Output for monitor loudspeaker, 1W, 8Ω
• Extensive protection including thermal, short-circuit, clip
and overload with indicators
• Ground lift switch
• Fan cooled
4 Zone Mixer Amplifier series
Specifications
MA 4060MP
MA 4120MP
Power output
4 x 60Wrms
4 x 120Wrms
Speaker output
70V, 100V, 4Ω
70V, 100V, 4Ω
Monitor output
1W/8
Ω
1w/8
Ω
Input sensitivity & impedance
CH1/2/3: ±2.5mV/600
Ω
, 175mV/10k
Ω
, balanced input
CH5/6: 350mV/10k
Ω
, balanced input
TEL: 350mV/10K
Ω
Remote MIC: ±837mV/10k
Ω
CH1/2/3: ±2.5mV/600
Ω
, 175mV/10k
Ω
, balanced input
CH5/6: 350mV/10k
Ω
, balanced input
TEL: 350mV/10K
Ω
Remote MIC: ±837mV/10k
Ω
Tone
Bass: ±10dB at 100Hz, Treble: ±10dB at 100Hz
Bass: ±10dB at 100Hz, Treble: ±10dB at 100Hz
SNR
≥65dB
≥65dB
Line 1-4 output level
1V/600
Ω
(balanced output)
1V/600
Ω
(balanced output)
Frequency response
80Hz-16kHz
80Hz-16kHz
MP3
Supports MP3 format, max. capacity: 32GB
Supports MP3 format, max. capacity: 32GB
Recording format
WAV
WAV
SD file system
FAT16 or FAT32 root folder is read only, the player does not
support multiple folders
FAT16 or FAT32 root folder is read only, the player does not
support multiple folders
Harmonic distortion
≤1%
≤1%
Power consumption
375W
750W
Power supply
240V AC 50Hz
240V AC 50Hz
Dimensions
132 x 484 x 440mm
132 x 484 x 440mm
Weight
9.4kg
13.5kg
Order code
CRAM17
CRAM18

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
4
Panel & connection identification
01 - Mute button and indicator
02 - Input routing
03 - Monitor output level indicator
04 - Monitor volume control
05 - Zone amplifier level indicator
06 - Zone monitor selector button
07 - Zone amplifier output volume
control
08 - On/off power switch
09 - MP3/FM Tuner, with USB & SD
card slot
10 - CH1 volume control
11 - CH1 low-pitched tone control
12 - CH1 high-pitched tone control
13 - Power indicator
14 - IEC in socket
15 - Telephone DIP switch and volume
control
16 - CH5 line signal input and signal
gain control
17 - CH4 line signal input and signal
gain control
18 - CH3 microphone signal input and
signal gain control
19 - CH2 microphone signal and signal
gain control
20 - CH1 microphone signal and signal
gain control
21 - Remote microphone input port
22 - RS232 port
23 - LINE, PHANTOM, MIC signal input
selector switch
24 - Vents
25 - Ground lift switch
26 - Monitor output port
27 - Short circuit priority
28 - Telephone signal input port
29 - Radio antenna port
30 - Zone 1 balanced line level signal
output
31 - Zone 1 output terminals (COM, 4
Ω
,
70V and 100V
In the box:
1 x unit,
1 x power cable,
FM antenna &
1 x user manual
1
3
5
4
7
8
6
9
1
11
10
12
13
2
2
ZONE1
ZONE3
ZONE2
ZONE4
LINE
OUT
LINE
OUT
LINE
OUT
LINE
OUT
BAL
. /
UNBAL
.
BAL
. /
UNBAL
.
BAL
. /
UNBAL
.
BAL
. /
UNBAL
.
G
G
G
G
100V
100V
100V
100V
OUTPUT
OUTPUT
OUTPUT
OUTPUT
70V
70V
70V
70V
4
4
4
4
COM
COM
COM
COM
~240V 50Hz 800W
T8AL 250V
L
L
R
R
LINE
PHANTOM
PHANTOM
PHANTOM
LINE
LINE
LINE
MIC
MIC
MIC
ZONE
TEL.
VOLUME
GAIN
GAIN
GAIN
GAIN
GAIN
CH 1
CH 2
CH 3
CH 4
CH 5
REMOTE MIC INPUT
RS232
1W
8
T
MONITOR
PRIORITY
FM ANT
G
R
TEL.PAGING
LIFT GND
14
24
21 22 23
25
15
16
17
18
19
20
26 27
29
28
30
31
Mute priority: MIC 1 highest priority ≥ telephone ≥ remote MIC. The telephone and
MIC 1 priority can be reset via the rear panel short circuit terminals. Usually MIC 1
has the highest priority.

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
5
Rack installation
Rack Installation
The MA Series are rack mountable. The rack you use should be a Double Door Rack where you can open the front
and rear panel. When mounting the amplifier into the rack, please make sure that there is enough space around
the amplifier.
Be careful when mounting the amplifier into the rack. Put the heaviest products into the lower part of the rack.
The front panel is not designed to absorb acceleration forces occuring during transportation.
Inputs
Short cables runs improve the sound quality remarkably. Input cables should be short and direct, since high
frequencies will mostly be absorbed if the cables are unnecessarily long. Besides that a longer cable may lead to
humming and noise problems. If the cable runs are unavoidable, you should use balanced cables.
Outputs
The high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long and thin cables
used for low impedance (4-16Ω) speakers will influence the damping factor and thus the low frequencies in a
negative way. In order to safeguard good sound quality, the damping factor should lie around 50. The longer a
cable has to be the thicker it should be. For longer cable runs please ensure the 100V outputs are used for 100V
speakers.
Connect your speaker systems via the speaker terminals (COM = -VE)
Examples:
1) COM + 4-16Ω
2) COM + 70V
3) COM + 100V
Note: Please do not use more than one pair of output terminals on any one output zone.
Connections To The Mains
Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the available supply
is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be connected at all times. DO
NOT remove or disconnect the earth..

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
6
Operation instructions
Initial Start Up Procedure
•
Reset all “Level” or “Volume” controls to the “0” position on the front panel. Reset the BASS and TREBLE
controls to the centre point.
•
Reset CH1 thru CH5 gain controls & TEL level control on the rear panel to the “0” position.
•
Connect the audio sources & mains power input.
•
Switch on the amplifier using the mains switch on the front panel. The LED indicator (13) will illuminate
BLUE if the amplifier is ready for use and working correctly, if the indicator illuminates RED this indicates
the amplifier is under PROTECT status.
•
Adjust CH1 thru CH5 gain controls to match the input signal levels between different sources
CH1 to CH5 Operation (note: CH1 thru CH5 feature the same operation)
1)
BASS control:
BASS control offers tonal adjustment for the low frequency, turn
clockwise to increase and anti-clockwise to decrease.
2)
TREBLE control:
TREBLE control offers tonal adjustment for the high frequency, turn
clockwise to increase and anti-clockwise to decrease.
3)
VOLUME (LEVEL) control:
VOLUME (LEVEL) control offers adjustment for the
corresponding input channel, turn clockwise to increase and anti-clockwise
to decrease to reduce the volume.
4)
MUTE button:
Each channel input (CH1 thru CH5) may be muted by pressing the
MUTE button. The button features LED illumination when muted.
5)
Z1 to Z4 Zone Selector buttons:
Each of the CH1 to CH5 input channels can be
routed to any combination of the four output zones. The zone selector buttons
feature LED illumination, the LED will illuminate if the zone is selected.
6)
VOLUME (LEVEL) control:
VOLUME (LEVEL) control offers adjustment for the
corresponding output channel, turn clockwise to increase and anti-clockwise to
decrease to reduce the volume.
7)
MON button:
The MA 4060MP and MA 4120MP amplifiers both feature a Monitor
output function for status confirmation purposes. Select the MON button on the
desired channel to activate the Monitor function. The Monitor output features a
Volume (Level) control.
8)
Output VU Meter:
Each of the five outputs (Z1 to Z4 and MON) feature LED VU
meter plus CLIP and PROTECTION status indicators. The CLIP LED will illuminate to
indicate when the audio signal is too high, in this instance reduce the VOLUME by
turning the volume control anti-clockwise. The PROTECT LED will illuminate if the
amplifier detects a fault or a problem with the output circuit.
Z2
Z4
TREBL E
+10
MON
7
8
9
7
8
9
MUTE
Z1
Z3
LEVEL
CH 2
BASS
-10
-10
+10
ZONE 1
LEVEL
0dB
PROT
CLIP
-5
-10
-15
0
1
2
3
4
5
6
10
0
1
2
3
4
5
6
10

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
7
MP3 Player / FM Radio Operation:
POWER:
The onboard MP3 Player & FM radio may be powered up or down independent of the main amplifier.
Press the power switch to power on or power off the MP3/FM Radio.
MODE:
Press the mode button to select FM Radio, SD Card or USB.
PP/SCAN:
The FM radio tuner features automatic tuning, press the PP/SCAN button to activate the scan function.
NEXT:
Press the NEXT button to skip music tracks next when using the SD Card or USB.
PREV:
Press the PREV button to skip music tracks previous when using the SD Card or USB.
EQ:
Press the EQ button to adjust the equaliser settings for the SD Card/USB or FM Radio.
VOL +:
Press the VOL + button to increase the volume for the SD Card/USB or FM Radio.
VOL -:
Press the VOL - button to decrease the volume for the SD Card/USB or FM Radio.
Priority Paging Function:
MIC1 features the highest priority in.
Operation instructions
SD/MEDIA
POWER
EQ
MODE
VOL+
NEXT
PP/SCAN
VOL-
PREV
97.60
Machine operation
1. After connecting all audio sources and powering on the mixer amplifier, adjust the level of each audio input to
achieve the desired “mix”. Care should be taken to when adjusting microphone input volumes and the master
volume, adjust both of these in small increment’s to avoid feedback (howl around). The goal is to achieve a clear
balance between music and voice ensuring announcements can be clearly heard.
2. The Clever Acoustics amplifiers all feature output VU meter’s with PEAK indication. Should the PEAK indicator
illuminate (flashing) the output of the amplifier is too high, turn the master volume anti-clockwise to reduce
the output.
3. The Clever Acoustics amplifiers all feature protection with LED indication. Should the PROTECT indicator il-
luminate, turn the master volume control anti-clockwise fully and switch off the amplifier for 15 seconds as the
amplifier may have entered PROTECT mode temporarily due to a peak signal, care should then be taken to ensure
all input levels are set correctly. If the amplifier persists to enter PROTECT mode the amplifier should be switched
off and left to cool for 5-10 minutes before switching back on. If the PROTECT indicator remains lit this indicates a
problem with the amplifier or amplifier load (ie Short Circuit).
4. Speaker & Amplifier systems can produce high sound pressure levels, please operate all controls with caution to
ensure people are not exposed to excessive or dangerous sound pressure levels.

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
8
Panel connections
ZONE 1
ZONE 3
ZONE 2
ZONE 4
LINE OUT
LINE OUT
LINE OUT
LINE OUT
B AL. / UNB AL.
B AL. / UNB AL.
B AL. / UNB AL.
B AL. / UNB AL.
G
G
G
G
100V
100V
100V
100V
OUT P UT
OUT P UT
OUT P UT
OUT P UT
70V
70V
70V
70V
4
4
4
4
C OM
C OM
C OM
C OM
~240V 50Hz 450W
T 6.3AL 250V
L
L
R
R
LINE
P HANTOM
P HANTOM
P HANTOM
LINE
LINE
LINE
MIC
MIC
MIC
ZO NE
TE L.
V OLUME
G AIN
G AIN
G AIN
G AIN
G AIN
C H 1
C H 2
C H 3
C H 4
C H 5
R E MOT E MIC INP UT
R S 232
1W
8
T
MONITOR
P R IOR IT Y
F M ANT
G
R
T E L.PAG ING
LIF T G ND
MUSIC SOURCE
MUSIC SOURCE
P M 600
SL 4120

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
9
Block diagram
Z
O
N
E
I
D
1
2
3
4
R
E
M
O
T
E
M
IC

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
10
Connections
Speaker connections
Notes:
• Both the 4 - 16Ω and 100V terminals cannot be used at the same time.
• Impedances indicated in the figures represent the total speaker system (load) impedances.
• Loads presented to the amplifier must be equal to or greater than listed above. Speaker
impedances must be measured using a true impedance meter, do not standard multimeters.
Balanced XLR jack connection
Jack plug
Total impedance
81Ω (MA 4060MP)
41Ω (MA 4120MP)
Total impedance
167Ω (MA 4060MP)
83Ω (MA 4120MP)
WARNING!
Be sure to attach the supplied terminal cover attached after connection.
Because high voltage is applied to the speaker terminals, care should be
taken never touch these terminals to avoid electric shock.
All speaker connections should be made using bare wire or suitable insulated
crimp terminals. Please ensure no loose strands are present as these may
short across terminals causing damage to the amplifier.

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
11
Problem chart
Cleaning and Maintenance
We recommend a frequent cleaning of the product. Please use a soft lint free and moistened cloth.
Never use alcohol or solvents.
There are no serviceable parts inside the product except for the fuse. Maintenance and service operations
are only to be carried out by authorised dealers.
Connection With The Mains
Connect the unit to the mains via the IEC mains
inlet using the 13A UK - IEC cord supplied.
The earth has to be connected.
Switch the unit on. After switching on the speaker system, wait 8 - 10 seconds before you turn the volume control
up in order to avoid speaker damage.
CAUTION!
Increase the level of each channel up to the point where the clip LEDs illuminate.
Always check the sound pressure level with a meter in order to keep to the legal threshold.
Replacing the fuse
Only replace the fuse by a fuse of the same type and rating.
Before replacing the fuse, unplug the mains lead.
Should you need any spare parts, please use genuine parts.
Should you have any further questions, please contact your dealer.
Warnings
CAUTION - DANGER TO LIFE
DISCONNECT FROM THE MAINS BEFORE
STARTING MAINTENANCE OPERATION
Problem
Cause
Solution
No power
The power cord is not connected. Check the power cord and any
extension cabled.
No sound
The power cord of the respective
product is not connected prop-
erly or not at all.
The connection socket or the
plug is dirty.
Check the power cord and if the
plugs are properly connected
with the sockets.
Clean the socket and/or the
plug.
Noise
The input signal is too strong.
Reduce the input signal via the
gain control.
Distorted sound
Load impedance is to low.
Check load impedance vs am-
plifier specification, reduce as
required.

www.cleveracoustics.co.uk
4 Zone Mixer Amplifier series
User Manual
12
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government office, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the
purchase contract. This product should not be mixed with other commercial wastes for disposal.